Ventilador con filtro Schneider NSYCVF165M230PF

Model Code Definition Breakdown of NSYCVF165M230PF Code Segment Meaning Description NSY Product series prefix General mark for Schneider ClimaSys cabinet cooling products CV Sub-series ClimaSys CV series standard cabinet filter fan F Product type Fan 165 Air flow rate Rated airflow 165m鲁/h at 50Hz, 193m鲁/h at 60Hz M Mounting type Side mounting on cabinet 230 ...

  • Detalles del producto

Definición del código del modelo

Breakdown of NSYCVF165M230PF

Segmento de códigoSignificadoDescripción
NSYProduct series prefixGeneral mark for Schneider ClimaSys cabinet cooling products
CVSubserieClimaSys CV series standard cabinet filter fan
FProduct typeAdmirador
165Air flow rateRated airflow 165m鲁/h at 50Hz, 193m鲁/h at 60Hz
METROTipo de montajeSide mounting on cabinet
230Tensión nominal230V y
PAGProtection configurationEquipped with pre-filter
FAir outlet configurationFitted with front grille
  1. Parámetros de especificación principales
CategoríaÍndice técnicoObservaciones
Parámetros básicos
Tipo de productoCabinet Filter FanClimaSys CV series, IP54 protection
Air Flow165m³/h (50Hz) / 193m³/h (60Hz)Measured with standard G2 filter
Rango de voltaje175~253V ACCompatible with most 230V power grids worldwide
Tensión nominal230V 50/60HzDual frequency compatibility
Parámetros eléctricos
Fuerza16.3W. (50Hz) / 14.3W. (60Hz)Alta eficiencia energética
Actual0.12A (50Hz) / 0.94A (60Hz)Low power consumption design
ConexiónFaston terminal + power cableFácil instalación
Parámetros físicos
External Dimension268×248×104mmHeight×Width×Depth
Cutout Size223×223mmStandard cabinet mounting hole
MaterialAir outlet grille: ASA+PC thermoplasticAnti-aging, grey RAL 7035
Peso1.14kilosStable installation, low resonance
Parámetros de rendimiento
Clase de protecciónIP54Dustproof and splashproof, suitable for outdoor cabinets
Tipo de rodamientorodamiento de bolasLarga vida útil, bajo ruido
Nivel de ruido50~51dBQuiet operation, applicable near office areas
Max Static Pressure50Pa (0m³/h)Resists certain air resistance
Parámetros ambientales
Temperatura de funcionamiento-20℃~60℃Amplio rango de temperatura para entornos hostiles
Temperatura de almacenamiento-40℃ ~ 70 ℃Reliable transportation and storage
Proceso de dar un títuloREACH, RoHSCompliant with environmental standards
  1. Full Series Model List
ModeloAir Flow(m³/h)VoltajeConfiguraciónCutout Size(milímetros)External Size(milímetros)
NSYCVF38M230PF39230V yGrille + Filter117×117137×137×85
NSYCVF54M230PF54230V yGrille + Filter148×148170×170×92
NSYCVF85M230PF85230V yGrille + Filter170×170190×190×95
NSYCVF165M115PF165/193115V yGrille + Filter223×223268×248×104
NSYCVF165M230PF165/193230V yGrille + Filter223×223268×248×104
NSYCVF165M24DPF165/19324En DCGrille + Filter223×223268×248×104
NSYCVF300M230PF300/350230V yGrille + Filter262×262300×300×110
NSYCVF550M230PF550/650230V yGrille + Filter336×336380×380×120
NSYCVF850M230PF838/980230V yGrille + Filter400×400450×450×130
NSYCVF850M400PF838/980400V yGrille + Filter400×400450×450×130
  1. Cross-brand Replacement Comparison
MarcaModeloAir Flow(m³/h)VoltajeClase de protecciónCutout Size(milímetros)Ventajas de reemplazo
Rittal323920074/87230V yIP54148×148Tool-free quick installation
Rittal3241700160/190230V yIP54223×223High-efficiency energy saving series
StegoFK 66230165/193230V yIP54223×223Integrated temperature control, intelligent start-stop
Pfannenberg1041230160/190230V yIP54223×223Long filter service life, low maintenance frequency
RS PRO130-853165/193115V yIP54223×223Rentable, sufficient stock
  1. Solución de problemas de fallas comunes & Mantenimiento
Fenómeno de fallaPosibles causasPasos de inspecciónMaintenance Solution
Fan not running1. Power disconnected1. Test power voltage1. Reconnect power supply
2. Motor burnout2. Check motor winding resistance2. Replace identical motor
3. Stuck bearing3. Manually rotate fan blade3. Clean and lubricate bearing
4. Control circuit failure4. Inspect loose Faston connector4. Reconnect or replace connector
Reduced airflow1. Clogged filter1. Check filter blockage1. Clean or replace G2 filter
2. Dust accumulated on blades2. Inspect blade cleanliness2. Clean blades with soft brush
3. Subtensión3. Measure operating voltage3. Adjust voltage to rated value
4. Rotación inversa4. Verify mounting direction4. Reinstall fan outward air discharge
Abnormal noise1. Worn bearing1. Locate noise source1. Replace bearing or whole fan
2. Unbalanced fan blade2. Check blade deformation and attachments2. Correct balance and clear debris
3. Loose mounting3. Tighten mounting screws3. Fasten all screws
4. Vibration resonance4. Observe cabinet vibration4. Add shock pad or adjust position
Protección contra sobrecorriente1. Motor short circuit1. Test insulation resistance1. Replace motor
2. Excessive bearing friction2. Check bearing flexibility2. Lubricate or replace bearing
3. Sobretensión3. Measure operating voltage3. Restore normal voltage
  1. Entorno de aplicación & Industry Cases

Escenarios aplicables

  1. Automatización Industrial: Cooling for PLC, inverter and servo drive cabinets
  2. Sistema de energía: Heat dissipation for outdoor ring main units, box substations and charging pile control boxes
  3. Telecommunication: Ventilation for base station cabinets, optical distribution boxes and data center server cabinets
  4. Rail Transit: Temperature control for signal boxes and converter cabinets
  5. Nueva energía: Cooling for photovoltaic inverters and energy storage control cabinets

Non-recommended Scenarios

  1. Corrosive atmosphere such as chemical and marine environment (anti-corrosion model required)
  2. Heavy dust sites like mines and cement plants (extra pre-filter needed)
  3. Submerged or long-term rain exposure (IP54 only splash-proof)
  4. Fully sealed space without air inlet circulation

Casos típicos

Automobile Factory: Installed on welding robot cabinets, failure rate reduced by 70% against high temperature

Power Grid Company: Eliminated switch misoperation, equipment service life extended 3 veces

Centro de datos: Hierarchical cooling with air conditioner, energy consumption cut by 20%

  1. Consejos de selección & Avoidance Guide

Quick Calculation Rule

  1. Airflow demand = Cabinet volume × (8~10) m³/h, suitable for 16~20m³ cabinet
  2. Voltage selection: 230V for general industry, 115V for North America, 24V for DC system
  3. Mounting mark: M=side, MF=top, FB=bottom

Operation Warnings

  1. Inspect and replace G2 filter every 3 months to avoid airflow drop and motor overload
  2. Keep air outlet outward and match air inlet for effective ventilation
  3. Adopt cabinet air conditioner when external temperature is 5℃ higher than internal temperature
  4. Restrict voltage fluctuation within ±10% to guarantee service life
  5. Confirm UL, CE and other certifications for export use
  6. Order Information

Modelo: NSYCVF165M230PF

Nro. de orden: NSYCVF165M230PF (Global unified)

Package Contents: 1 axial fan motor, 1 cutting template, 1 pre-filter, 1 air outlet grille, 1 power cable, 2 protective grilles

Delivery Lead Time: 3-5 working days for standard stock items