Authoritative Model Breakdown Definition
| Segmento de código | Significado | Observaciones |
| E82EV | Lenze 8200 Vector Inverter Series | Classic legacy model, interrumpido & fin de vida |
| 551 | Power rating: 5.5kilovatios (3-fase 400V) | Not 0.55kW; distinguish from E82EV055 series |
| 4 | Voltage specification: 3-phase 380~480V AC | Standard industrial 400V class voltage |
| do | Configuration type: Standard version without built-in EMC filter | Version with built-in filter: E82EV551-4B |
| LENZE | Brand identification: Lenze Germany | Well-known brand in industrial automation |
- Core Rated Specifications (Official Version)
| Segmento de código | Significado | Observaciones |
| E82EV | Lenze 8200 Vector Inverter Series | Classic legacy model, interrumpido & fin de vida |
| 551 | Power rating: 5.5kilovatios (3-fase 400V) | Not 0.55kW; distinguish from E82EV055 series |
| 4 | Voltage specification: 3-phase 380~480V AC | Standard industrial 400V class voltage |
| do | Configuration type: Standard version without built-in EMC filter | Version with built-in filter: E82EV551-4B |
| LENZE | Brand identification: Lenze Germany | Well-known brand in industrial automation |
- Key Functional Features
- Vector Control Performance: High torque output at low speed; provides 150% par nominal a 0,5 Hz, ideal for constant-torque loads (p.ej., cintas transportadoras, mezcladores).
- Built-in Functional Modules:
Multi-function digital input/output (standard 4DI/2DO)
Entrada analógica (0~10V / 4~20mA)
Built-in PID controller for fan & pump closed-loop control
Multi-speed control (máximo. 16 velocidades), swing frequency control, automatic energy-saving operation
- Funciones de protección:
sobrecorriente / Sobrecarga / Sobretensión / Subtensión / Overheating protection
Motor phase loss / Protección de falla a tierra
Optional motor PTC temperature monitoring
- Communication Expansion: Supports CANopen, Profibus-DP, Modbus RTU and other fieldbuses (optional communication card required).
- Terminal Wiring Definition (Core Terminals)
| Elemento de parámetro | Valor | Descripción |
| Potencia nominal | 5.5kilovatios | Under 3-phase 400V operating condition |
| Corriente de salida nominal | 11.5A | Continuous operating current |
| Voltaje de entrada | 3AC 380~480V, 50/60Hz | Allowable fluctuation: ±10% |
| Voltaje de salida | 0 ~ Input Voltage (3-fase) | Synchronously adjusted with frequency |
| Rango de frecuencia de salida | 0~480Hz | Under vector control mode |
| Modo de control | Control V/F, Control vectorial sin sensores | Closed-loop vector optional (requires encoder) |
| Capacidad de sobrecarga | 150% corriente nominal / 60s | Suitable for short-time heavy-duty operation |
| 180% corriente nominal / 2s | ||
| Clase de protección | IP55 | A prueba de polvo & impermeable, suitable for on-site workshop installation |
| Método de enfriamiento | Forced air cooling (built-in fan) | Good ventilation must be ensured |
| Unidad de frenado incorporada | Equipped (standard for models ≤11kW) | External braking resistor required for fast stop |
| Dimensiones (Ancho×Alto×Profundidad) | Aprox.. 180×140×80mm | Diseño compacto, ahorra espacio de instalación |
| Peso | Aprox.. 3.5kilos | Wall-mounted type, low load-bearing requirement |
- Discontinued Replacement Solution (Official Recommendation)
- Original Lenze Replacement (Highest Compatibility)
i550 Series 5.5kW 400V: I55AP055C00811W7MS (IP55 protection)
i750 Series 5.5kW 400V: Higher performance, supports complex control requirements
> Replacement advantage: Terminal layout and parameter logic highly compatible with E82EV, no major electrical design modification required.
- Alternative Brands with Same Specifications (Reemplazo directo)
| Tipo de terminal | Terminal No. | Descripción de la función | Wiring Instruction |
| Main Circuit Input | L1/L2/L3 | 3-phase power input | 380~480V AC; circuit breaker and contactor required |
| Main Circuit Output | UV/V/W | Motor connection terminals | Connect to 3-phase asynchronous motor; pay attention to phase sequence |
| DC Bus | DC+/DC- | terminales de bus CC | External braking resistor available (75惟/1000W recommended) |
| Controlar el poder | X1:1/2 | 24V DC control power | Input range: 20.4~28.8V DC |
| Entrada digital | X1:3~6 | DI1~DI4 | Configurable for start/stop, adelante/atrás, multivelocidad, etc.. |
| Salida digital | X1:7~8 | DO1~DO2 | Relay output for fault alarm & running indication |
| Entrada analógica | X2:1~2 | AI1 (0~10V) | Speed reference signal |
| Entrada analógica | X2:3~4 | AI2 (4~20mA) | Optional speed / referencia de par |
| Interfaz de comunicación | X3 | Fieldbus interface | Optional communication module required |
- Códigos de falla comunes & Solución de problemas
| Código de falla | Tipo de falla | Posibles causas | Solución |
| E.OC | sobrecorriente | Motor short circuit, too short acceleration time, sudden load change | Check motor winding, extender el tiempo de aceleración, reduce load fluctuation |
| E.OU | Sobretensión | Too fast deceleration, high grid voltage, no braking resistor connected | Ampliar el tiempo de desaceleración, check grid voltage, connect braking resistor |
| E.OL | Sobrecarga | Excessive load, mismatched motor, poor heat dissipation | Reduce load, replace matched motor, clean heat dissipation channel |
| E.OH | Calentamiento excesivo | Ambient temperature too high, fan failure, poor ventilation | Lower ambient temperature, replace fan, improve ventilation |
| E.LU | Subtensión | Low grid voltage, pérdida de fase, power fluctuation | Inspect power grid, repair phase loss, install voltage stabilizer |
| E.GF | Ground Fault | Poor motor grounding, damaged output cable insulation | Check motor insulation, replace output cable |
- Key Operation Precautions
- Requisitos de instalación
Vertical wall-mounted installation; reserve ≥10cm heat dissipation space top and bottom
Temperatura ambiente: -10℃ ~ +40℃ (Se requiere reducción de potencia por encima de 40 ℃)
Avoid installation in dusty, oily, corrosive gas environments
- Puntos clave de puesta en servicio
Perform motor parameter auto-tuning (Group P09 parameters) for first use
Enter motor nameplate data (potencia nominal, actual, velocidad) under vector control mode
Braking resistor selection: 75Ω/1000W recommended for 5.5kW model, install in well-ventilated area
- Sugerencias de mantenimiento
Regularly clean cooling fan and filter (every 3~6 months)
Check main circuit terminal tightness (cada 6 meses)
Perform insulation test if stored unused for more than 6 meses
- Selección & Replacement Guideline
- Existing Equipment Maintenance: Prioritize original refurbished or dismantled spare parts for cost performance.
- New Project Design: Strongly recommended to replace with Lenze i550 series for better performance and lower maintenance cost.
- Pasos de reemplazo
Confirm motor parameters (fuerza, Voltaje, actual, velocidad)
Match replacement model rated output current (≥11.5A)
Retain original control circuit wiring; only minor parameter modification needed
Complete motor auto-tuning to ensure control accuracy
Complete Lenze Inverter Model List & Reglas de nomenclatura
- Core Series Overview
Lenze inverter product line covers general inverter, servo drive and dedicated control scenarios. Below are the most widely used industrial series and model systems:
| Nombre de la serie | Tipo | Rango de potencia | Características principales | Estado |
| 8200 Vector (E82EV) | General Vector Inverter | 0.25kilovatios~90kW | Classic legacy, V/F + Sensorless Vector, IP55 | Interrumpido |
| i500 Series | General / Servo Inverter | 0.25kW~110kW | Diseño modular, high compatibility, successor of 8200 | Active Mainstream |
| 8400 Serie | High-performance General Inverter | 0.37kW~400kW | Stateline/Highline/Topline grading, built-in PLC | Activo |
| SMVector (ESV) | Economy General Inverter | 0.25kW~22kW | Rentable, fácil operación, comunicación modbus | Activo |
| i750/i950 Series | Servo Inverter | 0.37kW~110kW | Multi-axis control, built-in PLC, EtherCAT communication | High-end Active |
- Detailed Model Naming Rules
2.1 8200 Vector Series (E82EV) Naming Format
E82EV P P P V C [ K X X X]
E82EV: 8200 Vector series identifier
PPP: Power code
V: Voltage grade (2=230V, 4=400V)
do: Configuración (B=With EMC Filter, C=Without EMC Filter)
Sufijo: Opción / Enfriamiento / Protection code
Power Code Correspondence
| Código | Fuerza | Código | Fuerza | Código | Fuerza |
| 55 | 0.55kilovatios | 152 | 1.5kilovatios | 302 | 3.0kilovatios |
| 75 | 0.75kilovatios | 222 | 2.2kilovatios | 402 | 4.0kilovatios |
| 112 | 1.1kilovatios | 301 | 3.0kilovatios | 551 | 5.5kilovatios |
| 151 | 1.5kilovatios | 401 | 4.0kilovatios | 751 | 7.5kilovatios |
| 221 | 2.2kilovatios | 552 | 5.5kilovatios | 113 | 11kilovatios |
Voltaje & Configuration Reference
2: Single-phase 230V / 3-fase 230V
4: 3-phase 380~480V (400V Class)
B: Filtro EMC incorporado
do: Without Built-in EMC Filter
I55A: i550 series identifier
E/D: Estándar / Dual-axis type
PPP: Power code
B/F: EMC class
Follow-up codes: Tamaño, Voltaje, seguridad, comunicación, versión, montaje & special version
- Complete Model List by Series
3.1 8200 Vector Series (E82EV) Modelos comunes
3-phase 400V Class (Without EMC Filter – Type C)
E82EV0551-4C (0.55kilovatios)
E82EV0751-4C (0.75kilovatios)
E82EV1121-4C (1.1kilovatios)
E82EV1521-4C (1.5kilovatios)
E82EV2221-4C (2.2kilovatios)
E82EV3021-4C (3.0kilovatios)
E82EV4021-4C (4.0kilovatios)
E82EV551-4C (5.5kilovatios) – Focus model
E82EV751-4C (7.5kilovatios)
E82EV1131-4C (11kilovatios)
E82EV1531-4C (15kilovatios)
E82EV1831-4C (18.5kilovatios)
E82EV2231-4C (22kilovatios)
3-phase 400V Class (With Built-in EMC Filter – Type B)
E82EV0551-4B (0.55kilovatios)
E82EV0751-4B (0.75kilovatios)
E82EV551-4B (5.5kilovatios) – EMC version of E82EV551-4C
E82EV2231-4B (22kilovatios)
Single/3-phase 230V Class
E82EV0551-2C (0.55kilovatios)
E82EV0751-2C (0.75kilovatios)
E82EV1121-2C (1.1kilovatios)
E82EV1521-2C (1.5kilovatios)
E82EV2221-2C (2.2kilovatios)
E82EV3021-2C (3.0kilovatios)
3.2 i550 Series (E82EV Replacement Series) Modelos recomendados
IP55 Protection (Direct Replacement for E82EV)
| Fuerza | Modelo | Observaciones |
| 0.55kilovatios | I55AP055C00811W7MS | Replace E82EV0551-4C |
| 1.5kilovatios | I55AP152C00811W7MS | Replace E82EV1521-4C |
| 5.5kilovatios | I55AP055C00811W7MS | Replace E82EV551-4C |
| 7.5kilovatios | I55AP751C00811W7MS | Replace E82EV751-4C |
| 11kilovatios | I55AP113C00811W7MS | Replace E82EV1131-4C |
IP20 Cabinet-mounted Type
I55AE055F10V1000S (0.55kilovatios, Class C2 EMC)
I55AE152F10V1000S (1.5kilovatios, Class C2 EMC)
I55AE551F10V1000S (5.5kilovatios, Class C2 EMC)
3.3 8400 Series Main Models
8400 Stateline (E84AVSCE) Economy High-performance
E84AVSCE0554SX0 (0.55kilovatios, 400V)
E84AVSCE1524SX0 (1.5kilovatios, 400V)
E84AVSCE5514SX0 (5.5kilovatios, 400V)
8400 Highline (E84AVTCE) High-end Functional Type
E84AVTCE0554VX0 (0.55kilovatios, 400V)
E84AVTCE5514VX0 (5.5kilovatios, 400V)
8400 Topline (E84AVPCE) Top Performance with Built-in PLC
E84AVPCE0554PX0 (0.55kilovatios, 400V)
E84AVPCE5514PX0 (5.5kilovatios, 400V)
3.4 SMVector Series (ESV) Models
ESV055N01SXB (0.55kilovatios, 230V, NEMA 1)
ESV152N01SXB (1.5kilovatios, 230V, NEMA 1)
ESV551N04SXB (5.5kilovatios, 400V, NEMA 1)
ESV055N04SXB (0.55kilovatios, 400V, NEMA 1)
3.5 i750 / i950 Servo Inverter Series
i750 Single-axis: I75AE112D1AV00332G (1.1kilovatios, 230V)
i750 Dual-axis: I75DE112D1AV00332G (Dual-axis 1.1kW, 230V)
i950 Single-axis: I95AE551D1AV00332G (5.5kilovatios, 400V)
i950 Dual-axis: I95DE551D1AV00332G (Dual-axis 5.5kW, 400V)
- E82EV Discontinued Replacement Guide
| Original E82EV Model | Recommended Replacement Model | Ventajas de reemplazo |
| E82EV551-4C | I55AP055C00811W7MS (i550 IP55) | Compatible terminal layout & parameter logic, no electrical redesign needed |
| E82EV551-4B | I55AP055B00811W7MS (i550 IP55 with EMC) | Filtro EMC incorporado, complies with latest standards |
| E82EV751-4C | I55AP751C00811W7MS | 7.5kW full power replacement, 30% performance improvement |
- Quick Selection Reference Table
| Escenario de aplicación | Recommended Series | Rango de potencia | Modo de control | Clase de protección |
| Conveyor / Maquinaria de embalaje | i550 | 0.55~22kW | Control de vectores | IP55/IP20 |
| Admirador / Water Pump | 8400 Stateline | 0.37~400kW | V/F + PID | IP20 |
| High-precision Positioning | i750/i950 | 0.37~110kW | Servocontrol | IP20 |
| Economy Speed Regulation | SMVector | 0.25~22kW | V/F | IP31/IP65 |
| Old Equipment Maintenance | E82EV Spare Parts | 0.25~90kW | Control de vectores | IP55 |
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares




















NH42-63-318x560.png)