Phoenix Contact 2940391 Elektromagnetisches Relaismodul - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Phoenix Contact 2940391 Elektromagnetisches Relaismodul - Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter

SPS/

Phoenix Contact 2940391 Elektromagnetisches Relaismodul

Vollständiges Modell: EMG 17-REL/KSR-24/21-21-LC ✅ Basic Information Part No.: 2940391 Produkttyp: DIN-rail mounted electromagnetic relay module (built-in miniature relay soldered, relay core non-removable) Serie: EMG 17-REL Origin: Germany HS Code: 85364190 Verbindung: Screw terminal M3 Dimensions: 17.5(W) ×75(H) ×62.5(D) mm Packaging: 10 pcs per box, minimum order 1 pc ⚙️ Core Electrical Parameters Coil ...

  • Produktdetails

Vollständiges Modell: EMG 17-REL/KSR-24/21-21-LC

✅ Basic Information

Teile-Nr.: 2940391

Produkttyp: DIN-rail mounted electromagnetic relay module (built-in miniature relay soldered, relay core non-removable)

Serie: EMG 17-REL

Herkunft: Deutschland

HS-Code: 85364190

Verbindung: Screw terminal M3

Abmessungen: 17.5(W) ×75(H) ×62.5(D) mm

Verpackung: 10 pcs per box, minimum order 1 Stk

⚙️ Core Electrical Parameters

Coil Supply: 24V AC/DC universal, typical current 18mA, power consumption 0.43W

Kontaktkonfiguration: 2 changeover contacts DPDT (2C)

Kontaktmaterial: AgNi silver nickel, suitable for medium-load applications

Rated Continuous Current: 5A; maximum inrush switching current 6A

Maximale Schaltspannung: 250V AC/DC

Mechanisches Leben: ca. 5×10⁷ Operationen

Betriebstemperatur: -20℃ ~ +40℃; Lagertemperatur: -20℃ ~ +70℃

Isolierung: Basic isolation between input and output, with status LED and surge suppression circuit

Wiring Cross-section: 0.2–4mm² solid wire / 0.2–2.5mm² flexible wire

📌 Terminal Definition

A1/A2: Spulenstromversorgung (24V AC/DC)

11, 12, 14: 1st Wechslerkontakt

21, 22, 24: 2und Wechslerkontakt

📋 Anwendungsszenarien

PLC/controller signal isolation, low-side control of high-power loads, Magnetventile, contactors and indicator light circuits.

Besonderheit: Integrated soldered construction, relay core cannot be replaced separately; interchangeable pluggable models belong to the RIF series.

🔁 Alternative Reference (Compatible Equivalents)

Gleiche Markenalternative: RIF-1-RSC-24DC/2X21 (pluggable relay core, einfachere Wartung, same width 17.5mm)

Inländische Alternative: 17.5mm width relay module, 24V AC/DC, 2 Wechslerkontakte, Typ mit Schraubklemmen

📎 Zertifizierungen

cULus, EAC, CE; konform mit EN 61810-1, EN50178

Full List of Phoenix Contact EMG-REL Relay Modules

Notiz: EMG-REL includes 3 sub-width series: EMG10-REL (10mm), EMG17-REL (17.5mm, Mainstream), EMG22-REL (22.5mm). All adopt soldered built-in relays (non-removable relay core), screw terminals and DIN rail mounting.

KSR = standard monostable electromagnetic relay; SG = latching relay; G = DC-only coil; W = AC-only coil; LC = LED indicator + surge suppression circuit

  1. EMG 17-REL / 17.5mm (Am häufigsten, einschließlich 2940391)
Teile-Nr.Vollständiges ModellSpulenspannungContact SpecBemerkungen
2940391EMG 17‑REL/KSR‑24/21‑21‑LC24V AC/DC2 changeover (2C)✅ Item you enquired, AgNi, mit LED & suppression circuit
2940430EMG 17‑REL/KSR‑W230/21‑21‑LC230V und2 changeover (2C)AC-only version, dual contacts
2953854EMG 17‑REL/KSR‑24/2124V AC/DC1 changeover (1C)Single changeover, simplified version without LC
2947420EMG 17‑REL/KSR‑12/2112V AC/DC1 changeover (1C)12V universal model
2947653EMG 17‑REL/KSR‑230/21230V AC/DC1 changeover (1C)230V universal, dual A2 terminal
2946353EMG 17‑REL/KSR‑230/21/SO54230V AC/DC1 changeover (1C)SO54 special contact configuration, reinforced insulation
2949994EMG 17‑REL/KSR‑G24/SO38 BK24In DC1 normalerweise offen (NEIN)Schwarzes Gehäuse, AgSnO₂, 80A inrush withstand, dedicated for lamp loads
2946654EMG 17‑REL/SG‑B48/21/P48In DC1 changeover (1C)SG latching relay, with forward diode circuit
  1. EMG 10-REL / 10mm Narrow Version (Cabinet Space Saving)
Teile-Nr.Vollständiges ModellSpulenspannungContact SpecBemerkungen
2942108EMG 10‑REL/KSR‑G24/1‑LC24In DC1 normalerweise offen (NEIN)Mit LED, AgNi for standard loads
2941400EMG 10‑REL/KSR‑G60/1‑LC AU60In DC1 normalerweise offen (NEIN)AU gold-plated contacts, for low-current weak signals
  1. EMG 22-REL / 22.5mm Wide Version (High Isolation / Built-in Transistor Drive)
Teile-Nr.Vollständiges ModellSpulenspannungContact SpecBemerkungen
2951885EMG 22‑REL/KSR‑24/2124V AC/DC1 changeover (1C)High isolation, 5kV dielectric strength, allgemeiner Zweck
2952350EMG 22‑REL/KSR‑G24/TRN3524In DC1 changeover (1C)Built-in NPN transistor, direct drive by low-current PLC outputs, hybrid relay
  1. Suffix Explanation for Model Selection

KSR: Standard monostable electromagnetic relay

SG: Latching relay (remains state after power loss)

G: DC-only coil

W: Spule nur für Wechselstrom

LC: Integrated LED status indicator + coil surge suppression circuit (Freilaufdiode / Varistor)

/21: 1 Wechslerkontakt (1C: 11/12/14)

/21-21: 2 Wechslerkontakte (2C: 11-12-14 & 21-22-24)

SO38 / SO54: Special contact material (AgSnO₂, suitable for lamp loads and high inrush current)

AU: Gold-plated contacts, weak signal and low-level circuits

TRN35: Built-in NPN pre-drive transistor

  1. Schlüsselunterscheidung (Avoid Confusion with RIF Series)

EMG-REL: Relay soldered to base, non-replaceable relay core, cost-effective for fixed installation

RIF-REL / RIF-1: Plug-in replaceable relay core, separate base and relay, einfachere Wartung, same width for replacement

Application Fields of Phoenix Contact EMG-REL Relay Modules

Positionierung: Isolation relay for PLC / controller digital interfaces. Soldered integrated DIN-rail modules. Kernfunktionen: low-voltage signal isolation, signal amplification, level conversion, driving contactors, valves and indicator loads. Special variants (AU gold-plated, SO38 high-inrush, SG latching, TRN built-in transistor) for differentiated working conditions.

  1. Allgemeine industrielle Automatisierung (Am häufigsten, einschließlich 2940391)

Werkzeugmaschinen, Verpackungsausrüstung, Förderstrecken, Spritzgießmaschinen, woodworking machinery and custom automation control cabinets

Isolation for PLC DO channels: PLC 24V DC outputs driving contactors, Magnetventile, indicator lights and sound-light alarms

Türverriegelung, Statusrückmeldung, fault alarm circuits, auxiliary start-stop control

Vorteil: LC versions with LED and suppression circuit suppress reverse EMF and protect PLC modules

  1. Gebäudeautomation / HVAC

Air handling units, fresh air systems, Gebläsekonvektoren, air dampers and water valve actuator control

Beleuchtungskreise, Abluftventilatoren, Wasserpumpen, BA system signal interfaces

230V AC coil variants directly work with mains circuits; narrow EMG10-REL saves cabinet space

  1. Wasseraufbereitung & Kommunale Wasserversorgung / Drainage

Clean water tanks, sewage pump stations, chemische Dosiersysteme, bar screens, valve actuation and liquid level alarm signal isolation

Stable screw wiring suitable for long continuous operation in humid cabinet environments

  1. Erneuerbare Energie (PV, Energiespeicher, Windkraft)

Inverter cabinets, combiner boxes, auxiliary control for box-type transformers, fault alarm and status dry contact upload

Signal isolation to prevent strong electrical interference to acquisition boards; for onshore power stations (No ATEX certification, RIF explosion-proof series for hazardous areas)

  1. Logistiksortierung & Lagerautomatisierung

Sorters, Rollenbahnen, Stapler, AGV control cabinets, high-frequency switching signals, brake control and solenoid valves for sorting chutes

Hohe mechanische Lebensdauer (up to 5×10⁷ operations) for frequent switching cycles

  1. Infrastruktur: Tunnel & Road Lighting, Pumpstationen

Lichtsteuerung (SO38 models with AgSnO₂ contacts withstand high inrush current from incandescent and LED lamps, up to 80A inrush)

Remote start-stop control of fans and drainage pumps

  1. Testausrüstung, Instrumentierung & Medizinische Ausrüstung

AU gold-plated variants: Low contact resistance for mA-level weak signal switching, sensor signal switching and test fixtures; not suitable for high-power loads, gold layer may be damaged by arcing

  1. Andere Anwendungen

Control cabinet signal transfer, relay logic expansion, remote IO isolation, auxiliary dry contacts for fire alarm linkage

SG latching variants: retain switching state after power loss for state memory applications

✅ Selection Guide by Suffix

KSR standard type: General solenoid valves, Schütze, Kontrollleuchten (90% common applications, z.B. 2940391)

SO38 BK: Lamp loads, capacitive loads, hoher Einschaltstrom

AU gold-plated: Weak signal, instrument and low-current test circuits

SG latching: State retention after power failure

TRN35 built-in transistor: Direct drive by low-current PLC outputs without external pre-resistor

⚠️ Not Suitable Applications

EMG-REL complies with Class A EMC standards, not designed for consumer electronics. It does not have forcibly guided contacts, cannot be used for PLd / PLe safety circuits (safety relays with forcibly guided contacts required). No ATEX certification, not permitted in explosive hazardous areas.

Working Principle of Phoenix Contact EMG-REL Relay Modules

EMG-REL is an integrated electromagnetic relay module. Base, elektromagnetisches relais, LED indicator and suppression components are assembled in one DIN-rail housing. The relay core is permanently soldered and non-pluggable. Fundamentally, it is an electromechanical contact relay for low-voltage control of high-voltage circuits, electrical isolation and signal conversion.

  1. Basic Electromagnetic Principle
  2. Coil Side (Control Terminals A1/A2)

When rated coil voltage (DC24V / AC24V / AC230V etc.) is applied to A1 and A2, excitation current flows through the coil and generates magnetic flux on the iron core. The magnetic force overcomes spring tension and pulls the armature.

Coil energized → Armature pulls in → Contacts switch

Coil de-energized → Magnetic field disappears → Spring resets → Contacts return to original position

AC/DC universal coil versions (wie zum Beispiel 2940391) have coil windings designed for both AC and DC supply. Pure DC (Suffix G) and pure AC (suffix W) variants use different winding parameters.

  1. Contact Side (Load Terminals 11/12/14, 21/22/24)

Changeover contacts (1C / 2C) include normally closed (NC) und normalerweise offen (NEIN):

Spannungsloser Zustand: Gemeinsames Terminal (11) connects to NC (12) and disconnects from NO (14)

Spule unter Spannung: Gemeinsames Terminal (11) disconnects from NC (12) and connects to NO (14) to activate the external load (Magnetventile, Schützspulen, indicator lights etc.)

  1. Principle of Built-in Auxiliary Components (LC suffix, 2940391 is LC version)

LC = LED indicator + coil surge suppression circuit

LED-Statusanzeige: Wired parallel to the coil. Lights up when coil is powered to visually indicate drive signal presence. Integrated current-limiting resistor matched to rated voltage.

Surge suppression circuit (Freilaufdiode / Varistor):

Relay coils are inductive loads and produce high reverse EMF upon de-energization, which may damage PLC output chips.

Gleichstromspulen: Usually use freewheeling diodes to dissipate inductive energy

AC coils: Use varistor or RC snubber circuits to suppress AC voltage spikes

Models without LC suffix have no indicator or suppression; external surge protection must be added.

  1. Differentiated Principle of Special Sub-models
  2. SG Latching Version (EMG…SG)

Not conventional monostable relays. Permanent magnet inside:

Forward pulse power → Contacts close and stay latched after power removal

Reverse pulse power → Contacts reset and stay open after power removal

No continuous power required to maintain state, only pulse signal for switching, geringer Stromverbrauch.

  1. TRN35 Built-in Transistor Version (EMG…TRN35)

NPN pre-drive transistor integrated before coil: Low-current PLC signal drives the transistor first, then the transistor energizes the relay coil. Suitable for PLC channels with weak drive capacity.

  1. AU Gold-plated Contact Version

Gold plating on contact surface reduces contact resistance for mA-level weak signal switching. Not for heavy loads; gold plating is vulnerable to arc damage under high current.

  1. SO38 (AgSnO₂ Contacts)

Tin oxide silver contact material, arc-resistant and withstands high inrush surges, dedicated for lamp and capacitive loads to prevent contact welding.

  1. Electrical Isolation Logic

Basic insulation separates the coil control circuit and load contact circuit. It isolates PLC low-voltage side from high-voltage load side, blocks common-mode interference and prevents load-side faults from propagating into controller IO boards.

⚠️ Wichtig: This is only functional isolation. It is not a safety relay with forcibly guided contacts and cannot be used for PLe / PLd safety circuits.

  1. Simplified Working Flow (2940391, EMG17-REL/KSR-24/21-21-LC)

PLC digital output → 24V AC/DC supplied to A1/A2 → LED on, coil energized → Magnetic field pulls armature → Two changeover contacts switch synchronously → Solenoid valve / contactor energized

PLC output off → Coil de-energized → Suppression circuit dissipates residual coil energy → Spring resets contacts → Load de-energized

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen