Schneider XPSAV11113-24VDC Safety Monitoring Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Schneider XPSAV11113-24VDC Safety Monitoring Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Schneider XPSAV11113-24VDC Safety Monitoring Relay

Model Segment Definition XPSAV11113-24VDC XPSAV: Schneider Safety Monitoring Relay Series, dedicated to dual-channel safety circuits for emergency stop, safety door and safety light curtain. 11113: Internal contact logic and channel configuration code. 24VCC: Rated power supply 24V DC. Core Basic Parameters Item Specification Brand Schneider Product Type Industrial Safety Relay (Dual-channel Redundant Safety Type) Clasificado ...

  • Detalles del producto
  1. Model Segment Definition

XPSAV11113-24VDC

XPSAV: Schneider Safety Monitoring Relay Serie, dedicated to dual-channel safety circuits for emergency stop, safety door and safety light curtain.

11113: Internal contact logic and channel configuration code.

24VCC: Rated power supply 24V DC.

  1. Core Basic Parameters
ArtículoEspecificación
MarcaSchneider
Tipo de productoIndustrial Safety Relay (Dual-channel Redundant Safety Type)
Rated Supply24VCC
Rango de voltaje20.4~26.4VDC
Safety LevelPL d / Cat.3, SIL2
Tipo de montajeDIN35 Rail Mounting
Escenarios de aplicaciónMachine tools, automatic production lines, robot emergency stop / safety door circuits
  1. Características clave
  2. Dual-channel redundant input with safety forced-guided contacts;
  3. Millisecond-level safety cut-off response;
  4. Only supports 24V DC power supply; AC voltage input is prohibited;
  5. Built-in self-diagnosis and circuit monitoring functions.
  6. Compatible Replacement Models
  7. Same-brand direct replacement: Direct replacement with the same model; no upgraded alternative version
  8. Doméstico / Cross-brand compatible models:

Omron G9SA-301 24VDC

Weidmüller Dual-channel Safety Relay 24VDC

Siemens 3RK3 series 24V safety module with equivalent specifications

  1. Notas de aplicación

Safety signals must be connected synchronously through dual channels; single-channel connection cannot work normally;

Strictly prohibit mixed use with AC24V power supply, which will directly burn out the module;

Output contacts are only used for safety circuit control and cannot directly drive heavy loads.

Schneider Safety Monitoring Relay Series List & Comparación entre marcas

  1. Overview of Core Schneider Safety Monitoring Relay Series

Schneider safety monitoring relays are centered on the Preventa XPS series, covering full-scenario safety functions such as emergency stop, safety door, safety light curtain and two-hand control. They are divided into Basic Type and Universal Type, all complying with EN/ISO 13849-1 y CEI 61508 safety standards.

SerieFunción principalSafety LevelAplicación típica
XPSAVDual-channel emergency stop / safety door monitoring with solid-state outputpl y / Cat.4, SIL3Emergency stop circuits for machine tools and automatic production lines
XPSAF/XPSAFLEmergency stop / safety door / light curtain monitoring, high/low level inputPL e/Cat.4(SIL3) / PL d/Cat.3(SIL2)Safety light curtain and safety door interlock monitoring
XPSACEmergency stop button and limit switch monitoringpl y / Cat.4, SIL3Simple emergency stop circuit and equipment limit protection
XPSARDual-channel emergency stop / light curtain monitoring, 7 safety contacts + 2 contactos auxiliarespl y / Cat.4, SIL3Complex safety circuits and multi-equipment linkage
XPSATE/XPSATRConfigurable safety relay with time delay functionpl y / Cat.4, SIL3Safety scenarios requiring delay control
XPSCMDedicated monitoring module for light curtainspl y / Cat.4, SIL3Safety light curtain / grating monitoring
XPSUAF/XPSUATUniversal configurable safety relaypl y / Cat.4, SIL3Replacement for XPSAR / XPSATE series
  1. Model Segment Coding Rules

Taking XPSAV11113-24VDC as an example, Schneider safety relay model coding follows unified logic:

Segmento de códigoSignificadoExample Description
XPSProduct category identifier, Preventa safety relay seriesAll safety relays start with this prefix
AV/AF/AC/AR/ATEFunctional series codeAV=Emergency stop + solid-state output; AF=Standard emergency stop; AC=Basic emergency stop
11113Internal configuration code1st digit = channel quantity; last four digits = contact type / cantidad / reset mode
-24VDC/230VACRated supply voltage24En DC / 230V y; some models support universal AC/DC
PAGTerminal type identifier (opcional)P=Plug-in terminal; no suffix=screw terminal
  1. Complete Model List of Each Series

3.1 XPSAV Series (Parada de emergencia + Solid-State Output)

ModeloVoltaje de suministroSafety ContactsAuxiliary OutputModo de reinicio
XPSAV11113-24VDC24VCC3NO Instantaneous3 Solid-state OutputAutomatic / Monitored Reset
XPSAV11113P-24VDC24VCC3NO Instantaneous3 Solid-state OutputAutomatic / Monitored Reset (Plug-in Terminal)
XPSAV11123-24VDC24VCC3NO Instantaneous + 3NO Time-delay3 Solid-state OutputReinicio manual
XPSAV11123P-24VDC24VCC3NO Instantaneous + 3NO Time-delay3 Solid-state OutputReinicio manual (Plug-in Terminal)
XPSAV37113-230VAC230VACACIONES3NO Instantaneous3 Solid-state OutputAutomatic / Monitored Reset
XPSAV37113P-230VAC230VACACIONES3NO Instantaneous3 Solid-state OutputAutomatic / Monitored Reset (Plug-in Terminal)

3.2 XPSAF/XPSAFL Series (Standard Emergency Stop / Light Curtain Monitoring)

ModeloVoltaje de suministroSafety LevelInput TypeSafety Contacts
XPSAF513024VAC/DCpl y / Cat.4High/Low Level Dual-channel3NO
XPSAF5130P24VAC/DCpl y / Cat.4High/Low Level Dual-channel3NO (Plug-in Terminal)
XPSAF5130P-230VAC230VACACIONESpl y / Cat.4High/Low Level Dual-channel3NO (Plug-in Terminal)
XPSAFL513024VAC/DCPL d / Cat.3High Level Dual-channel3NO (No Short-circuit Detection)
XPSAF3730P230VACACIONESpl y / Cat.4High/Low Level Dual-channel3NO (Plug-in Terminal)

3.3 XPSAC Series (Basic Emergency Stop Monitoring)

ModeloVoltaje de suministroSafety ContactsCaracterísticas
XPSAC512124VCC2NOTipo básico, Cat.3
XPSAC5121P24VCC2NOTipo básico, Cat.3 (Plug-in Terminal)
XPSAC3721P230VACACIONES2NOTipo básico, Cat.3 (Plug-in Terminal)
XPSAC514024VCC4NOEnhanced Type, Cat.4

3.4 XPSAR Series (Multi-contact Emergency Stop / Light Curtain Monitoring)

ModeloVoltaje de suministroSafety ContactsContactos auxiliaresCaracterísticas
XPSAR311144P24VAC/DC7NO2CAROLINA DEL NORTEDual-channel, Cross-wire Monitoring
XPSAR351144P115VACACIONES7NO2CAROLINA DEL NORTEDual-channel, Cross-wire Monitoring
XPSAR371144P230VACACIONES7NO2CAROLINA DEL NORTEDual-channel, Cross-wire Monitoring

3.5 Universal XPSU Series (Replacement for Traditional Series)

ModeloReplaced SeriesVoltaje de suministroSafety ContactsContactos auxiliares
XPSUAF13APXPSAF24VAC/DC3NO1CAROLINA DEL NORTE (Diagnostic Output)
XPSUAF13ACXPSAF24VAC/DC5NO4 Contactos auxiliares
XPSUAT13A3APXPSATE24VAC/DC3NO + 3 Time-delay NO3 Solid-state Output
  1. Cross-Brand Comparison Table (Modelos convencionales)
Schneider ModelOmron ReplacementReemplazo de SiemensPilz ReplacementReemplazo de Weidmüller
XPSAV11113-24VDCG9SA-301 24VDC3SK1111-2AB40PNOZ X3 24VDCSAFESERIES 24VDC Dual-channel
XPSAF5130G9SA-501 AC/DC243SK1122-2AB40PNOZ X4 24VAC/DCPROMAX 24VAC/DC 3NO
XPSAC5121G9SA-101 24VDC3SK1101-2AB40PNOZ X1 24VDCSAFESERIES 24VDC 2NO
XPSAR311144PG9SA-321 AC/DC243SK1162-2AB40PNOZ X7 24VAC/DCPROMAX 24VAC/DC 7NO+2NC
XPSUAF13APG9SA-511 AC/DC243SK2122-2AB40PNOZ X4P 24VAC/DCPROMAX 24VAC/DC 3NO+Diagnostic
  1. Directrices de selección & Replacement Precautions
  2. Safety Level Matching: The PL / Cat. level and SIL level of the replacement model shall not be lower than the original one.
  3. Input Type Compatibility: Distinguish High/Low Level Input and PNP/NPN types; XPSAF supports dual types, while XPSAFL only supports high level.
  4. Consistent Reset Mode: Divided into Automatic Reset, Monitored Reset and Manual Reset, which shall match the application scenario.
  5. Tipo de terminal: Suffix P stands for plug-in terminal; no suffix for screw terminal. Pay attention to mounting compatibility during replacement.
  6. Voltaje de suministro: Strictly distinguish DC24V, AC230V and Universal AC/DC to avoid module burnout.
  7. Series Replacement Roadmap

Schneider is gradually replacing traditional series with the XPSU Universal Series:

XPSAR → Combined XPSUAF + XPSUEP or XPSUAT series

XPSATE/XPSATR → XPSUAT series

XPSAF/XPSAV → XPSUAF series

Anterior:

Próximo: