V810iCN-080, manufactured by Japan Fuji HAKKO Electric. 10.4-inch resistive touch-screen HMI, AC powered, Ethernet incorporado, obsolete discontinued model.
-080: Firmware version suffix; hardware base model = V810iCN
1|Model Decoding V810iCN-080
| Segmento | Definición |
| V810 | 10.4‑inch unit |
| i | High‑performance version: On‑board Ethernet LAN port |
| do | TFT‑LCD, VGA 640×480 resolution |
| norte | AC100‑240V AC power supply; no expansion option port |
| ‑080 | Firmware revision number |
⚠️V810iCN: No external option unit port; analog resistive touch screen, 8 physical function keys on panel edge.
2|Core Hardware Specifications
| Artículo | Parámetro |
| Mostrar | 10.4″ LCD TFT en color |
| Resolución | 640×480 VGA |
| Display Colors | 65536 bandera |
| Iluminar desde el fondo | retroiluminación LED |
| Tipo táctil | Analog resistive touch, 1024×1024 |
| Physical Keys | 8 side function switches |
| Fuente de alimentación | AC100‑240V ±10% |
| Consumo de energía | Aprox.. 70Virginia |
| On‑board LAN | RJ45 Ethernet 10/100Mbps |
| Serial Port CN1 | D‑SUB9 RS232C/RS422/485 |
| MJ Port | 8‑Pin modular interface ×2, RS232‑485 |
| USB | USB‑A, USB‑MiniB |
| Memory Card | CF‑card slot |
| Backup Clock | Lithium coin battery |
| Front‑panel Protection | IP65 |
| Temperatura de funcionamiento | 0‑50℃ |
Overall & Cut-out Dimensions
Dimensión general: 303(W.)×231(h)×62(D) milímetros
Panel cut-out: 274 × 204 mm
3|Communication Capabilities
Supports simultaneous communication with up to 8 PLC devices, multi-brand PLC protocols supported; capable of gateway data forwarding.
software de programación: V-SFT (configuration software for V8 series).
Supported functions: Recipe management, registro de alarmas, historical data, CF-card storage, macro script.
4|Lifecycle & Opciones de reemplazo
✅V8 series is discontinued. V810iCN-080 is an end-of-life spare part, only second-hand / refurbished stock available.
OEM Upgrade Replacement (Fuji HAKKO V9 series)
- V9100iS-080 (10.4-pulgada, VGA, alimentación de CA, cut-out compatible, project conversion required within V-SFT)
Nota: V8 project files cannot be directly downloaded to V9 hardware; project migration via software conversion is mandatory.
Reemplazos nacionales compatibles (Cut-out reference)
Weinview MT8102iP; Inovance IT7100; FLEXEM FE6100C; MCGS TPC1061Ti.
⚠️Cut-out dimension 274×204 mm: Most standard 10-inch HMIs on market have different cut-out sizes, Es posible que se requiera una modificación del gabinete..
5|Second-hand Spare-part Inspection Checklist
- Power-on test: Check backlight for yellowing or flickering; backlight degradation is a common failure.
- Touch verification: Full-screen touch test, no drift or dead zones.
- Battery inspection: Built-in coin-cell battery; flat battery causes loss of clock and SRAM recipe data.
- Full-interface test: Puerto Ethernet, two MJ serial ports, D-SUB9 serial port, USB read-write functionality.
- CF-card slot read-write test.
- Read firmware version to confirm-080 revision.
6|Common Faults
- Touch failure: Damaged touch panel; touch glass can be replaced independently.
- Black screen at power-up: Power-board fault or LED backlight damage.
- Time reset: Depleted backup lithium coin battery.
- CF-card read-write failure: Poor contact of card slot.
- Comunicación inestable: Oxidation of MJ connectors, high-failure-rate interface.
Fuji HAKKO MONITOUCH V8 Series HMI Full Model List
V8 series discontinued in 2017, programming software: V-SFT; suffix definition: N=AC100-240V AC supply, D=DC24V DC supply, i=built-in Ethernet port.
Sufijo-0XX indicates firmware version (e.g.-080), not part of hardware model designation.
Definición del código del modelo
| Personaje | Significado | ||
| i | On‑board RJ45 Ethernet LAN (high‑function version); no “i” = no Ethernet | ||
| S | SVGA 800×600 TFT | ||
| do | VGA 640×480 TFT | ||
| t | VGA 640×480 TFT (RGB/video expansion capable) | ||
| incógnita | XGA 1024×768 TFT | ||
| t | QVGA TFT; METRO | Monochrome; CH | 7.5‑inch handheld with enable switch |
| norte | AC100‑240V power; D | Alimentación de 24 V CC | |
| METRO | Matrix touch; no “METRO” = analog resistive touch |
Full Series Grouped by Screen Size
5.7-inch|QVGA 320×240|DC24V(D) power only
V806 series, no AC variants
V806MD: Monochrome display, sin Ethernet
V806iMD: Monochrome display, Ethernet incorporado
V806CD: STN color, sin Ethernet
V806iCD: STN color, Ethernet incorporado
V806TD: TFT color, sin Ethernet
V806iTD: TFT color, Ethernet incorporado
7.5-inch Handheld Unit|VGA 640×480|With Dead-man Safety Enable Switch
V808CH: Handheld, sin Ethernet
V808iCH: Handheld, Ethernet incorporado
DC24V power supply only
8.4-inch|800×600(SVGA)/640×480(VGA), C.A.(norte)/corriente continua(D) power options
SVGA(800×600):
V808SDN (C.A.) / V808SD (corriente continua)
V808iSDN (C.A.) / V808iSD (corriente continua)
VGA(640×480):
V808CDN (C.A.) / V808CD (corriente continua)
V808iCDN (C.A.) / V808iCD (corriente continua)
10.4-inch|V810 Series (V810iCN-080 belongs to this family)
SVGA 800×600
V810SN (C.A.) / V810S (corriente continua)
V810iSN (C.A.) / V810iS (corriente continua)
VGA 640×480 C-type (Standard TFT)
V810CN (C.A.) / V810C (corriente continua)
V810iCN (C.A.) / V810iC (corriente continua)👉 Base hardware unit of your model
VGA 640×480 T-type (RGB/video option module support)
V810TN (C.A.) / V810T (corriente continua)
V810iTN (C.A.) / V810iT (corriente continua)
Matrix-touch variants available (V810iTM-N, V810TM-N etc.), rarely deployed in industry.
12.1-inch SVGA 800×600
V812SN (C.A.) / V812S (corriente continua)
V812iSN (C.A.) / V812iS (corriente continua)
15-inch XGA 1024×768 (Flagship Model)
V815iXN (C.A.) / V815iX (corriente continua)👉V815 only available with Ethernet “i” versión
Referencia de selección rápida
- Con “i” = On-board RJ45 Ethernet; no “i” = No Ethernet interface
- Suffix N = AC100-240V; Suffix D = DC24V
- V806 & V808CH series: DC24V only, no AC models
- -080,-070: Firmware revision only, hardware remains unchanged. Ejemplo: V810iCN-080 = V810iCN hardware + 080 firmware.
OEM Direct Replacement (Serie V9)
| Legacy V8 Model | Recommended V9 Replacement | Observaciones |
| V810iCN‑080 | V9100iS‑080 | Cut‑out compatible, project conversion required in V‑SFT |
| V808iCDN | V9080iSD‑080 | |
| V812iSN | V9120iS‑080 | |
| V815iXN | V9150iX‑080 |
V8 project files cannot be directly downloaded to V9 hardware; perform project conversion within software for migration.
Common Second-hand Unit Failure Patterns
- Resistive touch aging: Touch drift or partial non-response
- Depleted internal lithium coin-cell: Loss of real-time clock and SRAM recipe data
- Oxidation of MJ-8P serial connectors leading to unstable communication
- LED backlight ageing: Yellowing and dim display
Application Scenarios for Fuji HAKKO MONITOUCH V806iMD
V806iMD: 5.7-pulgada, 16-level grayscale monochrome STN display, QVGA 320×240, Fuente de alimentación CC24V, “i” for built-in Ethernet, multi-serial ports (D-SUB9 + dual MJ-8P), 512KB SRAM, tacto resistivo; discontinued hardware, programming software V-SFT.
Key strengths: Monochrome grayscale, bajo consumo de energía, good sunlight readability, Ethernet plus multi-serial ports. Suited for equipment without demand for complex color graphics yet requiring network data upload. Compared with V806MD, integrated Ethernet enables data upload, SCADA host connection and multi-device gateway functions.
Key Feature-Driven Application Attributes
- 16-level monochrome grayscale: Optimized for text, numeric values and simple bar graphs; not suitable for complex color diagrams or process flowcharts; superior sunlight legibility versus early-generation color STN HMIs.
- Ethernet incorporado: PLC data upload, alarm notification upload, multi-PLC gateway functions; V806MD (non-i variant) supports serial communication only.
- Three serial communication channels: D-SUB9 + MJ1/MJ2, connect multiple PLCs, temperature controllers and inverters simultaneously; arriba a 8 external devices concurrent communication.
- DC24V supply: Direct power from cabinet 24VDC system, no AC power circuit required.
- IP65 front panel for cabinet panel mounting; CF-card & USB support for recipe storage, alarm logging and data sampling.
Typical Industries & Equipment Use-cases
1|Stand-alone Compact Machinery (Panel de operador local)
Priority on parameter setup, status monitoring and alarm viewing; complex color visuals not required
Auxiliary injection-molding equipment, secadoras, mezcladores, licuadoras
Compact packaging machines: selladores, small filling machines, etiquetadoras
Press equipment, compact presses, simple tooling fixtures
Maquinaria textil: maquinas bobinadoras, compact textile finishing equipment
Funciones: Configuración de parámetros, production counting, fault alarm display, simple recipe recall; Ethernet transmits production figures and alarm events to plant-level host system.
2|Thermal & Temperature-controlled Equipment
Industrial furnaces, hornos, small heat-treatment furnaces, reflow ovens, curing furnaces
Environmental test chambers, temperatura constante & humidity cabinets
Ventajas: Good visibility under strong workshop lighting; multi-serial ports connect PLC plus multiple temperature controllers concurrently; Ethernet uploads temperature trends and alarms to central control.
3|Water-treatment, Ambiental & Fluid-handling Compact Control Cabinets
Small-scale wastewater equipment, water reclamation, chemical dosing control systems
Local pump-station control cabinets, compact water-purification units
Use-case: Local panel monitoring for pump-valve status, liquid level and flow readings; alarm event logging; Ethernet connects to plant SCADA for data acquisition, no complex color flow charts needed.
4|Workstation Nodes & Auxiliary Stations on Production Lines
Stand-alone workstation controllers on conveyor lines, sorting auxiliary panels
Local control units for material handling conveyors
Single V806iMD connects multiple sub-station PLCs via multi-serial ports, performs data exchange via gateway function, accesses factory LAN through Ethernet.
5|Machinery & Container-mounted Control Cabinets (Sistema DC24V)
Vehicle-mounted industrial equipment, mobile packaged units; container-type compact system control cabinets
Direct compatibility with 24V on-board power supply; IP65 front-panel withstands dust and vibration; good readability under bright ambient light.
6|Retrofit & Spare-part Replacement for Legacy Installations
Replacement of failed original V806iMD on existing machines.
⚠️Avoid arbitrary substitution with color HMIs: Cabinet cut-out dimension 289 × 216.2 mm; most 5.7-inch third-party HMIs feature different cut-out dimensions, cabinet machining modification is required.
❌Unsuitable Applications for V806iMD
- Projects requiring extensive color process flowcharts, animations and image display; select V806iCD / V806iTD color variants instead.
- Applications requiring high-definition color trend curves and sophisticated visualization.
- Severe high-humidity and corrosive environments (enclosed protective cabinet required).
V806iMD vs V806MD Selection Comparison
| Modelo | Ethernet | Diferencia de aplicación |
| V806iMD | ✅On‑board LAN | Data upload, SCADA interconnection, multi‑device gateway, network‑enabled factory projects |
| V806MD | ❌No Ethernet | Stand‑alone local operation only, serial‑link to PLC, no upper‑level data transmission |
OEM Replacement Model
Legacy V806iMD discontinued; recommended OEM successor: TS2060i (5.7-pulgada, cut-out compatible, CC 24 V, on-board Ethernet, color display; V-SFT project conversion and migration required).
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor