Honeywell ST700-STD720-E1AC4AS-1-A-AHB-11S-A-00A0 Smart Differential Pressure Transmitter

This is Honeywell SmartLine STD720 smart differential pressure transmitter with 100kPa measuring range. It adopts 316SS process head + 316diafragma l, silicone oil filling, 1/4″ NPTF process connection, HART protocol, and with local display. Suitable for general industrial differential pressure measurement applications. Model Segment Definition (Full Breakdown) Segment Code Description Series ID ST700-STD720 STD720: SmartLine ...

  • Detalles del producto

This is Honeywell SmartLine STD720 smart differential pressure transmitter with 100kPa measuring range. It adopts 316SS process head + 316diafragma l, silicone oil filling, 1/4″ NPTF process connection, HART protocol, and with local display. Suitable for general industrial differential pressure measurement applications.

  1. Model Segment Definition (Full Breakdown)
SegmentCódigoDescripción
ID de serieST700-STD720STD720: SmartLine differential pressure transmitter, range 100kPa, turndown ratio 100:1
Process Wetted MaterialE1E = Process head: 316 acero inoxidable; 1 = Diaphragm: 316L acero inoxidable
Conexión & BoltAC4A = Process connection: Standard 1/4NPTF internal thread; C = Bolt/Nut material: Carbon steel (galvanized); 4 = Vent/Drain: Dual-ended, standard vent at end position
Fill Fluid11 = DC庐200 Silicone Oil (standard fill fluid, temperature range -40~121掳C)
Mounting OptionAA = No mounting option (standard mounting)
Static Pressure Grade & OpciónAHBAH = Static pressure rating: 10MPa (1450psi); B = Option: With local display
Producción & Protocol11S11 = Output: 4-20mamá + HART protocol; S = Safety certification: General safety approval
Mostrar & MaterialAA = Display type: Standard digital display; Material: Configuración estándar
Additional Option00A000 = No additional options; A0 = Standard configuration without special functions
  1. Core Specification Table
Categoría de parámetroEspecificación detalladaObservaciones
Parámetros básicos
Tipo de mediciónDifferential Pressure (PD)STD720 specially designed for DP measurement
Rango0–100kPa (configurable down to 0–1kPa)Turndown 100:1, Exactitud 0.05% Span
Static Pressure Rating10MPa (1450psi)AH static pressure grade
Overpressure Capability1.5 × Max static pressureSafety overpressure protection
Exactitud & Estabilidad
Clase de precisión0.05% SpanIncludes linearity, hysteresis and repeatability
Temperature Effect±0.01% URL/°CFull range temperature compensation
Long-term Stability±0.1% URL / 5 añosHigh stability design
Process & Ambient
Process Temperature-40~121°CDepends on fill fluid type
Temperatura ambiente-40~85°CStandard operating range
Protección de ingresoIP67 / NEMA 4XDustproof and waterproof, adecuado para entornos hostiles
Explosion-proof CertificationOptional ATEX / IECExConfirm by exact model
Características eléctricas
Voltaje de suministro12.2~35VDCHART protocol requirement
Señal de salida4-20mamá + HART 5.0/7.0Digital communication superimposed on analog signal
Load Resistance0~1000ΩConfiguración estándar
Tiempo de respuesta0.1~60 segundosConfigurable via HART
Mechanical Structure
Process Connection1/4″ NPTF internal thread (dual side)Configuración estándar
Diaphragm Material316L Stainless SteelCorrosion resistant for most industrial media
Process Head Material316 Stainless SteelMatched with diaphragm material
Bolt MaterialCarbon Steel (Galvanized)Estándar; 316SS optional
Material de la carcasaLow-copper aluminum alloy with polyester powder coatingLightweight and corrosion resistant
  1. Lista de accesorios (Estándar + Opcional)

Configuración estándar

  1. Transmitter Main Unit: Including sensor module, electronic module and housing
  2. Process Connection Gasket: Glass-filled PTFE (estándar)
  3. Mounting Bracket: Standard bracket for pipe or wall mounting
  4. Bloque de terminales: Built-in terminal, supports 2-wire connection
  5. Operation Manual: Instalación, commissioning and maintenance guidelines
  6. Calibration Certificate: Factory calibration record with traceable accuracy

Common Optional Accessories

Accessory TypeModelo / DescripciónSolicitud
Communication ModuleHART / DE Protocol ModuleDigital communication expansion
Módulo de visualizaciónRemote Display UnitTemperatura alta / hazardous area installation
Mounting FittingsFlange adapter, pipe bracketSpecial mounting requirements
Process FittingsReducer adapter, sealing partsDifferent interface conversion
Protection DeviceRain cover, Explosion-proof junction boxHarsh environment protection
Calibration ToolHART Handheld Communicator, Calibration SoftwareOn-site calibration and configuration
  1. Competitor Replacement / Cross-brand Comparison
MarcaModeloCore Parameter ComparisonReplaceability
HoneywellSTD720-E1AC4AS-1-A-AHB-11S-A-00A0100kPa, 0.05% accuracy, 10MPa static pressure, HART, 316diafragma lOriginal same-series replacement
Rosemount(Emerson)3051CD0A02A1AB1H2L4M5100kPa, 0.075% accuracy, 10.3MPa static pressure, HART, 316diafragma lAlto (confirm mounting dimension)
YokogawaEJA110A-DLS4A-92DA100kPa, 0.075% accuracy, 10MPa static pressure, HART, 316diafragma lAlto (protocol compatible)
siemensSITRANS P DS III100kPa, 0.075% accuracy, 10MPa static pressure, HART, 316diafragma lMedio (confirm turndown ratio)
TEJIDO266DSH100kPa, 0.065% accuracy, 10MPa static pressure, HART, 316diafragma lMedio (mounting structure difference)

Replacement Key Points:

  1. Match measuring range, accuracy grade and static pressure resistance
  2. Keep identical process connection type (NPTF / Flange)
  3. Ensure compatibility of communication protocol (HART version)
  4. Mounting dimension and weight shall meet site requirements
  5. Directrices de selección & Soluciones alternativas

Core Selection Factors

  1. Rango de medición: Confirm actual differential pressure; STD720 turndown 100:1 covers 0–1kPa ~ 0–100kPa
  2. Static Pressure Condition: System static pressure ≤10MPa (AH grade); higher pressure requires BH grade (20MPa)
  3. Media Property: Corrosive media requires Hastelloy C-276 or Monel diaphragm
  4. Rango de temperatura: Above 121°C select high-temperature silicone oil (DC®704) or fluorinated fill fluid
  5. Certificación de seguridad: Explosion hazardous area select matched ATEX/IECEx certified model
  6. Communication Requirement: Choose HART/DE for remote configuration and diagnosis

Modelos alternativos recomendados

Escenario de aplicaciónModelo recomendadoVentaja
Standard Industrial DP MeasurementSTD720-E1AC4AS-1-A-AHB-11S-A-00A0Rentable, fits most working conditions
Corrosive MediaSTD720-E2HC4AS-1-A-AHB-11S-A-00A0Hastelloy C-276 diaphragm, resistant to strong acid & alkali
High Temperature (>121掳C)STD720-E1AC4AS-3-A-AHB-11S-A-00A0DC庐704 high-temp silicone oil, range -40~204C
High Static Pressure (>10MPa)STD720-E1AC4AS-1-B-BHB-11S-A-00A0BH grade, withstand 20MPa system pressure
Wireless CommunicationSTD720-E1AC4AS-1-A-AHB-16S-A-00A0WirelessHART protocol, reduce wiring cost

Instalación & Recomendaciones de mantenimiento

  1. Mounting Position: Avoid severe vibration and sharp temperature change; horizontal installation recommended
  2. Process Connection: Ensure good sealing to avoid leakage affecting measurement accuracy
  3. Wiring Requirement: Use shielded cable with single-end grounding to reduce EMI interference
  4. Calibration Cycle: Annual calibration recommended; shorten to 6 months under harsh conditions
  5. Diagnóstico de fallas: Read diagnostic data via HART communicator for fast troubleshooting

Honeywell STD720-E1AC4AS-1-A-AHB-11S-A-00A0 is a high-performance smart differential pressure transmitter. Featuring 0.05% high accuracy and 100:1 wide turndown ratio, it is widely applied in flow, liquid level and pressure measurement for chemical, petroleum, power and other industries. Modular design and rich optional configurations meet customized demands of various working conditions. Durante la selección, focus on measuring range, presión estática, media characteristics and safety certification to match site operating conditions.

Industrias aplicables & Applications for Honeywell ST700-STD720-E1AC4AS-1-A-AHB-11S-A-00A0

This model is a general industrial differential pressure transmitter with standard 316L diaphragm, regular silicone oil filling, HART protocol and general explosion-proof design. It is suitable for neutral, weakly corrosive, normal temperature and pressure working conditions.

Main Applicable Industries

  1. Petroquímico / Coal Chemical

Tank liquid level, distillation column differential pressure, orifice/Venturi DP flow, process pipeline differential pressure, filter blockage monitoring.

  1. Thermal Power / Cogeneration / Self-owned Power Plant

Boiler drum liquid level, duct/flue wind differential pressure, circulating water/desalted water flow, flue gas filter DP interlock.

  1. Tratamiento de agua & Environmental Engineering

Municipal water supply & drenaje, industrial wastewater, pure water/ultra-pure water system; tank level, membrane system inlet-outlet DP, sewage pipeline flow, grid filter differential pressure.

  1. Metallurgy & Steel / Non-ferrous Metal

Blast furnace duct negative pressure, dust removal pipeline DP, circulating cooling water flow, silo/tank level DP measurement.

  1. Farmacéutico / Bioengineering

Purified water flow, fermenter liquid level, precision filter inlet-outlet DP; 316L material fits sanitary process conditions.

  1. climatización & Automatización de edificios

Industrial plant & commercial complex; air conditioning supply/return water differential pressure, duct wind pressure, unit filter blockage DP alarm.

  1. Cement Building Materials / Glass & Ceramics

Kiln wind pressure DP, dust bag differential pressure, silo DP level measurement, cooling water system monitoring.

  1. Alimento & Beverage / Pulp & Paper

Brewing, bebida, paper industry; slurry level, process water circulation DP, pipeline DP flow measurement.

  1. City Gas / Energy Regulating Station

Gas pipeline DP flow, regulator inlet-outlet differential pressure, pipe network pressure monitoring.

  1. Minería & Coal Preparation / Industrial Mines

Coal washing tank level, slurry pipeline DP, dust removal negative pressure monitoring, process water flow measurement.

General Measurement Scenarios (All Industries)

Liquid level measurement for closed / open tanks

Differential pressure flow measurement via orifice, nozzle and Venturi tube

Micro differential pressure / pressure monitoring for pipelines, air ducts and flues

Blockage DP alarm and interlock for filters, dust bags and filter cartridges

Inapplicable Working Conditions

Not suitable for strongly corrosive media (concentrated acid, strong alkali, chlorine), medium temperature>121°C, system static pressure>10MPa. Special diaphragm, high-temperature fill fluid or high static pressure version is required instead.