Relé de seguridad Schmersal SRB301LC-24V

Model Code Breakdown SRB: Schmersal Safety control module of PROTECT series (safety relay) 301: modelo básico, dual-channel passive input, parada de emergencia / safety gate monitoring LC: Terminal de tornillo (0.25~2.5mm²), built-in glass fuse, no electronic fuse 24V: Universal supply voltage 24V AC/DC 101163475: Unique factory order number; Alternative order number: 101165472 Core Electrical Specifications 2.1 Fuerza ...

  • Detalles del producto

Desglose del código del modelo

  1. SRB: Schmersal Safety control module of PROTECT series (safety relay)
  2. 301: modelo básico, dual-channel passive input, parada de emergencia / safety gate monitoring
  3. LC: Terminal de tornillo (0.25~2.5mm²), built-in glass fuse, no electronic fuse
  4. 24V: Universal supply voltage 24V AC/DC
  5. 101163475: Unique factory order number; Alternative order number: 101165472
  6. Core Electrical Specifications

2.1 Fuente de alimentación

Tensión nominal: Dual-purpose 24V AC/DC

DC range: 20.4~28.8V DC (-15%/+20%)

CA 50/60 Hz: 20.4~26.4V AC (±10%)

Consumo de energía: 1.7W. / 1.9Virginia

Circuit fuse: 0.5A gG glass fuse (standard for LC version)

2.2 Input Circuit (Dual-channel Monitoring)

2 independent safety inputs A/B, compatible with passive contacts: botones de parada de emergencia, safety gate switches, magnetic safety switches

Equipped with wire break detection and ground fault detection; No cross-channel short-circuit detection

Max cable length: 2500metro (2.5mm² wire, loop resistance ≤40Ω)

2.3 Contactos de salida (Core for Safety Rating)

Main safety contacts: 3 Normalmente abierto (NO) forced-guided contacts, Detener categoría 0

Auxiliary signal contact: 1 Normalmente cerrado (CAROLINA DEL NORTE) fault feedback output (ERR diagnosis)

Contact protection fuses: 6A T for safety circuit; 2A T for auxiliary circuit

Max switching frequency: 5Hz; Contact resistance ≤100mΩ

  1. Safety Certification Ratings (Mechanical Safety Standards)

EN ISO 13849-1: pl y / Cat.4 (Highest mechanical safety level)

CEI 61508: SIL 3

Compliant standards: EN 60947-5-1, EN ISO 13850 (Parada de emergencia), EN 60204-1 Machinery Standard

  1. Mecánico & Parámetros ambientales

Montaje: Standard snap-on 35mm DIN rail mounting

Clase de protección: IP20 (For cabinet internal use only)

Temperatura de funcionamiento: -25℃ ~ +45℃

Alojamiento: Glass fiber reinforced flame-retardant plastic

Peso: Aprox.. 249gramo

Terminales: Screw-clamp type, suitable for 0.25~2.5mm² single/multi-strand wires

  1. Funciones & Aplicaciones típicas

5.1 Funciones principales

Dual-channel cross-check; All safety outputs cut off immediately upon single-channel wire break or ground fault

Process passive contact signals (parada de emergencia, safety gates, door interlock switches)

ERR fault output for external PLC / indicator light diagnosis

No automatic reset; Safety circuit must be reclosed to reset after fault clearance

5.2 Aplicaciones típicas

Safety circuit monitoring for machine tools, equipo de embalaje, líneas de producción automáticas, máquinas de moldeo por inyección, logistics sorting systems, lithium battery equipment and rail transit equipment

  1. Series Model Comparison (Referencia de selección)
Sufijo del modeloTipo de terminalFuse TypeNúmero de orden
LCScrew terminal 0.25~2.5m㎡Glass fuse101163475 (este modelo)
LCIPlug-in screw terminal 0.25~2.5m㎡Electronic fuseSeparate order number
LCI/7Plug-in cage clamp terminal 0.25~1.5m㎡Electronic fuseSeparate order number
LC/BCompatible with active safety light curtain signalsGlass fuse101177962
  1. Critical Risk Warnings
  2. Only applicable to passive contact safety switches. For safety light curtains (active AOPD), select model SRB301LC/B with suffix B
  3. Detener categoría 0: Main circuit power cut-off with instantaneous stop; Not suitable for equipment requiring delayed braking
  4. Forced-guided contacts shall not be connected in parallel for capacity expansion; External contactors are required for heavy loads
  5. Must be matched with Cat.4 dual-channel safety components; Single-channel wiring cannot achieve PL e rating

Full Output Contact Capacity Specifications of SRB301LC-24V (Número de pieza. 101163475)

  1. 3 Main Safety Normally Open Contacts (13-14 / 23-24 / 33-34)

1.1 Standard Rated Capacity for Resistive Loads

Max voltage: 250 VACACIONES

Corriente nominal: 6 A (AC-1 resistive)

Minimum reliable switching capacity: 10 V / 10 mamá (to avoid contact non-conduction)

1.2 Standard Utilization Categories (EN 60947-5-1)

AC-15 (Cargas inductivas: AC solenoid valves / contactores): 230 VACACIONES / 6 A

DC-13 (Cargas inductivas: DC solenoid valves): 24 VCC / 6 A

1.3 Peak / Short-term Parameters (Sólo como referencia, Not for Continuous Operation)

The datasheet states a short-term limit of 8A. For engineering continuous loads, sizing shall be based on 6A. Freewheeling diodes or varistors shall be connected in parallel for arc suppression on inductive loads.

1.4 Matched Protection Fuse

Standard 6A time-lag fuse for safety circuit; Higher rated fuses are strictly prohibited.

  1. 1 Auxiliary Normally Closed Fault Contact (41-42 ERR Diagnosis)

Capacidad nominal: 24 VCC / 2 A

Matched fuse: 2A time-lag fuse; Only for small signal loops such as PLC feedback and fault indicator lights, not for heavy loads.

  1. Selección de clave & Operation Restrictions
  2. Parallel connection of the three safety contacts for capacity expansion is forbidden. External safety contactors must be used for loads exceeding 6A.
  3. Detener categoría 0 with instantaneous cut-off, suitable for cutting off main contactor coil circuits via emergency stops and safety gates.
  4. Arc suppression circuits are mandatory for inductive loads (válvulas solenoides, bobinas), otherwise contact service life will be drastically shortened.
  5. Derating is required at ambient temperature above 40℃; Max switching frequency is 5Hz.

Official Standard Response & Delay Specifications of SRB301LC-24V (101163475)

  1. Trip Response Time (Cut-off triggered by emergency stop / safety gate, core safety index)
  2. Maximum rated dropout delay specified in official manual: ≤50 ms
  3. Typical measured value of SRB301LC/B with identical architecture: ≤25 ms (Total breaking time of main safety contacts after dual-channel fault or emergency stop input disconnection)

> Nota: 50ms is the conservative upper limit from the manufacturer. Under normal engineering operating conditions, cut-off is generally completed within 20~30ms, complying with Stop Category 0 emergency stop safety regulations.

  1. Make Delay (Safety circuit recovery, contact closing)
  2. Make delay for manual start via reset button: ≤20 ms (Output energized after safety gate closed and reset button pressed)
  3. Make delay under auto-start mode: ≤300 ms (Scenario without reset button, auto-energization upon power-up)
  4. Typical basic make delay stated in general datasheets: ≈30 ms
  5. Supplementary Key Notes
  6. This response time covers the total duration of dual-channel input logic detection plus internal electromechanical relay breaking, not merely mechanical contact actuation time.
  7. Wire break, cross-channel short-circuit and ground fault detection also cut off safety outputs within ≤50ms.
  8. Compared with LC/B light curtain version with trip time ≤25ms, the upper limit for SRB301LC-24V (standard passive contact model) is extended to 50ms. 50ms shall be adopted for safety distance calculation in SISTEMA safety assessments.
  9. Upper switching frequency limit: 5Hz; Minimum full cycle make-break period: 200EM. High-frequency operation is not allowed.
  10. Reference for Safety Calculation During Selection

If the equipment requires total shutdown reaction time (cambiar + relé + contactor), adopt the conservative value of 50ms for this relay to calculate safety distance.