Schneider GV2P32 Motor Circuit Breaker

The GV2P32 is a 3-pole thermal-magnetic motor circuit breaker (MPCB) from Schneider TeSys GV2 series. It features an adjustable current setting of 24-32A, compatible with 15kW @ 400V three-phase motors. Providing dual protection against overload and short circuit, with IP20 protection degree, it is widely applied in industrial motor control circuits. Model Code Explanation Code ...

  • تفاصيل المنتج

The GV2P32 is a 3-pole thermal-magnetic motor circuit breaker (MPCB) from Schneider TeSys GV2 series. It features an adjustable current setting of 24-32A, compatible with 15kW @ 400V three-phase motors. Providing dual protection against overload and short circuit, with IP20 protection degree, it is widely applied in industrial motor control circuits.

  1. شرح كود النموذج
مقطع الكودمعنىوصف
GV2سلسلة المنتجاتTeSys GV2 series motor circuit breakers for motor overload and short-circuit protection
صنوع العمليةRotary knob manual control, imported version (domestic equivalent: GV2PM series)
32التقييم الحاليAdjustable setting range: 24-32أ, for motor circuits with rated current up to 32A

تعريف النموذج الكامل: GV2P32 = Schneider GV2 series, rotary knob type, 32A rated motor circuit breaker

  1. المواصفات الفنية الأساسية
فئةتحديدملاحظات
General Characteristics
نوع المنتج3-pole thermal-magnetic motor circuit breaker (MPCB)متوافق مع IEC 60947-4-1
النطاق الحالي قابل للتعديل24-32أ (قابل للتعديل)Thermal trip with ambient temperature compensation
البولنديين3ص (ثلاث مراحل)Designed for three-phase motor protection
وضع التشغيلRotary knob manual controlWith ON/OFF indicator and lockable function
المعلمات الكهربائية
تصنيف الجهد التشغيلي230-690الخامس و, 50/60هرتزSuitable for global industrial power grids
Compatible Motor Power15kW @ 400/415V, 50/60هرتزMaximum applicable power under standard operating conditions
Magnetic Trip Threshold12×In = 384A (Instant short-circuit protection)Fast disconnection upon short-circuit faults
Short-circuit Breaking Capacity10kA @ 400V, 50هرتزMeets industrial standard requirements
نوع المحطةمحطات المسمارApplicable copper wire cross-section: 1.5-25مم²
بدني & المعلمات البيئية
درجة الحمايةIP20Prevents finger access to live parts
نوع التركيبسكة DIN القياسية مقاس 35 ممModular installation, توفير المساحة
أبعاد (العرض × الارتفاع × العمق)45×85×95mmCompact design for distribution cabinets
درجة حرارة التشغيل-25درجه مئوية ~ +60 درجه مئويةنطاق درجة حرارة واسعة للبيئات الصناعية
الشهاداتسي سي سي, أول, وكالة الفضاء الكندية, مجموعة شرق أفريقيا, Marine Classification (DNV, جي إل, BV), اتيكسMultiple certifications for global application
طلب المعلومات
Manufacturer Part No.GV2P32Official Schneider model
رمز الطلب القياسيGV2P32Original imported version
  1. Full GV2P Series Model List
نموذجالنطاق الحالي قابل للتعديلCompatible Motor Power (400V)تيار الرحلة المغناطيسي
GV2P010.16-0.25أ0.06كيلوواط3.0أ
GV2P020.25-0.4أ0.12كيلوواط4.8أ
GV2P030.4-0.63أ0.25كيلوواط7.6أ
GV2P040.63-1أ0.37كيلوواط12أ
GV2P051-1.6أ0.75كيلوواط19أ
GV2P061.6-2.5أ1.1كيلوواط30أ
GV2P072.5-4أ1.5كيلوواط48أ
GV2P084-6.3أ3كيلوواط76أ
GV2P096.3-10أ4كيلوواط120أ
GV2P1010-16أ7.5كيلوواط190أ
GV2P1413-18أ11كيلوواط216أ
GV2P1616-24أ11كيلوواط288أ
GV2P2020-32أ15كيلوواط384أ
GV2P3224-32أ15كيلوواط384أ
GV2P4032-40أ18.5كيلوواط480أ
  1. نماذج الاستبدال & Competitor Comparison

4.1 Internal Schneider Replacements

النموذج الأصلينموذج الاستبدالالاختلافاتسيناريوهات التطبيق
GV2P32 (مستورد)GV2PM32C (محلي)Different origin, minor certification differences; عمق: 91مم (GV2P: 95مم)Domestic projects, cost-sensitive applications, CCC certification required
GV2P32GV2ME32 (Domestic push-button type)عملية الضغط على زر, المعلمات الكهربائية متطابقةApplications requiring push-button control, limited budget
GV2P32GV3P32 (Upgraded series)Higher breaking capacity and enhanced functionsEnvironments with high short-circuit risk, advanced protection required

4.2 Cross-brand Competitor Comparison

ماركةنموذجالنطاق الحاليالبولنديينMagnetic Trip Ratioالاختلافات الرئيسية
شنايدرGV2P3224-32أ12×فيMultiple certifications including marine approval, IP20
ايه بي بيMS325-3224-32أ12×فيكسر القدرة: 15ال, larger dimensions
سيمنز3RV2031-4KA1024-32أ13×فيOptional electronic trip, سعر أعلى
إيتونPKZM0-3224-32أ12×فيSpring terminals for easy installation
شينتNM1-63S/330025-32أ10×فيCost advantage, البديل المحلي
  1. Application Environments & الحالات النموذجية

5.1 التطبيقات الموصى بها

التحكم بالمحركات الصناعية: Main circuit protection for three-phase motors such as pumps, المشجعين, compressors and conveyors

معدات تصنيع المعدات الأصلية: Supporting machine tools, آلات التعبئة والتغليف, printing machines and textile machinery

بناء الأنظمة الكهربائية: Protection for critical motors including air conditioning units, fire water pumps and drainage pumps

Marine & Offshore Engineering: Compliant with marine classification standards for ship power systems

Hazardous Areas: ATEX certified for motor protection in non-explosion-proof zones

5.2 التطبيقات غير الموصى بها

Single-phase Motors: 3-pole design not suitable for single-phase circuit protection

Frequent Start-Stop Operations: أكثر من 10 cycles per hour will shorten service life

High Altitude (>2000م): Derating required (10% reduction per 1000m rise)

Severe Vibration Environments: Extra reinforcement needed to avoid false tripping

Corrosive Environments: IP20 protection is insufficient; additional enclosure is required

5.3 حالات التطبيق النموذجية

قضية 1: Water Treatment Plant Pump Protection

معدات: 3 sets of 15kW submersible three-phase pumps (400V)

إعدادات: GV2P32 + LC1D32 Contactor + LRD3322 Thermal Overload Relay (حماية زائدة عن الحاجة)

حصيلة: Prevented 3 motor overload faults and 1 short-circuit fault, إطالة عمر خدمة المعدات عن طريق 2 سنين

قضية 2: Conveyor System in Automobile Manufacturing Plant

معدات: 12 conveyor lines each equipped with 15kW motor

إعدادات: GV2P32 linked with Schneider PLC

سمات: Rotary knob enables quick on-site reset and reduces downtime

  1. استكشاف الأخطاء وإصلاحها & Maintenance Manual

6.1 الأخطاء الشائعة & الحلول

ظاهرة الخللالأسباب المحتملةالحلول
Frequent thermal tripping1. الزائد للمحرك1. Check motor load and eliminate mechanical jamming
2. Improper low current setting2. Set current to 1.1 times motor Full Load Current (FLA)
3. ارتفاع درجة الحرارة المحيطة بشكل مفرط3. تحسين التهوية وخفض درجة الحرارة المحيطة
4. Loose terminals causing overheating4. Inspect and tighten terminals
Instant magnetic tripping1. Circuit short circuit1. Power off and test circuit insulation
2. Damaged motor winding insulation2. Measure winding resistance and replace faulty motor
3. Arc short circuit inside contactor3. Inspect contactor contacts and replace if necessary
الفشل في الإغلاق1. Tripping mechanism not reset1. Turn knob to OFF position then re-close
2. Damaged rotary knob2. Check knob linkage and replace damaged parts
3. Internal mechanical failure3. Arrange professional maintenance or replace the breaker
No output after closing1. Burned internal contacts1. خارج السلطة, inspect main contacts and replace defective unit
2. الأسلاك غير الصحيحة2. Verify wiring to ensure correct three-phase connection
3. Faulty tripping mechanism3. Check tripping mechanism and replace if needed

6.2 Maintenance Procedures

  1. التفتيش اليومي (أسبوعي)

Check knob position and status indication

Look for abnormal heat, odor or noise

Confirm all terminals are tightly connected

  1. الصيانة الروتينية (كل 6 شهور)

Power off and remove dust with dry compressed air

Inspect main contacts for burning and oxidation

Test tripping function by simulating overload and short circuit conditions

  1. Annual Maintenance

Check lubrication of internal mechanical components

Verify accuracy of current setting

Retighten all electrical connections

6.3 Quick Diagnosis Tips

Thermal trip? Check load and current setting.

Magnetic trip? Locate short circuit and test insulation.

Fail to close? Reset first; replace for mechanical faults.

No output? Inspect contacts and wiring.

  1. اختيار & إرشادات التثبيت

7.1 قواعد الاختيار

المطابقة الحالية: Motor FLA must fall within 24-32A; recommended setting: FLA × 1.1

مطابقة الطاقة: Standard solution for 15kW @ 400V three-phase motors

Protection Coordination: Use with contactors and fuses to ensure selective protection

Ambient Derating: ديراتي 1% per ℃ above 40℃

7.2 ملاحظات التثبيت

Mounting Direction: التثبيت العمودي (allowable deviation: ±15°) for normal tripping operation

Clearance: Reserve 10mm space on left & right sides, 20mm on top & bottom for heat dissipation

Wiring Standard: Copper wire with cross-section 1.5-25mm²; تشديد عزم الدوران: 6-8نانومتر

Locking Function: Padlock can be fitted to prevent accidental operation, complying with safety regulations

  1. Production Status & ترقية الحلول

Current Status of GV2P32: In production, no discontinuation plan (as of June 2026)

يرقي & خيارات الاستبدال:

  1. Functional Upgrade: GV3P32 (higher breaking capacity and extra protection functions)
  2. البديل المحلي: GV2PM32C (lower cost with equivalent performance)
  3. ترقية ذكية: TeSys T series (with communication for remote monitoring)