Delta EOE-12010005-DRP024V240W-1AA Industrial Power Supply

Model Code Explanation Code Segment Description EOE-12010005 Delta internal part number / order number for inventory and order management DRP Product series code: CliQ series DIN Rail Power Supply 024V Output voltage: 24VDC 240W Rated output power: 240 Watts 1AA Specification version code: 1 = 1st generation; AA = standard configuration with Class I Div ...

  • Detalles del producto

Explicación del código del modelo

Segmento de códigoDescripción
EOE-12010005Delta internal part number / order number for inventory and order management
DRPCódigo de serie del producto: CliQ series DIN Rail Power Supply
024Vvoltaje de salida: 24VCC
240W.Rated output power: 240 Watts
1Automóvil club británicoSpecification version code: 1 = 1st generation; AA = standard configuration with Class I Div 2 proceso de dar un título
  1. Especificaciones técnicas principales
CategoríaEspecificaciones detalladas
Tipo básicoDIN rail mounted switching power supply, AC-DC conversion, single output
Características de entradaWide input voltage: 85-264VACACIONES, Frecuencia: 47-63Hz, Power Factor ≥ 0.95
Características de salida24VCC, Rated current 10A, Rated power 240W, Voltage tolerance ±1%
Ripple & Ruido≤ 120mVp-p (Full load)
Funciones de protecciónProtección contra sobretensión (28.5-31.5VCC), Protección contra sobrecorriente (11-13A), Protección contra sobrecalentamiento (85℃±5℃), Protección contra cortocircuitos (auto-recovery)
Hold-up Time≥ 20ms (Full load, 230VAC input)
EficienciaArriba a 89% (Full load)
Entorno operativoTemperatura: -20℃ ~ +75℃ (Derating required above 50℃); Humedad: 10~95%RH (Sin condensación)
Protección de ingresoIP54 (Dust and water resistant)
Tipo de montaje35mm montaje en carril DIN (Compliant with EN60715)
Dimensiones118.5mm × 85mm × 57.5mm (L × W × H)
PesoAprox.. 450gramo
CertificacionesCE, UL, Class I Div 2, Cumple con RoHS
Indicación de estadoPower LED indicator (Green = Normal, Off = Fault)
  1. Cross-brand Equivalent Comparison
MarcaModelo equivalentePrincipales diferencias
Electricidad SchneiderABL8REM24045HDelta DRP series has higher efficiency (89% vs 87%) and better IP54 protection; Schneider offers more competitive price
siemensSITOP PSU100C 24V/10ADelta features more compact size and Class I Div 2 certification for hazardous areas; Siemens provides longer warranty (3 years vs 2 años)
OmrónS8VK-C24024Delta has longer hold-up time (20ms vs 16ms) and superior derating performance; Omron delivers better EMI/EMC performance
Mean WellDR-240-24Delta has higher IP rating (IP54 vs IP30) and Class I Div 2 proceso de dar un título; Mean Well is lower-priced with larger market share
Delta Replacement ModelDRP-24V240W1CBN (CliQ III Series)EOE-12010005-DRP024V240W-1AA is discontinued. CliQ III series achieves 91% efficiency, fully compatible with improved performance
  1. Full Model List of CliQ DRP Series
ModeloVoltaje de salidaPotencia de salidaCorriente de salidaCaracterísticas especialesEstado
DRP024V060W1AA24VCC60W.2.5ATipo estándar, Class I Div 2Interrumpido, replaced by DRP-24V060W1CBN
DRP024V120W1AA24VCC120W.5ATipo estándar, Class I Div 2Interrumpido, replaced by DRP-24V120W1CBN
DRP024V240W1AA24VCC240W.10ATipo estándar, Class I Div 2Interrumpido, replaced by DRP-24V240W1CBN
DRP012V120W1AA12VCC120W.10A12salida V, Class I Div 2Interrumpido, replaced by DRP-12V120W1CBN
DRP024V240W1AB24VCC240W.10AEnhanced type with DC OK signalInterrumpido, replaced by DRP-24V240W1CBN
DRP-24V240W1CBN24VCC240W.10ACliQ III series, 91% efficiencyIn production
DRP-24V240W1CAN24VCC240W.10ACliQ III series with redundancy functionIn production
  1. Fallos comunes & Solución de problemas
Fenómeno de fallaPosibles causasPasos para solucionar problemas
Power LED off, no outputAbnormal input voltage, damaged power cable, blown fuse, faulty power unit1. Verify input voltage within 85-264VAC
2. Check cable connection and terminals
3. Test continuity of fuse (si está equipado)
4. Replace power supply for test
Low output voltageSobrecarga, low input voltage, aged capacitor, faulty feedback circuit1. Confirm load does not exceed 240W rated power
2. Ensure input voltage ≥ 85VAC
3. Inspect output capacitors for bulging or leakage
4. Check resistance drift of feedback resistors
Excessive rippleAged output capacitor, defective rectifier diode, unstable load1. Measure ripple with oscilloscope (máx.. 120mVp-p)
2. Replace output filter capacitors
3. Test forward voltage of rectifier diodes
4. Ensure stable resistive load
Overtemperature protection activatedTemperatura ambiente alta, poor ventilation, faulty fan (si está equipado), sobrecarga1. Check ambient temperature does not exceed 50℃
2. Improve ventilation condition
3. Check fan operation (si está equipado)
4. Reduce load below 80% of rated power
Frequent short circuit protectionCortocircuito de salida, internal load short circuit, defective power unit1. Disconnect load and measure output resistance (>100Ω required)
2. Locate short circuit inside load equipment
3. Replace load for test
4. Replace power supply for test
  1. Entornos de aplicación & Casos de la industria

Escenarios aplicables

  1. Automatización Industrial: Power supply for PLCs, sensores, servo drives and HMIs; Class I Div 2 certified for hazardous areas
  2. Control de procesos: Power for valve actuators, flow meters and analytical instruments; ±1% voltage accuracy ensures measurement precision
  3. Industria petroquímica: Class I Div 2 certification for Zone 2 áreas peligrosas; IP54 protection suitable for outdoor and humid environments
  4. Alimento & Bebida: Power for production line automation equipment; wide temperature range adapts to cold storage and high-temperature areas
  5. Automatización de edificios: Power for access control, monitoring devices and HVAC systems; DIN rail installation saves cabinet space

Escenarios no recomendados

  1. Equipo médico: Without medical certifications (BF/CF level), not applicable for devices in direct contact with human body
  2. High-pressure Washing Areas: No IP65 or higher protection, not suitable for high-pressure flushing
  3. High-frequency Pulse Loads: Not for loads over 100Hz with duty cycle > 50%, which may cause unstable output
  4. High-altitude Areas: Derating required above 2000m; Not recommended for altitude over 5000m

Casos de aplicación típicos

Caso 1: Petrochemical Pipeline Control System

Equipo: Danfoss 027H9075 (ICAD 600A) electric actuator, pressure sensors, SOCIEDAD ANÓNIMA, safety barriers

Funciones: Automatically adjust valve opening according to pipeline pressure; realize remote monitoring and emergency shutdown

Highlights: Class I Div 2 certification adapts to hazardous areas; IP54 protection withstands outdoor humidity; 24V/10A output supports multiple actuators simultaneously; wide input voltage tolerates grid fluctuation in remote areas

Caso 2: Automatic Packaging Production Line

Equipo: Fatek FBs-40MCR2-AC PLC, servo motors, photoelectric sensors, pneumatic actuators

Funciones: Product counting, fixed-length cutting of packaging film, labeling position control and fault alarm

Highlights: DIN rail installation saves control cabinet space; 89% high efficiency reduces power consumption; overvoltage/overcurrent/overtemperature protection ensures system safety; 20ms hold-up time prevents program loss from momentary power failure

  1. Consejos de selección & Reglas de referencia rápida

Consejos de selección

Match power rating with load demand, ensure stable output voltage and accuracy, select protection class per operating environment, complete certifications for safety, and adopt DIN rail mounting to save space.

Reglas de referencia rápida

DRP: Delta CliQ series DIN rail power supply, IP54 protection, Class I Div 2 certificado

024V/240W/1AA: 24salida V, 240W power, 1st generation standard version

Wide input: 85-264VACACIONES, global compatibility and strong grid fluctuation resistance

Alta eficiencia: 89%, energy saving and lower heat generation

Modelo de reemplazo: DRP-24V240W1CBN (CliQ III series) with efficiency upgraded to 91%

Matching Modules & Accessories for Delta EOE-12010005-DRP024V240W-1AA

  1. Core Power Management Modules (Exclusive for CliQ Series)
Tipo de móduloModeloMain FunctionEscenarios de aplicación
Módulo de redundanciaDRR-20A (24V/20A)1+1 or N+1 redundant parallel connection, automatic switchover upon fault to improve system reliabilityPower supply for critical equipment (SOCIEDAD ANÓNIMA, safety systems) and non-stop operation systems
Módulo de redundanciaDRR-20N (24V/20A)With reverse polarity protection, supports multi-power parallel and current sharingIndustrial control systems requiring current expansion and redundant backup
Buffer ModuleDRB-24V020ABA (24V/20A)Provides temporary power (100ms~3s) after power cut to avoid data lossPrevent PLC program loss and sensor signal abnormality caused by momentary power failure
DC-UPS ModuleDRC-24V010A (24V/10A)Connect external batteries for long-duration backup power, soporte de intercambio en calienteImportant control systems requiring power supply for several minutes to hours during outage
Monitoring ModuleDRM-24V010 (24V)Real-time monitoring of output voltage, current and temperature with fault alarmRemote status monitoring and early fault warning, ideal for unattended control rooms
  1. Instalación & Accesorios de cableado
Tipo de accesorioModeloPresupuestoDescripción de la función
Carril DINDRS-35 (Estándar)35mm de ancho, compliant with EN60715Mount power supplies and modules to save cabinet space
Bloque de terminalesDRT-24V10P (24V/10A)10-position terminal block, screw type, tinned copperPower distribution for multiple loads
Bloque de terminalesDRT-24V20P (24V/20A)20-position terminal block, high-current designConnection for multiple actuators, motors and other high-current loads
Power ConnectorDRC-024V-M12 (M12)5-clavija conector M12, IP67Power connection for outdoor and humid environments
Soporte de montajeDRS-01 (Universal)Metal material, compatible with DRP seriesEnhance installation stability and prevent loosening from vibration
Cubierta protectoraDRC-01 (Protective type)Plastic material, IP54Protect wiring terminals against dust and water splash
  1. Matched Application Equipment (Typical Industrial Scenarios)

3.1 Core Automation Control Equipment

Tipo de equipoModelo recomendadoCompatibility ReasonApplication Case
PLC Main UnitFatek FBs-40MCR2-AC24VDC input, 16 salidas de relé, fully compatible with 24V DRP power supplyPackaging line control, product counting and labeling positioning
PLC Main UnitDelta DVP-SA2-40MRNative Delta product with high compatibility, 24VDC poweredFood processing equipment, temperature and pressure regulation
HMIDelta DOP-107BV7-inch touch screen, 24Fuente de alimentación VCC, Protección IP65Real-time system monitoring, parameter setting and fault alarm
ServoaccionamientoDelta ASD-B2-0421-B24VDC control power, fast response matching DRP power supplyHigh-precision motion control for automated production lines

3.2 Control de procesos & Actuating Equipment

Tipo de equipoModelo recomendadoCompatibility ReasonApplication Case
Electric ActuatorDanfoss 027H9075 (ICAD 600A)24VDC power, 1.2A operating current, matches 24V/10A outputPetrochemical pipeline valve control and remote opening regulation
Válvula SolenoideAirtac 4V210-0824VDC coil, low power consumption for mass controlPneumatic system control for cylinder movement and valve switching
SensorOmron E2E-X10D1-N24VDC powered inductive proximity sensor, Protección IP67Object detection, positioning and production line counting
Isolator BarrierPepperl+Fuchs KFD2-SR2-EX1.W24VDC power, signal isolation for hazardous areasSignal isolation and safety protection in petrochemical hazardous locations
  1. Selection Guide for Matching Modules

4.1 Redundancy Configuration

1+1 Redundancia: 2 pcs DRP024V240W1AA + 1 pc DRR-20A

Corriente de salida: 20A, Output power: 480W.

Solicitud: Critical control systems with zero downtime requirement

N+1 Redundancy: N pcs DRP024V240W1AA + 1 pc DRR-20N

Corriente de salida: 10A × N, Output power: 240W × N

Solicitud: Large automation systems requiring power expansion and redundant backup

4.2 Power Backup Solutions

Backup RequirementMódulo recomendadoBattery ConfigurationBackup Duration
Short-term (1-3s)DRB-24V020ABA Buffer ModuleNo external battery required100ms ~ 3s (Depends on load)
Medium-term (5-30mín.)DRC-24V010A DC-UPS Module2 pcs 12V/7Ah batteries (series connection)5 ~ 30 minutos (Depends on load)
Long-term (1-8h)DRC-24V010A + Battery Extension Box2 pcs 12V/17Ah batteries (series connection)1 ~ 8 horas (Depends on load)

4.3 Monitoring Solutions

Monitoreo Básico: DRM-24V010 Monitoring Module + Delta DOP-107BV HMI

Real-time display of voltage, current and temperature with fault alarm

Monitoreo remoto: DRM-24V010 + Delta DVP-PLC + Ethernet Module

Remote power status monitoring, historical data recording and analysis via network

  1. Quick Reference Rules for Matching Equipment
  2. Módulo de redundancia: Model starts with DRR; 20A/40A indicates current rating, compatible with DRP series
  3. Buffer Module: Model starts with DRB; provides millisecond-level power backup without batteries
  4. DC-UPS Module: Model starts with DRC; connects external batteries for long-duration power backup
  5. Monitoring Module: Model starts with DRM; real-time status detection and fault alarm
  6. Cargas típicas: SOCIEDAD ANÓNIMA, HMI, servo drives, sensors and actuators are all 24VDC powered, matching the 10A output of DRP024V240W1AA

Anterior: