Mitsubishi AJ65SBTB1-32D Compact Remote Input Module

AJ65SBTB1-32D is a Mitsubishi MELSEC CC-Link compact remote DC digital input module Model Code Definition AJ65: CC-Link remote I/O module series SBTB1: Compact remote I/O main body 32: 32 I/O points D: Entrada digital (entrada CC) Key Specifications Item Parameter Network CC-Link Ver.1/2 Type Remote DC digital input module Points 32 input points Occupied stations ...

  • Detalles del producto

AJ65SBTB1-32D is a mitsubishi MELSEC CC-Link compact remote DC digital input module

  1. Definición del código del modelo

AJ65: CC-Link remote I/O module series

SBTB1: Compact remote I/O main body

32: 32 puntos de E/S

D: Entrada digital (entrada CC)

  1. Especificaciones clave
ArtículoParámetro
RedCC-Link Ver.1/2
TipoRemote DC digital input module
Agujas32 input points
Occupied stations1 station
Tensión de entrada nominalCC 24 V
Corriente de entradaAprox.. 7mA por punto
Input response time1.5EM (OFF→ON / ON→OFF)
Input polarityCompatible con fregadero/fuente (works with both NPN and PNP sensors)
AislamientoOptocoupler isolation
Fuente de alimentación del móduloCC 24 V; Module power consumption approx. 45mamá
ON threshold≥14VDC / ≥3.5mA
OFF threshold≤6VDC / ≤1.7mA
Dimensiones generalesW179 × H50 × D40 mm
Peso0.25 kilos
TerminalesM3 screw terminal block
Clase de protecciónIP2X
  1. Escenarios de aplicación

Remote sensor signal acquisition for production lines: sensores fotoeléctricos, interruptores de proximidad, interruptores magnéticos, pushbutton signals

Distributed I/O architecture to reduce bulk hardwiring from control cabinets to field devices via CC-Link bus networking

Compatible with Mitsubishi Q-series, FX3U/FX5U PLCs equipped with CC-Link master station

  1. Distinción de modelo (Frequently Confused Models)
  2. AJ65SBTB1-32D: Versión estándar, 1.5respuesta ms, 32DE
  3. AJ65SBTB1-32D1: High-speed version, 0.2respuesta ms, 32DE, preferred for high-frequency sensors
  4. AJ65SBTB1-32T: 32-point transistor output module
  5. AJ65SBTB1-32DT: 16-input +16-output mixed I/O module

Lifecycle note: AJ65SBTB1-32D is discontinued. Only stock or used units available. Para nuevos proyectos, AJ65SBTB1-32D1 is the preferred replacement. Same mounting dimensions and terminal definitions; only faster response speed, no se requiere modificación del programa.

  1. Instalación & Pautas de cableado
  2. Fuente de alimentación: Independent DC24V supply for module itself; sensors also use DC24V signal
  3. CC-Link bus: DA/DB cables; 110Ω terminating resistors fitted at both ends of the bus
  4. Terminales comunes: 8 points per common group, supports NPN/PNP. Keep unified polarity during wiring
  5. Earthing: Reliable earthing on FG terminal to reduce bus interference
  6. Station number setting: DIP switches on module body to set CC-Link station number
  7. Solución de problemas de fallas comunes
  8. RUN indicator off: Check DC24V supply, polarity and internal fuse
  9. ERR indicator flashing: CC-Link communication failure. Inspect DA/DB wiring, terminating resistors, duplicate station numbers, shield earthing
  10. No signal at input channel: Verify sensor power supply and common polarity; measure terminal voltage with multimeter; check for damaged optocoupler channel
  11. False signal triggering: Cable interference, use shielded cable; check response time. Para cables largos, select D1 high-speed variant
  12. Alternative Selection List
  13. Direct drop-in replacement (mismo tamaño & terminales): AJ65SBTB1-32D1 (Recomendado para nuevos proyectos.)
  14. Domestic compatible CC-Link 32DI remote I/O: Innovación, Inwell CC-Link remote input modules (verify CC-Link version and register mapping)
  15. Upgrade to CC-Link IE Field bus: NZ-series remote I/O (hardware architecture completely different; PLC program rewrite required)
  16. Referencia del código HS

8537101100 (Programmable controller digital input module, for customs declaration only; subject to customs final judgement)

CC-Link Master Station Parameter Configuration (for AJ65SBTB1-32D, Remote I/O Station, ocupa 1 station)

Master module: QJ61BT11N (Q-series); software de programación: GX Obras2; AJ65SBTB1-32D = Remote I/O Station, ocupa 1 station, 32-point RX input, no RY output and no RW registers.

Master station fixed station number: Station 0. Slave AJ65SBTB1-32D station number set via DIP switch: 1~64. Station 1 is used in this example.

  1. Hardware DIP Switch (Set AJ65SBTB1-32D first!)
  2. Station number DIP switch: Binary DIP switch for station address (p.ej. Station 1 = 00000001)
  3. Baud rate DIP switch: Must match master station baud rate

000 → 156kbps

001 → 625kbps

010 → 2.5Mbps (most commonly used on site)

011 → 5Mbps

100 →10Mbps

Fit 110Ω terminating resistors at both ends of the bus

  1. GX Works2 Q-series CC-Link Master Basic Parameters

Path: Project Navigator → Parameters → Network Parameters → CC-Link

ArtículoSetting ValueObservaciones
Modelo de móduloQJ61BT11NMaster station module
Start I/O Address0000 (modify according to actual slot)Module I/O address
Master Station No.0CC-Link master fixed at station 0
ModoRemote Net(Ver.1 Mode)AJ65SBTB1-32D is Ver.1 compatible remote I/O
Total Connected Stations1For single AJ65SBTB1-32D network; update for multiple slaves
Communication Speed2.5mbpsMust match slave DIP baud rate
Retry Count3Por defecto
Standby MasterNingunoStandard single-master system
Scan ModeAsynchronousPor defecto

Station Information (Crítico!)

Click [Station Information], add Station No.1:

ArtículoConfiguración
Station No.1DIP station number of AJ65SBTB1-32D
Station TypeRemote I/O Station⚠️ NOT Remote Device Station!
Occupied Stations1AJ65SBTB1-32D fixed as 1 station
RX(Remote Input)32 agujasX0~X1F (corresponds to 32DI)
RY(Remote Output)0 agujasThis module has inputs only, no outputs
RWw/RWr0 palabrasRemote I/O stations do not use registers

Remote I/O station soft element mapping rule:

Station1: RX0~RX1F correspond to the 32 DI channels of AJ65SBTB1-32D

PLC internal soft elements for master station: RX mapped to PLC X addresses (auto-refreshed by GX Works)

  1. Soft Element Refresh Mapping (QJ61BT11N)

CC-Link automatic refresh:

RX: Remote input → PLC internal X

RY: PLC output → Remote module output

RWw: PLC writes to remote registers

RWr: Remote registers read into PLC

AJ65SBTB1-32D (Station 1)

RX0~RX1F (32poco) = 32 DC input channels of the module

Ejemplo: Sensor ON → RXn=ON; read RX bit directly in program.

  1. FX5U + FX5-CCL-MS (FX5U CC-Link Master, GX Works2/3)

FX5U with FX5-CCL-MS master card can connect AJ65SBTB1-32D

  1. Project → Parameters → CC-Link Parameters, Master type: Master station, Ver.1 mode
  2. Add station entry for Station 1: Remote I/O Station, ocupa 1 station, RX=32, RY=0
  3. Soft element refresh: RX mapped to FX5U X or M (customizable refresh address)

FX5U built-in Ethernet CC-Link IE Field Basic cannot directly connect old AJ65SBTB1-32D. This classic CC-Link uses RS485 bus and requires FX5-CCL-MS module.

  1. Descargar & Pasos de puesta en marcha
  2. Complete all parameter settings, hacer clic [Controlar], confirm no errors;
  3. Write [Parámetros + Program] to PLC; PLC reset;
  4. Power up remote modules with DC24V first, then power up PLC master station;
  5. Observe indicators:

M/S: Master steady ON; CORRER: Slave steady ON;

ERR off = Communication normal; ERR flashing = bus fault;

  1. Online monitor RX soft elements; trigger sensors and verify corresponding RX bits turn ON/OFF.
  2. Errores comunes
  3. ❌ Wrong station type: selected as Remote Device Station → communication failure; must use Remote I/O Station
  4. ❌ Baud rate mismatch between master and slave
  5. ❌ Missing terminating resistors, random disconnection over long cables
  6. ❌ Duplicate station numbers, frequent in multi-slave networks
  7. ❌ Ver.2 mode enabled; old AJ65SBTB1-32D is Ver.1 compatible, use Remote Net Ver.1 Mode by priority
  8. Sample Program (CALLE / Ladder compatible)

Directly monitor RX0~RX1F, no special communication instruction required, CC-Link auto cyclic refresh.

Ejemplo: LD RX0 reads channel 0 input of AJ65SBTB1-32D.

Optional extensions available upon request:

  1. Screenshot-style GX Works2 CC-Link parameter setup guide
  2. Batch parameters for multiple AJ65SBTB1-32D network (Station1, Station2, Station3…)
  3. Communication fault code (ERR lamp) reference table
  4. Ladder example to map RX to internal M relays for easier programming

CC-Link ERR Lamp + QJ61BT11N Fault Code Reference Table (For AJ65SBTB1-32D)

Two sections: Quick LED Indicator Diagnosis (On-site check) + Hex Fault Codes read from GX Works Diagnosis (Precise troubleshooting)

Master: QJ61BT11N; Slave: AJ65SBTB1-32D

  1. LED Status Quick Reference (Master QJ61BT11N ERR Lamp)
Master ERR LampDescripción de la fallaSolución de problemas
APAGADOCommunication normal–
Encendido fijoAll stations communication failureBus breakage, DA/DB reversed, dual master conflict, parameter error, baud mismatch, missing terminating resistor
BrillantePartial slave fault, faulty station existsSingle/multiple slave offline, duplicate station number, slave power off, slave hardware damage

Slave AJ65SBTB1-32D L.ERR Indicator

Slave L.ERR LampDescripción de la fallaSolución de problemas
APAGADOCommunication normal–
Encendido fijoSlave communication errorStation number out of range, bus broken, power supply abnormal
Regular periodic flashingDIP switch modified under power (station/baud)Apagar, reset DIP switch, repower
Irregular random flashingNoise interference / faulty terminating resistor110惟 resistors at both bus ends, shield earthing, daño del cable, parallel power cable interference

PW lamp OFF: No DC24V supply to slave, check power terminals and fuse first.

L.RUN lamp OFF: Data link not established; master cannot detect this slave station.

  1. QJ61BT11N Master Hex Fault Codes (Read via GX Works CC-Link Diagnosis)
Código de falla(HEX)Nombre de fallaCausaAcción
B823Remote control mode errorIncorrect master mode settingSet network parameter to Remote Net(Ver.1 Mode). AJ65SBTB1-32D does not support Ver.2 extended mode
B983 / B984Invalid module typeMode incompatibility between master and slaveOld AJ65SBTB1-32D is Ver.1 remote I/O; disable Ver.2 mode
BA1BAll stations failureWhole bus communication interruptionDA/DB wiring, 110惟 terminators, tasa de baudios, cable breakage
BBC2Station number setting errorStation number out of range or wrong station typeStation type must be [Remote I/O Station], not Remote Device Station; station range 1~64
BBC5Duplicate master station (multi-master conflict)2 masters on the same CC-Link busCheck bus and keep only one master module
BD85Master hardware failureQJ61BT11N module damageCiclo de energía, replace master module if fault persists
BFFECPU watchdog timeoutCommunication error between PLC CPU and master moduleCheck QCPU backplane, instalación del módulo, PLC reset
C92EDiscrepancia en la velocidad de baudiosMaster baud differs from slave DIP settingSet master baud equal to AJ65SBTB1-32D DIP baud
C932Duplicate station number conflictTwo slaves with identical station DIP settingCheck each module DIP and assign unique station number
C940Data link stopBus break / interference / missing terminatorCheck DA DB wiring, shield earthing, terminating resistors
  1. Q-series CC-Link Special Relay SW (Monitor in GX Works)

Identify offline station quickly via SW registers

  1. SW0080~SW0083: Link error bits, bit maps to station number. ON = fault at that station

SW0080 bit0 = Station1 fault; bit1 = Station2 fault, and so on

  1. SW006B: Detailed error type

0: Normal

1: Transmission line fault

2: Parameter error

3: CRC error (interferencia electromagnética)

4: Timeout error (slave no response)

5: Abort error

6: Setting error

  1. On-site Troubleshooting Sequence (AJ65SBTB1-32D)
  2. Check slave PW lamp: OFF → inspect DC24V supply
  3. Check slave L.RUN / L.ERR lamp
  4. Open GX Works → CC-Link Diagnosis, read fault code + SW0080 to locate faulty station
  5. Verificar: station number, tasa de baudios, station type (Remote I/O Station)
  6. Check DA/DB polarity, 110Ω terminators at both bus ends
  7. Single-point earthing for shield; avoid both-end earthing to prevent ground loop
  8. Separate CC-Link cable away from power cables to reduce interference
  9. Common Pitfall Summary
  10. Remote I/O Station mistakenly selected as Remote Device Station → BBC2 station type error, ERR flashing
  11. Master Ver.2 mode enabled, old AJ65SBTB1-32D incompatible → B983 invalid module type
  12. Terminating resistor fitted only on one end → random flashing, intermittent disconnection
  13. DA DB wires reversed, entire bus down, master ERR steady ON
  14. Modify DIP switches while powered on, slave L.ERR flashes periodically; power cycle to recover

Mitsubishi AJ65SBTB1 Series (CC-Link Compact Remote I/O, Screw Terminal Block, all discontinued, 1 station occupancy)

Suffix definition

D: DC Digital Input; D1: High-speed Input; D5: 5V Input

t: Sink transistor output; T1: High-speed transistor output; TE1: Source transistor output

DT: Mixed Input+Output; k: Special common terminal specification

All modules in this series are Remote I/O Stations (not Remote Device Stations), CC-Link Ver.1 compatible

  1. Pure DC Input Modules (DE)
ModeloAgujasBrief Specification
AJ65SBTB1-8D8DECC 24 V, standard response 1.5ms, NPN/PNP common terminal
AJ65SBTB1-16D16DECC 24 V, standard response 1.5ms
AJ65SBTB1-16D116DECC 24 V, high-speed 0.2ms
AJ65SBTB1-32D32DECC 24 V, standard response 1.5ms (tu modelo objetivo)
AJ65SBTB1-32D132DECC 24 V, high-speed 0.2ms, direct compatible replacement for 32D
AJ65SBTB1-32D532DEDC5V input, special signal acquisition for legacy projects
AJ65SBTB1-32KD32DECC 24 V, special common terminal layout
  1. Pure Transistor Output Modules (HACER)
ModeloAgujasBrief Specification
AJ65SBTB1-8T8HACERDC24V sink transistor, 0.5un por punto
AJ65SBTB1-8T18HACERHigh-speed sink transistor output
AJ65SBTB1-8TE8HACERSource transistor output
AJ65SBTB1-16T16HACERDC24V sink transistor
AJ65SBTB1-16T116HACERHigh-speed sink transistor output
AJ65SBTB1-32T32HACERDC24V sink transistor output
AJ65SBTB1-32T132HACERHigh-speed sink transistor output
AJ65SBTB1-32TE132HACERSource transistor output
  1. Mixed I/O Modules (DI+DO)
ModeloConfiguración de E/SBrief Specification
AJ65SBTB1-16DT8DI+8DOEntrada de 24 VCC + sink transistor output
AJ65SBTB1-16DT18DI+8DOHigh-speed version
AJ65SBTB1-16DT28DI+8DOPositive common version
AJ65SBTB1-16DT38DI+8DONegative common version
AJ65SBTB1-32DT16DI+16DO16-in 16-out, modelo estándar
AJ65SBTB1-32DT216DI+16DORevised common terminal spec
AJ65SBTB1-32DT316DI+16DOImproved revision
AJ65SBTB1-32DTE116DI+16DOSource transistor output
AJ65SBTB1-32KDT216DI+16DOSpecial common terminal
AJ65SBTB1-32KDT816DI+16DO12E/S V, special legacy project

Distinguish other family series (AJ65SBTB2 / AJ65SBTB32 / AJ65SBTC connector type, NOT SBTB1 series)

Frequently confused during procurement, not part of SBTB1 series, reference only

  1. AJ65SBTB2: Relay output R, analog A modules

AJ65SBTB2-8R, AJ65SBTB2-16R (salida de relé); AJ65SBTB2-8A, 16A analog

  1. AJ65SBTB32: Compact small terminal block

AJ65SBTB32-8DT / 8DT2, AJ65SBTB32-16DT / 16DT2, AJ65SBTB32-16DR (mixed relay)

  1. AJ65SBTC: Quick connector type (not screw terminals)

AJ65SBTC1-32D, AJ65SBTC1-32T, AJ65SBTC1-32DT, field plug wiring, different form factor from SBTB1

Notas de selección

  1. All AJ65SBTB1 series are discontinued. Not available for new project purchase, only stock / used units.
  2. Mismas dimensiones de montaje: same point count D/D1, T/T1, DT/DT modules support direct drop-in replacement with no program modification.
  3. Station type: Must select [Remote I/O Station] in GX Works parameter; fijado 1 occupied station.
  4. Analog modules are not in SBTB1 series: models AJ65SBT-64AD, AJ65SBT2B-64AD etc.