Artikel-Nr.: 120329 | Produktstatus: Veraltet (Discontinued by Manufacturer)
- Aufschlüsselung des Modellcodes
`UC2000-F43-2KIR2-V17`
- UC2000: UC series ultrasonic sensor, maximum measuring distance 2000 mm
- F43: Flat rectangular housing (F-type enclosure)
- 2K: 2 relay contact outputs
- ICH: Analogue 4…20 mA current output
- R2: Built-in RS232 interface for parameter programming
- V17: Hardware version V17
- Grundlegende technische Spezifikationen
Ranging Performance
| Artikel | Spezifikation |
| Effective measuring range | 100 … 2000 mm |
| Blind zone (dead zone) | 0 … 100 mm |
| Transducer frequency | Ca. 175 kHz |
| Standard reflector target | 100×100 mm flat plate |
| Measurement resolution | 0.5 mm |
| Non-linearity error | <0.2% of full scale |
| Repeat accuracy | ≤0.1% of full scale |
| Programmable hysteresis | 0~15% of measuring range adjustable |
Elektrische Daten
Versorgungsspannung:
Without analogue output: 10…30 VDC; With 4–20mA activated: 15…30 VDC
No-load power consumption: ≤0.7 W; Max. full-load power consumption: ≤2 W
Output Combination (Key Feature)
✅ 2 independent relay outputs (SPDT changeover contacts)
Kontaktbewertung: 60 VDC / 1 A (ohmsche Last, max. 24 W DC)
✅ 1 analogue 4 … 20 mA-Ausgang, maximum load impedance ≤500 Ω
Kommunikation: RS232, 9600bps, 8N1. Parameter configuration via UC-PROG1-USB and ULTRA2001 software
Ansprechzeit: Min. ≤50 ms; Factory default ≤150 ms
Mechanisch & Umweltspezifikationen
Verbindung: M12×1 8-pin male connector
Schutzklasse: IP65
Gehäusematerial: PBT thermoplastic
Betriebstemperatur: -25 ℃ ~ +70 ℃
Lagertemperatur: -40 ℃ ~ +85 ℃
Gewicht: 290 G
Built-in temperature compensation
LED-Statusanzeige
Green LED steady ON: Target within measuring window; Green LED flashing: No target detected
Red LED ON: Fault condition (high acoustic interference, Verdrahtungsfehler, usw.)
- M12 8-Pin Pin Assignment
| Stift | Definition |
| 1 | DC+ Power Positive |
| 2 | Relais 1 Gemeinsames Terminal |
| 3 | Gleichstrom- Power Negative |
| 4 | Relais 2 Gemeinsames Terminal |
| 5 | 4~20mA Analogue Signal Output |
| 6 | Relais 1 Normalerweise geöffnet / Normalerweise geschlossen |
| 7 | Relais 2 Normalerweise geöffnet / Normalerweise geschlossen |
| 8 | Schild (Housing Earth) + RS232 Communication |
⚠️ Important Note: When using the 4–20mA output, supply voltage must not drop below 15 VDC; otherwise analogue output malfunction will occur.
- Typische Anwendungsfelder
- Warehouse & Logistik: Level height detection, pallet presence detection, anti-collision distance measurement
- Verpackungsmaschinen: Roll diameter measurement, material presence monitoring
- Wasseraufbereitung: Non-contact level measurement for open tanks
- Allgemeine Automatisierung: All-in-one solution for dual limit switching + continuous distance transmission
Vorteil: Single sensor delivers two limit switch signals + continuous distance feedback, spart Installationsraum.
- Ersatzoptionen (Critical Section)
No direct pin-to-pin upgraded model available with original F43 flat housing. Two selection options:
Option 1: Functional Equivalent (Requires modified mounting bracket & electrical adaptation)
UC2000-L2-IUR2-V15
Messbereich: 100…2000 mm
Ausgänge: 4–20mA analogue + 2 PNP switching outputs + RS232
Unterschied: Transistorausgang, no relay contacts; Cylindrical housing with different mounting dimensions
If passive relay contacts are mandatory on site, select third-party ultrasonic sensor paired with external relay.
Option 2: Maintain Relay Output
Only used / refurbished stock available for legacy series. For new projects:
UC2000-L2-IUR2-V15 + auxiliary miniature relay for contact conversion.
- Auswahl & Betriebsrichtlinien / Pitfall Avoidance
- Blind Zone Limitation: Reliable measurement impossible within 100 mm; Do not select for close-range applications.
- Acoustic Cone Interference: Activate sensor synchronisation function when multiple sensors are installed side-by-side to prevent mutual ultrasonic interference.
- Medium Limitation: Soft foam, fluffy fabrics produce weak echo and lead to unstable detection.
- Relay Service Life: Electrical service life limited to 3×10⁵ switching cycles. Not suitable for high-frequency switching applications. Transistor output models are recommended for frequent operation.
- Programming Requirement: Adjustment of switching points, measuring range and hysteresis requires UC-PROG1-USB programming cable. No external teach-in button available.
- Fehlerbehebungsmatrix
| Fehlersymptom | Grundursache | Abhilfemaßnahme |
| Analogue output locked at 4mA / 20mA | Target out of measuring range / Undersupply voltage | Verify supply ≥15 VDC; Confirm target is within 100~2000 mm range |
| Relay triggers falsely and frequently | Acoustic reflection interference, insufficient hysteresis setting | Increase hysteresis parameter; Install separation baffles; Enable synchronisation mode |
| Red LED continuously illuminated | Übermäßige Welligkeit der Stromversorgung / Internal sensor failure | Add power supply filter; Check shielding wiring of pin 8 |
| Communication connection failure | Incorrect RS232 wiring, mismatched baud rate | Confirm 9600,8N1 setting; Use original UC-PROG1 adapter |
Pepperl+Fuchs UC2000-F43-2KIR2-V17 Practical Application Cases
Core Feature Recap (All cases based on unique strengths of this model)
Flat F43 rectangular housing, measuring range 100~2000 mm;
2 SPDT passive relay contacts + 4…20mA analogue output + RS232 programmable interface;
Highlight: Single sensor integrates dual limit switching + continuous distance transmission. Passive relay contacts can directly drive contactors and audible/visual alarms. Flat housing fits confined mounting spaces; IP65 rated with built-in temperature compensation.
Wichtige Erinnerung: This sensor is discontinued by the manufacturer. Alternatives are recommended for new projects. The below cases are proven historical applications.
Cse 1 | Abwasserbehandlung: Level Monitoring & Pump Control for Open Settling Tank
Working Conditions
Open regulating tank in small wastewater treatment plant with surface foam and high humidity. Anforderungen:
① Continuous level signal transmitted to PLC via 4–20mA;
② Low-level pump start, high-level pump stop (two relays directly control contactors to reduce PLC point consumption);
③ Limited installation space above tank guardrail, cylindrical sensors cannot be fitted.
Implementation Scheme
Sensor installed horizontally with downward tilt above the tank, avoiding severe foam zones.
Relais 1: High level limit (1.6 M) → Trigger to stop drainage pump
Relais 2: Low level limit (0.4 M) → Trigger to activate water inlet
4–20mA signal sent to central control for real-time liquid level display
RS232 used on-site to calibrate measuring range and hysteresis, suppressing frequent fluctuation caused by water ripples.
Reason for Model Selection
Flat F43 housing compatible with narrow mounting brackets; Passive relays drive contactors directly without additional auxiliary relays. Ultrasonic measurement immune to water colour and mild foam.
Risk Notes
Thick foam absorbs ultrasound; proper mounting tilt required. Blind zone of 100 mm prevents low-level alarm setup near tank bottom.
Fall 2 | Plastic Extrusion Industry: Residual Roll Diameter Monitoring for Film / Nonwoven Web
Working Conditions
Continuous unwinding of raw material rolls on cast film production line. Control system requirements:
- Real-time roll outer diameter measured; 4–20mA signal sent to tension controller for automatic unwinding torque regulation;
- Dual limit: Low material pre-warning + complete roll depletion safety shutdown.
Implementation Scheme
Sensor mounted laterally on machine frame, aligned horizontally with roll outer surface; 0.1~2m measuring range matches maximum roll diameter.
Relais 1: Minimum roll diameter reached (pre-warning) → Audible & visual alarm for material preparation
Relais 2: Roll diameter hits minimum limit → Full production line safety shutdown
Continuous 4–20mA analogue distance output for roll diameter conversion and closed-loop tension control.
Selection Advantage Comparison
Conventional transistor-output sensors rely on PLC logic for dual alarm functions. Built-in relays enable direct wiring to alarm circuits for legacy retrofit projects without modifying PLC programs.
Operation Tip
Surface wrinkles and web vibration cause signal fluctuation; configure sufficient measurement hysteresis via software.
Fall 3 | Logistics Conveyor Line: Pallet Height Detection & Dual Position Limit
Working Conditions
Roller conveyor for automated warehouse transporting wooden / plastic pallets. Photoelectric sensors prone to false triggering caused by dust and pallet gaps. Anforderungen:
① Confirm pallet arrival (near-point switch);
② Overheight pallet detection to prevent jamming in vertical lift;
③ Real-time pallet height data uploaded to WMS for cargo dimension verification.
Implementation Scheme
Sensor side-mounted above conveyor channel:
Relais 1: Pallet arrival confirmation signal
Relais 2: Pallet overheight alarm, trigger conveyor emergency stop
4–20mA output of measured pallet height sent to upper system for cargo dimension validation.
Core Value
Slim flat housing embedded into narrow side space of conveyor. Ultrasonic detection unaffected by pallet holes and dust; passive relay contacts compatible with legacy safety circuits.
Fall 4 | Chemical Raw Material Hopper: Granular Level Monitoring (Plastic Pellets, Calcium Carbonate)
Working Conditions
Open-top raw material hopper for small extruders. Heavy dust environment unsuitable for capacitive level switches. Anforderungen:
Low-level pre-warning, high-level full hopper shutdown, plus continuous level monitoring.
Implementation Scheme
UC2000-F43 installed laterally at hopper top:
Relais 1: High material level → Stop feeding conveyor motor
Relais 2: Low material level → Start raw material feeding conveyor
4–20mA signal transmitted to central control for daily raw material consumption tracking.
Vorsichtsmaßnahmen
Severe dust clouds attenuate ultrasonic echo; avoid vertical installation facing falling material stream.
Fall 5 | Baumaschinen / AGV: Anti-collision Distance Warning System
Working Conditions
Indoor factory Automated Guided Vehicle (AGV). Dual-stage collision protection required:
- Long-distance pre-warning (speed reduction); 2. Short-distance emergency stop; Continuous distance signal sent to on-board controller.
Implementation Scheme
Flat-mounted F43 sensor on AGV outer body (cylindrical sensors protrude and risk collision damage). Measuring range 100~2000 mm:
Relais 1: 1.2 m detection distance → Vehicle speed reduction
Relais 2: 0.5 m danger distance → Emergency stop
4–20mA real-time distance signal for obstacle distance display on vehicle HMI.
Vorteil
Flat housing resists scratches from cargo. Independent safety relay circuit enables emergency stop even if main controller fails.
Fall 6 | Verpackungsmaschinen: Stacked Carton Height Monitoring
Working Conditions
Palletising station for carton stacking. Verify stack height compliance and implement overheight protection.
Relais 1: Stack height reaches target → Robot executes transfer operation
Relais 2: Overheight stack → Equipment lock and alarm
Continuous 4–20mA height data for production data acquisition.
Suitable for rigid flat-surface targets such as cartons and turnover boxes.
Zusammenfassung: Ideal Application Characteristics for This Model (Selection Checklist)
✅ Preferred Application Scenarios
- Confined installation space requiring flat rectangular housing; cylindrical ultrasonic sensors cannot be fitted
- Retrofit projects with existing control cabinets using passive contact signals; no intention to expand PLC I/O points
- Processes requiring dual limit switches + continuous analogue transmission integrated within one sensor
- Direct drive of 220 VAC audible/visual alarms or contactors (passive relay contacts)
- Environment with wide temperature fluctuation, Staub und Feuchtigkeit (built-in temperature compensation, IP65)
❌ Unsuitable Scenarios
- Applications with millions of frequent switching cycles (limited mechanical relay life; transistor-output sensors preferred)
- Targets made of thick / soft foam (ultrasound absorption leads to poor detection)
- Measurement distance below 100 mm (inherent blind zone)
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien


















NH42-63-318x560.png)