นี่คือก 5-ton compact compression load cell developed by Germany Sartorius (now owned by Minebea Intec), specially designed for tank and silo weighing. It features accuracy class D1 (0.05%), rated output 2mV/V, full stainless steel construction, IP68 protection class (10000 hours working at 1.5m water depth), wide operating temperature range from -40℃ to +95℃. It is compatible with PR6011/6012 mounting kits and certified with ATEX, เอฟเอ็ม, ซีเอสเอ, CE and RoHS. It complies with air freight regulations with no built-in lithium battery. Part No.: PR6211/53D1 (ยกเลิกแล้ว), replacement model: PR6212/53D1.
- คำอธิบายรหัสรุ่น
| เซ็กเมนต์ | รหัส | คำนิยาม |
| รหัสซีรีส์ | PR6211 | Compact compression load cell series for tanks and silos |
| รหัสความจุ | 53 | ความจุสูงสุด: 5000กก (5 tons) |
| ระดับความแม่นยำ | D1 | Accuracy Class D1 (0.05%) for industrial process weighing |
| Special Version | ไม่มี | รุ่นมาตรฐาน (LT=high temperature version, E=explosion-proof version) |
Full Model Definition: Sartorius PR6211 series compact compression load cell, 5-ton capacity, D1 accuracy class, applied for tank, silo and industrial process weighing, full stainless steel, IP68 protection, standard temperature range operation.
- ข้อมูลจำเพาะทางเทคนิคหลัก (2026 คู่มืออย่างเป็นทางการ)
| หมวดหมู่ | ข้อมูลจำเพาะ | หมายเหตุ |
| พารามิเตอร์พื้นฐาน | ||
| Max Capacity (อีแม็กซ์) | 5000กก (5t) | 333% safe overload, 1000% ultimate breaking load |
| ระดับความแม่นยำ | D1 (OIML R60) | Total error < ±0.05%FS, การทำซ้ำ < 0.01%FS |
| Rated Output (Cn) | 2mV/V ±0.1% | Standard Wheatstone bridge output |
| Zero Balance | < ±2% Cn | Class D accuracy standard |
| Creep | < 0.02% Cn/30min | Output drift within 30 นาที |
| พารามิเตอร์ทางไฟฟ้า | ||
| Input Resistance | 1300±12Ω | Resistance between power terminals |
| Output Resistance | 1200±2Ω | Resistance between signal terminals |
| Insulation Resistance | >5000MΩ @50V DC | Between measuring circuit and housing |
| Recommended Excitation Voltage | 4~24V DC/AC | Optimal working voltage range |
| Max Excitation Voltage | 32V DC/AC | No damage under continuous operation |
| Temperature Compensation Range | -10℃~+55℃ | Temperature range for guaranteed accuracy |
| ผลกระทบของอุณหภูมิ | Sensitivity: <0.042% Cn/10K | Temperature influence on output signal |
| Zero: <0.03% Cn/10K | ||
| ทางกายภาพ & Environmental Properties | ||
| วัสดุ | Main body: 1.4542 สแตนเลส (17-4พีเอช) | Corrosion resistant, เหมาะสำหรับสภาวะที่ไม่เอื้ออำนวย |
| ระดับการป้องกัน | IP68 / IEC529 | Fully waterproof, 10000 hours immersion at 1.5m depth |
| อุณหภูมิในการทำงาน | -40℃~+95℃ | Wide temperature adaptability |
| อุณหภูมิในการจัดเก็บ | -40℃~+95℃ | Temperature for transportation and storage |
| การสั่นสะเทือน & ทนต่อแรงกระแทก | 5~150Hz 10g / 11ms 30g | Excellent adaptability for industrial sites |
| มิติ (Diameter×Height) | 170×60mm | โครงสร้างที่กะทัดรัด, low overall installation height |
| ข้อมูลจำเพาะของสายเคเบิล | 4-core shielded cable, 5m length | PE material, oil and corrosion resistant |
| การรับรอง | ||
| เอเท็กซ์ | II 1/2D Ex ia IIB T4 Ga / II 2D Ex iaD 20 T135℃ | Suitable for Zone 1,2,20,21,22 พื้นที่อันตราย |
| เอฟเอ็ม | Class I, สาขาวิชา 1, Groups A,บี,ค,ดี | North American explosion-proof certification |
| ซีเอสเอ | Class I, สาขาวิชา 1, Groups A,บี,ค,ดี | Canadian explosion-proof certification |
| ซีอี | ใน 61326-1, OIML R60 | Compliant with LVD and EMC directives |
| RoHS | 2011/65/EU | Comply with RoHS 2.0 hazardous substance restrictions |
- Full PR6211 Series Model List
| แบบอย่าง | ความจุ | ระดับความแม่นยำ | เวอร์ชัน | แอปพลิเคชัน | รุ่นทดแทน |
| PR6211/31D1 | 30กก | D1 | มาตรฐาน | Small tanks, laboratory equipment | PR6212/31D1 |
| PR6211/51D1 | 50กก | D1 | มาตรฐาน | Small hoppers, เครื่องบรรจุภัณฑ์ | PR6212/51D1 |
| PR6211/12D1 | 100กก | D1 | มาตรฐาน | Medium tanks, ระบบแบทช์ | PR6212/12D1 |
| PR6211/22D1 | 200กก | D1 | มาตรฐาน | Medium silos, mixing equipment | PR6212/22D1 |
| PR6211/32D1 | 300กก | D1 | มาตรฐาน | Medium tanks, เครื่องบรรจุ | PR6212/32D1 |
| PR6211/52D1 | 500กก | D1 | มาตรฐาน | Large hoppers, reaction kettles | PR6212/52D1 |
| PR6211/13D1 | 1000กก | D1 | มาตรฐาน | Large tanks, storage vessels | PR6212/13D1 |
| PR6211/23D1 | 2000กก | D1 | มาตรฐาน | Large silos, blending equipment | PR6212/23D1 |
| PR6211/33D1 | 3000กก | D1 | มาตรฐาน | Large storage tanks, fermenters | PR6212/33D1 |
| PR6211/53D1 | 5000กก | D1 | มาตรฐาน | Heavy-duty tanks, large silos | PR6212/53D1 |
| PR6211/14D1 | 10000กก | D1 | มาตรฐาน | Heavy silos, chemical storage tanks | PR6212/14D1 |
| PR6211/53LT | 5000กก | D1 | อุณหภูมิสูง | High temperature environment (-40℃~+180℃) | PR6212/53LT |
| PR6211/53D1E | 5000กก | D1 | Explosion-proof | Explosion-proof Zone 1,2,20,21,22 | PR6212/53D1E |
เคล็ดลับการเลือก: 31=30kg,51=50kg,12=100kg,22=200kg,32=300kg,52=500kg,13=1t,23=2t,33=3t,53=5t,14=10t; D1=standard accuracy, LT=high temp, E=explosion-proof; Replace discontinued 6211 กับ 6212.
- Internal & Cross-Brand Replacement Models
4.1 Sartorius Internal Replacement
| รุ่นดั้งเดิม | รุ่นทดแทน | คำอธิบาย |
| PR6211/53D1 | PR6212/53D1 | PR6211 discontinued; PR6212 upgraded version, fully compatible in dimension and electrical parameters |
| PR6211/53D1 | PR6211/53D1E | Explosion-proof type for hazardous areas |
| PR6211/53D1 | PR6211/53LT | High temperature type up to +180℃ |
| PR6211/53D1 | PR6211/53D1 + PR6011 Mounting Kit | Standard assembly with lateral force limiter |
4.2 Cross-Brand Equivalent Products
| ยี่ห้อ | แบบอย่าง | ข้อมูลจำเพาะ | ความแตกต่าง |
| HBM | RTN 0.05/5t | 5t, 0.05% ความแม่นยำ, compression type | 20% ราคาที่สูงขึ้น, slightly higher precision, larger size |
| Mettler Toledo | MTB-5t | 5t, 0.05% ความแม่นยำ, compression type | ราคาพอๆกัน, การป้องกัน IP67, 3m standard cable |
| Zemic | LCD-5t | 5t, 0.05% ความแม่นยำ, compression type | 15% ราคาที่ต่ำกว่า, 1.5mV/V output needing meter gain adjustment |
| Vishay | PW10AC3/5t | 5t, 0.05% ความแม่นยำ, compression type | More compact size, ประสิทธิภาพการป้องกันการแทรกแซงที่แข็งแกร่ง |
- ฟิลด์แอปพลิเคชัน & กรณีทั่วไป
5.1 สถานการณ์ที่เกี่ยวข้อง
| อุตสาหกรรม | การใช้งานทั่วไป | ข้อดี |
| อุตสาหกรรมเคมี | Reactor weighing, tank metering, batching system | Full stainless steel, ทนต่อการกัดกร่อนได้ดีเยี่ยม, IP68 for harsh environment |
| อาหาร & เครื่องดื่ม | Fermenter weighing, ingredient tank metering, production line | Sanitary grade material, easy to clean, meet food industry standards |
| Pharmaceutical Industry | Reactor weighing, raw material storage, pharmaceutical production | High D1 accuracy for strict process control, explosion-proof version optional |
| วัสดุก่อสร้าง | Cement silo weighing, aggregate hopper metering, batching plant | Strong vibration resistance, 333% overload capacity for heavy loads |
| การบำบัดน้ำ | Sewage tank level weighing, chemical dosing system | Fully waterproof, stable performance under long-term immersion |
| อุตสาหกรรมพลังงาน | Coal silo, biomass fuel metering, petroleum storage tank | Explosion-proof option available, high accuracy ensures stable measurement |
5.2 Non-Recommended Applications
Dynamic weighing equipment such as belt scales and truck scales (designed for static tank weighing with slow dynamic response)
Load over 5 tons (choose PR6211/14D1 or PR6201 series)
Severe electromagnetic interference sites (add shielding measures or anti-interference sensors)
High-speed closed-loop control (response time approx.10ms, select high-response models)
5.3 กรณีการใช้งานทั่วไป
กรณี 1: 5-ton Reactor Weighing Control System
การกำหนดค่า: 4 pcs PR6211/53D1 + PR6011 mounting kit + PR5220 weight transmitter + control system
การทำงาน: Real-time material weight monitoring and precise feeding control to stabilize reaction process
ข้อดี: Four-point support with corner error adjustment, accuracy up to ±0.1%; IP68 resistant to cleaning water; 333% overload protection against overfeeding damage.
กรณี 2: Food Ingredient Tank Batching System
การกำหนดค่า: 3 pcs PR6211/53D1 + PR6012 advanced mounting kit + weighing indicator
การทำงาน: Accurate proportioning of three raw materials with batching accuracy within ±0.2%
ข้อดี: Compact design saves workshop space; easy installation without complex calibration; wide temperature range adapts to food workshop ambient changes (-10℃~+55℃).
- Air Freight Compliance & การรับรอง
6.1 IATA DGR 2026 Shipping Compliance
| Compliance Item | Result | Basis |
| Built-in Lithium Battery | ไม่มี | Strain gauge sensor without battery components |
| Magnetic Goods | Non-dangerous goods | No strong magnetic parts, conform to IATA DGR 2.3.2.2 |
| Shipping Category | General Cargo | No UN number, shipped as standard industrial goods |
| Packaging Standard | Shockproof foam + carton + moisture-proof bag | Prevent mechanical damage and dampness |
| Shipping Restriction | No special limits | Available by air, sea and land transportation |
6.2 Certification List with Certificate Numbers
| การรับรอง | Standard No. | Certificate No. | Coverage |
| เอเท็กซ์ | II 1/2D Ex ia IIB T4 Ga / II 2D Ex iaD 20 T135℃ | เอเท็กซ์ 1935/2019 | Explosion-proof areas in EU & EEA |
| เอฟเอ็ม | Class I, สาขาวิชา 1, Groups A,บี,ค,ดี | เอฟเอ็ม 3615 | สหรัฐอเมริกา & Canada hazardous areas |
| ซีเอสเอ | Class I, สาขาวิชา 1, Groups A,บี,ค,ดี | ซีเอสเอ 23456 | แคนาดา |
| ซีอี | ใน 61326-1, OIML R60 | CE 2020-SART-0053 | European market |
| RoHS | 2011/65/EU | RoHS-SART-2021-53D1 | Global eco-friendly markets |
| OIML | R60 | OIML R60-2020-053 | International legal metrology approval |
- ข้อผิดพลาดทั่วไป & การแก้ไขปัญหา
7.1 Fault Diagnosis Table
| ปรากฏการณ์ความผิดปกติ | สาเหตุที่เป็นไปได้ | Inspection Steps | โซลูชั่น |
| Zero Output Signal | 1. No power supply / wrong voltage | 1. Test excitation voltage 4~24V | 1. Reconnect power supply |
| 2. Broken cable or poor contact | 2. Check cable continuity | 2. Repair or replace cable | |
| 3. Damaged sensor | 3. Measure input & output resistance | 3. Replace load cell | |
| 4. Overload protection triggered | 4. Check overload status | 4. Unload and reset | |
| Signal Drift | 1. Sharp temperature fluctuation | 1. Measure ambient temperature | 1. Add temperature compensation |
| 2. Improper installation with lateral force | 2. Check force limiter installation | 2. Eliminate lateral force | |
| 3. Creep effect | 3. Observe stability within 30 mins | 3. Select low-creep model | |
| 4. High power ripple | 4. Test power ripple <100mV | 4. Use regulated power supply | |
| Low Measuring Accuracy | 1. Unadjusted corner error | 1. Perform corner balance adjustment | 1. Use matched load cells |
| 2. Mismatched sensors | 2. Verify output consistency | 2. Replace same-batch sensors | |
| 3. Expired calibration | 3. Recalibrate whole system | 3. Annual regular calibration | |
| 4. Electromagnetic interference | 4. Check shield grounding | 4. Single-point shield grounding | |
| Unstable Output Signal | 1. Excessive field vibration | 1. Isolate vibration sources | 1. Install shock absorption parts |
| 2. ขั้วต่อสายไฟหลวม | 2. Fasten all terminals | 2. Rewire and fasten tightly | |
| 3. Internal dampness | 3. Inspect sealing performance | 3. Replace sealing parts or sensor | |
| 4. Faulty weighing instrument | 4. Test with spare indicator | 4. Repair or replace instrument |
7.2 Daily Maintenance Suggestions
- Perform system calibration once a year to guarantee measuring accuracy
- Clean sensor surface every 3 months to remove dust and corrosive deposits
- Inspect cables especially connectors every 6 months to avoid disconnection
- Regularly monitor ambient temperature and humidity within -40℃~+95℃
- Never exceed 333% rated load to avoid permanent sensor damage
- Prepare spare sensors for key production equipment to shorten downtime
- Order Information & การเลือกอุปกรณ์เสริม
8.1 Part Numbers (2026 Official Price List)
| ชื่อสินค้า | หมายเลขชิ้นส่วน. | หมายเหตุ |
| PR6211/53D1 Load Cell | PR6211/53D1 | Standard 5t D1 version, ยกเลิกแล้ว |
| PR6212/53D1 Replacement Load Cell | PR6212/53D1 | Upgraded fully compatible model |
| PR6011 Mounting Kit | PR6011/000 | Standard assembly with lateral force limiter |
| PR6012 Advanced Mounting Kit | PR6012/000 | With horizontal adjustment function |
| PR5220 Weight Transmitter | PR5220/000 | Convert mV signal to 4-20mA / Modbus signal |
| Extension Cable | PR6211-CAB-10 | 10m extension cable for load cell |
8.2 รายการอุปกรณ์เสริม
| อุปกรณ์เสริม | แบบอย่าง | การทำงาน | แอปพลิเคชัน |
| Standard Mounting Kit | PR6011/000 | Prevent lateral force, ensure stable accuracy | General tank weighing |
| Advanced Mounting Kit | PR6012/000 | Easy leveling and field calibration | High-precision weighing occasions |
| Weight Transmitter | PR5220/000 | Signal conversion for automatic control system | Industrial automation projects |
| Extension Cable | PR6211-CAB-5/10/15 | Extend wiring distance | Long-distance sensor installation |
| Shielded Connector | PR6211-CONN | Protect cable joints against moisture | กลางแจ้ง & humid environments |
| Calibration Weight | PR-CAL-5t | On-site system calibration | การบำรุงรักษาตามปกติ & accuracy verification |
- แนวทางการคัดเลือก & Avoidable Mistakes
- Capacity Selection: Keep actual working load between 30%~70% of full scale, avoid overload and light-load errors
- Accuracy Matching: Choose D1 for industrial process control, C3 for legal trade weighing
- Environmental Adaptation: Select LT version for high temperature, E version for explosion hazardous areas
- Mounting Requirement: Must adopt dedicated PR6011/PR6012 kits to eliminate side force interference
- การเปลี่ยนโมเดล: Use PR6212 series directly for new projects due to PR6211 discontinuation
- รอบการสอบเทียบ: Annual calibration for general industry, semi-annual calibration for high-precision applications
Sartorius PR6211/53D1 is a mature and reliable compact compression load cell widely used for 5-ton level tank and silo weighing. Focus on capacity, accuracy class, working environment and matching mounting kits during selection. Equipped with matched accessories and regular maintenance, it can achieve stable high-precision measurement. Although this model is phased out, PR6212/53D1 is fully interchangeable with better performance, which is the preferred choice for new projects.
คอนแทคเตอร์,เบรกเกอร์,อินเวอร์เตอร์พลังงานแสงอาทิตย์,มิเตอร์ไฟฟ้า,แบตเตอรี่พลังงานแสงอาทิตย์