Siemens 3RT2025-1AC20 Motor Contactor

Produktserie: SIRIUS 3RT2 3-pole Power Contactor (Motor Contactor) Full Order No.: 3RT2025-1AC20 ✅ Model Code Explanation 3RT: SIRIUS contactor series 2: New generation SIRIUS Innovations 0: 3-pole motor contactor 25: S0 frame size, AC-3 17A, rated for 7.5kW motor at 400V 1: Built-in 1NO + 1NC auxiliary contacts A: AC coil C: 24V und, ...

  • Produktdetails

Produktserie: SIRIUS 3RT2 3-pole Power Contactor (Motor Contactor)

Full Order No.: 3RT2025-1AC20

✅ Model Code Explanation

3RT: SIRIUS contactor series

2: New generation SIRIUS Innovations

0: 3-pole motor contactor

25: S0 frame size, AC-3 17A, rated for 7.5kW motor at 400V

1: Built-in 1NO + 1NC Hilfskontakte

A: Wechselstromspule

C: 24V und, 50/60Hz-Spule

20: Screw-type terminal

✅ Core Technical Specifications

ArtikelParameter
Main Contacts Poles3P (3 normalerweise offene Hauptkontakte)
Rated Current AC-317A bei 400 V
Rated Current AC-1 (ohmsche Last)40A
Max. Betriebsspannung690V
Spule24V und, 50/60Hz
Hilfskontakte1NEIN + 1NC
RahmengrößeS0
VerkabelungstypSchraubklemmen
MontageDIN-Schienenmontage
SchutzklasseIP20 (Front / Terminals)
Umgebungstemperatur-25℃ ~ +60℃
Mechanisches Leben10 Millionen Operationen

✅ Typical Applications

Start/stop control of 3-phase asynchronous motors (Fans, Pumps, Förderer)

HVAC, Verpackung, machine tool automation control cabinets

Can be matched with 3RU2 thermal relays for motor overload protection; Hilfskontakte, surge suppressors and mechanical interlock modules can be added.

✅ Coil Variant Reference for Selection & Ersatz

3RT2025-1AC20: 24V und

3RT2025-1AG20: 110V und

3RT2025-1AN20: 220V und

3RT2025-1AP00: 230V und

3RT2025-1BB40: 24In DC

✅ Replacement Information

  1. Siemens internal replacement: Old model 3RT1025-1AC20 (eingestellt). Direct replacement with 3RT2025-1AC20, mounting dimensions are compatible.
  2. Domestic alternative reference: Chint NC1-18, Delixi CJX2-1810 (match coil voltage and confirm 1NO+1NC auxiliary contacts).

✅ Troubleshooting Guidelines

  1. Coil energized but no pull-in: Measure A1/A2 for 24V AC; check burnt coil and loose terminals.
  2. No output on main circuit after pull-in: Main contacts erosion, inspect L1/L2/L3 and T1/T2/T3.
  3. Repeated coil burnout: Overvoltage or surge on coil circuit. RC snubber module is recommended for parallel connection.
  4. Abnormal auxiliary contacts: Auxiliary contacts worn out. External auxiliary contact modules can be fitted.

The built-in 1NO+1NC auxiliary contacts integrated inside 3RT2025-1AC20 cannot be replaced separately.

They are integrated into the contactor housing with no spare parts available. Once the built-in auxiliary contacts are damaged, the whole contactor must be replaced.

Distinguish two concepts:

  1. Eingebaute Hilfskontakte (1NO+1NC): Integrated inside S0 frame body, non-detachable and non-replaceable individually.
  2. External add-on auxiliary contact modules (front-mounted / side-mounted): Detachable and replaceable separately, classified as accessories.

📌 External Auxiliary Contact Module Selection (Abnehmbar & Austauschbar)

1) Front-mounted (fit only 1 piece on front face)

3RH2911-1HA11: 1NO+1NC

3RH2911-1HA22: 2NO+2NC

2) Seitlich montiert (can be fitted on left or right side, max 2 Stücke, one on each side)

3RH2921-1DA11: 1NO+1NC

3RH2921-1DA20: 2NEIN

3RH2921-1DA02: 2NC

🛠️ Fault Handling Solutions

  1. Burnt built-in auxiliary contacts: No spare parts available; replace the entire 3RT2025-1AC20 contactor.
  2. Damaged external auxiliary contact module: Remove the faulty auxiliary contact module and replace it with the same model accessory; reuse the contactor body.
  3. Insufficient contact quantity: Add front/side mounted auxiliary contact modules listed above.

⚠️ Additional Remarks

For S0 frame (3RT2025), no separate spare main contact kits are available. The whole contactor needs replacement when main contacts are burned. Only S2 and larger frame contactors have independent spare main contacts.

Siemens 3RT2025-1AC20 Main Contacts vs Auxiliary Contacts

  1. Definition & Funktion

Hauptkontakte (L1/L2/L3 ↔ T1/T2/T3)

Funktion: Switch high-power main circuit, directly turn on/off motors and loads

Menge: 3 normally-open sets (3P)

Bewertung: AC-3 17A@400V for 7.5kW motor; AC-1 40A for resistive load

Schaltung: High-power main circuit

Struktur: Oversized thick silver-alloy contacts with arc extinguishing chamber to withstand breaking arc under high current

Bemerkung: S0-Rahmen, main contacts cannot be replaced individually. Full contactor replacement required after damage.

Hilfskontakte (Built-in 1NO+1NC, expandable with 3RH accessories)

Funktion: Signalrückmeldung, Verriegelung, einrastend (control circuit logic, not for high-power load driving)

Menge: Built-in 1NO +1NC. Expandable by external modules

Bewertung: Low current, typically ≤6A for PLC input, relay coils and indicator lamps

Schaltung: Low-power control circuit

Struktur: Small silver contacts without heavy-duty arc extinguishing, only for small current breaking

Bemerkung: Built-in auxiliary contacts are integrated and non-replaceable; external 3RH auxiliary modules can be assembled and replaced individually.

  1. Vergleichstabelle
VergleichsartikelHauptkontakteBuilt-in Auxiliary Contacts
KlemmenmarkierungL1/L2/L3, T1/T2/T313/14 (NO normally open), 21/22 (NC normally closed)
Load CapacityHigh current for motors and heatersLow current only for signal, interlock and latching
NennstromAC-3:17A bei 400 VTypically 6A (AC-15)
LichtbogenlöschungWith arc chute for heavy arcNo heavy-duty arc suppression, only for minor arc
Individually Replaceable❌ Not available (S0-Rahmen)❌ Built-in non-replaceable; ✅ External auxiliary modules replaceable
Typische VerwendungMain power supply switching for motorsContactor latching, running feedback, Verriegelung, Anzeigelampe, PLC acquisition
  1. Typical Wiring Example
  2. Hauptkontakte: 3-phase power supply feeds L1/L2/L3 on contactor top terminals; bottom terminals T1/T2/T3 connect to motor.
  3. Hilfskontakte

13-14 (NO normally open): Latching circuit or send “contactor energized” feedback signal to PLC.

21-22 (NC normally closed): Electrical interlock (forward/reverse circuit, prevent simultaneous pull-in of two contactors causing 3-phase short circuit).

  1. Fault Differentiation

Main Contacts Failure: Motor weak rotation, Phasenverlust, overheating or arcing at terminals, load cannot power up normally.

Auxiliary Contacts Failure: Motor can start/stop normally, but latching fails, loss of feedback signal, interlock invalid. Main power circuit remains unaffected.

  1. Wichtige Warnung

Never use auxiliary contacts to switch motors, heaters or other high-power loads. Contact erosion will occur rapidly. High-power loads must be wired via main contacts.

Siemens 3RT2025-1AC20|Application Scenarios of Main Contacts and Auxiliary Contacts

  1. Hauptkontakte (L1/L2/L3 ↔ T1/T2/T3, 3 sets of high-power normally-open contacts)

Core purpose: Switch high-power main circuit and carry load operating current

✅ Applicable scenarios:

  1. Direct start-stop of 3-phase motors (am häufigsten): Pumps, Fans, Förderer, Luftkompressoren, machine tool spindle motors. This model is rated for 7.5kW 400V 3-phase motors.
  2. 3-phase resistive load control: 3-phase heating elements, large 3-phase dehumidification heaters, max 40A under AC-1 rating.
  3. High-power switching in power distribution circuits: Power switching for heavy loads inside control cabinets.

❌ Not suitable for:

PLC signals, Anzeigelampen, small relay coils and other low-current control circuits;

Logical interlock or status feedback.

Merkmale: Equipped with arc extinguishing chamber and thick silver contacts, withstand motor inrush current and breaking arc.

  1. Hilfskontakte (Built-in 1NO+1NC, Terminals:13-14 NEIN,21-22 NC; expandable with 3RH external modules)

Core purpose: Low-current signal in control circuit, only transmit logic status, no high-power load driving

✅ Normally Open NO (13-14) Typische Szenarien

  1. Contactor latching (self-holding): Maintain coil energized after releasing start pushbutton to keep motor running continuously.
  2. Running status feedback: Send signal to PLC, DIO module or indicator lamp for HMI to display “contactor pulled in, equipment running”.
  3. Sequential startup: Use NO contact to trigger coil of next relay/contactor after this contactor pulls in, to realize sequential start-up.

✅ Normally Closed NC (21-22) Typische Szenarien

  1. Electrical interlock (classic application): Connected in series to coil circuit of reverse contactor in forward/reverse control circuit, to avoid 3-phase short circuit caused by simultaneous pull-in of forward and reverse contactors.
  2. Fehler / stop feedback: NC closed when contactor is open, used for stop status acquisition.
  3. Safety circuit interlock: NC contact conducts when contactor is de-energized, serving as ready signal.

Auxiliary contacts are low rated (AC-15 approx.6A), only for low-current control circuits. Do NOT use auxiliary contacts to directly control motors or high-power heating loads.

Quick Selection Rule

Motoren, high-power heaters, 3-phase power → Main Contacts

Einrastend, Verriegelung, PLC signal, running indicator lamp, logic linkage → Auxiliary Contacts

On-site Quick Fault Diagnosis

Motor läuft nicht, Phasenverlust, hot or arcing terminals → Most likely main contact fault

Motor can start and stop, but stops immediately once start button released, no running feedback, risk of short circuit due to failed interlock → Most likely auxiliary contact fault