The ACS880-01 series is ايه بي بي’s flagship wall-mounted industrial single-drive محرك التردد المتغير. Equipped with self-developed DTC Direct Torque Control technology, it supports multiple motor types including asynchronous motors, permanent magnet synchronous motors and synchronous reluctance motors. Integrated with safety, communication and energy efficiency management functions, it serves as the standard drive solution for general industrial and process industries.
- Breakdown of Model Code
`ACS880-01-246A-4`
- ACS880: All-compatible industrial single-drive VFD series with standard DTC Direct Torque Control, power coverage ranging from 0.55 كيلوواط ل 3200 kW across the full lineup.
- -01: Wall-mounted single drive module design, available for direct wall mounting or cabinet installation with a compact single-drive form factor.
- 246أ: Rated continuous output current of the VFD, 246 أ, the core reference parameter for motor matching and overload protection.
- -4: Voltage class identifier, nominally designed for 480 V three-phase power grids, supporting wide input voltage from 380 V to 500 V for various power supply scenarios at home and overseas.
- Core Electrical Technical Specifications
- Power and Current Ratings
| عنصر المعلمة | قيمة | ملاحظات |
| Rated Power for Constant Torque (ط م / واجب ثقيل) | 132 كيلوواط (400 V grid) / 160 كيلوواط (480 V grid) | For continuous heavy-duty loads such as conveyors and mixers |
| Rated Power for Variable Torque (VT / Light Duty) | 160 كيلوواط (400 V grid) / 200 كيلوواط (480 V grid) | For square-torque loads such as fans and water pumps |
| Rated Continuous Output Current | 246 أ | Nominal value under 40 °C ambient temperature |
| سعة التحميل الزائد | 110% التصنيف الحالي ل 60 ق / 150% التصنيف الحالي ل 10 ق | One overload cycle lasts 5 دقائق |
| Input Power Supply | 3-phase 380~500 V AC ±10%, 50/60 Hz ±5% | Wide voltage design compatible with domestic and overseas power grids |
| Output Frequency Range | 0 ~ 598 هرتز | Supports high-speed special motor applications |
| Fundamental Power Factor | 0.98 | Low harmonic interference to the grid and low reactive power loss |
| Nominal Overall Efficiency | ≥98% | Complies with high-efficiency drive standards to reduce operating energy consumption |
- أداء التحكم
أوضاع التحكم: DTC Direct Torque Control, V/f Scalar Control, التحكم في ناقلات الأمراض بدون مستشعر
Torque Step Response: <5 ms in open-loop mode with minor speed fluctuation under load disturbance
Speed Control Accuracy: ±10% rated slip (open-loop); ±0.01% rated speed (closed-loop)
Compatible Motor Types: Asynchronous Induction Motors, Permanent Magnet Synchronous Motors, Synchronous Reluctance Motors, High-Speed Motors
ثالثا. Mechanical and Hardware Specifications
| غرض | قيمة المعلمة |
| حجم الإطار | R8 |
| Standard Protection Class | IP20 (standard for cabinet installation) |
| Optional Protection Classes | IP21 (with cable entry box), IP55 (standalone cabinet type) |
| الأبعاد الشاملة (IP21 with Cable Entry Box) | ح 963 mm × W 681 mm × D 386 مم |
| الوزن الصافي | 58.6 كجم (IP21 version) |
| طريقة التبريد | Forced air cooling with intelligent temperature-controlled variable-speed fan for low-noise operation |
| Operating Ambient Temperature | -10 °C ~ +50 درجة مئوية; derating required above 50 درجة مئوية, maximum withstand temperature +60 درجة مئوية |
| Maximum Installation Altitude | ≤4000 m; 1% current derating per 100 m above 1000 م |
| طريقة التثبيت | Vertical wall mounting, side-by-side installation without gaps allowed |
- Standard Built-in Functions
- Safety Functions: Standard STO Safe Torque Off function with SIL 3 / PL e safety level, no additional safety relays required.
- Hardware Integration: Built-in Class C3 EMC filter, DC reactor and braking chopper, greatly reducing procurement and wiring work for peripheral accessories.
- Storage & التكليف: Removable STC storage unit for one-click migration of parameters and programs; standard multi-language assistant control panel with Chinese language support.
- Basic I/O Interfaces: 6 المدخلات الرقمية (من), 3 المخرجات الرقمية (يفعل), 2 Analog Inputs (منظمة العفو الدولية), 2 Analog Outputs (إلى), reserved expansion interface for encoders.
- Communication Capability: Built-in Modbus RTU protocol and embedded web server, supporting remote monitoring and parameter configuration over local area networks.
- Energy Efficiency Management: Built-in energy optimizer and energy consumption statistics, supporting sleep/wake-up and automatic energy-saving operation modes.
- Comprehensive Protection Mechanisms: Complete protection against overcurrent, الجهد الزائد, انخفاض الجهد, الزائد, ارتفاع درجة الحرارة, خطأ الأرض, ماس كهربائى, motor phase loss, إلخ.
- Comparison of Adjacent Models with the Same Voltage Class (-4 مسلسل)
| النموذج الكامل | Rated Output Current | CT Rated Power (480 V) | VT Rated Power (480 V) | حجم الإطار |
| ACS880-01-206A-4 | 206 أ | 110 كيلوواط | 132 كيلوواط | R7 |
| ACS880-01-246A-4 | 246 أ | 132 كيلوواط | 160 كيلوواط | R8 |
| ACS880-01-293A-4 | 293 أ | 160 كيلوواط | 200 كيلوواط | R8 |
- Core Selection Differences Between Suffix -3 و -4
Voltage suffixes must be distinguished carefully for domestic project selection to avoid mismatching motors and power grids:
| عنصر المقارنة | ACS880-01-246A-3 | ACS880-01-246A-4 |
| نطاق جهد الإدخال | 380~415 V AC | 380~500 V AC |
| Nominal Applicable Grid | Standard domestic 380 V industrial power grid | Overseas 480 V power grids, foreign-owned production lines |
| Rated Voltage of Applicable Motors | معيار 380 V domestic motors | 400/460/480 V imported / export-oriented motors |
| CT Power at 400 V | 132 كيلوواط | 132 كيلوواط |
| Full-Load Operation at 480 V | Not supported for long-term full-load running | Supports full-load operation of 160 kW-class motors |
| سيناريوهات التطبيق النموذجية | Domestic general industry, municipal engineering, علم المعادن, معالجة المياه | Supporting export complete equipment, overseas engineering projects, ship supporting systems |
> نصيحة الاختيار: Prioritize models with suffix -3 for standard domestic 380 V grids; لاحقة -4 is mandatory for export equipment and 480 V power supply scenarios.
سابعا. سيناريوهات التطبيق النموذجية
الآلات العامة: Belt conveyors, screw feeders, خلاطات, الكسارات, overhead travelling cranes
Fluid Equipment: Centrifugal fans, axial fans, centrifugal water pumps, vacuum pumps, screw compressors
Process Industry: Chemical reaction kettles, metallurgical roller tables, mine hoists, municipal water treatment, food packaging lines
سيناريوهات خاصة: Export complete sets of equipment, production line renovation for overseas factories, mine and ship projects with 480 V power supply
ثامنا. Common Fault Troubleshooting Matrix
| Fault Code | ظاهرة الخلل | السبب الجذري | Step-by-Step Solutions |
| F0001 | Output Overcurrent Trip | Short circuit of motor/cable, sudden load change, excessively short acceleration time, mismatched motor parameters | 1. Disconnect power and test insulation resistance of motor and power cables; 2. Extend acceleration time parameter; 3. Verify Group 99 motor rated parameters |
| F0002 | DC Bus Overvoltage | Excessively high grid voltage, excessively short deceleration time, disconnected or over-resistive braking resistor | 1. Measure three-phase input voltage; 2. Extend deceleration time; 3. تحقق من الأسلاك, resistance and power matching of braking resistor |
| F0011 | Motor Overload Warning / رحلة | Stuck mechanical load, motor phase loss, low overload protection setting | 1. Rotate motor shaft manually to check mechanical jamming; 2. Verify balanced three-phase motor current; 3. Check overload protection threshold parameters |
| F0021 | DC Bus Undervoltage | Input phase loss, blown fuse, loose input terminals, excessively low grid voltage | 1. Inspect three-phase input voltage and phase sequence; 2. Replace blown input fuses; 3. Tighten main circuit wiring terminals |
| F0030 | Heatsink Overtemperature | Exceeded ambient temperature, blocked cooling air duct, faulty cooling fan | 1. Clean dust on VFD air intake and cooling fins; 2. Check fan operating status; 3. Lower ambient temperature or run with derated capacity |
- Ordering and Accessories Description
The order number of the base unit shall comply with results from ABB official selection tools; suffix coding rules for all series accessories are universal.
Common accessory suffixes:
+D150: Upgrade to ACS-AP-W Bluetooth assistant control panel for wireless commissioning via mobile phones/tablets
+B056: Standard factory-matched braking resistor
+E202: Upgrade to Class C2 EMC filter for harsh electromagnetic environments
+K475: PCB conformal coated board for humid, dusty and corrosive harsh environments
+N5050: Built-in Profinet industrial Ethernet communication module
+L502: Incremental encoder interface module for high-precision closed-loop speed control
Full Packing List of Standard Factory Package for ABB ACS880-01-246A-4 (R8 Frame, IP21 Standard Unit)
- Core Main Unit (Fully Pre-Integrated from Factory)
- ACS880-01-246A-4 Wall-Mounted VFD Main Unit (R8 Frame, IP21)
Factory pre-installed standard internal hardware:
ZCU-12 Main Control Unit (equipped with standard I/O terminals, STO Safe Torque Off circuit, RS485 Modbus and USB commissioning port)
Built-in DC Choke (DCL, standard for R5~R9 frames to suppress harmonics)
Built-in braking chopper (standard for R8 frame, only external braking resistor required)
Conformal coated control board (all standard deliveries come with coated boards)
Complete main power circuit, cooling fans and power terminal copper busbars
Integrated dedicated IP21 cable entry box with separate compartments for main circuit and control cables
- ACS-AP-W Bluetooth Assistant Chinese Control Panel (معيار, Detachable)
Supports Bluetooth connection with Drive Composer commissioning software, Chinese/English language switching, parameter setting and fault log viewing.
- Matching Installation Hardware Kit (Separate Small Packaging Bag)
- Wall-mount fixing bolts and expansion screws for wall installation
- Sealing cover for cable entry box, dustproof buckles, rubber cable sealing gaskets
- Insulated protective cover for main power terminals and protective cover for control terminals
- Lifting eye bolts (special for heavy-duty R6/R7/R8 frames for transportation and hoisting)
- Extension mounting buckles for control panel (for external panel mounting on cabinet doors if needed)
ثالثا. Paper Documentation Package (Multi-Language Including Chinese)
- ACS880-01 Quick Installation and Startup Guide (Chinese Version)
- Multi-language safety warning manual (electrical safety, capacitor discharge, hoisting warnings)
- Overall dimension drawings and terminal wiring schematic diagrams
- Factory inspection certificate and product nameplate parameter sheet
- Brief instructions for optional expansion modules (fieldbus cards, encoder cards, I/O expansion cards)
- Electronic Documentation CD
Full files contained in the CD:
- Complete ACS880-01 hardware manual and firmware parameter manual (Chinese & English PDF)
- Drive Composer PC commissioning software installation package
- Supporting manuals and wiring drawings for all optional modules
- Fault code lookup document and motor parameter identification guide
- Protective Packaging Auxiliary Materials
- Reinforced factory hard carton, load-bearing wooden pallet at bottom (standard wooden pallet for heavy-duty R8 frames for forklift handling)
- Shockproof foam corner protectors and bottom buffer foam for the main unit
- Plastic moisture-proof dust wrapping film and binding straps
ملاحظة هامة: Optional Accessories Not Included in Standard Package (Separate Order Required)
- External braking resistors and braking units
- External EMC input/output filters
- Fieldbus adapters (FENA-01 بروفينيت, FPBA-01 Profibus, إلخ.)
- FEN-xx encoder interface modules, I/O expansion modules
- IP55 protection enclosure kit (order code +B056)
- Extension cables for cabinet door-mounted control panels
- Input/output AC line reactors
- Special customized kits for marine certification, explosion-proof and low-temperature applications
Supplementary Remarks
- This list applies to base units with standard IP21 wall-mounted design without additional +Bxx/Cxx special options; if +Bxx/Cxx special options are added during ordering, corresponding accessory assemblies will be included in the package.
- R8 frame (including 246A-4) features a heavy main unit with a standard wooden pallet in factory packaging; small frames R1-R5 are supplied without wooden pallets.
- ACS-AP-W control panel is a mandatory factory standard accessory and will not be shipped separately. If the economical basic ACS-AP-S panel is required as replacement, specify it during ordering.
Official Overload Capacity Parameters of ACS880-01-246A-4 (Standard Operating Conditions: 40 °C Ambient Temperature, Altitude ≤1000 m)
The overload capacity of this model is divided into two operation modes based on load characteristics: Light Overload (Variable Torque VT) and Heavy Overload (Constant Torque CT). All overload cycles last 5 دقائق, with a hardware-limited instantaneous maximum current ceiling. The marking `246A` represents the VFD’s rated output current; voltage suffixes such as -3/-4 do not alter overload current parameters, only the matching motor power.
| وضع التشغيل | Baseline Continuous Current | Overload Multiplier | Typical Matching Motor Power at 480 V | Typical Load Scenarios |
| Rated Non-Overload | 246 أ | N/A | 160 كيلوواط | General loads with stable long-term operation |
| Light Overload (VT Mode) | 234 أ | 110% | 160 كيلوواط | Square-torque loads such as fans, centrifugal pumps and screw compressors with minor short-term overload |
| Heavy Overload (CT Mode) | 206 أ | 150% | 132 كيلوواط | Impact constant-torque loads such as belt conveyors, خلاطات, crushers and hoisting mechanisms |
| Instant Startup Peak | N/A | N/A | N/A | Motor locked rotor during startup, short-term extreme impact conditions |
Key Supplementary Explanations
- Hardware Current Limit Constraint: The peak output current of all operating scenarios is capped by IGBT hardware at maximum 350 أ; ال 150% overload current of 309 A under heavy-duty mode is below this ceiling and fully deliverable.
- Derating Rules:
If ambient temperature exceeds 40 درجة مئوية, the rated output current is derated by 1% per 1 °C rise (max withstand temperature 60 درجة مئوية), with synchronous reduction of overload capacity.
If installation altitude exceeds 1000 م, the rated output current is derated by 1% per 100 m elevation gain.
- Protection Mechanism: When overload duration or current exceeds specifications, the VFD will trigger an overload warning first; sustained violation will lead to `F0011` motor overload trip, combined with heatsink overtemperature protection for dual safety coverage.
- Mode Switching: The two overload modes can be switched via parameter `22.02`. The selected mode must match actual load characteristics; prolonged operation beyond rated overload specifications accelerates aging of power components.
Full Cross-Brand Comparison Table for ABB ACS880-01-246A-4 (132 kW Heavy Duty / 246 يمثل)
Reference Unit: ACS880-01-246A-4
Core Reference Specifications: 380~500 V wide voltage, 132 kW CT heavy duty, heavy-duty rated current 206 أ, 150% الزائد ل 60 ق; 160 kW VT light duty, light-duty current 234 أ, 110% الزائد ل 60 ق; built-in DC reactor + EMC filter + braking chopper + STO safety function.
- High-End Foreign Brand Counterparts (Original Imported / Top European & American Brands, Direct Replacement for Heavy-Duty Applications)
| ماركة | النموذج الكامل | Heavy-Duty CT Rated Current | Heavy-Duty Power | Light-Duty VT Power | Core Comparison Description |
| ايه بي بي | ACS880-01-246A-4 | 206 أ | 132 كيلوواط | 160 كيلوواط | Reference unit with DTC direct drive, standard STO, built-in reactor, filter and braking unit |
| سيمنز | SINAMICS G120C 6SL3210-1KE32-4UB1 | 205 أ | 132 كيلوواط | 160 كيلوواط | Integrated compact unit with built-in STO, suitable for production lines/fans/pumps; cabinet-mounted G130 model 6SL3310-1GE32-6AA3 shares identical specifications |
| شنايدر إلكتريك | ATV630D132N4 | 202 أ | 132 كيلوواط | 160 كيلوواط | High-performance process drive with built-in DC reactor and EMC filter, standard STO, ideal for water treatment and heavy industry |
| ياسكاوا | GA800 CIPR-GA80B0260ABBA | 208 أ | 132 كيلوواط | 160 كيلوواط | High-torque vector control with excellent permanent magnet motor compatibility, dedicated for hoisting and roller table applications |
| ميتسوبيشي اليكتريك | FR-A840-03250-2-60 | 234 أ | 132 كيلوواط | 160 كيلوواط | A800 high-performance vector drive with built-in filter and multi-protocol communication, for compressors and mixing equipment |
| روكويل أتمتة | PowerFlex755 20G4ADN260AA0NNNNN | 260 أ | 132 كيلوواط | 160 كيلوواط | Matched for automated production lines with native EtherNet/IP support, for heavy-duty impact loads |
- Domestic High-End Industrial Counterparts (Domestic Replacement with Equivalent Performance & Lower Cost)
| ماركة | النموذج الكامل | Heavy-Duty CT Rated Current | Heavy-Duty Power | Light-Duty VT Power | Core Comparison Description |
| ابتكار | MD880-132-4 | 206 أ | 132 كيلوواط | 160 كيلوواط | High-end domestic industrial drive benchmarked against ACS880, DTC-like torque control, built-in braking unit, optional STO |
| Invt | CHV200-132-4 | 205 أ | 132 كيلوواط | 160 كيلوواط | Heavy-duty vector drive for mining, mixing and conveying equipment |
| Delta Electronics | CH2000 132043A | 204 أ | 132 كيلوواط | 160 كيلوواط | Universal for permanent magnet and asynchronous motors, wide 380~480 V voltage range, built-in EMC filter |
| Hervit | V6-H-4T132G | 208 أ | 132 كيلوواط | 160 كيلوواط | Special heavy-duty model for hoisting, wire drawing and mixing applications |
- Key Replacement Selection Differences & Risk Warnings
- Critical Voltage Matching Notes
Reference ACS880-01-246A-4: 380~500 V wide voltage, dedicated for export and overseas 480 V equipment;
The equivalent current model for standard domestic 380 V applications is ACS880-01-246A-3 (380~415 V).
For replacement selection, all matching models must carry suffix 4 (400 V wide voltage); narrow-range 380 V models are forbidden.
- Built-in Hardware Differences (Key Points for Retrofit Replacement)
- Standard built-in configuration of ABB ACS880: DC reactor + Class C3 EMC filter + braking chopper + ستو
- Siemens G120C and Schneider ATV630 come with standard STO, but DC reactors are mostly optional and must be purchased separately for replacement to avoid excessive harmonic distortion.
- Domestic MD880/CH2000 series feature built-in braking units, while DC reactors are optional for partial specifications.
- Core Overload Capacity Comparison (Mandatory for Heavy-Duty Applications)
ABB Reference: CT heavy-duty baseline current 206 أ, 150% الزائد (309 أ) sustainable for 60 ق
All high-end counterpart models (G120C / ATV630 / GA800 / MD880) deliver equivalent overload performance with heavy-duty current ranging from 202 A to 208 أ
Economical ATV340 / G120XA lack the 150% heavy-duty profile and only support 110% الزائد الخفيف, leading to frequent tripping under impact loads.
- Installation Dimension Reference
ACS880-01-246A-4 is R8 frame (963 × 681 × 386 مم, 58.6 كجم).
Siemens G120C and Schneider ATV630 models of identical power have smaller footprints with no cabinet expansion required for retrofits; domestic MD880 dimensions are close to ABB, allowing shared mounting cutouts.
- Quick Selection Conclusion
- Heavy Industry / Mixing / نقل / Hoisting (Constant Torque Heavy Duty): Prioritize Siemens G120C, Schneider ATV630 and Inovance MD880 for fully equivalent replacement in current rating, overload capacity and functions.
- Export Equipment / Overseas 480 V Power Supply: Must select wide-voltage models with suffix -4; narrow-range 380 V units are prohibited.
- المشجعين & مضخات (Light Duty Without Impact): Economical ATV340 and G120XA are available at lower cost.
- Demand for Original Same Platform, DTC Control and Factory Integrated Solution: Directly adopt the same series ACS880-01-246A-4.