Schneider 3CT-H3-300-C Integrated 3-Phase Current Transformer

The 3CT-H3-300-C is a through-core combined three-phase current transformer of Schneider’s 3CT series (formerly Samwha from South Korea). It is specially developed to match the EOCR series motor protectors. Adopting an integrated three-phase synchronous sampling structure, it is designed for current collection on the main circuit of three-phase motors, meeting demands for motor protection against ...

  • تفاصيل المنتج

The 3CT-H3-300-C is a through-core combined three-phase current transformer ل شنايدر’s 3CT series (formerly Samwha from South Korea). It is specially developed to match the EOCR series motor protectors. Adopting an integrated three-phase synchronous sampling structure, it is designed for current collection on the main circuit of three-phase motors, meeting demands for motor protection against overload, phase loss and locked rotor as well as current measurement. Equipped with circular through holes for cable threading and compatible with standard 35 تركيب السكك الحديدية مم DIN, it greatly saves cabinet wiring and installation space.

  1. Step-by-Step Model Code Decoding

3CT-H3-300-C

  1. 3ط م: Integrated 3-Phase Current Transformer
  2. H3: Frame code corresponding to primary current rating of 300 أ
  3. 300: Rated primary current 300 أ
  4. ج: Circular through-hole structure; models with suffix Z in the same series feature square holes for busbar application

ثالثا. المواصفات الفنية الأساسية

غرضقيمة المعلمة
Current Ratio300/5 أ
Rated Burden1.25 فرجينيا
فئة الدقةفئة الحماية 3.0
Through-hole DiameterCircular 24 مم
تحمل الجهد2 kV power frequency withstand voltage, maximum circuit voltage withstand 1150 V
Phase ConfigurationIntegrated 3-phase, synchronous sampling for three circuits
طريقة التركيبFixed on standard 35 مم DIN السكك الحديدية
الأبعاد الشاملةدبليو 150 مم * ح 71 مم
Compatible CablesCopper cables (single-core / multi-strand through-core wiring)
Matched EquipmentFull range of Schneider EOCR motor protectors (EOCR-SS / 3DE / FM, إلخ.)
Core MaterialNanocrystalline alloy, low-distortion sampling for 50 Hz ~ 1 كيلو هرتز
  1. Full Model Cross Reference for the Same Series
نموذجنسبةThrough-hole Structure
3CT-H1-100-C100/5 أType C with circular hole
3CT-HH-150-C150/5 أType C with circular hole
3CT-H2-200-C200/5 أType C with circular hole
3CT-H3-300-C300/5 أType C with circular hole
3CT-H4-400-C400/5 أType C with circular hole
3CT-H3-300-Z300/5 أType Z with square hole (for busbar only)
  1. سيناريوهات التطبيق النموذجية
  2. Complete control cabinets for industrial three-phase asynchronous motors, cooperating with EOCR protectors to realize protection against overload, خسارة المرحلة, phase unbalance and locked rotor;
  3. Current monitoring of 0.4 kV low-voltage power circuits, sampling for ammeters and multi-function meters;
  4. Control boxes for high-power motors such as water pumps, المشجعين, air compressors and conveyors;
  5. Complete electrical control systems for automatic production lines, HVAC equipment and water treatment facilities.
  6. تثبيت & Operation Maintenance Key Points
  7. Thread the three primary-side cables separately through the three circular holes, keep cables centered against the core to avoid sampling errors caused by unilateral offset;
  8. Secondary output terminals shall be reliably connected to the EOCR current sampling ports. Never open the secondary circuit, as open-circuit will generate high voltage and damage components;
  9. When multiple transformers are connected in parallel for measurement, the total impedance of secondary circuit loads shall not exceed the rated burden limit of 1.25 فرجينيا;
  10. Operating ambient temperature shall be maintained between -10℃ and +60℃, keep away from strong electromagnetic interference sources such as contactors and inverters;
  11. Tighten terminal screws after wiring, conduct regular inspections for cable insulation abrasion, overheating and discoloration.

سابعا. Troubleshooting Matrix

ظاهرة الخللالسبب الجذريحل
EOCR frequently reports false overload alarmsOff-center cable threading, loose secondary wiringRe-thread cables in center position and fasten secondary terminals
No protection trigger upon motor locked rotorBroken / open secondary circuitCut off power to check circuit continuity and repair wiring
Sampling reading deviation over 3%Long-term overload exceeding 300 A primary currentReplace transformer with higher ratio and control load current
Transformer housing overheatingContinuous overload, excessive secondary loadReduce quantity of secondary meters to match rated burden

ثامنا. Model Replacement Guidelines

  1. Same-rating replacement: 3CT-H3-300-Z only adopts square through holes, interchangeable for busbar applications; 3CT-H3-300-C is preferred for cable wiring;
  2. Cross-brand replacement: Must match 300/5 A ratio, 1.25 VA burden and integrated 3-phase structure. Separate single-phase standalone transformers cannot be directly substituted, which will trigger abnormal phase-loss protection logic.
  3. احتياطات السلامة
  4. Primary rated current shall not exceed 300 A for long-term operation; sustained overload will permanently impair core measurement accuracy;
  5. No disconnectable components such as fuses or switches are allowed on the secondary side. Cut off power of the primary main circuit before any maintenance;
  6. Reserve heat dissipation gaps during cabinet mounting; do not install closely to heat-generating components including contactors and thermal relays;
  7. Only applicable to 50 Hz power frequency low-voltage power circuits; special inverter-type transformers are required for high-frequency variable-frequency circuits;
  8. Each product is delivered with an original factory calibration label. Verify the full model before spare part replacement; frames H1/H2/H3 cannot be mixed for use.