ABB ACS580-01-246A-4 Variable Frequency Drive

ACS580-01-246A-4 ACS580: ABB new generation general wall-mounted VFD series 01: Standard integrated wall-mounted unit (non-cabinet modular type 04) 246A: Corriente de salida nominal 246 A 4: 3-phase input voltage class 380~480 V AC Optional protection suffixes: No suffix = IP21 standard version; +B056 = IP55 high-protection dustproof and waterproof version Frame size: R8 Order material numbers: ...

  • Detalles del producto

ACS580-01-246A-4

  1. ACS580: TEJIDO new generation general wall-mounted VFD serie
  2. 01: Standard integrated wall-mounted unit (non-cabinet modular type 04)
  3. 246A: Corriente de salida nominal 246 A
  4. 4: 3-phase input voltage class 380~480 V AC

Optional protection suffixes:

No suffix = IP21 standard version; +B056 = IP55 high-protection dustproof and waterproof version

Tamaño del marco: R8

Order material numbers: 3AUA0000080507 (IP21), 3AUA0000083582 (IP55)

  1. Potencia nominal / Current Ratings (400 V Grid)
Tipo de cargaCorriente de salidaPotencia del motor adaptadaOverload Specification
Estándar / Light Load (aficionados & Zapatillas) ILd234 A132 kilovatios110% para 1 min every 10 mín.
Rated Nominal Current In246 A132 kilovatiosContinuous rated operation
Heavy Load (Transportadores / Extruders) IHd206 A110 kilovatios150% para 1 min every 10 mín.

Apparent output capacity: 170 kVA; Overall efficiency ≥ 98%

III. Parámetros eléctricos básicos

  1. Input Power Supply

Phases: 3-fase (3Ph)

Voltaje: AC 380~480 V ±10%

Mains frequency: 47.5~63 Hz

Power factor correction: Built-in DC choke (standard for R8 frame)

  1. Output Drive

voltaje de salida: 0~Uin (0~480 V)

Frecuencia de salida: 0~500 Hz

Control algorithms: Scalar V/F + Sensorless Flux Vector Control

Torque performance: 100% rated torque available at 0.5 Hz; Torque response <10 ms

  1. Standard Built-in I/O Terminals (Onboard Control Board)
TipoCantidadSpecification Description
Analog Input AI2 canalesSwitchable 0~10 V / 4~20 mA
Analog Output AO2 canales0~10 V / 4~20 mA
Digital Input DI6 canales24 VDC NPN/PNP compatible
Digital Output DO3 canalesRelay dry contacts (250 VACACIONES / 2 A)
Communication Port1 × RS485Estándar Modbus RTU; expandable to Profinet/Profibus/EtherNet/IP
USB Port1 canalPC commissioning, parameter upload & download
  1. Full Standard Protection Functions

sobrecorriente, sobretensión, subtensión, sobrecarga, IGBT overtemperature, motor stall, falla a tierra, pérdida de fase, protección de puesto, cooling fan fault, protección contra cortocircuitos, parameter loss alarm.

  1. Mechanical Dimensions & Peso

IP21 Standard Wall-mounted (ACS580-01-246A-4)

Overall size: h 615 × W 270 × D 250 milímetros

Peso neto: 21 kilos

IP55 High-protection Model (ACS580-01-246A-4+B056)

Overall size: h 965 × W 300 × D 452 milímetros

Peso neto: 77 kilos

Montaje: Vertical wall mounting; leave ≥200 mm ventilation space top and bottom for heat dissipation

  1. Environmental Operation Specifications
  2. Temperatura de funcionamiento: -15℃ ~ +50℃ (derate output by 5% at 50℃)
  3. Almacenamiento / temperatura de transporte: -40℃ ~ +70℃
  4. Clase de protección: Base IP21; upgrade to IP55 with +B056 option
  5. Altitud: Full power up to 1000 metro; derate 1% per additional 100 m arriba 1000 metro
  6. Humedad: 5~95% RH, sin condensación, sin gas corrosivo
  7. Estándar incorporado & Accesorios opcionales

Factory Standard Built-in Components

Detachable Chinese assistant control panel

Integrated DC choke

Basic I/O control board, Modbus RTU

Bottom cooling fan

Optional Expansion Parts

  1. Braking resistor / unidad de frenado: Mandatory for high-inertia start-stop and overhauling loads
  2. Communication adapters: Profibus DP, Profinet IO, Ethernet/IP
  3. EMC filters: Clase A / Clase B, compliant with industrial EMC standards
  4. External 24 V power supply module, remote panel extension cable
  5. Complete IP55 cabinet kit (model suffix +B056)

VII. Escenarios de aplicación típicos

  1. climatización & Tratamiento de agua (Light Load 132 kilovatios)

Cooling fans, tunnel exhaust fans, constant-pressure water supply main pumps, sewage agitators, cooling towers; variable-torque energy-saving operation.

  1. Manejo de materiales & Materiales de construcción (Heavy Load 110 kW Class)

Cintas transportadoras, elevadores de cangilones, cement mixers, extrusoras, centrífugas; frequent start-stop and shock loads.

  1. Maquinaria general

Compresores grandes, wire drawing machines, mixing mills, líneas de producción de papel; precise speed regulation + multi-speed logic.

  1. Minería & Ports

Belt transfer equipment, dust removal fans; ideal IP55 model for wide voltage tolerance and strong dust resistance.

VIII. Adjacent Power Model Comparison within the Same Series

ModeloCorriente nominalStandard PowerHeavy Load Power
ACS580-01-206A-4206 A110 kilovatios90 kilovatios
ACS580-01-246A-4246 A132 kilovatios110 kilovatios
ACS580-01-293A-4293 A160 kilovatios132 kilovatios
  1. Core Product Advantages
  2. Fully integrated functions: Built-in choke, Modbus, multi-channel I/O; ready for complete set without extra options
  3. Chinese assistant panel: Guided commissioning wizard, one-click motor identification
  4. Wide grid compatibility: Universal 380~480 V, compatible with domestic 380 V and overseas 400/440 V grids
  5. Dual control modes: Simple V/F control + vector sin sensores, suitable for both fan and heavy-duty equipment
  6. Optional IP55 high protection; direct wall mounting outdoors or in humid workshops without separate control cabinet
  7. Comprehensive energy-saving algorithms: Sleep mode, flow optimization, soft start-stop, cutting fan and pump energy consumption by over 30%
  8. Compatible with mainstream industrial buses, seamlessly connected to PLC systems such as Siemens, mitsubishi, Innovación
  9. Key Installation & Especificaciones de cableado
  10. Cableado del circuito principal

Aporte: L1/L2/L3 connected to 3-phase 380 V; Output U/V/W connected to 3-phase asynchronous motor; PE earth terminal reliably connected to cabinet ground.

  1. Control Cable Requirements

Route shielded analog signal cables separately with a minimum spacing of 30 cm from power cables; single-end shielding grounding for digital twisted-pair cables.

  1. Mandatory Heat Dissipation Rules

Vertical mounting for R8 frame; top ventilation gap ≥200 mm, side gaps ≥50 mm; blow filter screens monthly in dusty environments.

  1. Braking Selection Reminder

Braking resistors must be fitted for high inertia shutdown and overhauling loads, otherwise frequent DC overvoltage faults will occur.

  1. Quick Troubleshooting Checklist
  2. Overcurrent OL: Motor stall, cortocircuito de salida, cable earth breakdown, insufficient derating for heavy loads
  3. Overvoltage OV: No braking resistor fitted for inertial loads, transient grid high voltage
  4. Overtemperature OT: Blocked air ducts, ambient temperature over 50℃, faulty cooling fan
  5. Pérdida de fase de salida: Loose motor wiring, broken wire on U/V/W one phase
  6. Communication Loss: Mala conexión a tierra del blindaje, missing bus terminating resistor

All Control Modes of ABB ACS580-01-246A-4

All ACS580 drives share one unified control core with no functional cuts for the 246 A (R8 frame) modelo. Three major control categories are supported: Scalar V/F, Sensorless Vector, Vector with Encoder, subdivided into 5 operation modes to cover fans/pumps, general heavy loads and high-precision positioning applications.

  1. Scalar V/F Control (Parámetro 99.04 = SCALAR)
  2. Linear V/F (Default for Light Load Fans & Zapatillas)

Voltage rises linearly with frequency with uniform voltage boost from 0~50 Hz. Suitable for fans, sopladores, pumps and general centrifugal loads.

Características: Simple structure, multi-motor parallel drive (one VFD driving multiple asynchronous motors); weak low-speed torque, zero torque at 0 Hz.

Aplicaciones: sistemas de climatización, constant-pressure water supply, multi-pump parallel systems.

  1. Quadratic V/F (Square Curve, Dedicated for Fans & Zapatillas)

Voltage increases proportional to the square of frequency, matching the torque characteristic of fans and pumps for optimal energy efficiency.

Características: Greatly reduces motor excitation loss and reactive power under light load; even weaker low-speed torque.

Typical scenarios: Cooling tower fans, circulation pumps, dust extraction blowers.

  1. Boostable Torque V/F (Voltage Boost V/F)

Raises output voltage at low frequencies to compensate insufficient low-speed torque.

Aplicaciones: Cintas transportadoras, equipo de mezcla, light starting resistance loads.

  1. Sensorless Flux Vector Control (Parámetro 99.04 = SENSORLESS)

The primary general heavy-load control of ACS580; no encoder required, standard for this 246 A model with no extra options needed.

Core Performance

  1. 100% rated torque output at 0.5 Hz; high starting torque to overcome static friction
  2. Torque response <10 ms, far superior dynamic speed regulation over V/F control
  3. Supports precise current limiting, anti-stall protection and continuous heavy-load operation
  4. Static & rotating motor identification supported, compatible with new and old motors

Cargas aplicables

Transportadores, mezcladores, extrusoras, compresores, maquinaria para trabajar la madera, single heavy-duty motor drives.

Limitaciones

Cannot maintain full torque at zero speed (0 Hz); precise closed-loop speed control unavailable without encoder feedback.

III. Vector Control with Encoder (Parámetro 99.04 = ENCODER)

Requires optional FEN-01 / FEN-11 encoder interface module installed in the VFD expansion slot.

  1. Supports pulse encoders: HTL / TTL incremental encoders
  2. Closed-loop speed control with 100% continuous rated torque at 0 Hz
  3. Speed control accuracy ±0.01% of rated speed
  4. Enables simple positioning, jog operation and tension control

Aplicaciones

Wire drawing machines, winding/unwinding equipment, high-precision transmission, machinery requiring zero-speed load holding.

  1. Two Operation Reference Modes (Speed Command Source, Independent of Above Motor Control Algorithms)
  2. Local Control (Panel Reference)

Frequency set via control panel knob / botones; local start-stop and speed adjustment for single-unit commissioning.

  1. Mando a distancia (External Reference, Mainstream for Engineering)

Speed commands and start-stop signals come from external channels with flexible combinations:

  1. Analog reference: AI1/AI2 (0–10 V / 4–20 mA)
  2. Multi-speed DI digital terminal reference: Arriba a 7 fixed preset speeds
  3. Pulse frequency reference (optional IO module required)
  4. Fieldbus reference: Modbus RTU (estándar), Profibus DP, Profinet, Ethernet/IP, etc..
  5. PID closed-loop reference: Built-in process PID for closed-loop constant control of pressure/flow/temperature (core function for constant-pressure pump & fan water supply)
  6. Special Process Control Modes (Built-in Functions Based on Vector / V/F Core)
  7. PID Process Control

Independent onboard PID regulator; no external PLC required for automatic constant pressure and flow control of pressure, liquid level and temperature.

  1. Multi-pump Cycling Soft Start (HVAC Special Function)

One-drive-multiple circulating water supply, automatic alternation of main and auxiliary pumps, energy saving via sleep & wake-up logic.

  1. JOG Jogging Control

Low-speed jog triggered via DI terminals for equipment maintenance and commissioning.

  1. DC Pre-excitation

DC pre-magnetization before startup to boost instantaneous starting torque in vector mode.

  1. Stall / Anti-overcurrent Torque Limiting

Automatic torque limitation to avoid overcurrent faults under heavy load.

  1. Selección rápida & Distinction Table
Tipo de controlEncoder RequiredLow-speed TorqueUso típico
Quadratic V/FNoBajoEnergy-saving control for fans & zapatillas
Linear V/FNoModeradoMulti-motor parallel driving
Sensorless VectorNoAlto (Full torque at 0.5 Hz)Transportadores, mezcladores, general heavy loads
Vector with EncoderFEN Module RequiredUltra alto (Zero-speed torque holding)Winding equipment, high-precision transmission & posicionamiento

Applicable Scenarios of Closed-Loop Vector Control with Encoder for ABB ACS580-01-246A-4

Preface

This control mode uses parameter code 99.04=ENCODER. Optional FEN-01 (HTL) / FEN-11 (TTL) incremental encoder modules are mandatory. Real-time speed feedback from the motor shaft encoder delivers three core advantages:

  1. Continuo 100% rated torque holding at 0 Hz (sensorless vector cannot hold load at zero speed)
  2. Speed control accuracy ±0.01% rated speed with no low-speed jitter or step loss
  3. Supports precise tension closed-loop control, sincronización multieje, simple positioning and constant-torque processes

Closed-loop vector control is only selected for working conditions requiring zero-speed load holding, high low-speed precision, tensión estable, multi-axis synchronization and slip-free heavy start-stop. Standard fans, pumps and single ordinary conveyors can operate reliably with sensorless vector or V/F control only.

  1. Winding & Unwinding Industry (Most Typical High-power Application, Pareo 132 kW Class 246 un modelo)

Equipo aplicable

Paper rewinders, plastic film extrusion winders, rubber calender winding/unwinding machines, non-woven slitting machines, metal foil wire drawing & maquinas bobinadoras, cable stranding machines

Mandatory Process Requirements for Closed-Loop Vector

  1. Smooth low-speed startup and constant tension maintenance during shutdown; no loose rolls, stretching or material breakage at zero speed
  2. Automatic constant tension as roll diameter dynamically changes between large and small reels, speed follows upstream master machine
  3. No tension fluctuation during high-low speed switching to prevent wrinkling or stretching deformation of web materials
  4. Multi-section linkage: Synchronized operation of unwinding-traction-winding three axes

Open-loop Disadvantages: Insufficient low-speed torque without encoder leads to web slipping and out-of-control tension.

  1. High-precision Positioning / Intermittent Reciprocating Heavy-duty Equipment

Equipo aplicable

Large gantry feeders, heavy plate translation positioning tables, stone cutting feeders, cement block stacking conveyors, large packaging reciprocating cross-cutting machines

Process Requirements

  1. Precise stop at target positions with minimal repetitive positioning error; frequent jog & inching maintenance operations
  2. No position shifting or slipping when stationary under full load
  3. No speed overshoot during acceleration & desaceleración; no jitter or impact on heavy start-stop

III. High-inertia Overhauling / Vertical Lifting Constant-torque Loads (High-power 110/132 kW Heavy-duty Conditions)

Equipo aplicable

Downward mine belt conveyors, large bucket elevators, heavy vertical mixers, lifting silo discharge drives

Process Pain Points Unsolvable by Open-loop Control

Reverse load generated by material self-weight requires full torque braking maintained at zero shutdown speed; overhaul runaway and overvoltage alarms easily occur at low descending speeds. Encoder closed-loop corrects speed in real time to suppress regenerative impact and stabilize DC bus voltage with braking units.

  1. Multi-motor Synchronized Production Lines (Long-distance High-power Synchronous Transmission)

Equipo aplicable

Cement kiln chain conveyors, long-distance multi-drive mine belts, multi-layer drying synchronized roller tables, continuous metal pickling lines

Process Requirements

Rigid synchronization of multiple motors with minimal speed deviation across sections to avoid plate stretching, belt deviation and tearing. Closed-loop vector with encoder feedback achieves far superior multi-motor synchronization accuracy compared to open-loop sensorless vector.

  1. Heavy-duty Equipment for Extrusion, Kneading & High-viscosity Mixing

Equipo aplicable

Plastic single/twin-screw extruders, rubber internal mixers, chemical high-viscosity reactor agitators, main asphalt mixing machines

Process Requirements

  1. Extremely high starting resistance for low-temperature high-viscosity materials; full torque output at 0 Hz to avoid startup stalling
  2. Constant extrusion torque throughout operation for uniform output thickness
  3. No torque ripple under steady low-speed operation for consistent product thickness
  4. Centrifuges & High-speed Precision Rotating Equipment

Equipo aplicable

Large chemical separation centrifuges, high-speed paper dehydration centrifuges, large horizontal food centrifuges

Process Requirements

High-precision stable speed across wide speed ranges with minimal speed fluctuation during acceleration/deceleration. Real-time speed correction via encoder feedback at high operating speeds eliminates resonance and uneven material stratification.

VII. High-power Stenter, Configuración & Padder Equipment for Textile Printing & Dyeing

Equipo aplicable

High-power stenters, water squeezing & calendering machines, continuous dyeing long lines

Process Requirements

Synchronized drafting of multiple rollers without fabric stretching or shrinkage; zero-speed load holding during low-speed fabric threading to avoid fabric accumulation and slipping; stable tension throughout operation.

VIII. Scenarios Unsuitable for Closed-Loop Vector Control (Select V/F or Sensorless Vector Directly)

  1. aficionados, cooling towers, circulation pumps, dust extraction blowers (variable-torque loads with no zero-speed load holding demand)
  2. Single light-duty belt conveyors, small mixers, compresores (no high-precision synchronization or tension control requirements)
  3. One-drive-multiple parallel multi-motor systems (only scalar V/F control applicable; encoder closed-loop cannot support multi-motor parallel driving)

Quick Application Selection Reference Table

Core Working Condition RequirementRecommended Control ModeCodificador (FEN Module) Requerido
aficionados, zapatillas, multi-motor parallel drivingScalar V/FNo
Ordinary conveyors, mezcladores, compresoresSensorless VectorNo
Winding/unwinding, control de tensión, zero-speed load holdingClosed-loop Vector with EncoderFEN-01/FEN-11 Required
Sincronización multieje, precision positioning, high-inertia overhauling loadsClosed-loop Vector with EncoderFEN Module Required
High-viscosity extrusion, kneading, high-power centrifugesClosed-loop Vector with EncoderFEN Module Required

Supplementary Supporting Hardware (ACS580-01-246A-4 R8 Frame)

  1. HTL incremental encoder: Select FEN-01
  2. TTL differential encoder: Select FEN-11
  3. Braking resistors / braking units must be fitted for high-inertia overhauling scenarios to eliminate regenerative overvoltage faults