Model Segment Definition
Full model analysis: FX5U-32MT-XX
| Segment | Bedeutung | Beschreibung |
| FX | Base series code | Mitsubishi FX series compact PLC |
| 5U | Series generation & Typ | 5th-generation iQ-F series; U = Standard CPU (differentiated from UC compact type) |
| 32 | Total I/O points | 32 points total (16 inputs / 16 outputs) |
| M | Power supply type | M = Mixed power (AC/DC); D = DC24V power |
| T | Ausgabetyp | T = Transistor output (sink/source); R = Relay output |
| XX | Suffix code | Terminal type / specification: |
| – /DS: Gleichstrom + Schraubklemme | ||
| – /ES: AC power + Schraubklemme | ||
| – /ESS: AC power + Spring terminal | ||
| – /DSS: Gleichstrom + Spring terminal |
- Core Specification Parameter Table
2.1 Basic Performance
| Parameter | Spezifikation | Bemerkungen |
| CPU Processor | 32-bit RISC | High-speed operation, Basic instruction: 0.065渭s/step |
| Program Memory | 64KB (max expandable to 16MB) | SD card expansion supported |
| Data Memory | 32KB (expandable) | Includes file registers, special registers, usw. |
| I/O Control Mode | Cyclic scan + Interrupt | Supports high-speed response processing |
| Max I/O Points | Local 256 + Remote 256 = 512 Punkte | Bis zu 16 expansion modules connectable |
| Nennleistung | AC100-240V (ES/ESS) or DC24V (DS/DSS) | Voltage fluctuation 卤10%, 50/60Hz |
| Stromverbrauch | Ca. 30W (ES type) / 15W (DS type) | Subject to specific model |
2.2 I/O Configuration (16IN / 16OUT)
| Typ | Spezifikation | Channel Characteristics |
| Digitaler Eingang | 16-point DC24V, Sink/Source compatible | X0-X17; Response time 0.05~10ms adjustable; Input impedance 3k惟; Input current 4.7mA |
| Digitaler Ausgang | 16-point Transistor (NPN/PNP optional) | Y0-Y17; Max load 2A/point, 16A/common terminal; Response time 0.1ms; High-speed pulse output supported |
| Built-in Analog | 2KI + 1ZUM | Eingang: 12-bit, 0-10V/4-20mA |
| Ausgabe: 12-bit, 0-10V/4-20mA |
2.3 High-Speed Function & Positionierung
| Funktion | Spezifikation | Anwendungsszenario |
| High-Speed Counter | Max 6ch × 200kHz + 2ch × 10kHz | Pulse counting, frequency measurement |
| Impulsausgang | 4-axis × 200kHz (Y0-Y3) | Stepper / Servo positioning control |
| Positioning Function | Linear interpolation, Circular interpolation, Electronic gear / Cam | Multi-axis synchronous control |
| High-Speed Interrupt | Multiple interrupt sources supported (Eingang / Timer / Kommunikation) | Real-time response for critical events |
2.4 Kommunikationsschnittstellen
| Schnittstellentyp | Quantity | Spezifikation | Protocol Support |
| Ethernet | 1 Hafen | RJ45, 10/100Mbit/s | Modbus TCP, MC Protocol, SLMP, EtherNet/IP |
| RS-485 | 1 Hafen | Terminal block, 2-wire/4-wire selectable | Modbus RTU, Non-protocol communication |
| Erweiterungsport | 1 Hafen | Dedicated expansion bus | Connect FX5 series expansion & special function modules |
- Accessory List
3.1 Erweiterungsmodule
| Module Type | Empfohlenes Modell | Funktionsbeschreibung |
| Digital I/O Expansion | FX5-16ER/ES, FX5-32ER/ES | 16/32-point relay output expansion |
| Digital I/O Expansion | FX5-16ET/ES, FX5-32ET/ES | 16/32-point transistor output expansion |
| Analog Expansion | FX5-4AD, FX5-4DA | 4-channel analog input/output expansion |
| Temperature Module | FX5-4AD-TC, FX5-4AD-PT | 4-channel Thermocouple/RTD input |
| Communication Module | FX5-ENET/IP, FX5-232-BD | Ethernet expansion, RS-232 communication expansion |
| Positioning Module | FX5-1PG, FX5-20PG | 1-axis/2-axis pulse positioning expansion (Max 500kHz) |
3.2 Leistung & Connection Accessories
| Zubehörtyp | Modell | Zweck |
| Memory Backup Battery | FX3U-32BL | Power-off retention for program & Daten (Service life approx. 5 Jahre) |
| Expansion Power Module | FX5-C1PS-5V | Power supply for FX5U (DC-Typ) expansion modules |
| Bus Converter | FX5-CNV-BUS | Compatibility conversion for FX5 to FX3 series modules |
| SD Memory Card | Max 32GB | Program storage, Datenprotokollierung, firmware upgrade |
| Mounting Rail | DIN standard rail | 35mm Breite, for PLC main unit & module installation |
| Terminal Cover | Original factory part | Protect I/O terminals against dust and short circuit |
3.3 Programming & Debugging-Tools
| Tool Type | Modell | Funktion |
| Programming Software | GX Works3 | Supports Ladder Diagram, SFC, ST and other languages; Version V1.047Z or above required |
| Programming Cable | USB-SC09-FX | Connect PC to PLC programming port (RS-422) |
| Ethernet Cable | CAT5e & above | For Ethernet communication and programming |
| Handheld Programmer | FX5U-USB-PRG | On-site quick debugging and program modification |
- Competitor Replacement / Cross-Brand Comparison
| Marke | Äquivalentes Modell | Hauptunterschiede | Anwendungsszenario |
| Siemens | S7-1214C DC/DC/DC | • Native Profinet, stronger network capability | Automation production line, multi-PLC networking, SCADA connection |
| • Price 1.5~2 times of FX5U | |||
| • TIA Portal has steep learning curve | |||
| Schneider | M241 CPU 16T | • Built-in Modbus TCP/RTU, CANopen supported | Small process industry, Gebäudeautomation |
| • Weak motion control performance | |||
| • Price close to FX5U | |||
| Omron | CP1H-X40DT-D | • 4-channel built-in analog I/O | Hybrid control, small automated equipment |
| • Equivalent high-speed counting / pulse output performance | |||
| • User-friendly CX-One software | |||
| Innovation | H5U-32MT-XP | • Domestic alternative, price ~70% of FX5U | Kostensensible Projekte, domestic replacement demand |
| • Compatible with Mitsubishi instruction system | |||
| • EtherCAT bus supported | |||
| Delta | DVP-32ES200T | • Lower price (~60% of FX5U) | Standalone simple control, budget-limited projects |
| • Simplified functions, weak high-speed performance | |||
| • Fewer communication interfaces |
- Auswahlrichtlinien & Alternative Lösungen
5.1 Core Selection Criteria
| Auswahldimension | Empfohlene Konfiguration | Not Recommended Scenario |
| I/O Points | 16IN/16OUT, ideal for small equipment | Über 32 points requires expansion; recommend FX5U-64MT directly |
| Ausgabetyp | Transistor output for high-speed switching & pulse control | Large inductive load with frequent on-off; choose FX5U-32MR relay type |
| Leistungstyp | • Industrial mains: AC-Typ (ES/ESS) | Voltage fluctuation site requires voltage stabilizer |
| • Mobile/Battery supply: DC-Typ (DS/DSS) | ||
| Communication Requirement | Built-in Ethernet + RS485 meets most scenarios | Profibus, DeviceNet and other buses need expansion modules |
| Bewegungssteuerung | 4-axis 200kHz pulse output for small positioning | Über 4 axes or higher frequency (>500kHz); use FX5U + positioning module |
| Terminal Type | • Vibration environment: Spring terminal (ESS/DSS) | Frequent wiring replacement; recommend spring terminal |
| • Normal environment: Schraubklemme (ES/DS) |
5.2 Recommended Alternative Solutions
| Anwendungsszenario | Best Replacement Model | Grund |
| Cost Priority | Inovance H5U-32MT-XP | Similar functions, ~30% price reduction, good domestic technical support |
| Enhanced Network | Siemens S7-1214C | Stronger Profinet capability, suitable for production line integration |
| I/O Expansion Demand | FX5U-64MT | 64 I/O points onboard, reduce expansion module cost |
| High Analog Demand | FX5U-32MT+FX5-4AD+FX5-4DA | Expand to 6AI + 5ZUM |
| Enhanced Motion Control | FX5U-32MT+FX5-20PG | Add 2-axis 500kHz high-speed positioning |
| Kompaktes Design | FX5UC-32MT/DSS | ~30% smaller size, suitable for limited installation space |
5.3 Wichtige Anmerkungen
- Software Compatibility: Must use GX Works3 V1.047Z or higher; incompatible with GX Developer.
- Firmware Upgrade: Regularly update CPU firmware for latest functions and security patches.
- Expansion Limit: Max 16 expansion modules connected; total I/O points ≤ 512.
- Communication Setting: Default Ethernet IP: 192.168.3.3; modifiable via software or DIP switch.
- Power Capacity: DC24V service power max output 400mA; additional external power required with many expansion modules.
Mitsubishi FX5U-32MT is a 16-input/16-output transistor CPU of iQ-F series. It features high-speed operation (0.065μs/step), built-in analog I/O (2AI+1AO), 4-axis 200kHz positioning and dual communication ports (Ethernet+RS485). It is widely applied to standalone control of small automated equipment, Verpackungsmaschinen, dispensing machines, usw.
Bei der Auswahl, choose the proper suffix model according to power type, terminal preference, communication and motion control requirements, and configure expansion modules reasonably to meet specific application demands.
Mitsubishi Compact PLC Model List (Full Classification)
This document sorts Mitsubishi FX series compact PLCs from latest to legacy, covering three major categories: iQ-F Series (FX5), MELSEC-F Series (FX3), and Classic Series (FX2N/FX1N/FX1S). It includes model structure, core specifications and application scenarios for easy selection and comparison.
- MELSEC iQ-F Series (FX5) – New Generation High-Performance Compact PLC
1.1 Modellbenennungsregel
FX5[Serie]-[I/O Points][Ausgabetyp]/[Leistung & Terminal Type]
| Segment | Bedeutung | Optional Code |
| FX5 | Base series | FX5S (Standard), FX5U (High-Performance), FX5UC (Kompakt), FX5UJ (Wirtschaft) |
| I/O Points | Total input & output points | 16/24/32/40/64/80 |
| Ausgabetyp | Output mode | M=Mixed output (partial models), R=Relay output, T=Transistor output (Sink/Source) |
| Leistung & Terminal | Stromversorgung & wiring type | ES=AC+Screw terminal, ESS=AC+Spring terminal, DS=DC+Screw terminal, DSS=DC+Spring terminal |
1.2 Complete Model List
FX5S Series (Standard, Non-expandable)
| Modell | I/O Configuration | Ausgabetyp | Power/Terminal | Kernfunktionen |
| FX5S-16MR/ES | 8IN/8OUT | Relais | AC/Screw | Grundtyp, no built-in analog |
| FX5S-16MT/ES | 8IN/8OUT | Transistor | AC/Screw | Grundtyp, high-speed pulse output supported |
| FX5S-24MR/ES | 12IN/12OUT | Relais | AC/Screw | 2-channel built-in analog input |
| FX5S-24MT/ES | 12IN/12OUT | Transistor | AC/Screw | 2-channel analog input, 2-axis 100kHz pulse output |
| FX5S-30MR/ES | 16IN/14OUT | Relais | AC/Screw | 2-channel built-in analog input |
| FX5S-30MT/ES | 16IN/14OUT | Transistor | AC/Screw | 2-channel analog input, 2-axis 100kHz pulse output |
| FX5S-40MR/ES | 24IN/16OUT | Relais | AC/Screw | 2AI+1AO built-in analog |
| FX5S-40MT/ES | 24IN/16OUT | Transistor | AC/Screw | 2AI+1AO analog, 2-axis 100kHz pulse output |
FX5U Series (High-Performance, Expandable)
| Modell | I/O Configuration | Ausgabetyp | Power/Terminal | Kernfunktionen |
| FX5U-32MR/ES | 16IN/16OUT | Relais | AC/Screw | 2AI+1AO, 4-axis 200kHz pulse output |
| FX5U-32MT/ES | 16IN/16OUT | Transistor | AC/Screw | 2AI+1AO, 4-axis 200kHz pulse output |
| FX5U-64MR/ES | 32IN/32OUT | Relais | AC/Screw | 2AI+1AO, 4-axis 200kHz pulse output |
| FX5U-64MT/ES | 32IN/32OUT | Transistor | AC/Screw | 2AI+1AO, 4-axis 200kHz pulse output |
| FX5U-80MR/ES | 40IN/40OUT | Relais | AC/Screw | 2AI+1AO, 4-axis 200kHz pulse output |
| FX5U-80MT/ES | 40IN/40OUT | Transistor | AC/Screw | 2AI+1AO, 4-axis 200kHz pulse output |
| FX5U-32MR/ESS | 16IN/16OUT | Relais | AC/Spring | Spring terminal, vibration resistance |
| FX5U-32MT/ESS | 16IN/16OUT | Transistor | AC/Spring | Spring terminal, vibration resistance |
| FX5U-32MR/DS | 16IN/16OUT | Relais | DC/Screw | DC24V power, suitable for mobile equipment |
| FX5U-32MT/DS | 16IN/16OUT | Transistor | DC/Screw | DC24V power, suitable for mobile equipment |
FX5UC Series (Kompakt, Expandable)
| Modell | I/O Configuration | Ausgabetyp | Power/Terminal | Kernfunktionen |
| FX5UC-32MR/DSS | 16IN/16OUT | Relais | DC/Spring | ~30% smaller size, built-in Ethernet+RS485 |
| FX5UC-32MT/DSS | 16IN/16OUT | Transistor | DC/Spring | ~30% smaller size, built-in Ethernet+RS485 |
| FX5UC-64MR/DSS | 32IN/32OUT | Relais | DC/Spring | ~30% smaller size, built-in Ethernet+RS485 |
| FX5UC-64MT/DSS | 32IN/32OUT | Transistor | DC/Spring | ~30% smaller size, built-in Ethernet+RS485 |
FX5UJ Series (Wirtschaft, Expandable)
| Modell | I/O Configuration | Ausgabetyp | Power/Terminal | Kernfunktionen |
| FX5UJ-24MR/ES | 14IN/10OUT | Relais | AC/Screw | Simplified FX5U, lower price |
| FX5UJ-24MT/ES | 14IN/10OUT | Transistor | AC/Screw | Simplified FX5U, lower price |
| FX5UJ-48MR/ES | 28IN/20OUT | Relais | AC/Screw | Simplified FX5U, lower price |
| FX5UJ-48MT/ES | 28IN/20OUT | Transistor | AC/Screw | Simplified FX5U, lower price |
- MELSEC-F Series (FX3) – Mature & Stable Compact PLC
2.1 Modellbenennungsregel
| Segment | Bedeutung | Optional Code |
| FX3 | Base series | FX3S(Standard), FX3G(Enhanced), FX3U(High-Performance), FX3GC(Kompakt), FX3UC(Ultra-Compact) |
| I/O Points | Total I/O points | 14/24/40/64/80/128 |
| Ausgabetyp | Output mode | M=Mixed, R=Relay, T=Transistor |
| Leistungstyp | Stromversorgung | AC=AC100-240V, DC=DC24V |
| Special Function | Extra feature | ES=Screw terminal, ESS=Spring terminal, D=DC power, -ADP=Special adapter |
2.2 Complete Model List
FX3S Series (Standard, Non-expandable)
| Modell | I/O Configuration | Ausgabetyp | Leistung | Kernfunktionen |
| FX3S-14MR/ES | 8IN/6OUT | Relais | Wechselstrom | Grundtyp, no expansion capability |
| FX3S-14MT/ES | 8IN/6OUT | Transistor | Wechselstrom | Grundtyp, no expansion capability |
| FX3S-24MR/ES | 16IN/8OUT | Relais | Wechselstrom | 2-channel built-in analog input |
| FX3S-24MT/ES | 16IN/8OUT | Transistor | Wechselstrom | 2-channel built-in analog input |
| FX3S-30MR/ES | 16IN/14OUT | Relais | Wechselstrom | 2-channel built-in analog input |
| FX3S-30MT/ES | 16IN/14OUT | Transistor | Wechselstrom | 2-channel built-in analog input |
FX3G Series (Enhanced, Expandable)
| Modell | I/O Configuration | Ausgabetyp | Leistung | Kernfunktionen |
| FX3G-24MR/ES | 14IN/10OUT | Relais | Wechselstrom | Expandable to 128 Punkte, built-in Ethernet |
| FX3G-24MT/ES | 14IN/10OUT | Transistor | Wechselstrom | Expandable to 128 Punkte, built-in Ethernet |
| FX3G-40MR/ES | 24IN/16OUT | Relais | Wechselstrom | Expandable to 128 Punkte, built-in Ethernet |
| FX3G-40MT/ES | 24IN/16OUT | Transistor | Wechselstrom | Expandable to 128 Punkte, built-in Ethernet |
| FX3G-60MR/ES | 36IN/24OUT | Relais | Wechselstrom | Expandable to 128 Punkte, built-in Ethernet |
| FX3G-60MT/ES | 36IN/24OUT | Transistor | Wechselstrom | Expandable to 128 Punkte, built-in Ethernet |
FX3U Series (High-Performance, Expandable)
| Modell | I/O Configuration | Ausgabetyp | Leistung | Kernfunktionen |
| FX3U-16MR/ES | 8IN/8OUT | Relais | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-16MT/ES | 8IN/8OUT | Transistor | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-32MR/ES | 16IN/16OUT | Relais | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-32MT/ES | 16IN/16OUT | Transistor | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-48MR/ES | 24IN/24OUT | Relais | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-48MT/ES | 24IN/24OUT | Transistor | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-64MR/ES | 32IN/32OUT | Relais | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-64MT/ES | 32IN/32OUT | Transistor | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-80MR/ES | 40IN/40OUT | Relais | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-80MT/ES | 40IN/40OUT | Transistor | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-128MR/ES | 64IN/64OUT | Relais | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
| FX3U-128MT/ES | 64IN/64OUT | Transistor | Wechselstrom | Expandable to 256 Punkte, Basic instruction 0.065μs/step |
FX3GC / FX3UC Series (Kompakt, Expandable)
| Modell | I/O Configuration | Ausgabetyp | Leistung | Kernfunktionen |
| FX3GC-32MR/ES | 16IN/16OUT | Relais | Wechselstrom | Kompakte Größe, expandable to 128 Punkte |
| FX3GC-32MT/ES | 16IN/16OUT | Transistor | Wechselstrom | Kompakte Größe, expandable to 128 Punkte |
| FX3UC-32MT-LT | 16IN/16OUT | Transistor | Gleichstrom | Ultra-thin design, expandable to 256 Punkte |
| FX3UC-64MT-LT | 32IN/32OUT | Transistor | Gleichstrom | Ultra-thin design, expandable to 256 Punkte |
- Classic Series (FX2N/FX1N/FX1S) – Discontinued but Widely Used
3.1 FX2N Series (High-Performance)
| Modell | I/O Configuration | Ausgabetyp | Leistung | Kernfunktionen |
| FX2N-16MR-001 | 8IN/8OUT | Relais | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-16MT-001 | 8IN/8OUT | Transistor | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-32MR-001 | 16IN/16OUT | Relais | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-32MT-001 | 16IN/16OUT | Transistor | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-48MR-001 | 24IN/24OUT | Relais | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-48MT-001 | 24IN/24OUT | Transistor | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-64MR-001 | 32IN/32OUT | Relais | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-64MT-001 | 32IN/32OUT | Transistor | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-80MR-001 | 40IN/40OUT | Relais | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-80MT-001 | 40IN/40OUT | Transistor | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-128MR-001 | 64IN/64OUT | Relais | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
| FX2N-128MT-001 | 64IN/64OUT | Transistor | Wechselstrom | Basic instruction 0.08渭s/step, expandable to 256 Punkte |
3.2 FX1N Series (Standard)
| Modell | I/O Configuration | Ausgabetyp | Leistung | Kernfunktionen |
| FX1N-14MR-001 | 8IN/6OUT | Relais | Wechselstrom | Expandable to 128 Punkte, built-in RS485 |
| FX1N-14MT-001 | 8IN/6OUT | Transistor | Wechselstrom | Expandable to 128 Punkte, built-in RS485 |
| FX1N-24MR-001 | 14IN/10OUT | Relais | Wechselstrom | Expandable to 128 Punkte, built-in RS485 |
| FX1N-24MT-001 | 14IN/10OUT | Transistor | Wechselstrom | Expandable to 128 Punkte, built-in RS485 |
| FX1N-40MR-001 | 24IN/16OUT | Relais | Wechselstrom | Expandable to 128 Punkte, built-in RS485 |
| FX1N-40MT-001 | 24IN/16OUT | Transistor | Wechselstrom | Expandable to 128 Punkte, built-in RS485 |
| FX1N-60MR-001 | 36IN/24OUT | Relais | Wechselstrom | Expandable to 128 Punkte, built-in RS485 |
| FX1N-60MT-001 | 36IN/24OUT | Transistor | Wechselstrom | Expandable to 128 Punkte, built-in RS485 |
3.3 FX1S Series (Micro Type)
| Modell | I/O Configuration | Ausgabetyp | Leistung | Kernfunktionen |
| FX1S-10MR-001 | 6IN/4OUT | Relais | Wechselstrom | Non-expandable, for small equipment |
| FX1S-10MT-001 | 6IN/4OUT | Transistor | Wechselstrom | Non-expandable, for small equipment |
| FX1S-14MR-001 | 8IN/6OUT | Relais | Wechselstrom | Non-expandable, for small equipment |
| FX1S-14MT-001 | 8IN/6OUT | Transistor | Wechselstrom | Non-expandable, for small equipment |
| FX1S-20MR-001 | 12IN/8OUT | Relais | Wechselstrom | Non-expandable, for small equipment |
| FX1S-20MT-001 | 12IN/8OUT | Transistor | Wechselstrom | Non-expandable, for small equipment |
| FX1S-30MR-001 | 16IN/14OUT | Relais | Wechselstrom | Non-expandable, for small equipment |
| FX1S-30MT-001 | 16IN/14OUT | Transistor | Wechselstrom | Non-expandable, for small equipment |
- Selection Quick Reference
| Serie | Performance Level | Max I/O Expansion | Integrierte Funktionen | Anwendungsszenario |
| FX5U | Highest | 512 Punkte | Ethernet+RS485+Analog I/O+4-axis positioning | Complex standalone control, high-speed motion control |
| FX5S | Hoch | Non-expandable | Analog I/O+2-axis positioning | Kleine Ausrüstung, no expansion required |
| FX5UC | Hoch | 512 Punkte | Ethernet+RS485+Analog I/O+4-axis positioning | Limited installation space, complex control |
| FX3U | Medium | 256 Punkte | High-speed operation, multi-axis positioning | Mature applications, cost-sensitive projects |
| FX3G | Mittel-Niedrig | 128 Punkte | Ethernet, basic positioning | Medium & small equipment, network demand |
| FX2N | Medium (Auslaufmodell) | 256 Punkte | High-speed operation | Old equipment maintenance, spare parts replacement |
| FX1N | Niedrig (Auslaufmodell) | 128 Punkte | Basic communication | Simple control, low cost demand |
| FX1S | Am niedrigsten (Auslaufmodell) | Non-expandable | No expansion capability | Micro equipment, minimal control |
- Key Remarks
- Software Compatibility
FX5 Series: GX Works3 V1.047Z or above required
FX3 Series: Supports GX Works2 and GX Developer
Classic Series: Only supports GX Developer
- Output Type Selection
Relaisausgang (R): Suitable for AC load & induktive Last; Contact life ~100,000 times
Transistor Output (T): Suitable for DC load & high-speed switching; Response time 0.1ms, lange lebensdauer
- Terminal Type Selection
Screw Terminal (ES/DS): Firm wiring for normal environment
Spring Terminal (ESS/DSS): Fast wiring for vibration environment
- Discontinued Notice
FX2N/FX1N/FX1S are discontinued; recommended replacement: FX5S / FX3G
FX3 Series still in mass production with stable cost-performance.
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien



















NH42-63-318x560.png)