Panasonic AKT4R111100 Temperaturregler - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Panasonic AKT4R111100 Temperaturregler - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

SPS/

Panasonic AKT4R111100 Temperaturregler

Status: Auslaufmodell (Last Order Date: 29 September 2023). No direct replacement officially recommended by Panasonic Type: 48×48mm panel-mounted PID temperature controller ✅ Model Code Breakdown (AKT4R 1 1 1 1 00) AKT4R: KT4R series, 48×48 size 1st digit: Stromversorgung 1 = AC100–240V 2nd digit: Eingang 1 = Multi-input (TC / FTE / Gleichspannung ...

  • Produktdetails

Status: Auslaufmodell (Last Order Date: 29 September 2023). No direct replacement officially recommended by Panasonic

Typ: 48×48mm panel-mounted PID Temperaturregler

✅ Aufschlüsselung des Modellcodes (AKT4R 1 1 1 1 00)

  1. AKT4R: KT4R series, 48×48 size
  2. 11. Ziffer: Stromversorgung 1 = AC100–240V
  3. 2nd. Ziffer: Eingang 1 = Multi-input (TC / FTE / Gleichspannung / DC current)
  4. 3dritte Ziffer: Main control output 1 = Relay contact output
  5. 4Ziffer: Alarmausgang 1 = 1-point relay alarm
  6. 5th–6th digits: 00 = No RS485 communication, no heating/cooling control, no heater burnout alarm

📋 Wichtige Spezifikationen

Gesamtdimension: 48 × 48 × 58.8 mm, Panelmontage

Stromversorgung: Wechselstrom 100–240 V (50/60Hz), Stromverbrauch ca. 8VA

Input types (multi-input):

Thermoelement: K, J, R, S, B, E, T, N, PL-II, W

FTE (Resistance Temperature Detector)

Gleichspannung / DC current analog signal

Control output: Relaiskontaktausgang

Alarm: 1-point relay alarm output

Functional limitations: No heating/cooling dual control, no heater burnout alarm, no communication port

Steuermodus: PID

Genauigkeit: ±0.2% FS of full range

Umgebungsbedingungen: 0~50℃, 35~85 % relative Luftfeuchtigkeit (nicht kondensierend)

Gewicht: Ca. 120G

Frontplatte: With sealing gasket, Schutzart IP66 (panel side)

⚠️ Bewerbung & Ersatzhinweise

Typische Anwendungen: Öfen, heating molds, small heat treatment equipment, packaging machinery single-path constant temperature control

No official direct replacement; compatible engineering alternatives:

New Panasonic KT4 series (AKT4□ series; check terminals, logic and panel cutout size)

OMRON E5CC / E5CB, Fuji PXR4, RKC RH400 (all 48×48 relay output temperature controllers)

Replacement verification points: Eingabetyp, relay capacity, alarm logic, PID parameter settings, panel cutout dimension

📌 Same Series Reference Models

AKT4R111100: Keine Kommunikation

AKT4R1111001: Gleiche Spezifikationen + RS485 communication port

(Equivalent to AKT4R111100: 48×48, AC100–240V, multi-input, relay main output, 1-point alarm, keine Kommunikation, no heating/cooling function)

Wichtig: No pin-to-pin direct plug-and-play replacement. Terminal definitions differ on all alternatives; re-wiring and PID reconfiguration are mandatory.

  1. Japanese Imported Models (Ersatz der Originalausrüstung, Hohe Stabilität, Preferred for Foreign Trade)
  2. OMRON E5CC-RX2ASM-800

Spezifikationen: 48×48, AC100–240V, multi-input, OUT1 relay output, 1-Kanalalarm, PID auto-tuning

Unterschied: Different terminal layout and alarm menu; identical panel cutout for direct panel installation

Best for packaging machines, Öfen, mold temperature control; most widely used for overseas equipment repairs

  1. RKC RH400 (RH400 FK02-MAN)

Spezifikationen: 48×48, multi-input, Relaisausgang, single alarm, AC100–240V

Besonderheit: PID algorithm closest to Panasonic KT4R; easy for technicians familiar with older Panasonic controllers

  1. Fuji PXR4TCY1-8V000

Spezifikationen: 48×48, Relaisausgang, multi-input, single alarm

Vorteil: Mid-range price between OMRON and RKC; large stock availability for spare parts

  1. Autonics TK4S-24RN (Korean brand)

Spezifikationen: 48×48, AC100–240V, Relaisausgang, multi-input, 1 Alarm

Hohes Preis-Leistungs-Verhältnis; popular for Southeast Asia & Central Asia projects

  1. Delta DTA4848R0

Spezifikationen: 48×48, Relaisausgang, multi-input, single alarm

Taiwanese brand, stabile Versorgung, lower cost than Japanese models

  1. High-compatibility Chinese Models (Kostenpriorität, Domestic Retrofit & Low-budget Modification)
  2. Yudian AI-208D2G (48×48, Relaisausgang)

Multi-input, PID auto-tuning, single alarm; widely used domestically with abundant spare parts

  1. TQDEC CD101 FK02-MVAN

48×48, Relaisausgang, multi-input; same cutout for direct panel replacement

  1. REX-C100 (Multi-input version only)

Notiz: Many low-cost REX-C100 only support K-type thermocouple; strictly select the universal multi-input version

III. Panasonic Brand Upgrade Options (Same Manufacturer; Requires Wiring & Program Evaluation)

New Panasonic KT4 series (AKT4□ such as AKT4111100)

Notiz: Same 48×48 cutout, but terminal definitions and menu structure have been revised. Not pin-to-pin direct replacement; only for customers who insist on keeping Panasonic brand.

✅ Checkliste zur Überprüfung vor dem Austausch

Schalttafelausschnitt: 45×45mm (1/16 AUS; all above models meet this requirement)

Stromversorgung: AC100–240V (do not select 24V DC/AC versions)

Eingang: Universal multi-input (TC + PT100 + analoges Signal); avoid single K-type input only

Main control output: Relais (not SSR voltage or 4–20mA current output)

Alarm: Minimum 1 relay alarm output (AKT4R111100 only has 1 alarm point)

Kommunikation: Original unit has no RS485. You can choose non-comm versions or communication-ready units for future upgrades

Beschränkung: AKT4R111100 has no heating/cooling dual output and no heater burnout (HBA) Erkennung. Do not select high-end models with extra HBA or dual heating/cooling functions to avoid over-specification.

⚠️ Critical Reminder

No model offers pin-to-pin plug-and-play replacement. All alternatives have different terminal assignments. You must rewire the controller and reconfigure sensor type, PID-Parameter, alarm mode and alarm thresholds.

For bulk export equipment (bestcontactor foreign trade business), top recommended models: E5CC-RX2ASM-800, RH400, TK4S-24RN.

Quick Selection Guide by Application Scenario

Overseas/EU clients, quality first: E5CC-RX2ASM-800

Old equipment maintenance, matching Panasonic PID response: RKC RH400

Central Asia/Southeast Asia projects, balanced budget: Autonics TK4S-24RN

Domestic retrofit, knappes Budget: Yudian AI-208D2G

Full Panasonic KT Series Temperature Controller List (AKT Prefix, Industrial PID, Foreign Trade Spare Parts Version)

Notiz: KT4R (AKT4R) wird eingestellt; KT4B / KT4H / KT7 / KT8 / KT9 / KT2 are the current production sub-series. Unified model coding rule:

AKTxx + Leistung + Eingang + Hauptausgang + Alarm + Heating/Cooling + Heater Burnout + Kommunikation (Suffix 1 = RS485)

Code Definition:

Leistung: 1=AC100–240V|2=AC/DC24V

Eingang: 1=Multi-input (TC/RTD/DC voltage/current)

Hauptausgang: 1=Relay|2=SSR voltage drive|3=4–20mA current

Alarm: 1=1-point alarm|2=2-point alarm

Heating/Cooling & Heater Burnout: 0=None

Suffix: No suffix = No communication; 001 = RS485 communication

  1. KT4R Series (48×48, slim body, DISCONTINUED | Your target series)

Dimension: 48×48×58.8mm

AKT4R111100 ✅ Your model: AC100–240V, multi-input, Relaisausgang, 1 Alarm, no heating/cooling, no HBA, keine Kommunikation

AKT4R1111001: Gleiche Spezifikationen + RS485-Kommunikation

AKT4R112100: SSR voltage output, 1 Alarm, keine Kommunikation

AKT4R1121001: SSR output, 1 Alarm, RS485

AKT4R112200: SSR output, 2-point alarm, keine Kommunikation

AKT4R113100: 4–20mA current output, 1 Alarm

AKT4R113200: 4–20mA current output, 2 Alarm

AKT4R211100: AC/DC24V power supply, Relais, 1 Alarm

  1. KT4B / KT4H Series (48×48, thick body, upgraded replacement for KT4R)

Dimension: 48×48×95mm

AKT4B111100: Relaisausgang, 1 Alarm, keine Kommunikation

AKT4B1111001: Relaisausgang, 1 Alarm, RS485

AKT4B111200: Relaisausgang, 2 Alarm

AKT4B1112001: Relaisausgang, 2 Alarm, RS485

AKT4B112100: SSR voltage output, 1 Alarm

AKT4B1121001: SSR voltage output, 1 Alarm, RS485

AKT4B112200: SSR voltage output, 2 Alarm

AKT4B1122001: SSR voltage output, 2 Alarm, RS485

AKT4B113100: Aktueller Ausgang, 1 Alarm

AKT4B1131001: Aktueller Ausgang, 1 Alarm, RS485

AKT4B113200: Aktueller Ausgang, 2 Alarm

AKT4B211100: AC/DC24V, Relais, 1 Alarm

AKT4H111105, AKT4H1122041 etc. (models with HBA heater burnout detection)

  1. KT8R Series (48×96, vertical type)

Dimension: 48×96×58.8mm

AKT8R111100: Relaisausgang, 1 Alarm, keine Kommunikation

AKT8R1111001: Relaisausgang, 1 Alarm, RS485

AKT8R111200: Relaisausgang, 2 Alarm

AKT8R112100: SSR output, 1 Alarm

AKT8R112200: SSR output, 2 Alarm

AKT8R113100: Aktueller Ausgang, 1 Alarm

  1. KT9R Series (96×96, large square panel)

Dimension: 96×96×58.8mm

AKT9R111100: Relaisausgang, 1 Alarm, keine Kommunikation

AKT9R1111001: Relaisausgang, 1 Alarm, RS485

AKT9R111200: Relaisausgang, 2 Alarm

AKT9R112100: SSR output, 1 Alarm

AKT9R112200: SSR output, 2 Alarm

AKT9R113100: Aktueller Ausgang, 1 Alarm

  1. KT7 Series (22.5mm ultra-narrow DIN rail panel type)

Dimension: 22.5×75×100mm

AKT711100: AC100–240V, Relais, 1 Alarm

AKT711200: AC100–240V, SSR voltage output

AKT711300: AC100–240V, current output

AKT721100: AC/DC24V, Relaisausgang

Besonderheit: Supports HBA heater burnout detection with optional CT current transformer

  1. KT2 Series (48×24, ultra-flat horizontal type)

Dimension: 48×24×98.5mm

AKT211100: AC100–240V, Relaisausgang

AKT211200: AC100–240V, SSR output

AKT211300: AC100–240V, current output

AKT221100: AC/DC24V, Relaisausgang

AKT2111001: RS485 communication version

  1. Passendes Zubehör (Commonly sold together for foreign trade spare parts)

AKT4H801: Terminal cover for KT4R

AKT8R801: Terminal cover for KT8R

AKT9R801: Terminal cover for KT9R

AKW4822: 48×48 mounting frame

AKW8822: 48×96 mounting frame

AKT4810: Shunt resistor (for DC current input)

AKT4H820: Programming cable for KT4H

CT1 / CT2: Current transformers for HBA heater burnout monitoring

  1. Series Lifecycle Summary (Key for spare parts business)
  2. KT4R (AKT4Rxxxxxx): Auslaufmodell. Last order date: 29 September 2023. Only surplus new stock & Gebrauchtgeräte, die auf dem Markt erhältlich sind.
  3. KT4B/KT4H: Same cutout upgrade model for KT4R; terminal pinout differs, not pin-to-pin direct replacement
  4. KT2 / KT7 / KT8R / KT9R: Main active production series
  5. Quick Cutout Reference

KT4R / KT4B / KT4H: 48×48 (1/16 AUS)

KT8R: 48×96 (1/8 DIN vertical)

KT9R: 96×96 (1/4 AUS)

KT2: 48×24

KT7: 22.5mm schmale Breite

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen