Vollständiges Modell: EMG 17-REL/KSR-24/21-21-LC
✅ Basic Information
Teile-Nr.: 2940391
Produkttyp: DIN-rail mounted electromagnetic relay module (built-in miniature relay soldered, relay core non-removable)
Serie: EMG 17-REL
Herkunft: Deutschland
HS-Code: 85364190
Verbindung: Screw terminal M3
Abmessungen: 17.5(W) ×75(H) ×62.5(D) mm
Verpackung: 10 pcs per box, minimum order 1 Stk
⚙️ Core Electrical Parameters
Coil Supply: 24V AC/DC universal, typical current 18mA, power consumption 0.43W
Kontaktkonfiguration: 2 changeover contacts DPDT (2C)
Kontaktmaterial: AgNi silver nickel, suitable for medium-load applications
Rated Continuous Current: 5A; maximum inrush switching current 6A
Maximale Schaltspannung: 250V AC/DC
Mechanisches Leben: ca. 5×10⁷ Operationen
Betriebstemperatur: -20℃ ~ +40℃; Lagertemperatur: -20℃ ~ +70℃
Isolierung: Basic isolation between input and output, with status LED and surge suppression circuit
Wiring Cross-section: 0.2–4mm² solid wire / 0.2–2.5mm² flexible wire
📌 Terminal Definition
A1/A2: Spulenstromversorgung (24V AC/DC)
11, 12, 14: 1st Wechslerkontakt
21, 22, 24: 2und Wechslerkontakt
📋 Anwendungsszenarien
PLC/controller signal isolation, low-side control of high-power loads, Magnetventile, contactors and indicator light circuits.
Besonderheit: Integrated soldered construction, relay core cannot be replaced separately; interchangeable pluggable models belong to the RIF series.
🔁 Alternative Reference (Compatible Equivalents)
Gleiche Markenalternative: RIF-1-RSC-24DC/2X21 (pluggable relay core, einfachere Wartung, same width 17.5mm)
Inländische Alternative: 17.5mm width relay module, 24V AC/DC, 2 Wechslerkontakte, Typ mit Schraubklemmen
📎 Zertifizierungen
cULus, EAC, CE; konform mit EN 61810-1, EN50178
Full List of Phoenix Contact EMG-REL Relay Modules
Notiz: EMG-REL includes 3 sub-width series: EMG10-REL (10mm), EMG17-REL (17.5mm, Mainstream), EMG22-REL (22.5mm). All adopt soldered built-in relays (non-removable relay core), screw terminals and DIN rail mounting.
KSR = standard monostable electromagnetic relay; SG = latching relay; G = DC-only coil; W = AC-only coil; LC = LED indicator + surge suppression circuit
- EMG 17-REL / 17.5mm (Am häufigsten, einschließlich 2940391)
| Teile-Nr. | Vollständiges Modell | Spulenspannung | Contact Spec | Bemerkungen |
| 2940391 | EMG 17‑REL/KSR‑24/21‑21‑LC | 24V AC/DC | 2 changeover (2C) | ✅ Item you enquired, AgNi, mit LED & suppression circuit |
| 2940430 | EMG 17‑REL/KSR‑W230/21‑21‑LC | 230V und | 2 changeover (2C) | AC-only version, dual contacts |
| 2953854 | EMG 17‑REL/KSR‑24/21 | 24V AC/DC | 1 changeover (1C) | Single changeover, simplified version without LC |
| 2947420 | EMG 17‑REL/KSR‑12/21 | 12V AC/DC | 1 changeover (1C) | 12V universal model |
| 2947653 | EMG 17‑REL/KSR‑230/21 | 230V AC/DC | 1 changeover (1C) | 230V universal, dual A2 terminal |
| 2946353 | EMG 17‑REL/KSR‑230/21/SO54 | 230V AC/DC | 1 changeover (1C) | SO54 special contact configuration, reinforced insulation |
| 2949994 | EMG 17‑REL/KSR‑G24/SO38 BK | 24In DC | 1 normalerweise offen (NEIN) | Schwarzes Gehäuse, AgSnO₂, 80A inrush withstand, dedicated for lamp loads |
| 2946654 | EMG 17‑REL/SG‑B48/21/P | 48In DC | 1 changeover (1C) | SG latching relay, with forward diode circuit |
- EMG 10-REL / 10mm Narrow Version (Cabinet Space Saving)
| Teile-Nr. | Vollständiges Modell | Spulenspannung | Contact Spec | Bemerkungen |
| 2942108 | EMG 10‑REL/KSR‑G24/1‑LC | 24In DC | 1 normalerweise offen (NEIN) | Mit LED, AgNi for standard loads |
| 2941400 | EMG 10‑REL/KSR‑G60/1‑LC AU | 60In DC | 1 normalerweise offen (NEIN) | AU gold-plated contacts, for low-current weak signals |
- EMG 22-REL / 22.5mm Wide Version (High Isolation / Built-in Transistor Drive)
| Teile-Nr. | Vollständiges Modell | Spulenspannung | Contact Spec | Bemerkungen |
| 2951885 | EMG 22‑REL/KSR‑24/21 | 24V AC/DC | 1 changeover (1C) | High isolation, 5kV dielectric strength, allgemeiner Zweck |
| 2952350 | EMG 22‑REL/KSR‑G24/TRN35 | 24In DC | 1 changeover (1C) | Built-in NPN transistor, direct drive by low-current PLC outputs, hybrid relay |
- Suffix Explanation for Model Selection
KSR: Standard monostable electromagnetic relay
SG: Latching relay (remains state after power loss)
G: DC-only coil
W: Spule nur für Wechselstrom
LC: Integrated LED status indicator + coil surge suppression circuit (Freilaufdiode / Varistor)
/21: 1 Wechslerkontakt (1C: 11/12/14)
/21-21: 2 Wechslerkontakte (2C: 11-12-14 & 21-22-24)
SO38 / SO54: Special contact material (AgSnO₂, suitable for lamp loads and high inrush current)
AU: Gold-plated contacts, weak signal and low-level circuits
TRN35: Built-in NPN pre-drive transistor
- Schlüsselunterscheidung (Avoid Confusion with RIF Series)
EMG-REL: Relay soldered to base, non-replaceable relay core, cost-effective for fixed installation
RIF-REL / RIF-1: Plug-in replaceable relay core, separate base and relay, einfachere Wartung, same width for replacement
Application Fields of Phoenix Contact EMG-REL Relay Modules
Positionierung: Isolation relay for PLC / controller digital interfaces. Soldered integrated DIN-rail modules. Kernfunktionen: low-voltage signal isolation, signal amplification, level conversion, driving contactors, valves and indicator loads. Special variants (AU gold-plated, SO38 high-inrush, SG latching, TRN built-in transistor) for differentiated working conditions.
- Allgemeine industrielle Automatisierung (Am häufigsten, einschließlich 2940391)
Werkzeugmaschinen, Verpackungsausrüstung, Förderstrecken, Spritzgießmaschinen, woodworking machinery and custom automation control cabinets
Isolation for PLC DO channels: PLC 24V DC outputs driving contactors, Magnetventile, indicator lights and sound-light alarms
Türverriegelung, Statusrückmeldung, fault alarm circuits, auxiliary start-stop control
Vorteil: LC versions with LED and suppression circuit suppress reverse EMF and protect PLC modules
- Gebäudeautomation / HVAC
Air handling units, fresh air systems, Gebläsekonvektoren, air dampers and water valve actuator control
Beleuchtungskreise, Abluftventilatoren, Wasserpumpen, BA system signal interfaces
230V AC coil variants directly work with mains circuits; narrow EMG10-REL saves cabinet space
- Wasseraufbereitung & Kommunale Wasserversorgung / Drainage
Clean water tanks, sewage pump stations, chemische Dosiersysteme, bar screens, valve actuation and liquid level alarm signal isolation
Stable screw wiring suitable for long continuous operation in humid cabinet environments
- Erneuerbare Energie (PV, Energiespeicher, Windkraft)
Inverter cabinets, combiner boxes, auxiliary control for box-type transformers, fault alarm and status dry contact upload
Signal isolation to prevent strong electrical interference to acquisition boards; for onshore power stations (No ATEX certification, RIF explosion-proof series for hazardous areas)
- Logistiksortierung & Lagerautomatisierung
Sorters, Rollenbahnen, Stapler, AGV control cabinets, high-frequency switching signals, brake control and solenoid valves for sorting chutes
Hohe mechanische Lebensdauer (up to 5×10⁷ operations) for frequent switching cycles
- Infrastruktur: Tunnel & Road Lighting, Pumpstationen
Lichtsteuerung (SO38 models with AgSnO₂ contacts withstand high inrush current from incandescent and LED lamps, up to 80A inrush)
Remote start-stop control of fans and drainage pumps
- Testausrüstung, Instrumentierung & Medizinische Ausrüstung
AU gold-plated variants: Low contact resistance for mA-level weak signal switching, sensor signal switching and test fixtures; not suitable for high-power loads, gold layer may be damaged by arcing
- Andere Anwendungen
Control cabinet signal transfer, relay logic expansion, remote IO isolation, auxiliary dry contacts for fire alarm linkage
SG latching variants: retain switching state after power loss for state memory applications
✅ Selection Guide by Suffix
KSR standard type: General solenoid valves, Schütze, Kontrollleuchten (90% common applications, z.B. 2940391)
SO38 BK: Lamp loads, capacitive loads, hoher Einschaltstrom
AU gold-plated: Weak signal, instrument and low-current test circuits
SG latching: State retention after power failure
TRN35 built-in transistor: Direct drive by low-current PLC outputs without external pre-resistor
⚠️ Not Suitable Applications
EMG-REL complies with Class A EMC standards, not designed for consumer electronics. It does not have forcibly guided contacts, cannot be used for PLd / PLe safety circuits (safety relays with forcibly guided contacts required). No ATEX certification, not permitted in explosive hazardous areas.
Working Principle of Phoenix Contact EMG-REL Relay Modules
EMG-REL is an integrated electromagnetic relay module. Base, elektromagnetisches relais, LED indicator and suppression components are assembled in one DIN-rail housing. The relay core is permanently soldered and non-pluggable. Fundamentally, it is an electromechanical contact relay for low-voltage control of high-voltage circuits, electrical isolation and signal conversion.
- Basic Electromagnetic Principle
- Coil Side (Control Terminals A1/A2)
When rated coil voltage (DC24V / AC24V / AC230V etc.) is applied to A1 and A2, excitation current flows through the coil and generates magnetic flux on the iron core. The magnetic force overcomes spring tension and pulls the armature.
Coil energized → Armature pulls in → Contacts switch
Coil de-energized → Magnetic field disappears → Spring resets → Contacts return to original position
AC/DC universal coil versions (wie zum Beispiel 2940391) have coil windings designed for both AC and DC supply. Pure DC (Suffix G) and pure AC (suffix W) variants use different winding parameters.
- Contact Side (Load Terminals 11/12/14, 21/22/24)
Changeover contacts (1C / 2C) include normally closed (NC) und normalerweise offen (NEIN):
Spannungsloser Zustand: Gemeinsames Terminal (11) connects to NC (12) and disconnects from NO (14)
Spule unter Spannung: Gemeinsames Terminal (11) disconnects from NC (12) and connects to NO (14) to activate the external load (Magnetventile, Schützspulen, indicator lights etc.)
- Principle of Built-in Auxiliary Components (LC suffix, 2940391 is LC version)
LC = LED indicator + coil surge suppression circuit
LED-Statusanzeige: Wired parallel to the coil. Lights up when coil is powered to visually indicate drive signal presence. Integrated current-limiting resistor matched to rated voltage.
Surge suppression circuit (Freilaufdiode / Varistor):
Relay coils are inductive loads and produce high reverse EMF upon de-energization, which may damage PLC output chips.
Gleichstromspulen: Usually use freewheeling diodes to dissipate inductive energy
AC coils: Use varistor or RC snubber circuits to suppress AC voltage spikes
Models without LC suffix have no indicator or suppression; external surge protection must be added.
- Differentiated Principle of Special Sub-models
- SG Latching Version (EMG…SG)
Not conventional monostable relays. Permanent magnet inside:
Forward pulse power → Contacts close and stay latched after power removal
Reverse pulse power → Contacts reset and stay open after power removal
No continuous power required to maintain state, only pulse signal for switching, geringer Stromverbrauch.
- TRN35 Built-in Transistor Version (EMG…TRN35)
NPN pre-drive transistor integrated before coil: Low-current PLC signal drives the transistor first, then the transistor energizes the relay coil. Suitable for PLC channels with weak drive capacity.
- AU Gold-plated Contact Version
Gold plating on contact surface reduces contact resistance for mA-level weak signal switching. Not for heavy loads; gold plating is vulnerable to arc damage under high current.
- SO38 (AgSnO₂ Contacts)
Tin oxide silver contact material, arc-resistant and withstands high inrush surges, dedicated for lamp and capacitive loads to prevent contact welding.
- Electrical Isolation Logic
Basic insulation separates the coil control circuit and load contact circuit. It isolates PLC low-voltage side from high-voltage load side, blocks common-mode interference and prevents load-side faults from propagating into controller IO boards.
⚠️ Wichtig: This is only functional isolation. It is not a safety relay with forcibly guided contacts and cannot be used for PLe / PLd safety circuits.
- Simplified Working Flow (2940391, EMG17-REL/KSR-24/21-21-LC)
PLC digital output → 24V AC/DC supplied to A1/A2 → LED on, coil energized → Magnetic field pulls armature → Two changeover contacts switch synchronously → Solenoid valve / contactor energized
PLC output off → Coil de-energized → Suppression circuit dissipates residual coil energy → Spring resets contacts → Load de-energized
Schütz,Leistungsschalter,Sensor,Encoder,SPS,Konverter



















NH42-63-318x560.png)