Model Code Breakdown Segment Code Definition A9 A9 Product family code for Acti9, Schneider’s standard low-voltage distribution series F F Type code for iC65N miniature circuit breaker (MCB); F=iC65, K=iC65N-K, V=Vigi iC65 18 18 Internal item code for standard iC65N version 2 2 Pole quantity: 2PAG (2-polo); 1=1P, 2=2P, 3=3P, 4=4P 10 10 Corriente nominal ...

  • Detalles del producto
  1. Desglose del código del modelo
SegmentoCódigoDefinición
A9A9Product family code for Acti9, Schneider’s standard low-voltage distribution series
FFType code for iC65N disyuntor miniatura (MCB); F=iC65, K=iC65N-K, V=Vigi iC65
1818Internal item code for standard iC65N version
22Pole quantity: 2PAG (2-polo); 1=1P, 2=2P, 3=3P, 4=4P
1010Rated current code for 10A; 01=1A, 02=2A, 04=4A, 06=6A, 10=10A, etc..

Full Model Definition: Schneider Acti9 iC65N standard miniature circuit breaker, 2-polo, curva C, 10A

  1. Especificaciones técnicas básicas
CategoríaParámetros detalladosEstándares & Certificaciones
Basic Ratings• Family: Acti9 iC65NCEI 60898-1
• Type: Thermal-magnetic MCBES 10963.1
• Postes: 2PAGCCC, CE, CCS Approval
• Rated current (En): 10A @30°C
• Tripping curve: curva C (5~10×In)
• Capacidad de ruptura: 6kA@400V CA, 10kA@380~415V AC, 20kA@220~240V AC, 36kA@12~133V AC
• Rated operational voltage (ue): 400V CA 50/60 Hz
• Rated insulation voltage (interfaz de usuario): 500V y
• Rated impulse withstand voltage (árbitro): 6kV
Mecánico & Rendimiento eléctrico• Mechanical endurance: 20,000 operacionesCEI 60947-2
• Electrical endurance: 10,000 operaciones
• Current limiting class: Clase 3
• Disconnector function: Disponible
• Operación: Toggle handle
• Status indication: ON/OFF contact position marker
• Cable capacity: Solid wire 1~25mm², flexible wire 1~16mm²
• Strip length: 14milímetros
• Tightening torque: 2.5Nuevo Méjico
Dimensiones físicas• Mounting: DIN rail mountCEI 60529
• Width: 36milímetros (4×9mm modular pitch)
• Height: 94milímetros
• Depth: 78.5milímetros
• Peso: 206gramo
• Ingress protection: IP20
Condiciones ambientales• Temperatura de funcionamiento: -35°C ~ +70°CCEI 60068-1
• Temperatura de almacenamiento: -40°C ~ +85°C
• Relative humidity: 95% @55°C
• Pollution degree: Clase 3
• Damp heat resistance: Grade 2
Sustainability Features• Green Premium certified productChina Green Design Product Certification
• Compliant with EU RoHS Directive
• SVHC-free per REACH regulation
• Mercury-free construction
• Product lifecycle carbon footprint: 4kg CO₂ equivalent
  1. Full Part Number List (iC65N 2P C Curve Range)
Número de pieza.DescripciónCorriente nominal
A9F18201iC65N 2P C1A1A
A9F18202iC65N 2P C2A2A
A9F18203iC65N 2P C3A3A
A9F18204iC65N 2P C4A4A
A9F18206iC65N 2P C6A6A
A9F18210iC65N 2P C10A10A
A9F18213iC65N 2P C13A13A
A9F18216iC65N 2P C16A16A
A9F18220iC65N 2P C20A20A
A9F18225iC65N 2P C25A25A
A9F18232iC65N 2P C32A32A
A9F18240iC65N 2P C40A40A
A9F18250iC65N 2P C50A50A
A9F18263iC65N 2P C63A63A

Full series coverage: 1P/2P/3P/4P, B/C/D tripping curves, rated current from 1A to 63A

  1. Referencia entre marcas & Opciones de reemplazo

4.1 In-brand Schneider Replacements

Original PNReplacement PNDiferencia de especificación
A9F18210 (iC65N 2P C10A)A9F19210 (iC65H 2P C10A)Mayor capacidad de rotura: up to 15kA@400V vs original 10kA
A9F18210A9F20210 (iC65L 2P C10A)Industrial grade, enhanced current-limiting performance
A9F18210A9F75210 (iDPNa 2P C10A)Compact 1P+N design with only 18mm width

4.2 Cross-Brand Equivalent List

SchneiderTEJIDOsiemensDelicioso
A9F18210 (iC65N 2P C10A)S201-C10 (2PAG)5SY6210-7CCHDBE-63 C10 2P
Capacidad de ruptura:6kA@400VCapacidad de ruptura:6kA@400VCapacidad de ruptura:6kA@400VCapacidad de ruptura:6kA@400V
curva C (5~10×In)curva C (5~10×In)curva C (5~10×In)curva C (5~10×In)
  1. Ámbito de aplicación & Casos de la industria

5.1 Aplicaciones recomendadas

Campo de aplicaciónUso típicoVentajas de la selección
Civil BuildingsOvercurrent protection for lighting & socket circuits in residential and commercial buildingsC-curve matches general loads; Protección IP20, quick DIN installation
Controles IndustrialesPower protection for small motor control loops and PLC power supplyClass3 current limiting, fast reliable short-circuit protection
Public InfrastructureSecurity alarm, fire alarm and low-voltage auxiliary systemsAmplio rango de temperatura de funcionamiento (-35°C~70°C), stable in harsh environments
Centro de datosBranch circuit protection for server cabinets & network equipmentLong mechanical/electrical service life for frequent switching
Nueva energíaOutput-side protection for PV inverters and energy storage branch circuitsHigh breaking capacity plus certified disconnector safety function

5.2 Non-Recommended Application Scenarios

Direct-on-line large motors: select D-curve or motor-specific MCB instead

Frequently switched heavy inductive loads: configure contactor + relé de sobrecarga térmica

circuitos CC: adopt iC65-DC series with part numbers starting with A9F8

High altitude (>2000metro): derate rated current or specify altitude-adapted dedicated models

5.3 Casos de aplicación típicos

Caso 1: Lighting System of Commercial Complex

Solicitud: Branch protection for public area lighting circuits in shopping mall

Configuración: A9F18210 (2P C10A) for each 10A lighting feeder

Outcome: Sobrecarga & protección contra cortocircuitos; paired with Vigi residual current accessory A9V52210 for earth leakage protection, complying with GB 50054 electrical code for buildings

Caso 2: Control Circuit for Automated Production Line

Solicitud: Power protection for PLC input modules & secondary control loops

Configuración: A9F18210 as backup protection of control transformer secondary side

Ventaja: Excellent current limiting cuts off short-circuit instantly to safeguard PLC modules against damage

  1. Solución de problemas de fallas comunes
Fault SymptomRoot CauseRemedial Action
Frequent unwanted tripping1. Circuit overload1. Reduce connected load or upgrade higher rated breaker
2. Wiring short-circuit2. Inspect cable insulation and eliminate short fault
3. Mismatched tripping curve3. Replace with matched curve (p.ej. D-curve)
4. Excessive ambient temperature4. Improve cabinet ventilation to lower surrounding temp
Unable to close ON1. Not reset after fault trip1. Toggle handle fully OFF then reclose ON
2. Internal mechanism jamming2. Inspect mechanical parts or replace breaker if damaged
3. Loose terminal wiring3. Retighten terminals to 2.5N路m torque
4. Persistent downstream short-circuit4. Clear short-circuit fault before re-energizing
Incorrect handle position indication1. Damaged position indicator component1. Inspect indicator window and replace unit as needed
2. Failed internal linkage mechanism2. Contact Schneider after-sales service
  1. Cumplimiento de envíos aéreos & Certificaciones

7.1 Cumplimiento del transporte aéreo

Product construction: Sin batería de litio incorporada / supercondensador, classified as general electrical equipment

Shipping classification: Mercancías no peligrosas, compliant with IATA DGR Clause 9

Packaging requirement: Standard industrial carton to avoid transit mechanical damage

7.2 Main Certification Summary

Certificate TypeNúmero de certificado.Valid Application Region
CCC Approval2.02001E+15Domestic sales & installation in China
Certificados CE0081/CEUE & European Economic Area
CCS Marine ApprovalCCS-ZY-2021-001Onboard marine electrical systems
RoHS ComplianceCompliant with Directive 2011/65/EURestricted hazardous substances per EU environmental regulation
  1. Reglas de selección rápida & Mnemonic

Mnemonic (Engineering Summary)

Remember PN A9F18210: 2P C10 rating confirmed

Six kiloamp breaking, safe for lamp and socket conformation

Standard Acti9 range, easy DIN rail fixation

C-curve trips at five-to-ten In, dual protection from overload & short condition

Quick Look-up Rules

  1. Pole identification: 4th digit of PN = pole count (1=1P,2=2P,3=3P,4=4P)
  2. Current reading: Last two digits denote rated amp (01=1A,06=6A,10=10A,63=63A)
  3. Curve selection: C=general-purpose standard; B=precision electronics; D=heavy-duty motor loads
  4. Breaking capacity code: N=6kA, H=10kA, L=15kA @400V AC