Siemens 3RT2024-1AP00 Power Contactor

Produktpositionierung: SIRIUS Innovation series, Größe S0, 3-Pol-AC-Schütz. Designed for start/stop control of 3-phase motor and load, with screw terminals and DIN rail mounting. ✅ Model Breakdown 3RT2: New generation SIRIUS contactor series 024: Spezifikationscode, AC-3 12A / 5.5kW @400V 1: Built-in auxiliary contacts 1NO + 1NC A: AC coil P: 230V ...

  • Produktdetails

Produktpositionierung: SIRIUS Innovation series, Größe S0, 3-Pol-AC-Schütz. Designed for start/stop control of 3-phase motor and load, with screw terminals and DIN rail mounting.

✅ Model Breakdown

3RT2: New generation SIRIUS contactor series

024: Spezifikationscode, AC-3 12A / 5.5kW @400V

1: Built-in auxiliary contacts 1NO + 1NC

A: Wechselstromspule

P: 230V AC 50Hz

00: Schraubklemmen, no additional function modules

📋 Core Technical Parameters

ArtikelSpezifikationen
Hauptkontakte3P normally open, AC-3 12A; controls 5.5kW motor at 400V
HilfskontakteIntegrated 1NO + 1NC
SpulenspannungAC230V 50Hz
RahmengrößeGröße S0; Dimension 45×85×97 mm
VerdrahtungSchraubklemmen, DIN-Schienenmontage
Bemessungsisolationsspannung690V; Rated Impulse Withstand Voltage 6kV
Betriebstemperatur-25℃ ~ +60℃
Mechanische Ausdauer10 Millionen Operationen
Kurzzeitstromfestigkeit110A for 10s
SchutzklasseIP20 (terminals and front face)
HS-Code85364900

🧩 Application Scenarios

Start/stop and reversing control of 3-phase asynchronous motors

Fans, Wasserpumpen, belt conveyors and small machine tool loads

HVAC and automation control cabinet power circuits

🔁 Reference Replacement Models

  1. Upgrade relation: 3RT1024-1AP00 (old, eingestellt) → 3RT2024-1AP00 (successor)
  2. Same rating with different coil voltage:

3RT2024-1AN20: AC220V 50/60Hz wide-range coil

3RT2024-1BB40: DC24V-Spule

  1. Inländisches Äquivalent: Siemens 3RT6024-1AP00 (locally manufactured, identische elektrische Parameter)

⚠️ Auswahl & Wartungshinweise

  1. Zum Ersatz, verifizieren: AC-3 current rating, Spulenspannung, quantity of auxiliary contacts
  2. Recommended matched thermal overload relay: 3RU2124 series (for 5.5kW motors)
  3. Optionales Zubehör: Überspannungsschutz, seitlich angebrachte Hilfskontakte, mechanische Verriegelung
  4. Second-hand inspection checklist: coil resistance measurement, main contact erosion check, pull-in & release action test

Siemens 3RT2024-1AP00 Full Technical Data

SIRIUS 3RT2, S0-Rahmen, 3-Pol-Leistungsschütz, Schraubklemmen, DIN-Schienenmontage

  1. Hauptkontakte (Stromkreis)
ArtikelSpezifikationen
Polen3P, 3 normalerweise offene Hauptkontakte
Bemessungsbetriebsstrom Ie (AC-3)12A bei 400 V
Nennleistung des Motors (AC-3)5.5kW for 3-phase motor @400V
Rated current for resistive load (AC-1)20A
Bemessungsisolationsspannung Ui690V
Bemessungsstoßspannungsfestigkeit Uimp6kV
AC-4 rated current12.5A bei 400 V
Kurzzeitiger Stromwiderstand110A, 10S
Max cross-section of main circuit cable10mm簡
  1. Built-in Auxiliary Contacts

Konfiguration: 1NEIN + 1NC (integriert, nicht entfernbar)

Auxiliary contact rating: AC-15 3A / DC-13 0.5A

Max voltage for auxiliary contacts: 400V und

III. Spulenparameter (Steuerkreis)

ArtikelSpezifikationen
BemessungsspulenspannungAC230V, 50Hz
Coil operating voltage range0.8 ~ 1.1 × Ue (184V ~ 253V)
Apparent power during pull-in65VA
Apparent power during holding6VA
SpulentypWechselstromspule
  1. Lebensdauer & Betriebsfrequenz

Mechanisches Leben: 10,000,000 Operationen

AC-3 electrical life: ca. 1,000,000 Operationen

Max operating frequency under AC-3: 1000 Zyklen/Stunde

Max operating frequency under AC-4: 300 Zyklen/Stunde

  1. Umweltfreundlich, Dimensional & Mechanische Daten

Rahmengröße: Größe S0

Gesamtdimension: W45mm × H85mm × D97mm

Nettogewicht: ca. 0.405kg

Montage: 35mm DIN-Schiene, or plate mounting via screws

Terminals: Schraubklemmenklemmen

Betriebsumgebungstemperatur: -25℃ ~ +60℃ (inside cabinet)

Lagertemperatur: -55℃ ~ +80℃

Schutzklasse: IP20 (front face and terminals)

  1. Standards & Zertifizierungen

Compliance-Standard: IEC 60947-4-1 / GB 14048.5

Zertifizierungen: CCC, CE, UL

HS-Code: 85364900

VII. Modelldefinition

3RT2: New generation SIRIUS contactor series

024: Spezifikationscode, AC-3 12A, S0-Größe

1: Eingebaute 1NO+1NC-Hilfskontakte

A: Wechselstromspule

P: AC230V 50Hz

00: Schraubklemmen, no built-in surge suppression

VIII. Matching Selection Reference

  1. Thermisches Überlastrelais: 3RU2124 (matched for 5.5kW motors)
  2. Zubehör: seitlich angebrachte Hilfskontakte, RC surge absorber, mechanical interlock module
  3. Locally manufactured equivalent model: 3RT6024-1AP00, völlig identische elektrische Parameter

Siemens 3RT2024-1AP00|Application Fields & Load Types

Specification baseline: S0-Rahmen, AC-3 12A / 5.5kW@400V, 3-Pol-AC-Schütz. Primarily used for direct-on-line (DOL) starting of 3-phase motors; also suitable for AC-1 resistive loads. Integrated 1NO+1NC auxiliary contacts for PLC feedback and interlock circuits.

🏭 1. General Machinery Manufacturing (Am häufigsten)

Kleine Werkzeugmaschinen: Kühlpumpen, lubrication pumps, chip removal motors

Conveying equipment: Förderbänder, Rollenlinien, Aufzüge

Pneumatic systems: start/stop for small piston air compressor motors

Packaging equipment: stretch wrappers, Kartonverschließer, small stirring motors

Holzbearbeitung & Kunststoffmaschinen: Aktenvernichter, auxiliary extruder motors, Fans

🌬️ 2. HVAC & Gebäudeautomation

Air handling unit fans, Kühlwasserpumpen, condensate pumps for central air conditioning

Small compressors, exhaust fans and fresh air fans of air-cooled / water-cooled units

Building control cabinets, fire smoke exhaust fans (with thermal relay protection)

Widerstandslasten: electric heating elements, commercial lighting circuits (AC-1, max.20A)

🥤 3. Essen, Getränk & Pharmazeutische Industrie

Wash pumps, agitator tanks, Transferpumpen, small drive motors for filling lines

Fans and pump sets for CIP cleaning systems

Fans and circulating water pumps in cold storage and clean rooms

Vorteile: Wide temperature range -25~+60℃, CCC/CE/UL certifications, suitable for clean control cabinets

💧 4. Wasseraufbereitung & Water Supply/Drainage

Small sewage pumps, Reinwasserpumpen, chemical dosing agitator motors

Rainwater harvesting, greywater systems, filter drive motors

Local pump station control cabinets, PLC remote start-stop + operation feedback (via built-in auxiliary contacts)

🚗 5. Automobil & Component Automation

Tooling fixtures, roller conveyors at workstations, workstation cooling fans

Exhaust fans in spray booths, small hydraulic station motors

Motor start-stop control for test benches

⚙️ 6. Andere industrielle Anwendungen

  1. MCC Motor Control Centre: 5.5kW motor circuits in drawer units; forms complete motor protection unit together with circuit breaker and thermal relay
  2. VFD-Bypass: Bypass switching for small variable frequency drives (Notiz: Frequent switching is not recommended)
  3. Small hydraulic stations: Start-stop control for hydraulic oil pump motors
  4. Solar / energy storage auxiliary: Cabinet cooling fans and circulating pump control

✅ Applicable Load Types

  1. AC-3: 3-phase asynchronous motor (5.5kW@400V), Direkt online (DOL) starting (primary use)
  2. AC-1: Widerstandslasten, electric heating, incandescent lamp groups, max.20A
  3. AC-4: Motor inching and forward/reverse rotation (Notiz: limited operating frequency, max.300 cycles/hour)

❌ Non-suitable Scenarios

Motors rated >5.5kW

Heavy frequent inching and heavy shock duty (long-term high frequency under AC-4)

Capacitor reactive power compensation (special 3RT26 capacitor contactor required; this model cannot be substituted)

DC main circuit loads (this is an AC contactor)

💡 Selection Key Points

Built-in 1NO+1NC mirror auxiliary contacts for running feedback, fault interlocking and safety circuits, ideal for PLC automation control

DIN-Schienenmontage, compact width (45mm), suitable for dense cabinet layout

Siemens 3RT2024-1AP00|Cross-Brand Equivalent Comparison Table

Baseline specification: 3P, AC-3 12A, 5.5kW@400V, AC230V 50Hz coil, built-in 1NO+1NC auxiliary contacts, Schraubklemmen, DIN-Schiene

⚠️ Hinweis: Electrically equivalent replacement; Gesamtabmessungen, cutouts and accessories may not be fully compatible. Verify mounting dimensions and auxiliary contact configuration before cabinet retrofit.

MarkeÄquivalentes ModellBemerkungen
Siemens (Gleiche Marke)3RT6024-1AP00Inländischer SIRIUS, fully identical parameters, local replacement; obsolete predecessor: 3RT1024-1AP00
Schneider ElectricLC1D12P7 (TeSys Deca)3P AC-3 12A, AC230V-Spule, built-in 1NO+1NC; same 45mm width, most popular direct replacement
ABBAF12-30-11-13 (AF series)3S. 12A, AC230V-Spule, built-in 1NO+1NC; AF wide-voltage coil, hohe Vielseitigkeit
Rockwell AB100-C12*11, coil code A0 (AC230V)100C-Serie, 3S. 12A, integrated 1NO+1NC auxiliary contacts
OMRONCJX2-1211 AC230V (Omron contactor)3S. 12A, 1NO+1NC, Schraubklemmen
LOVATOBF1211A230BF series, 3P AC-3 12A, AC230V, 1NO+1NC
SauberNXC-12 11 AC220/230VMainstream domestic model, 3S. 12A, 1NO+1NC, kostengünstig
DELIXICJX2s-1211 AC230VCJX2s series, 12A, 1NO+1NC

✅ Key Notes for Cross-brand Replacement (Engineering)

  1. Hilfskontakte: The reference model has built-in 1NO+1NC. Many economical models only have 1NO (z.B. LC1N1210), cannot be directly replaced due to missing NC feedback contact. Must select suffix 1211 (1NO+1NC).
  2. Spulenspannung: Baseline AC230V 50Hz. Distinguish:

M7=AC220V 50/60Hz; P7=AC230V 50Hz (fully matches coil of this model)

  1. Montagemaße: Siemens S0 frame width 45mm; Schneider LC1D12, ABB AF12 also 45mm width, directly mountable on DIN rail, cutout generally compatible. Depth differs; verify depth if cabinet space is limited.
  2. Matched Thermal Relay: Thermal relay model must be changed when switching brand. Contactors and thermal relays from different brands cannot snap-fit together, separate mounting required.
  3. Mechanische Verriegelung & Zubehör: Cross-brand accessories not interchangeable. Reversing interlock modules and side-mounted auxiliary contacts cannot be mixed.

❗ Quick Selection Recommendation

Direct replacement for project, hohe Kompatibilität: Schneider LC1D12P7

Cost reduction with domestic product: CHNT NXC-12 11 AC230V

Overseas project, wide voltage requirement: ABB AF12-30-11-13

Siemens 3RT2024-1AP00 (S0 Frame) Montagemaße

Einheit: mm

Gesamtabmessungen

Breite W:45

Höhe H:85

Tiefe D:97 (from DIN rail backplate to front of terminals)

Montagemethoden

  1. DIN-Schienenmontage: Standardmäßige 35-mm-DIN-Schiene (DIN EN 60715), clip-on installation
  2. Schraubenbefestigung: Can also be plate-mounted directly on backplate (without rail)

Montageausrichtung: ±180° rotation on vertical plane; ±22.5° tilt forward/backward allowed

Cabinet Clearance for Heat Dissipation

Side-by-Side-Installation: 0mm clearance (can be mounted tightly together)

Minimum top, bottom and front clearance: 10mm

Clearance to earthed metal parts: ≥6mm laterally, ≥10mm top/bottom/front

⚠️ Dimension change after adding accessories (Important for cabinet cutout design)

  1. Front-mounted auxiliary contact block: Breite & height unchanged, depth increases by 44mm
  2. Side-mounted auxiliary contacts: Höhe & depth unchanged, width increases

This unit has built-in 1NO+1NC auxiliary contacts; dimension remains 45×85×97 without extra accessories.

Gewicht

Nettogewicht: 0.405kg

Ersatzreferenz

Schneider LC1D12P7 also has 45mm width, compatible DIN rail position; but depth varies slightly. Double-check depth for cabinet retrofit with limited depth.

Vorher: