Controlador de seguridad programable ABB 2TLA020070R1700 - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

 Controlador de seguridad programable ABB 2TLA020070R1700 - contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor

eléctrico/

Controlador de seguridad programable ABB 2TLA020070R1700

Marca: ABB-Jokab Safety;Producto: Controlador de seguridad programable (PLC de seguridad) Model Definition 2TLA020070: Base part number for Pluto-series safety controllers R1700: Order suffix for hardware revision B46 v2 Full designation: Pluto B46 v2 I-O Configuration (Total 46 Agujas) 24 fail-safe inputs (safety inputs) 16 canales configurables: non-safe output / safety input 4 independent safety relay outputs 2 ...

  • Detalles del producto

Marca: TEJIDO-Seguridad Jokab;Producto: Programable Controlador de seguridad (Seguridad SOCIEDAD ANÓNIMA)

Definición del modelo

2TLA020070: Base part number for Pluto-series safety controllers

R1700: Order suffix for hardware revision B46 v2

Designación completa: Pluto B46 v2

I-O Configuration (Total 46 Agujas)

  1. 24 fail-safe inputs (safety inputs)
  2. 16 canales configurables: non-safe output / safety input
  3. 4 independent safety relay outputs
  4. 2 independent safety transistor outputs

Equipped with Pluto Safety-Bus safety fieldbus for networking expansion

Key Safety & Especificaciones eléctricas

ArtículoParámetro
Fuente de alimentación24 VCC
Nivel de seguridadSIL3 / PLe (EN ISO 13849‑1)
Clase de protecciónIP20 (DIN‑rail cabinet mounting)
TerminalesTerminales tipo tornillo
Contactos de relé2 A, CA 250 V. / DC50V
Temperatura de funcionamiento‑10 ℃ ~ +55 ℃
Humedad5‑95 %, sin condensación
Software de programaciónPluto Manager
ComunicaciónModbus‑TCP native; expandable via gateways for Profibus/EtherNet‑IP, etc..

Aplicaciones típicas

Control de seguridad de la máquina: Molestar, puertas de seguridad, cortinas de luz de seguridad, control de dos manos, monitoreo de velocidad seguro; red de seguridad de múltiples controladores, proyectos de seguridad independientes de alta E/S.

Referencia de comparación de series

Plutón B20 v2: 20 puntos de E/S, unidad compacta

Pluto B46 v2 (2TLA020070R1700): 46 puntos de E/S, modelo de alta densidad

Nota: B46 v2 indica la versión de hardware v2. La revisión anterior B46 tiene un número de pedido diferente; Los programas son compatibles para la migración..

Accesorios relacionados

  1. Cable de programación: Cable de programación USB Plutón
  2. Puertas de enlace: PUERTA-P2 (Profibus), PUERTA-EIP (EtherNet-IP) para conexión a hosts PLC estándar
  3. Software: Pluto Manager (disponible para descargar desde el sitio web oficial de ABB)

Unidad de repuesto / Lista de verificación de inspección de unidades de segunda mano

  1. Prueba de encendido y verificación del funcionamiento del LED de estado para todos los canales
  2. Lea la revisión del firmware para confirmar la variante de hardware v2
  3. Prueba funcional completa de carga y descarga del programa.
  4. Realizar pruebas de conmutación basadas en carga en salidas de relé
  5. Inspeccione los terminales en busca de marcas de quemaduras y el panel posterior en busca de corrosión.

ABB Plutón B46 v2 (2TLA020070R1700) Contenido clave del manual de programación

Hardware: Pluto B46 v2; Herramienta de software: Pluto Manager (descarga gratuita a través del sitio web de ABB)

Documento oficial de referencia completa.: Pluto Safety-PLC Manual de programación, Doc. IDENTIFICACIÓN: 2TLC172002M0218 (original en inglés; no hay traducción oficial completa al chino)

📘 Resumen del índice (Manual de programación oficial)

  1. Precauciones de seguridad (revisión de la lógica de seguridad; pruebas obligatorias de máquina completa; El software no puede detectar errores lógicos.)
  2. Instalación del Administrador de Plutón, Modo DEMOSTRACIÓN, activación de licencia
  3. Flujo de trabajo completo para nuevos proyectos
  4. Configuración de E-S de hardware (Definición de E-S de 46 puntos específica de B46-v2)
  5. Direccionamiento y denominación simbólica de variables.
  6. Programación de lógica de escalera + Biblioteca de bloques de funciones de seguridad con certificación TÜV
  7. Registros, registros del sistema, procesamiento de señales analógicas
  8. Red multimaestro Pluto-Safety-Bus (máximo. 32 Unidades de Plutón)
  9. Descarga del programa, Duplicación del programa IDFIX, protección con contraseña
  10. Monitoreo en línea, diagnóstico de fallas, códigos de error
  11. Comunicación Modbus-TCP, interfaz host-PLC a través de puertas de enlace
  12. Ejemplos de programas, actualización de firmware, notas de compatibilidad de hardware

🛠️ B46 v2 Hardware I-O Configuration Mandatory Programming Settings

Nro. de orden: 2TLA020070R1700 Pluto B46 v2

I: 24 fixed fail-safe inputs

IQ: 16 multi-function channels, software-selectable: Failsafe Input / Non-safe Output

QR: 4 independent safety relay outputs (SIL3/PLe)

QT: 2 independent safety transistor outputs (SIL3/PLe)

IQ channel operating mode must be defined in the Pluto Manager hardware configuration page. Mismatch between wiring and software configuration triggers hardware faults.

🔧 Standard Development Workflow in Pluto Manager

  1. Create new project, select hardware type `Pluto B46 v2`, assign Safety-Bus station address
  2. Configure I-O parameters

I-inputs: Dynamic / static input mode (static for light-curtain OSSD signals; dynamic for dual-channel E-stop and safety-gate circuits)

IQ channels: Individually set as Failsafe Input or Non-safe Output

  1. Symbolic variable assignment: I-input, Q-output, M-retentive memory, GM-global memory (bus-shared), R-registers
  2. LD ladder-logic programming: invoke TÜV-certified safety function-blocks (Molestar, puerta de seguridad, control de dos manos, light-curtain muting, monitoreo de velocidad seguro)
  3. Compile project, resolve errors, assign program password
  4. Download program via USB cable. For multi-unit networks, programs are automatically distributed over Pluto-Safety-Bus to all stations
  5. Monitoreo en línea: Forced-signal testing permitted only during commissioning, followed by complete machine safety validation
  6. Opcional: IDFIX-PROG hardware program copy module for spare-unit replacement without a PC

📦 Frequently Used TÜV-Certified Safety Function Blocks

Function BlockSolicitud
Block 1‑2Dual‑channel E‑stop (with reset and line‑fault detection)
Block4‑5Safety‑gate monitoring
Block16Two‑hand control
Block18‑19Light‑curtain muting
Block28‑29Safe encoder, velocidad / position monitoring
Safety Timer (safe off‑delay)SIL3‑compliant safety delay; Los temporizadores estándar de uso general NO se deben utilizar para la lógica de seguridad.

⚠️ Restricciones críticas de programación de seguridad

  1. Las funciones relacionadas con la seguridad deben utilizar bloques de funciones certificados por TÜV. La implementación de lógica de seguridad exclusivamente con lógica de escalera genérica anula el cumplimiento de SIL3/PLe.
  2. Las IQ configuradas como salidas no son salidas seguras y no se deben utilizar para la desconexión de carga relacionada con la seguridad.. El corte de seguridad debe utilizar salidas de relé QR o salidas de transistor QT.
  3. Pluto-Bus opera en arquitectura totalmente maestra. Cada controlador controla sus salidas locales.; La memoria global de GM maneja el intercambio de datos entre unidades.
  4. La descarga del programa requiere contraseña. El modo DEMO solo permite ver el proyecto; Las funciones de compilación y descarga están deshabilitadas..
  5. Reemplazo de unidad de repuesto: El programa se puede descargar vía USB, o duplicado rápidamente usando el módulo IDFIX-PROG.

📑 Lista de manuales relacionados

Título del manualIdentificación del documentoObjetivo
Manual de programación de Plutón2TLC172002M0218Referencia de programación básica
Manual de hardware de Plutón2TLC172001M0112Instrucciones de cableado de hardware
manual de puerta de enlace2TLC172003MxxxxModbus-TCP / Profibus / Documentación de la puerta de enlace EtherNet‑IP

💻 Descarga de software

Pluto Manager: Descarga gratuita desde el sitio web oficial de ABB bajo productos de seguridad de bajo voltaje. Coincidir con la revisión del firmware; B46 v2 requiere firmware compatible de la serie v2.

❗ Breve referencia de códigos de falla (B46v2)

Er20: No hay ningún programa de usuario presente

Er24: error de programa

Er31: El programa IDFIX no coincide

Er4x: Fallo del canal de E-S (circuito abierto de entrada dinámica / cortocircuito)

Compatibilidad del sistema operativo Pluto Manager (para Plutón B46 v2)

Plataforma exclusiva de Windows. No hay versiones nativas de MacOS o Linux. Referencia: Manual de programación Doc.. ID 2TLC172002M0218

✅ Validado oficialmente & Apoyado (Recomendado)

  1. ventanas 7 SP1 (32-poco / 64-poco) Profesional / Empresa / Último
  2. ventanas 10 (32-poco / 64-poco) Profesional / Empresa (Más utilizado para la puesta en marcha industrial.)

Para hardware B46 v2, utilizar versiones recientes de Pluto-Manager; Se prefiere Windows 10-64 bits.

⚠️ Funcional pero NO Validado Oficialmente (probado en el campo, sin cobertura de garantía del fabricante)

ventanas 8 / ventanas 8.1 (32-poco / 64-poco)

Servidor Windows 2008R2 / 2012 / 2012R2 / 2016 / 2019

ventanas 11: Se instala y opera en implementaciones del mundo real.. La comunicación USB puede requerir ajustes del modo de compatibilidad. No incluido en la matriz de soporte oficial de ABB. ventanas 10 sigue siendo el preferido para la puesta en marcha del sitio.

❌ No recomendado / No compatible

  1. Vista de Windows: Instalación posible, componentes de seguridad insuficientes, no recomendado
  2. Windows XP y anteriores: no se puede ejecutar
  3. Mac OS, linux: Sin compilaciones nativas; operación solo a través de la máquina virtual de Windows (VMware / VirtualBox)

📋 Dependencias de software (instalado automáticamente; Los componentes faltantes causan errores de tiempo de ejecución.)

  1. Marco Microsoft .NET 4.6.1
  2. VisualC++ 2005, 2010 Bibliotecas en tiempo de ejecución

🖥️ Requisitos mínimos de hardware

UPC: 1 GHz o superior (x86/x64)

RAM: 2 ES (32-poco) /3 ES (64-poco)

disco duro: 3 GB de espacio de almacenamiento libre

💡 Notas prácticas de funcionamiento

  1. ventanas 11 operación: If USB programming-cable communication fails, right-click application shortcut, enable compatibility mode for Windows 8 and run as administrator.
  2. Modo DEMOSTRACIÓN: No license key required. Program download and online monitoring functions require valid license.
  3. Software-hardware matching: Pluto Manager version ≥ V14. Older software revisions cannot recognize v2 hardware.

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje