OMRON TL-Q5MC1-Z Inductive Proximity Sensor

Square standard type, no blindado, CC de 3 hilos, NPN NO, 2cable m, classic model of TL-Q series ✅ Model Code Explanation TL: Inductive proximity sensor Q: Square type (17×17mm) 5: Distancia de detección nominal 5 mm M: Built-in amplifier C: salida NPN (B = PNP) 1: Normalmente abierto (NO) (2 = Normalmente cerrado, CAROLINA DEL NORTE) z: Revised suffix for ...

  • Detalles del producto

Square standard type, no blindado, CC de 3 hilos, NPN NO, 2cable m, classic model of TL-Q series

✅ Explicación del código del modelo

TL: Inductivo sensor de proximidad

q: Square type (17×17mm)

5: Distancia de detección nominal 5 milímetros

METRO: Built-in amplifier

do: salida NPN (B = PNP)

1: Normalmente abierto (NO) (2 = Normalmente cerrado, CAROLINA DEL NORTE)

z: Revised suffix for domestic standard version

📌 Especificaciones clave

Principio de detección: Inductive type, for ferromagnetic metals (iron only); sensing distance drops sharply for copper, aluminum and other non-ferrous metals

Distancia de detección: 5 mm ±10%; practical setting distance 0~4 mm

Producción: Colector abierto NPN, Normalmente abierto (NO)

Tensión de alimentación: DC10~30V (nominal DC12-24V)

Load current: máx.. 200 mamá

Frecuencia de respuesta: 500 Hz

Hysteresis distance: ≤10% of rated sensing distance

Clase de protección: IP67

Temperatura ambiente: -25℃~+70℃ (sin formación de hielo ni condensación)

Alojamiento: PBT/ABS, dimension 17×17×28 mm

Cable: Standard 2m lead wire

Built-in protection: Protección contra polaridad inversa, surge absorption, protección contra cortocircuitos de carga

🧵 Wiring Definition (3-cable)

alambre marrón: CC+ (Potencia positiva)

cable azul: corriente continua(0V)

cable negro: salida NPN (conectar al terminal de entrada del PLC; one end of load to black wire, the other end to +24V)

When metal approaches → output turns ON, indicator light illuminates

📋 Cross-reference for the same series (para la selección & reemplazo)

TL-Q5MC2-Z: NPN Carolina del Norte

TL-Q5MB1-Z: PNPNO

TL-Q5MB2-Z: PNP Carolina del Norte

TL-Q5MD1/2: DC 2-wire type

⚠️ Notas de instalación (Critical for non-shielded type)

Diseño no blindado. Do not mount tightly against metal. Keep sufficient clearance on side and rear surfaces, otherwise false triggering or reduced sensing distance will occur. Suitable for independent mounting to detect metal targets on front face.

🛠️ Aplicaciones típicas

Equipment limit detection, cálculo, metal presence confirmation, conveyor positioning, machine tool fixture detection, compatible with digital inputs of Mitsubishi / PLC Siemens.

🔁 Domestic Replacement Reference

Square 17×17mm, NPN NO, no blindado, 5mm sensing proximity sensors from brands such as Hugong, Autonica.

Wiring Diagram for TL-Q5MC1-Z (NPN NO)

regla de cableado: Marrón = Positivo, Azul = Negativo, Black = Signal

Marrón: DC+ 24V

Azul: DC0V

Negro: salida NPN (when iron approaches → black wire pulled to 0V, indicator ON)

This is non-shielded type. Side and rear surfaces cannot be close to metal to avoid false trigger.

1) Drive intermediate relay (independent load test)

Brown → 24V+

Blue → 24V-

Black → One terminal of relay coil

The other terminal of relay coil → 24V+

✅ Iron detected: Relé energizado; No iron: Relay de-energized

2) Mitsubishi FX (sink input, más común)

Marrón: 24V+

Azul: 0V

Negro: X0 (X input terminal)

PLC COM terminal: Connect to 24V+

Sink input: X point detects 0V signal → input LED ON, matching NPN output

3) Siemens S7-200SMART / S7-1200 (DI sink wiring)

Marrón: 24V+

Azul: 0V

Negro: I0.0 (DI terminal)

Input common terminal 1M: Connect to 24V+

Nota: Siemens DI supports sink/source switching. NPN sensor requires 1M connected to +24V. If 1M is connected to 0V, it is for PNP sensors, this model cannot work.

4) OMRON CP1E/CP1H

Marrón: 24V+

Azul: 0V

Negro: Input terminal (p.ej. 0.00)

COM: Connect to 24V+

⚠️ Importante: Sensor power supply and PLC power supply must share the same GND (0V connected together), otherwise signal jitter and unstable detection.

  1. Quick Multimeter Test Method (Test before power-on to avoid damage)
  2. Alambrado: Brown to 24V+, Blue to 0V, black wire open-circuit
  3. No iron nearby: Voltage on black wire ≈ 24V, indicator OFF
  4. Iron block close to front face (≤4mm): Voltage on black wire ≈ 0V, indicator ON
  5. Iron removed: Back to 24V, indicator OFF

If the performance is inconsistent → sensor damaged or wiring error

III. Troubleshooting List for TL-Q5MC1-Z

FenómenoVerificar artículos
Indicator keeps ON all the time, no se puede restablecer① Non-shielded installation: surrounding metal too close; ② Iron powder/chips on sensing surface; ③ Black wire shorted to 24V; ④ Internal transistor breakdown
Indicator always OFF, no response even with iron① Brown & Blue reversed, voltage lower than 10V; ② Insufficient power capacity; ③ Broken wire; ④ Sensor burnt; ⑤ Target is non-ferrous metal (aluminum/copper barely detectable)
Indicator ON but PLC receives no input① Wrong PLC COM wiring (NPN cannot use COM to 0V); ② No common GND; ③ Faulty input channel; ④ Long cable & interference; ⑤ Exceed 500Hz response frequency for high-speed counting
Signal intermittent / jumping randomly① Metal interference around non-shielded sensor; ② Signal cable routed together with power cables for inverter/servo; ③ Large ripple of power supply; ④ Working distance over 4mm; ⑤ Mutual interference between adjacent proximity sensors
Burned shortly after power-on① Long-term reverse connection (reverse protection exists but not for continuous reverse voltage); ② Load short-circuit; ③ Supply voltage over 30V
  1. Instalación & Especificación de cableado (Non-shielded Priority)
  2. Distancia de detección: Practical working distance ≤4mm, avoid using the 5mm limit
  3. Espacio libre de montaje: Keep ≥15mm clearance between sensor side/rear and metal. Shielded type can be flush mounted.
  4. Multi-sensor side-by-side installation: Center distance ≥30mm between two TL-Q sensors to prevent mutual interference
  5. Cable: Standard 2m; If extended, Se recomienda cable blindado., shield grounded at single end; Do not run together with inverter / cables de servoalimentación
  6. Minimum iron target: Iron plate ≥17×17×1mm. Small workpiece causes unstable detection.
  7. Emergency Conversion Solution

If PLC only supports source input (COM connected to 0V) and only TL-Q5MC1-Z (PNP) disponible:

Use the NPN output to drive a DC24V miniature relay, then feed the relay dry contact to PLC input for signal isolation conversion.

Typical Application Cases of TL-Q5MC1-Z (NPN NO, No blindado, 5milímetros)

Core constraints: Only detect ferromagnetic metal; reserve clearance from surrounding metal for non-shielded type; response frequency 500Hz; NPN NO, signal ON when metal approaches

Caso 1: Workpiece arrival detection on conveyor line (más utilizado)

Scene: Cinta transportadora, tooling pallet assembly line, confirm iron/stainless steel workpiece arrives at station

Solución: Sensor mounted at side of station, small iron sheet installed on pallet as target. When pallet arrives and iron sheet enters 0–4mm sensing zone, NPN signal sent to PLC input

Lógica: Signal ON → stop conveyor, start clamping / machining / marking; Signal OFF → release

Notas:

Keep ≥15mm gap between conveyor frame metal and sensor side to avoid false trigger

Aluminio / copper workpiece cannot be directly detected, add iron target plate

PLC compatibles: Mitsubishi FX, Siemens S7-200SMART (sink input)

Caso 2: Origen & hard limit for machine slide / manipulator

Scene: Small CNC equipment, servo slide, transfer manipulator origin homing and overtravel protection

Solución: Iron target plate fixed on slide side, sensor installed at origin position. When slide returns home, trigger signal, PLC reset position and confirm origin completion. A second sensor can be used as overtravel limit.

Ventaja: Sin contacto, sin desgaste mecánico, better durability than mechanical limit switch under oil and iron chip environment

Risk reminder: Non-shielded type cannot attach to machine sheet metal, use bracket for floating installation. Iron chips accumulated on sensing surface will cause continuous false trigger, regular blow cleaning required.

Caso 3: Gear / rotary table speed detection & pulse measurement

Scene: Indexing table, motor driven gear, rotary fixture, speed measurement, stall detection, control sincrónico

Solución: Ferromagnetic gear teeth aligned to sensor, pulse output when teeth pass by. PLC high-speed counter collects pulses to calculate rotation speed and stall status.

Límite superior: máx.. 500Hz, suitable for low-speed rotary table (low RPM), not for high-speed spindle

Puesta en servicio: Gap between tooth top and sensor controlled at 2–3mm; tooth width cannot be too small to guarantee stable pulse.

Caso 4: Counting screws, nuts and stamping small parts

Scene: Vibratory feeder discharge, stamping blanking, hardware assembly machine, count ferrous parts

Solución: Sensor mounted beside vibratory feeder track, trigger one pulse when screw passes sensing zone. PLC accumulates count, alarm or stop machine when reaching set value.

Punto de dolor: Repeated triggering for fast passing small parts; add debounce delay / single pulse latch in PLC program

Limitación: Only ferrous parts; weak magnetic stainless steel has reduced sensing distance, reduce gap accordingly.

Caso 5: Cilindro / clamping fixture status feedback

Scene: Pneumatic clamping mechanism, fixture cylinder, confirm jaw clamping completion

Solución: Iron target plate fixed at end of cylinder piston rod, sensor installed at cylinder tail. When cylinder extends to clamp, iron sheet approaches sensor and signal ON, PLC confirms clamping finished and allows next action.

Comparación: Better than cylinder magnetic switch — no risk of magnet demagnetization; Desventaja: Extra metal target plate needed.

Caso 6: Low-level material alarm for ferrous bulk material silo

Scene: Iron powder, iron chips, steel ball silo, low material level alarm (lower limit detection)

Solución: Sensor installed at lower side wall of silo. When material level higher than sensor, metal material covers sensing surface, signal ON; when material level drops below sensor, signal OFF, PLC triggers low material alarm for feeding reminder.

Limitación: Only for ferromagnetic bulk material; clean sensing surface regularly under heavy dust environment.

Caso 7: Metal part presence confirmation & missing part check for packaging machine

Scene: Auto parts and hardware packaging machine, confirm iron gasket / iron clip is loaded

Solución: Sensor fixed at station. When packaging is in place and target detected, normal; no signal = missing part, trigger reject mechanism.

Notas: Packaging machine frame has lots of metal, isolate sensor with bracket, cable shielding required, keep away from inverter power cables.

Caso 8: Almacén automatizado & turnover pallet identification

Scene: Roller conveyor pallet positioning, iron sheet pre-installed on pallet bottom for station positioning and diverting

Solución: Sensor mounted above or side of roller frame. When pallet flows to target station, iron sheet triggers signal, PLC stops roller and starts scanning or transfer action.

Multi-sensor mounting: Center distance ≥30mm between two TL-Q sensors to avoid mutual interference.

Selección General & Field Troubleshooting Summary for this Model

  1. Producción: NPN NO, cannot directly connect to PLC source input (COM a 0V); intermediate relay conversion required
  2. Montaje: Sin descarga / no blindado, do not mount against metal, ≥15mm clearance reserved for side and rear metal
  3. Target object: Standard target 17×17×1mm iron plate; sensing distance decreases for stainless steel / weak magnetic stainless steel; aluminum and copper barely detectable
  4. Ambiente: IP67, splash-proof and dust-proof, no para inmersión a largo plazo; suitable for machine tool, transportador, stamping, packaging and light automation
  5. No apto para: Counting speed >500Hz, detección de larga distancia, aluminum/copper/plastic workpiece, flush mounting inside metal housing
  6. Complete Model List of TL-Q Series (17×17mm Square, No blindado, CC 24 V)

Basic specs: Sin descarga (no blindado), 5mm distancia de detección, 500Frecuencia de respuesta Hz, DC10~30V, IP67; suffix -Z = standard 2m cable for domestic market; -F-Z = oil-resistant cable; -R = robot flexible cable; ending digit 5 = anti-interference frequency variant

1) Tipo CC de 3 cables (Corriente principal, TL-Q5MC / TL-Q5MB)

salida NPN (C=NPN)

  1. TL-Q5MC1-Z: Normalmente abierto (NO) (tu modelo objetivo)
  2. TL-Q5MC2-Z: Normalmente cerrado (CAROLINA DEL NORTE)
  3. TL-Q5MC1-F-Z: Oil-resistant cable, NPN NO
  4. TL-Q5MC2-F-Z: Oil-resistant cable, NPN Carolina del Norte
  5. TL-Q5MC1-R: Robot flexible cable, NPN NO
  6. TL-Q5MC15: Different frequency anti-interference, NPN NO (for dense side-by-side installation)

salida PNP (B=PNP)

  1. TL-Q5MB1-Z: Normalmente abierto (NO)
  2. TL-Q5MB2-Z: Normalmente cerrado (CAROLINA DEL NORTE)
  3. TL-Q5MB1-F-Z: Oil-resistant cable, PNPNO
  4. TL-Q5MB2-F-Z: Oil-resistant cable, PNP Carolina del Norte
  5. TL-Q5MB15: Different frequency anti-interference, PNPNO

2) DC 2-wire type (TL-Q5MD, non-polar 2-wire)

  1. TL-Q5MD1-Z: Normalmente abierto (NO)
  2. TL-Q5MD2-Z: Normalmente cerrado (CAROLINA DEL NORTE)
  3. TL-Q5MD15: Different frequency anti-interference, NO
  4. TL-Q5MD1-R: Flexible robot cable, 2-wire NO

3) Smaller variant of same series (2mm distancia de detección, 8×9mm)

TL-Q2MC1: NPN NO, DC3-wire, 2mm distancia de detección, no NC version.

  1. Desglose del código del modelo (TL-Q5M C 1 -z)

TL-Q: Square non-shielded type

5: Sensing distance 5mm

METRO: Standard cable lead type

do: PNP; B: PNP; D: DC 2-wire

1: Normalmente abierto (NO); 2: Normalmente cerrado (CAROLINA DEL NORTE)

-z: Domestic standard 2m cable; -F-Z: Oil-resistant; -R: High-flex cable; ending 5: anti-interference different frequency

III. TL-N Series (Same outline, reference for larger sensing distance)

  1. TL-N5ME1/ME2: 25×25mm, 5milímetros, PNP
  2. TL-N7MD1/MD2: 7milímetros, DC 2-wire
  3. TL-N12MD: 12milímetros; TL-N20MD: 20milímetros
  4. Frequently Ordered Standard Models (2cable estándar m)
  5. NPN NO: TL-Q5MC1-Z (widely stocked)
  6. NPN Carolina del Norte: TL-Q5MC2-Z
  7. PNPNO: TL-Q5MB1-Z
  8. PNP Carolina del Norte: TL-Q5MB2-Z
  9. DC 2-wire NO: TL-Q5MD1-Z
  10. Notas de selección adicionales
  11. All models are non-shielded (sin descarga), ≥15mm clearance required between side/rear and metal, cannot mount directly on sheet metal.
  12. Only for ferromagnetic metal; sensing distance reduced for stainless steel; aluminum and copper are almost undetectable.
  13. When multiple sensors are installed side by side, select models ending with 5 (different frequency) to avoid mutual interference.

Anterior:

Deja una respuesta

Dejar un mensaje