OMRON G3PA-240B-VD Halbleiterrelais

The Omron G3PA series single-phase solid state relay (SSR) with integrated heat sink, zero-crossing turn-on, DIN-Schienenmontage, directly driven by PLC DC signals. Widely used for non-contact switching control of heating elements, fans and lamp loads. Wichtiger Hinweis: Dieses Modell wird nicht mehr hergestellt. Only stock units are available or alternative models should be selected. Modell ...

  • Produktdetails

Der Omron G3PA series single-phase solid state relay (SSR) with integrated heat sink, zero-crossing turn-on, DIN-Schienenmontage, directly driven by SPS DC signals. Widely used for non-contact switching control of heating elements, fans and lamp loads.

Wichtiger Hinweis: Dieses Modell wird nicht mehr hergestellt. Only stock units are available or alternative models should be selected.

  1. Modellcode-Definition

G3PA: Serienname, solid state relay with integrated heat sink

2: Einphasig, AC24~240V output specification

40: Rated load current 40A

B: Built-in heat sink

VD: DC5~24V DC input control, opto-triac isolation, zero-crossing turn-on

  1. Grundlegende elektrische Spezifikationen

✅ Input Side (Control Terminals +A1, -A2)

Steuerspannung: DC5~24V, operating range DC4~30V

Maximum input current: 7mA (directly drivable by PLC output point)

Operating voltage ≤DC4V; Reset voltage ≥DC1V

Isolierung: Opto-triac isolation

✅ Output Side (Load Terminals 1, 2)

Rated load voltage: AC24~240V, operating range AC19~264V (50/60Hz)

Rated load current: 40A @40℃; derate to 36A for dense side-by-side mounting

Surge withstand current: 440A (60Hz, 1 Zyklus)

Ich nicht: 1260 A²s

On-state voltage drop: ≤1.6V RMS

Switching characteristic: Zero-cross turn-on, reduces switching surge

Arbeiten / release time: Within half cycle of load power supply +1ms

✅ Environmental & Mechanisch

Betriebstemperatur: -30℃ ~ +80℃ (keine kondensation)

Montage: DIN-Schienen- oder Schraubmontage; screw type terminals

Abmessungen: W47 × H100 × D100 mm

Dielectric strength between input and output: AC4000V

  1. Typische Anwendungsszenarien

Temperaturkontrolle: Heating tubes, ceramic heaters, infrared heating (am häufigsten)

Beleuchtung: High power lamp banks, halogen lamps

Motoren: Small single-phase fans (widerständig / weakly inductive load preferred)

Notiz: Inductive loads and loads with large starting inrush current require additional varistor and RC snubber protection.

  1. Verkabelungsrichtlinien
  2. +A1, -A2: DC control signal, good polarity tolerance. It is recommended to connect PLC positive output to A1.
  3. Terminals 1, 2: Connected in series to AC load circuit, L/N non-polarity.
  4. RC-Dämpferschaltung + varistor connected in parallel at output terminals for inductive loads.
  5. Derate current and reserve heat dissipation clearance when multiple SSRs are installed side by side on DIN rail.
  6. Replacement Models for Discontinued Product
  7. Upward replacement within same series: G3PA-260B-VD (60A, DC5~24V input). Same pin layout with higher capacity.
  8. New generation alternative: G3PE series G3PE-245B, 45A DC control, DIN-Schienenmontage, Direkter Ersatz.
  9. Domestic compatible SSR: 40A solid state relay, DC5-24V input, AC240V, zero-cross type with integrated heat sink.
  10. Allgemeine Fehlerbehebung
  11. Input LED does not light: Check PLC output voltage and broken wiring; insufficient input current to drive SSR.
  12. LED lights but load does not turn on: Lose Ausgangsklemmen, broken load; internal triac damage.
  13. Load remains energized after control signal removed: SSR short-circuit failure (common for heating loads), usually caused by overheating or surge breakdown.
  14. Frequent false triggering: Control cable runs in parallel with power cable causing interference; connect 1000pF anti-interference capacitor at input side.
  15. Auswahlnotizen
  16. Widerstandslasten: Derate to 0.7 times rated current for selection.
  17. Heating loads have low cold resistance with large starting inrush current, Es ist eine ausreichende aktuelle Marge erforderlich.
  18. Further derate when ambient temperature >40℃ or densely mounted.
  19. Solid state relay has no mechanical contacts, cannot serve as safety disconnect switch. Circuit breaker must be fitted on main circuit.

OMRON G3PA-240B-VD (40A DC to AC Zero-cross SSR) Typische Anwendungsfälle

Product Recap: Integrated heat sink, DIN-Schienenmontage, DC5~24V input, AC24~240V 40A, zero-cross turn-on. Directly driven by PLC, mainly suitable for resistive loads. RC+MOV snubber required for inductive loads.

Fall 1: Temperature Control System – Industrial Heating Tube Control (Am beliebtesten)

Anwendung

Öfen, hot presses, plastic dryers, mold temperature machines, food baking lines, single-phase 220V heating tubes, max power ~8kW (220V×40A), PID power regulation by PLC + Temperaturregler.

Systemkonfiguration

  1. Kontrolle: Transistor output DC24V from temperature controller / PLC connected to A1/A2 of G3PA; zero-cross switching reduces grid harmonic distortion.
  2. Hauptstromkreis: AC220L → SSR terminal 1; Terminal 2 → heating tube → N.
  3. Schutz: 3P circuit breaker + fast fuse at upstream; thermocouple over-temperature protection is recommended for heating tubes.
  4. Snubber: RC optional for resistive loads; 470V varistor is recommended for high power applications to absorb grid surge.

Derating Recommendation

Continuous long-term operation: Load current controlled within 28A (0.7×rating); reduce to 24A for side-by-side multi-unit installation.

Vorteile

Contactless operation, no contact erosion even under frequent switching (several times per second), higher PID temperature control accuracy.

Häufiger Fallstrick

Heating tubes have large cold-state inrush current. Continuous full-current operation tends to break down SSR; do not treat rated 40A as continuous operating current.

Fall 2: High Power Halogen / Infrared Lamp Bank Control

Anwendung

UV curing lamps, infrared heating lamps, industrial inspection light sources, infrared radiation panels for drying lines, 220V AC lamp banks.

Systemkonfiguration

PLC DC24V output drives SSR; lamp load connected in parallel to SSR output terminals.

Halogen lamp has extremely low cold resistance, inrush current at switch-on can reach 8~10 times rated current.

Vorsichtsmaßnahmen

  1. Zero-cross G3PA is well suited for lamp loads, turn-on at voltage zero point to reduce inrush.
  2. Heavy derating is mandatory: lamp load at 0.4~0.5 times SSR rating; load ≤20A for this 40A SSR.
  3. NTC surge limiting thermistor in series is recommended.

Vorteile

Silent switching, no electric arc under frequent on/off, suitable for automated production line light sources.

Fall 3: Fans / Small Single-phase Motors (Induktive Last)

Anwendung

Air duct heating matched fans, cabinet high-power cooling fans, small conveying single-phase fans for continuous start-stop control.

This is inductive load, RC-Snubber + MOV varistor must be installed (100Ω/2W +0.1μF/400VAC +470V varistor).

System

PLC controls SSR to start/stop fan; circuit breaker fitted upstream of SSR.

Einschränkung

Not suitable for frequent forward/reverse rotation of motor; not applicable for high-power motors with huge starting surge.

Back EMF generated at motor power-off can easily damage SSR, RC snubber is essential.

Fall 4: Solenoid Valve Bank, AC Contactor Coil Drive (Small Inductive Load)

Anwendung

Verpackungsausrüstung, pneumatic production lines, multiple parallel AC220V solenoid coils controlled centrally by PLC.

Systemkonfiguration

SSR output drives multiple parallel AC220V solenoid coils; RC+MOV connected in parallel to SSR terminals.

Notizen

Solenoid coil is inductance, generates high voltage spike at turn-off; total load current cannot exceed 40A.

Minor chattering of solenoid after SSR turn-off may occur due to RC leakage current. Lösung: connect 10kΩ/5W bleeder resistor across load terminals.

Fall 5: 220V AC Motorized Rollers for Conveyor Lines / Small Conveying Equipment

Anwendung

Logistics sorting lines, Verpackungsförderlinien, start-stop control of single-phase 220V motorized rollers.

Wichtige Punkte

RC+MOV snubber mandatory for motor inductive load; not suitable for frequent jogging with heavy impact, applicable for long run operation with long interval start-stop.

Fall 6: Environmental Test Chamber Heating Circuit

Anwendung

Constant temperature & humidity chamber, aging test chamber, resistive heating circuit with continuous PID power regulation.

Systemkonfiguration

PID DC24V output from temperature controller drives G3PA; multi-section heating zone control with multiple G3PA mounted side by side on DIN rail.

Wichtige Anmerkungen

Derate current and reserve heat dissipation clearance for side-by-side installation; ambient temperature around SSR must not exceed 60℃.

Load Selection Summary Table

LasttypRecommended DeratingRC+MOVBemerkungen
Resistive heating tube0.7×ratingOptional (MOV recommended)Most compatible, weit verbreitet
Halogen / Infrared lamp0.4~0.5×ratingEmpfohlenExtreme cold inrush current
Single-phase fan, small motor (induktiv)0.6×ratingObligatorischHigh risk of back EMF breakdown at turn-off
AC220V solenoid coil0.6×ratingObligatorischLeakage current may cause minor false actuation

General Usage Prohibitions for G3PA-240B-VD

  1. ❌ Not for large air compressors, high-power single-phase motors (excessive starting surge)
  2. ❌ Cannot act as safety disconnect switch, independent circuit breaker required for main circuit
  3. ❌ Not suitable for high-frequency high-voltage inductive loads; triac short-circuit failure risk (SSR stuck ON, load continuously powered, risk of over-temperature fire in temperature control systems)
  4. ❌ Further current derating required when ambient temperature>60℃

G3PA-240B-VD Fault List by Application Scenario

Modell: Omron G3PA-240B-VD, 40A DC input zero-cross SSR; main failure modes: permanent short-circuit at output (most hazardous), failure to turn on, intermittent false triggering.

Precaution: If SSR fails shorted, load stays energized continuously. Over-temperature fire risk is high for heating systems. Independent over-temperature protection must be fitted on main circuit.

Fall 1: Heating Tube / Oven, Mold Temperature Machine (Widerstandslast, Am häufigsten)

Fault1: SSR short-circuits after operating for a period, heating never stops

Symptom: PLC control signal removed, no input at A1/A2, heating tube remains heated; SSR housing very hot.

Grundursache:

1) Long-time full current operation without 0.7 Derating; insufficient heat dissipation with side-by-side mounting.

2) Aging heating tube with partial short circuit, surge current breaks triac.

3) Grid voltage spike without varistor protection.

Abhilfe: Control load current ≤28A; install 470V varistor; periodically test insulation of heating tube; add independent over-temperature thermostat for hard cut-off.

Fault2: Large temperature fluctuation under PID control, intermittent heating

Symptom: Temperature controller output normal, heating cuts in and out randomly.

Grundursache:

1) Insufficient output current from PLC, voltage drop on cable.

2) Loose SSR terminals, contact resistance generates heat.

3) Oxidized wiring of heating tube, schlechter Kontakt.

Abhilfe: Klemmen festziehen (torque 0.8~1.0N·m); check driving capacity of PLC transistor output; replace aged heating tube.

Fault3: SSR indicator LED on, but no heating

Grundursache: Broken output circuit, burnt heating tube; open-circuit damage of internal triac.

Abhilfe: Measure resistance of heating tube after power-off; measure AC voltage across SSR output terminals.

Fall 2: Halogen / Infrared Lamp Bank

Fault1: SSR damaged immediately upon lamp switch-on

Symptom: SSR burns out right after lamp activation even if average current is low.

Grundursache: Extremely low cold resistance of halogen lamp, inrush current reaches 8~10 times rated; zero-cross turn-on still cannot eliminate huge surge without derating.

Abhilfe: Limit load current to 0.4~0.5×SSR rating; fit NTC surge suppression thermistor in lamp circuit; prefer lamp-specific SSR.

Fault2: Lamp flickering

Grundursache: Fluctuating supply voltage; lamp aging; internal component aging of SSR.

Abhilfe: Replace aged lamps; verify power supply stability.

Fall 3: Single-phase Fan, Small Motor (Induktive Last)

Fault1: SSR breaks down every time fan stops

Symptom: Fan runs normally, SSR fails when control signal turns off.

Grundursache: Inductance of motor winding generates high back EMF at power-off; RC+MOV not fitted.

Abhilfe: Install RC snubber (100Ω/2W +0.1μF/400VAC in series) +470V varistor, wire directly close to SSR terminals.

Fault2: Fan slowly rotates after SSR turned off

Symptom: Fan does not fully stop after PLC signal removed, low speed rotation.

Grundursache: Leakage current introduced by RC snubber, weak voltage induced on motor winding.

Abhilfe: Fit 10kΩ/5W bleeder resistor across motor terminals; or use mechanical contactor for complete cut-off.

Fall 4: AC220V Solenoid Coil Bank (Induktive Last)

Fault1: Solenoid randomly pulls in (Fehlauslösung)

Symptom: Solenoid occasionally chattering or actuating without PLC output signal.

Grundursache: RC leakage current; electromagnetic interference when control cable runs parallel with power cable; excessively long control wire.

Abhilfe: Fit 10kΩ/5W bleeder resistor across load terminals; separate routing for control and power cables; fit 1000pF anti-interference capacitor at input side.

Fault2: SSR damaged after multiple switching cycles

Grundursache: High voltage spike from coil turn-off without RC+MOV protection.

Abhilfe: Install RC+MOV; do not connect excessive solenoids in parallel, derate total current to 0.6×rating.

Fall 5: Conveyor Motorized Roller

Fault1: Unstable start-stop of roller, occasional start failure

Symptom: Roller sometimes fails to start even when control signal is sent to SSR.

Grundursache: Large motor starting surge; insufficient SSR margin; voltage drop on cable.

Abhilfe: Reduce load capacity; verify power cable gauge; RC+MOV mandatory for inductive load.

Fault2: Severe overheating of SSR

Grundursache: Long-time heavy current operation; poor heat dissipation for multiple SSR mounted side by side on DIN rail.

Abhilfe: Increase mounting gap between SSR units; reduce load current; add auxiliary cooling fan if necessary.

General Common Faults (Gilt für alle Szenarien)

  1. Input indicator LED at A1/A2 does not light

Fehlerbehebungssequenz:

1) Check PLC output, confirm DC24V present.

2) Broken control wire, umgekehrte Polarität (tolerated to some extent, long-term reverse polarity damages input LED).

3) Burnt input circuit of SSR.

  1. Input LED normal, no output action

Fehlerbehebung: Main power supply available; loose output terminals; open-circuit damage of internal triac.

  1. Random SSR failure under high ambient temperature

Grundursache: Ambient temperature>60℃, heat dissipation deteriorates, device characteristic drift.

Abhilfe: Verbessern Sie die Belüftung des Schranks; further derate current; mount SSR away from heat-generating components.

  1. Random SSR false actuation caused by interference

Symptom: SSR turns on/off irregularly during equipment operation.

Gegenmaßnahmen:

1) Separate cable trunking for control signal and power cable, avoid long parallel routing.

2) Fit isolation relay at PLC output side.

3) Connect 1000pF high voltage ceramic capacitor at input side.

Rapid Fault Diagnosis Procedure (For On-site Commissioning)

  1. Disconnect AC main power, keep DC24V control power on, check whether SSR input LED follows PLC signal.
  2. Ausschalten, measure resistance across SSR output terminals:

Normaler Zustand (no input signal): Hoher Widerstand, Mega-ohm level.

Resistance close to conducting state without input: SSR short-circuited, DO NOT energize!

  1. Power on with load, measure AC voltage across SSR output terminals:

With ON signal: Voltage drop across SSR ≤1.6V.

With OFF signal: Voltage across SSR close to AC220V.

  1. Check SSR housing temperature; improve derating or heat dissipation if temperature exceeds 70℃.

Sicherheitsregeln

  1. Short-circuit failure is the typical failure mode of this SSR. Independent mechanical over-temperature protection must be fitted for heating applications; do not rely only on PLC and SSR.
  2. Do not run long-term test without RC+MOV for any inductive load.
  3. SSR shall not be used as safety isolation switch; main circuit breaker must be opened for equipment maintenance.