Inversor Fuji FRN0018G2S4C

Model Code Explanation FRN: Fuji inverter series 0018: Código de capacidad; Heavyduty HHD: 5.5 kilovatios, Lightduty HND: 7.5 kW G2S: FRENICMEGA G2S series (successor model of G1S) 4: 3phase 380480 V C: Chinaspecific version, builtin EMC filter Core Electrical Specifications Item Specification Input 3‑phase 380‑480 V, 50/60 Hz Rated Output Current 13.5 A Heavy‑duty HHD 5.5 kW, 150%‑1 min, 200%‑3 s Light‑duty HND 7.5 kW, 120%‑1 min ...

  • Detalles del producto

Explicación del código del modelo

FRN: fuji inversor serie

0018: Código de capacidad; Heavyduty HHD: 5.5 kilovatios, Lightduty HND: 7.5 kilovatios

G2S: FRENICMEGA G2S series (successor model of G1S)

4: 3phase 380480 V

do: Chinaspecific version, filtro EMC incorporado

Especificaciones eléctricas básicas

ArtículoEspecificación
Aporte3‑phase 380‑480 V, 50/60 Hz
Corriente de salida nominal13.5 A
Heavy‑duty HHD5.5 kilovatios, 150%‑1 min, 200%‑3 s
Light‑duty HND7.5 kilovatios, 120%‑1 min
Modos de controlV/F, Vector sin sensores, Simple Positioning, Orientation Function
Frecuencia de salida0‑599 Hz
Standard FeaturesBuilt‑in braking transistor; RS485; STO Safe‑Torque‑Off
Dimensiones (Ancho×Alto×Profundidad)220 × 260 × 195 mm
EnfriamientoFan cooling

Funciones principales

  1. Control vectorial sin sensores, 200% starting torque at 0.3 Hz, good adaptability for shockloaded applications
  2. PID autotuning, 260step custom logic, multispeed, posicionamiento sencillo & orientation
  3. Optional communication cards: PD, Modbus, Ethernet/IP, etc..
  4. Servicelife diagnosis, fault history traceback, parameter upload/download via keypad or software
  5. Compatible with induction motors and synchronous motors

Aplicaciones típicas

Transportadores, maquinaria de embalaje, fans & zapatillas, maquinas herramientas, extrusion equipment, generalpurpose process drives.

Referencias de reemplazo

  1. Sameseries alternative: FRN0018G24J (Overseas version, no builtin EMC filter)
  2. Alternativas domésticas: Inovance MD380T5.5GB/7.5PB; INVT GD3505R5G4

⚠️Replacement note: Terminal definitions, functioncode mapping and communication protocols are not fully compatible. Motor autotuning must be reperformed.

Secondhand Unit Inspection Checklist

  1. Verify 3phase output current balance; no phase loss or current unbalance
  2. Inspect fan and electrolytic capacitors for bulging or electrolyte leakage
  3. Run motor static autotuning to confirm normal vectorcontrol performance
  4. Check fault history and clear old alarms

Important Clarification

There is no Mitsubishi FRN0018G2S4C model.

FRN0018G2S4C is a Fuji Electric FRENICMEGA G2S inverter. Mitsubishi inverters use the prefix FR, p.ej. FRD740, FRA840. Mitsubishi has no FRNprefixed models. It is a common industry misnomer to call Fuji FRNseries units “Mitsubishi”.

Full Information for Fuji FRN0018G2S4C

Modelo: FRN0018G2S4C

Marca: Electricidad Fuji (manufactured in Wuxi, Porcelana)

Voltaje: 3phase 380480 V

HHD Heavyduty: 5.5 kilovatios; HND Lightduty: 7.5 kilovatios; Corriente de salida:13.5 A

Sufijo 4: 400 clase V; S: Modelo estándar; do: Chinamarket version with builtin EMC filter

Serie: FRENICMEGA G2S (G1S upgrade, equipped with STO, vector sin sensores, posicionamiento sencillo)

Frequently Confused: Mitsubishi Peerrating Reference

If you intend to compare with Mitsubishi equivalentpower inverter, the counterpart is FRA8400170460 (5.5 kW heavyduty). Comparison table below:

ArtículoFuji FRN0018G2S‑4CMitsubishi FR‑A840‑0170‑4‑60
Prefijo de modeloFRN (fuji)FR‑ (mitsubishi)
ControlVector sin sensores, 200% torque @0.3 HzAdvanced magnetic‑flux vector
Standard HardwareSTO, built‑in braking transistor, RS485, filtro EMC incorporadoSTO; braking transistor depends on version; EMC filter mostly optional
FuncionesSimple positioning/orientation, 260‑step custom logicPLC incorporado, sequence logic
ComunicaciónRS485; optional DP / EtherNet/IP cardsRS485, Enlace CC, optional Ethernet card
Parameter SystemFuji function‑code systemMitsubishi parameter‑number system; zero compatibility

Onsite Identification Tips

  1. Nameplate marking: Fuji displays FRENICMEGA; Mitsubishi displays Mitsubishi Electric
  2. Model rule: FRN = Fuji; FR= Mitsubishi. Wrong ordering prefix will result in wrong delivery.
  3. Keypad layout: G2S keypad layout differs completely from Mitsubishi A840 series.

Replacement Reminder

Direct dropin swap from Fuji G2S to Mitsubishi A840 is impossible. Terminales, parameters and motortuning logic differ; full recommissioning is required.

Application Fields of Fuji FRN0018G2S4C (FRENICMEGA G2S)

Unit features: HHD Heavyduty 5.5 kW, HND Lightduty 7.5 kW, sensorlessvector control, 200% starting torque @0.3 Hz, builtin braking transistor, STO SafeTorqueOff, simple positioning/orientation, PID autotuning. Suffix4C is Chinaversion with builtin EMC filter, optimized for shockload and constanttorque process drives.

  1. Materialhandling & Logística (Constanttorque, shockprone loads)

Cinturón / roller / chain conveyors, transportadores de tornillo

Apiladores, AS/RS transfer mechanisms, líneas de clasificación

Material hoists, unloading equipment

Fit reasons: Shockload tolerance, high lowspeed torque, multispeed capability, RS485 networking support, builtin braking transistor for emergencystop conditions.

  1. Embalaje & Foodprocessing Machinery

Máquinas de embalaje, selladores, case packers, etiquetadoras

Food mixers, slicers, grainprocessing equipment

Processingline material handling

Fit reasons: 260step onboard custom logic may replace smallsize PLC; PID regulation for stable speed; builtin EMC filter reduces field electromagnetic interference.

  1. Plástica & Rubber Extrusion

Pequeñas extrusoras, comederos, traction rolls, unwinder/winder equipment

Fit reasons: Stable sensorlessvector speed regulation, good antidisturbance under load fluctuation; supports both induction and synchronous motors; suitable for constanttension traction in extrusion lines.

  1. Machinetool & Maquinaria para trabajar la madera

Auxiliary machinetool axes, rotary worktables, woodplaners, cortadores

Highspeed smallspindle drives up to 599 Hz output frequency

Fit reasons: Highresponse vector control, simple positioning/orientation for angularstop applications; STO fulfills machinetool safety requirements.

  1. climatización, Watersupply, aficionados & Zapatillas (HND Lightduty 7.5 kW)

Constantpressure watersupply pumps, circulating pumps, coolingtower fans, boiler fans, sistemas de climatización

Fit reasons: PID autotuning, energysaving automatic operation. ⚠️Note: G2S is highperformance generalpurpose drive. For largevolume fanpump projects Fuji F2S series is more costeffective.

  1. Textil, Papermaking & Cable Equipment

Spinning & knitting machinery; small winders & rebobinadoras

Papermaking auxiliary drives, coatingprocess rolls

Fit reasons: Sufficient lowspeed torque, respuesta rápida, stable speed under varying loads; supports optional communication cards for networked control.

  1. Químico & Buildingmaterial Generalprocess Equipment

Agitadores, reactor stirrers, centrífugas, compresores pequeños

Buildingmaterial productionline conveyors, grinding equipment

Fit reasons: Strong overload capability:150%1 min /200%3 s; servicelife diagnosis and fault history for maintenance troubleshooting.

  1. Other Generalpurpose Equipment

Washing machines, carwash systems, testbenches, various nonstandard automation machines.

Selección & Usage Hints

  1. HHD Heavyduty 5.5 kW: For shockloaded, highstartingresistance equipment (transportadores, extrusoras, maquinas bobinadoras).
  2. HND Lightduty 7.5 kW: For smoothload fans and pumps.
  3. Builtin EMC filter: Wellsuited for Chinese factory environments; reduces interference to nearby sensors.
  4. Simplepositioning function: Can realize basic station positioning without servo drives for cost reduction.

Parameter Setting Procedure for Fuji FRN0018G2S4C (FRENICMEGA G2S)

Keypadbutton description:

PROG/RESET: Enter parameter menu / reinicio de falla

FUNC/DATA: Enter functioncode menu / save parameters

▲ ▼: Scroll functioncodes / modify values

MODO: Toggle monitor screens (frecuencia, actual, Voltaje, registros de fallas)

FWD, REV, DETENER: Keypad forward, contrarrestar, stop commands

  1. Standard Commissioning Sequence (Field Workflow)

Step 1: Factory Reset

  1. Press【PROG/RESET】to enter parameter mode
  2. Locate F00 (Initialization), set value =1
  3. Press【FUNC/DATA】to confirm, powercycle the inverter. All parameters revert to factory defaults.

⚠️Important: Perform reset for new units, motor replacement, or abnormal commissioning status.

Step 2: Input Motornameplate Data (Pgroup motor parameters)

Input exact values from the motor nameplate. Mandatory for vectorcontrol operation.

Function‑codeNombreObservaciones
P01Motor pole numberp.ej. enter 4 for 4‑pole motor
P02Rated motor power(kilovatios)5.5 kW /7.5 kW per motor nameplate
P03Rated motor current(A)Read from motor nameplate; do NOT use inverter rated‑current value
P04Rated motor frequency(Hz)Typically 50 Hz
P05Rated motor voltage(V)Enter 380 for 380 V motor
P06Rated motor speed(rpm)Value from motor nameplate

Step 3: Motor Autotuning (Mandatory for vectorcontrol, to achieve 200% @0.3 Hz torque)

  1. Static autotuning (Fieldfriendly; no mechanical disconnection required)

Set P07=1 (Static autotuning), press【FUNC/DATA】, display shows TUNE

Press【FWD】to start tuning; wait dozens of seconds, process terminates automatically.

  1. Rotational autotuning (Motor must run unloaded; best tuning result)

Set P07=2, press【FWD】. Motor will run at low speed for learning.

Advertencia: For rotational autotuning, motor must be mechanically decoupled to avoid injury risk.

Step 4: Runcommand & Frequencyreference Source Configuration

✅ Keypad control (Keypad start/stop + keypad frequency adjustment)

F02 Runcommand source =0 (Keypad buttons)

F01 Frequencyreference source =0 (Keypad ▲▼ keys)

✅ Terminal control (Fieldmostcommon: externalterminal startstop, analog speed reference)

F02 =1: Terminal runcommand (Short FWD to COM for forward rotation; short REV to COM for reverse rotation)

F01 Frequencyreference source:

1: Terminal 12 (010 V voltage reference)

2: Terminal C1 (420 mA current reference); set mainboard DIPswitch SW8 to C1 position.

✅ RS485 Communication control

F02 =2: Communication runcommand; F01=4: Communication frequency reference.

Step 5: Basic Fgroup Operating Parameters

Function‑codeNombreConfiguración recomendada
F03Maximum output frequency50 Hz (max configurable 599 Hz)
F04Base frequency50 Hz
F05Upper‑limit frequency50 Hz
F06Lower‑limit frequency0 Hz
F07Acceleration time(s)2-10s; increase for shock‑loaded equipment
F08Deceleration time(s)2-10s; install braking resistor for high‑inertia loads
F10Electronic thermal‑protectionSet to motor rated‑current value P03 for motor overload protection

This unit has builtin braking transistor. If OV overvoltage faults occur during deceleration, connect external braking resistor between P(+) and DB terminals.

  1. Quicksetup for Frequentlyused Functions
  2. Multispeed operation (Select preset speeds via Xterminals)
  3. Set E01(X1 terminal)=1(SS1); E02(X2 terminal)=2(SS2)
  4. C05C19: Multispeed frequency 115, configure each presetspeed value.

Combination logic of X1/X2 terminals supports up to 15 velocidades preestablecidas. Multispeed has higher priority than analog reference.

  1. PID Control (Constantpressure watersupply, constanttension applications)
  2. J01=1: Enable PID
  3. J02: Select PID setpoint source
  4. J03J05: P/I/D gain parameters; enable J30 PID autotuning for automatic gain optimization.
  5. STO SafeTorqueOff (Hardware safety circuit)

Terminals TH1TH2: Both terminals must be shortcircuited to enable inverter output. Open STO circuit directly blocks power output without alarm code.

III. Copia de seguridad de parámetros & Upload/Download

Requires TPA2SW operator keypad:

  1. Read parameters from old inverter: Enter menu Y98 to upload parameters to keypad memory.
  2. Write parameters to new inverter: Set Y99 for download; bulkimport all parameters without manual entry.
  3. Controlmode Selection for Different Load Types
  4. Transportadores, extrusoras, polipastos (Heavyduty constanttorque)

F42 Controlmode =1【Sensorless Vector 2】. Complete motor autotuning for high lowspeed torque.

  1. aficionados & zapatillas (Lightduty squarelaw load)

F42 =0: Control V/F. Motor autotuning is unnecessary.

  1. Highspeed spindle applications (Highfrequency output)

Increase F03 maximumoutputfrequency setting, run under V/F mode. Respect motor maximumspeed rating.

  1. Common Commissioningfault Troubleshooting
  2. Sobrecorriente OC: Doublecheck P03 motorcurrent setting; confirm autotuning completion; increase accelerationtime value.
  3. OV Overvoltage: Decelerationtime too short; increase F08 decelerationtime; fit braking resistor for highinertia loads.
  4. Par insuficiente: Verify correctness of Pgroup motorparameters, finish autotuning, activate sensorlessvector mode.
  5. Interferencia electromagnética: 4C model has builtin EMC filter; use shielded motor cables; reliable earthing for inverter and motor.
  6. Practical Operation Notes
  7. After modifying parameters, press FUNC/DATA to save; otherwise settings will be lost after poweroff.
  8. After motor replacement, reenter P01P06 and rerun autotuning.
  9. Toggle HHDHeavyduty / HNDLightduty mode via F44: 0 = HHD Heavyduty 5.5 kW; 1 = HND Lightduty 7.5 kW.