Позиционирование продукта: DPP Series Single-phase AC-DC DIN Rail Mount Industrial Switching Источник питания (НРНД, Not Recommended for New Design)
NRND = Not Recommended for New Design. The manufacturer recommended replacement model is DRB240-24-1. (Примечание: Назначение выводов, mounting and function compatibility are not fully guaranteed; engineering verification is required.)
✅ Определение модели
DPP: DIN rail mounting power supply series
240: Rated power 240W
24: Output voltage DC24V
1: Single-phase AC input (суффикс 3 = 3-phase input, DPP240-24-3)
📌 Core Electrical Specifications
| Элемент | Параметр |
| Вход | Single-phase 90~264VAC; DC 210~370Vdc; 47~63Hz, automatic wide-range selection |
| Выход | 24 В постоянного тока, номинальный ток 10А, power 240W; регулируемый диапазон: 22.5~28.5Vdc |
| Эффективность | Типичный 89% |
| Output accuracy | ±1% |
| Ripple & Шум | <100мВ (20MHz bandwidth) |
| Защита | Защита от перегрузки по току (120~145% of rated), защита от перенапряжения, защита от короткого замыкания |
| Parallel Operation | Поддерживает до 3 единицы параллельно, built-in droop current sharing mode; switch to parallel mode; minimum load ≥10% for parallel operation |
| DC Good Relay | Built-in power-good dry contact signal for ПЛК мониторинг |
| Рабочая температура | -40℃ ~ +71℃ (derating required at full load, refer to datasheet) |
📏 Mechanical Dimensions & Установка
DIN-рейка (TS35) snap-on mounting, enclosed metal housing, natural convection cooling (безвентиляторный)
Ширина: 83 мм
Высота: 125 мм
Глубина: 126 мм
🧾 Terminal Definition (Screw Terminals)
- DC Good relay
- DC Good relay
- В+
- В+
- V.-
- V.-
- PE Protective Earth
- L Line
- N Neutral
🛠️ Typical Application Scenarios
Шкафы управления промышленной автоматизацией, ПЛК, датчики, электромагнитные клапаны, автоматизация зданий, тест & measurement equipment, factory 24V DC bus power supply.
⚠️ Key Notes
- Статус: НРНД. Available as spare parts for legacy projects; DRB240-24-1 is recommended for new projects. Установочные размеры, расположение терминала, DC-Good signal and parallel function differences must be verified.
- Параллельная работа: Set identical output voltage for all units and toggle switch to parallel mode; single-unit mode provides better load regulation accuracy.
- Тепловыделение: Keep ventilation clearance on all sides; derating required for high ambient temperature.
- Сертификаты: UL/EN/IEC62368-1, industrial safety certification.
🔧 Troubleshooting
Нет вывода: Measure L/N input voltage; check upstream circuit breaker and fuse; verify PE grounding; check green LED indicator on power supply.
Voltage drop under load: Перегрузка, incorrect parallel switch setting, незакрепленные клеммы; verify output current ≤10A.
DC Good inactive: Power supply enters latch-off protection; troubleshoot short circuit / overvoltage on downstream circuit.
Excessive ripple: Check grounding, add electrolytic / ceramic capacitor on output side, inspect cable shielding.
📎 Domestic Alternatives (DIN rail 240W 24V/10A, same specification)
Phoenix Contact QUINT-PS/1AC/24DC/240, Mean Well SDR-240-24, Delta DRP-240-24
ТДК-Лямбда DPP240-24-1 Complete Installation Guide
Suitable for TS35/7.5 or TS35/15 standard DIN rail. Never mount upside down (output terminals must not face down). Естественное конвекционное охлаждение, ventilation clearance required on all sides.
- Предустановочная подготовка
1.1 Инструменты & Материалы
крестовая отвертка (for terminal screws)
Динамометрический ключ (рекомендуется)
Кабели: AWG24~AWG10 (screw terminal version)
Standard TS35 DIN rail inside control cabinet
Upstream circuit breaker/fuse, PE protective earth wire
1.2 Safety Preconditions
Perform work in power-off state; confirm upstream power is fully disconnected
Class I equipment. PE protective earth must be reliably connected, otherwise electric shock hazard exists
Inspect power supply for damage and terminal oxidation before installation
- DIN Rail Mechanical Installation Steps
- Hook the top clip of the power supply onto DIN rail;
- Press the power supply body inward until the bottom clip clicks and locks;
- Shake slightly to confirm secure fixation on rail;
- Удаление: Use flat screwdriver to pry down the bottom spring clip and pull the unit outward.
Heat dissipation requirement: Minimum 25mm ventilation gap on top, нижний, left and right. Do not mount close to heat-generating components such as contactors and PLCs. Enclosure covering and upside-down mounting are prohibited. (Correct orientation: output terminals upward)
- Клеммная проводка (Screw Terminal Version)
Terminal numbering (from left to right):
1,2: DC Good relay dry contact (power status passive contact, connect to PLC/alarm circuit)
3,4: V+ DC24V output positive
5,6: VDC24V output negative
7: PE Protective Earth
8: L Line
9: N Neutral
Torque Specification (per manufacturer manual)
Входные клеммы (Л/Н/ПЭ): Max torque 1.0 Н·м
Output terminals (V+ V-, DC Good): Max torque 0.65 Н·м
Do not over-tighten to avoid screw slipping or terminal base cracking. All conductor strands must be fully inserted into terminals; no exposed copper strands to prevent short circuit.
Последовательность подключения
- Connect PE (Терминал 7) for reliable earthing first;
- Then connect output side: В+, В-, DC Good signal;
- Finally connect input side L and N;
- После подключения, check for short circuit and poor contact.
- DIP Switch Setting (Одинокий / Parallel Mode)
Single/Parallel DIP switch on front panel:
Одинокий (Single Unit): Factory default setting, high load regulation accuracy. Must use this setting for standalone operation.
Parallel: До 3 DPP240 units for power expansion. Parallel requirements:
- All units set DIP switch to Parallel;
- Output cables of all units must have identical wire gauge and length;
- System minimum load ≥10% rated current, maximum load ≤90%;
- Pre-adjust all power supplies to the same output voltage.
Voltage adjustment: Front panel potentiometer, adjustable range DC22.5~28.5V
- Процедура ввода в эксплуатацию при включении питания
- В выключенном состоянии, use multimeter to confirm no short circuit on input and output loops;
- Verify DIP switch position;
- Close upstream breaker and power on;
- Observe green LED of power supply; measure output voltage to confirm set value;
- Check DC Good relay: contacts close when power supply healthy; contacts open during fault / защита;
- Perform loaded test, check temperature rise, confirm no abnormal overheating.
- Prohibited Installation Practices (Важный)
- ❌ Upside-down mounting (output terminals down), which damages convection cooling and triggers over-temperature protection or permanent damage;
- ❌ No 25mm ventilation clearance around unit;
- ❌ PE earth connection omitted;
- ❌ Parallel operation with cables of unequal length or load less than 10%;
- ❌ Improper terminal torque; loose or exposed copper strands;
- ❌ Use in high humidity, corrosive and dusty environment without protective enclosure.
- Common Installation Issues
- No green LED after power-on: Check L/N input voltage, upstream breaker, internal fuse (internal fuse cannot be replaced by user; unit must be returned for repair if damaged)
- Voltage drop under load: Свободные клеммы, insufficient wire gauge, incorrect parallel switch setting, load exceeds 10A;
- Power supply overheating: Insufficient ventilation gap, nearby heat sources, высокая температура окружающей среды, требуется снижение номинальных характеристик.
TDK-Lambda DPP240-24-1 Outline Dimensions
Nominal dimensions (DIN rail clip protrusion excluded)
Ширина(Вт): 83 мм (3.27 дюйм)
Высота(ЧАС): 125 мм (4.92 дюйм)
Глубина(Д): 126 мм (4.96 дюйм)
Масса: приблизительно. 1000г (1кг)
Mounting rail: Standard TS35 (7.5 / 15мм) DIN-рейка
Cabinet Layout Notes
- 83mm width occupies large horizontal space in control cabinet. Compare with alternative DRB240-24-1 (ширина ок.. 41мм). DPP series is wider;
- Heat dissipation clearance: minimum 25mm on all sides;
- Depth 126mm. When designing cabinet depth from backplate to door, extra space for front terminal wiring must be reserved.
Reference Comparison (Alternative Model DRB240-24-1)
DRB240-24-1: 41 × 120 × 125 мм, nearly half the width. Large difference in installation space, cannot be directly drop-in replacement.
TDK-Lambda DPP240-24-1 Power Factor
Typical Power Factor PF = 0.7 (230VAC input, full load)
This power supply does not integrate active PFC circuit, adopting conventional rectifier topology, resulting in relatively low power factor.
Дополнительное описание
- Условия испытания: 230 В переменного тока, full rated output; PF value decreases under 115VAC low input voltage.
- Примечание: 0.7 is typical value not minimum; power factor further drops under light load.
- System Impact:
If project requires strict harmonic and power factor compliance (например. EN61000-3-2), add external PFC filter at input front end.
Alternative model DRB240-24-1 of same power level has better PF performance.
- Reference input current (full load):
230ВАК: приблизительно. 1.5А
115ВАК: приблизительно. 4.0А
Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер