The ACS580-01-087A-4 is a standard wall-mounted single drive unit من ايه بي بي’s ACS580 series, مُصنف لمدخل تيار متردد ثلاثي الطور 380-480 فولت. تتميز سلسلة محركات الأقراص هذه بعملية سهلة الاستخدام, الموثوقية العالية وكفاءة الطاقة الفائقة كمزايا أساسية. Multiple standard built-in functions eliminate the need for extra optional components, enabling rapid commissioning and deployment. Widely compatible with general industrial loads such as pumps, المشجعين, conveyors and mixers, it is the preferred solution for light industry, building HVAC, water treatment and other applications.
Breakdown of Model Code
Per ABB official naming convention, each segment of the model designation is defined as follows:
ACS580: معرف سلسلة المنتج, representing ABB’s general-purpose standard drive series covering power ratings from 0.75kW to 500kW
-01: Construction type, standing for wall-mounted standard single drive. Standard equipment includes IP21 enclosure rating, Assistant Control Panel, built-in Class C2 EMC filter, إيقاف عزم الدوران الآمن (ستو), braking chopper and triple-protection coated circuit boards
-087أ: Rated output current marking, indicating the nominal rated output current of the drive is 87A
-4: فئة الجهد, denoting three-phase 380V–480V AC input, compatible with 50/60Hz mains power grids
المواصفات الفنية الأساسية
التقييمات الكهربائية
| المعلمة | مواصفة | ملاحظات |
| نطاق جهد الإدخال | 3-phase AC 380V ~ 480V | Tolerance: +10% / -15% |
| تردد الإدخال | 50/60هرتز | Tolerance: ±5% |
| تصنيف الانتاج الحالي | 87أ | Nominal value for light-duty applications |
| قوة المحرك المتطابقة (Light Duty) | 45كيلوواط | For variable-torque loads (المشجعين, مضخات المياه) |
| قوة المحرك المتطابقة (واجب ثقيل) | 37كيلوواط | For constant-torque loads (نقل, mixing) |
| نطاق تردد الإخراج | 0 ~ 500Hz | Supports high-speed motor operation |
| Input Power Factor | ≥0.98 | High power factor across full power range |
| Overall Efficiency | ≥98% | At rated operating conditions |
| سعة التحميل الزائد | 150% التصنيف الحالي لمدة 60 ثانية | One overload cycle permitted every 10 دقائق |
| 110% rated current continuously |
يتحكم & Interface Specifications
Motor Control Modes: Scalar V/F control, التحكم في ناقلات الأمراض بدون مستشعر; compatible with induction motors, permanent magnet synchronous motors and synchronous reluctance motors
الأبعاد المادية & المواصفات البيئية
حجم الإطار: R5
الأبعاد الشاملة (H × W × D): 896mm × 345mm × 293mm
الوزن الصافي: تقريبا. 23كجم
تصنيف الضميمة: IP21 (معيار); IP55 high-protection version available as option
نوع التركيب: Wall mounting, side-by-side compact installation supported
درجة حرارة التشغيل المحيطة: -15درجه مئوية ~ +50 درجه مئوية (التخفيض مطلوب فوق 40 درجة مئوية)
تخزين & درجة حرارة النقل: -40درجه مئوية ~ +70 درجه مئوية
الرطوبة النسبية: 5% ~ 95%, غير التكثيف
Altitude Rating: Full power output up to 1000m; 1% power derating per additional 100m above 1000m
رمز النظام المنسق: 85044088
Standard Configuration & الملحقات الاختيارية
Factory Standard Equipment
- ACS-AP-S Assistant Control Panel (Chinese language supported)
- Built-in Class C2 EMC Filter
- Integrated Braking Chopper
- إيقاف عزم الدوران الآمن (ستو) وظيفة
- Triple-protection Coated Printed Circuit Boards
- Bottom Cable Entry Compartment
- Multilingual Quick Installation & دليل التكليف
Common Optional Accessories
Enclosure Upgrade: IP55 protective enclosure, flange mounting kit
Communication Extensions: Fieldbus adapters including Profibus DP, Profinet IO, إيثرنت/IP, مودبوس تكب
Electrical Options: Input reactors, output reactors, du/dt filters, sine-wave filters, braking resistors
Functional Extensions: I/O expansion modules, temperature sensor interface cards, NETA-21 remote monitoring module
Software Tools: Drive Composer professional commissioning software
سيناريوهات التطبيق النموذجية
صناعة معالجة المياه: Clean water pumps, sewage pumps, مراوح التهوية, sludge mixers
Building HVAC: Chilled water pumps, cooling water pumps, supply & exhaust fans for central air conditioning
Light Manufacturing: سيور ناقلة, packaging production lines, mixing & blending equipment, ضواغط الهواء
علم المعادن & التعدين: Dust extraction fans, material transport belts, mine drainage pumps
الهندسة البلدية: Water supply pumping stations, ventilation systems for wastewater treatment plants
مصفوفة استكشاف الأخطاء وإصلاحها المشتركة
| ظاهرة الخلل | Root Causes | الإجراءات العلاجية خطوة بخطوة |
| Overcurrent Trip (رمز الخطأ 0001) | Short circuit in motor/cables, sudden load surge, overly short acceleration time | 1. Cut power and test insulation & wiring of motor and power cables |
| 2. Appropriately extend acceleration time parameter | ||
| 3. Verify consistency between motor rated parameters and drive settings | ||
| DC Overvoltage Trip (رمز الخطأ 0002) | Excessively high mains voltage, overly short deceleration time, faulty braking circuit | 1. Measure input mains voltage to confirm it falls within allowable range |
| 2. Extend deceleration time or enable DC braking function | ||
| 3. Check wiring and resistance value of braking resistor for matching | ||
| رحلة انخفاض الجهد (رمز الخطأ 0003) | Single-phase power loss, blown input fuses, excessively low mains voltage | 1. Inspect three-phase input power to eliminate phase loss issues |
| 2. Check status of input fuses / قواطع الدائرة | ||
| 3. Confirm on-site mains voltage meets equipment requirements | ||
| Motor Overload Alarm (رمز الخطأ 0005) | Jammed mechanical load, معلمات المحرك غير الصحيحة, sustained overload operation | 1. Cut power and rotate motor shaft manually to check mechanical smoothness |
| 2. Re-run motor identification auto-tune | ||
| 3. Evaluate actual load conditions and upsize drive model if necessary | ||
| Overheating Fault (رمز الخطأ 0009) | ارتفاع درجة الحرارة المحيطة بشكل مفرط, blocked cooling air ducts, faulty cooling fan | 1. Clear dust buildup on drive air intake cooling grille |
| 2. Verify normal operation of cooling fan | ||
| 3. Improve cabinet ventilation and lower ambient temperature |
Detailed List of Standard Accessories for ABB ACS580-01-087A-4 (Frame R5 / IP21 Version)
This model is a standard wall-mounted unit of ACS580 Frame R5. Factory supply contents are split into built-in onboard functions and physical accessories supplied in carton. Below is a detailed breakdown of the official standard supply scope:
- Standard Built-in Onboard Functions (Integrated, No Extra Fitting Required)
All functions below are factory pre-configured and ready for direct use without purchasing extra options:
- EMC Components: Built-in Class C2 EMC filter to meet industrial site electromagnetic compatibility requirements
- Braking Circuit: Integrated braking chopper allowing direct connection of braking resistors for fast deceleration
- وظيفة السلامة: إيقاف عزم الدوران الآمن (ستو) compliant with PL e / سيل 3 safety level
- حماية البيئة: Full triple-protection coating on control and power boards, resistant to humid, dusty and corrosive gas environments
- Standard Control Interfaces: 6 المدخلات الرقمية, 2 digital outputs, 2 المدخلات التناظرية, 1 الإخراج التناظري
- Basic Communications: Embedded RS-485 hardware port with native Modbus RTU protocol support
- التصميم الهيكلي: Bottom cable entry compartment supporting standardized wiring and cable ingress protection
- Physical Standard Carton Accessories (Separately Packed Inside Shipment Box)
Independent accessories available upon unpacking for installation and basic commissioning:
- ACS-AP-S Assistant Control Panel (Chinese version): Equipped with LCD screen and full-function keys for parameter setup, status monitoring and fault diagnosis; pluggable onto drive front panel and supplied in separate packaging
- Wall Mounting Template: 1:1 paper drilling positioning template for marking mounting hole positions on-site to reduce drilling errors
- Cable Junction Box Assembly: Standard for Frame R5 IP21 units, including power cable grounding brackets, control cable shielding clamps and assembly fasteners
- Mounting Fastener Kit: M6 bolts, nuts and other metal hardware for wall mounting fixation
- Ground Terminals & Cable Crimp Accessories: Dedicated main circuit grounding terminals and auxiliary crimp fittings for control terminals
ثالثا. Supplied Documentation & Identification Labels
- Quick Installation and Startup Guide: Multilingual edition (including Chinese) covering full procedures of wiring, power-up and basic commissioning
- Safety Warning Stickers: Multilingual residual voltage warning labels to be affixed near equipment to alert maintenance personnel
- Product Certificate of Conformity and Warranty Document
ملحوظة: Full hardware manuals and firmware parameter manuals are not supplied as standard; downloadable via ABB official website or available as separate printed copies upon order.
- Packaging Auxiliary Protection Materials
Standard industrial shipping packaging for logistics protection, not classified as drive accessories:
VCI vapor corrosion inhibitor anti-rust bag
Paper buffer liners and corner protectors
Strapping bands
Shipping pallet (for full carton industrial packaging specifications)
- Non-Standard Optional Components Requiring Separate Ordering
Items below are excluded from standard supply scope and must be purchased separately per project demands:
Enclosure Upgrade: IP55 protective enclosure, flange mounting kit
Communication Extensions: Fieldbus adapters including Profibus DP, Profinet IO, إيثرنت/IP, مودبوس تكب
Electrical Matching Components: Input reactors, output reactors, du/dt filters, sine-wave filters, braking resistors
Functional Extensions: I/O expansion modules, encoder interface cards, temperature sensor interface cards, remote monitoring modules
Software Tools: Drive Composer professional commissioning software, USB commissioning cable