Servoaccionamiento Schneider LXM32MD72N4

LXM32: Lexium32 series servo M: Multi-fieldbus version (Compatible con CANopen, built-in encoder acquisition and positioning function) D72: Peak output current 72A, continuous 24A N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply Core Electrical Specifications Item Specification Power Supply 3-phase AC 208~480V, 50/60Hz Rated Power 400V class: 7kilovatios; 230clase V: 5kW Continuous Output Current 24A (8kHz carrier ...

  • Detalles del producto

LXM32: Lexium32 series servo

METRO: Multi-fieldbus version (Compatible con CANopen, built-in encoder acquisition and positioning function)

D72: Peak output current 72A, continuous 24A

N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply

Especificaciones eléctricas básicas

ArtículoEspecificación
Fuente de alimentación3-phase AC 208~480V, 50/60Hz
Potencia nominal400clase V: 7kilovatios; 230clase V: 5kilovatios
Continuous Output Current24A (8kHz carrier frequency)
Corriente de salida máxima72A, sustainable for 5s
Filtro EMC incorporadoStandard integrated
Speed Loop BandwidthUp to 1600Hz, alta respuesta dinámica
Frecuencia portadora8kilociclos
DC Bus Undervoltage Threshold350V (400clase V)

Comunicación & E/S

  1. Bus de campo: CANabierto (LXM32M model, different from pulse-type LXM32A)
  2. Digital: Multiple 24VDC discrete inputs including 2 high-speed capture CAP ports; salidas digitales
  3. Interfaz del codificador: Supports SinCos and EnDat, compatible with BSH/BMH servo motors
  4. Interfaces: RJ45 debug port, detachable color-coded terminals for convenient cabinet wiring and maintenance

Matching Motors

Compatible with BSH / BMH 400V class servomotores of Lexium32 series. Typical match: 140-flange BSH high-torque motor, continuous torque up to 27.8N·m, peak 90.2N·m, common speed 3000rpm.

Escenarios de aplicación

Maquinaria de embalaje, machine tool feed axes, CNC cutting, maquinaria textil, material handling conveying, multi-axis synchronization equipment; suitable for automated production lines requiring CANopen bus multi-axis linkage and high dynamic positioning.

Instalación & Ambiente

Book-style cabinet mounting, vertical installation on control cabinet DIN rail

Categoría de sobretensión: Clase III

Max leakage current: 30mamá

Recommended wire gauge for power terminals: 3mm², tightening torque 0.5N·m

Falla & Notas de puesta en servicio

  1. Common Alarms: Overcurrent OC, Overvoltage OV, Undervoltage UV, Fallo del codificador, Overheat OH
  2. Software de puesta en marcha: Así que muévete, supports online parameter configuration, oscilloscope sampling and automatic inertia tuning
  3. For high-power working conditions, it is recommended to install an external 1mH line reactor to reduce harmonics and incoming current surges

Reemplazo & Selection Remarks

Pulse version of the same series: LXM32AD72N4 (sin CANopen, pulse-direction control)

Alternativa de actualización: Schneider Lexium28 series; comparable competitors: Siemens V90, Mitsubishi MR-J4

Nota: LXM32 is a discontinued legacy series. Lexium28 is preferred for new projects; stock or second-hand units are available only for spare part projects.

Referencia del código HS

85011099 (servoaccionamiento, re-verify customs classification before customs declaration)

LXM32MD72N4 SoMove Power-on Commissioning Parameter Template

Aplicable: Lexium32M 7kW CANopen bus servo, matched with BSH/BMH 400V motors; SoMove software, expert mode password 696969

Pre-operation: Complete hardware wiring including power cable, codificador, parada de emergencia, freno, CAN bus and 24V control power supply; perform no-load jog test first, then auto-tune under load; save parameters to EEPROM after modification.

  1. Configuración básica (Simply Start Wizard Page)
Nombre del parámetroParameter IDConfiguración recomendadaDescripción
Control SourceDEVcmdInterfBus de campoLXM32M CANopen positioning mode; temporarily change to Terminal for local jog
Motor SelectionMotor SelectionSelect corresponding BSH/BMH modelDrive loads motor nameplate parameters automatically; must not select incorrectly
Tipo de codificadorENC1_typeSinCos / EnDatSelect according to motor encoder; EnDat absolute encoder requires battery module
Frecuencia portadoraPWM_Freq8kilociclosDefault for LXM32MD72N4, not recommended to increase
Dirección de rotaciónInvertDirOfMoveAPAGADO (Por defecto)Set to ON if rotation direction reversed; power cycle required after change
Auto Enable on Power-upIO_AutoEnable0 (Disabled)Disabled during commissioning; can be set to 2 for mass production after safety assessment
  1. Axis Limit Parameters (Axis Configuration → Limitations)
Nombre del parámetroParameter IDConfiguración recomendadaDescripción
Corriente de salida máximaCTRL_I_maxCorriente nominal del motorLimit maximum torque to protect machinery; cannot exceed 72A peak of drive
Max Motor SpeedM_n_maxMotor rated speedTypical 3000rpm for BSH/BMH, do not exceed nameplate
Positive Software LimitPOS_LIM_PUser unitInside mechanical hard limit to prevent overtravel
Negative Software LimitPOS_LIM_NUser unitSame as positive limit
E-Stop DecelerationQS_DecCostumbreDeceleration triggered by emergency stop, safety related
  1. E/S & Safety Parameters (Axis Configuration → IO)
Nombre del parámetroParameter IDConfiguración recomendadaDescripción
Positive Limit ContactIOsigLIMPNC normalmente cerradoDefault for safety standards; set to NO if using normally open sensors
Negative Limit ContactIOsigLIMNNC normalmente cerradoIgual que arriba
Brake Release DelayBRK_AddT_Release100EMBrake motor: wait for brake release before movement after servo enable
Brake Apply DelayBRK_AddT_Apply50EMDelay brake output after servo disable to prevent axis falling
Restablecimiento de fallasIO_FaultResetAssign DI terminalExternal reset button
  1. Position Scaling (Escalada, Core for Positioning Projects)

User units per revolution, ejemplo: 10mm per revolution for lead screw, modify as required

| Nombre del parámetro | Parameter ID | Example Value | Descripción |

| —| —| —| —|

| Position Numerator | ScalePOSnum | 10 | Numerator of travel per revolution |

| Position Denominator | ScalePOSdenom | 1 | Denominador; ejemplo: 10mm/rev → 10/1 |

| Velocity Scaling | ScaleVELnum / ScaleVELdenom | Follow position | Velocity unit: mm/s |

| Acceleration Scaling | ScaleACCnum / ScaleACCdenom | Follow position | Acceleration unit: mm/s² |

Raw encoder resolution: 16384count/rev for SinCos motors

  1. Servo Loop Gains (Tuning Page, No-load → On-load Auto-tune)

Prioritize SoMove automatic inertia identification + auto-tune, then fine tune

| Nombre del parámetro | Parameter ID | Initial Recommendation | Tuning Logic |

| —| —| —| —|

| Position Loop Gain | CTRL_Kp_pos | 3~8 | Higher for stiff mechanics; reduce if oscillation occurs |

| Speed Loop Gain | CTRL_Kp_vel | 80~150 | Base response, reduce for mechanical resonance |

| Speed Loop Integral Time | CTRL_Ti_vel | 8~20ms | Smaller value improves steady-state error, prone to oscillation |

| Velocity Feedforward | CTRL_Kff_vel | 0.6~0.9 | Reduce position following error |

| Acceleration Feedforward | CTRL_Kff_acc | 0~0.3 | For high-speed start-stop; large value causes impact |

| Low-pass Filter | CTRL_FiltVel | 500~1000Hz | Suppress resonance; lower filter frequency at resonance point |

  1. CANopen Fieldbus Parameters (Key for LXM32M)
Nombre del parámetroParameter IDConfiguración recomendadaDescripción
CAN Node IDCAN_NodeID1~127No duplicate for multi-axis, consistent with PLC
CAN Baud RateCAN_Baud500kbpsCommon setting; use 250kbps for long distance, terminal resistor ON at both bus ends
PDO MappingPDO ConfigurationStandard positioning PDOTarget position, palabra de estado, actual position, fault code
Fieldbus Control ModeProfile ModeProfile PositionControl de posicionamiento; select Profile Velocity for speed axis
Profile Acc/DecPRO_ACC / PRO_DECMechanical dependentUnidad: user unit/s
Quick Stop RampPRO_QSDecIndependent E-stop decelerationDeceleration upon bus failure
  1. Homing Parameters
Nombre del parámetroParameter IDDescripción
Homing ModeHOM_mode0~35 optional; común: limit homing, index homing, direct origin setting for absolute encoder
Homing VelocityHOM_VelBaja velocidad, 50~200 user unit/s
Homing Search VelocityHOM_Vel_SearchSlightly higher than homing speed
Homing OffsetHOM_OffsetMechanical origin offset
  1. Escucha & Fault Log

Fault Buffer: Stores latest 16 alarms for troubleshooting of OV/OC/OH/ENC faults

Osciloscopio: Sample target position, actual position, following error, bus voltage, motor current for resonance and tuning analysis

Ahorrar: Device → User Functions → Save parameters to EEPROM; back up local project as .cxm file

Complete Power-on Commissioning Procedure (Matching Parameter Template)

  1. Connect PC to drive RJ45 debug port via SoMove, establish communication and read factory parameters
  2. Run Simply Start wizard, select motor model and confirm encoder type
  3. Configure limit, brake and I/O terminal definition
  4. Set position scaling and mechanical transmission ratio
  5. Set CANopen Node ID, baud rate and configure PDO
  6. Prueba sin carga: Enable, jog, verify rotation direction, limit and brake logic
  7. On-load test: Run Auto-tune inertia identification to generate base gains
  8. Observe following error and oscillation via oscilloscope, fine-tune 3-loop gains and filter
  9. Homing test, point positioning test, acceleration/deceleration test
  10. Save parameters to EEPROM and export .cxm backup file

Commissioning Precautions

  1. Expert mode password 696969, enter expert mode to modify advanced parameters
  2. Auto-tune must be performed with actual load; parameters tuned under no-load easily oscillate under load
  3. Incorrect brake timing will directly cause axis falling; test brake function without load during first commissioning
  4. Autobús CANabierto: Enable terminal resistor only at the first and last device on bus, disable for intermediate nodes
  5. For high-power LXM32MD72N4, check wiring of line reactor and braking resistor before first power-up

Optional Extended Parameters

Resistencia de frenado: BRK_R, BRK_P for external braking resistor resistance/power rating, bus overvoltage protection

Entrada analógica: AI scaling for analog speed mode (not commonly used for CANopen projects)

Schneider Lexium32 (LXM32) Full Series Drive Model List

3 main branches: LXM32C (Basic Analog) / LXM32A (Legumbres + Modbus) / LXM32M (CANopen bus type, LXM32MD72N4 belongs to this branch)

Suffix explanation:

M2: Single-phase 200~240VAC; N4: 3-phase 208~480VAC

Dxx: Number after D = peak current (A), continuous current = 1/3 of peak current

Estado: Full series discontinued, only available on spare parts market

  1. LXM32M (Tipo de bus CANopen, High Priority, includes LXM32MD72N4)

Single-phase 200~240V (Suffix M2)

ModeloCorriente máximaCorriente Continua230V Rated Power
LXM32MD12M212A4A0.75kilovatios
LXM32MD18M218A6A1.0kilovatios
LXM32MD30M230A10A1.6kilovatios
LXM32MD42M242A14A2.5kilovatios
LXM32MD57M257A19A3.5kilovatios

3-phase 208~480V (Suffix N4, your series)

ModeloCorriente máximaCorriente Continua400V Rated Power
LXM32MD12N412A4A0.9kilovatios
LXM32MD18N418A6A1.8kilovatios
LXM32MD30N430A10A3kilovatios
LXM32MD42N442A14A4.5kilovatios
LXM32MD57N457A19A5.5kilovatios
LXM32MD72N472A24A7kilovatios
LXM32MD85N485A32A9kilovatios
  1. LXM32A (Pulse/Direction + Modbus, sin CANopen, same power rating)

Single-phase M2

LXM32AD12M2, LXM32AD18M2, LXM32AD30M2, LXM32AD42M2, LXM32AD57M2

3-phase N4

LXM32AD12N4, LXM32AD18N4, LXM32AD30N4, LXM32AD42N4, LXM32AD57N4, LXM32AD72N4, LXM32AD85N4

  1. LXM32C (±10V analog basic model, speed/current control only, no positioning)

Single-phase M2

LXM32CD12M2, LXM32CD18M2, LXM32CD30M2, LXM32CD42M2, LXM32CD57M2

3-phase N4

LXM32CD12N4, LXM32CD18N4, LXM32CD30N4, LXM32CD42N4, LXM32CD57N4, LXM32CD72N4, LXM32CD85N4

  1. Matching Motor Series (BSH / BMH for Lexium32)
  2. BSH Motors: SinCos encoder, single-turn/multi-turn, IP50; flange sizes 55/70/100/140mm
  3. BMH Motors: EnDat absolute encoder, multi-turn, IP65; flange sizes 55/70/100/140/190mm
  4. Lista de accesorios (General for LXM32)

VW3M8101: Resistencia de frenado

VW3M8D10: Encoder battery box (for EnDat multi-turn BMH motors)

VW3M8102: Line reactor

VW3M8200: Pre-made I/O terminal cable

VW3M8300: CANopen bus cable

VW3M8400: Cable de alimentación del motor

VW3M8500: Cable codificador

Branch Comparison Overview

Serie de modelosControl InterfaceFunción de posicionamientoBus de campoAplicación típica
LXM32C±10V Analog❌ No positioningModbusPure speed control
LXM32APulse+Direction✅ Point positioningModbusPulse PLC control
LXM32MCANabierto✅ Electronic gear / Punto / HomingCANabiertoMulti-axis bus synchronization (LXM32MD72N4)

Consejos de selección:

  1. Same Dxx model: LXM32A and LXM32M have identical hardware power rating, differ only in firmware communication functions
  2. LXM32MD85N4 is the largest model in this series, 9kilovatios
  3. New project replacement: Lexium28 series; only stock/second-hand units available for spare part projects.