Siemens 3RQ2000-1BW00 Coupling Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Siemens 3RQ2000-1BW00 Coupling Relay - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Siemens 3RQ2000-1BW00 Coupling Relay

Industrial coupling relay of Siemens SIRIUS series, equipado con 2 contactos de cambio, wide voltage range 24-240V AC/DC and screw terminals. It serves as a replacement for 3TX7002-1CB00 and 3RS1800-1BW00, and is designed for PLC signal isolation and control circuit coupling. Model Code Interpretation Model Segment Meaning 3RQ Product family code for Siemens SIRIUS coupling / ...

  • Detalles del producto

Industrial coupling relay of Siemens SIRIUS series, equipado con 2 contactos de cambio, wide voltage range 24-240V AC/DC and screw terminals. It serves as a replacement for 3TX7002-1CB00 and 3RS1800-1BW00, and is designed for SOCIEDAD ANÓNIMA signal isolation and control circuit coupling.

  1. Interpretación del código modelo
Segmento de modeloSignificado
3RQProduct family code for Siemens SIRIUS coupling / interface relays
2Generation code, distinguishing from 3RQ0, 3RQ3 and other series
0Basic model with wide voltage range of 24-240V AC/DC
-1Terminal type code: 1 = Screw terminal, 2 = Spring terminal
BContact configuration code: B = 2 contactos de cambio (2CO); Una = 1 contacto de cambio (1CO); C = 3 contactos de cambio (3CO)
W.Material de contacto & characteristic code: W = Standard silver tin oxide (AgSnO) contacto; CW01 = Hard gold plated contact
0Supplementary code for version & specification, no special definition

Full Name: Enclosed industrial coupling relay, 2 contactos de cambio, 24-240V AC/DC wide voltage, screw terminal connection.

  1. Parámetros técnicos básicos
Categoría de parámetroEspecificaciónObservaciones
Información básica
Marca / SerieSiemens SIRIUS 3RQ2Industrial-grade signal coupling solution
Número de pedido.3RQ2000-1BW00Standard part number
Tipo de montajeDIN rail mount, ancho: 22.5milímetrosCumple con EN 60715
Protección de ingresoIP20Finger-proof and dust-proof
Parámetros eléctricos
Rango de voltaje de control24-240VCA/CCWide voltage design for high versatility
Rated Control Power4.5W.Bajo consumo de energía
Configuración de contacto2 contactos de cambio (2CO)Each contact consists of 1 NO + 1 CAROLINA DEL NORTE
Rated Contact Current5A @ 250V ACFor resistive load
máx.. Switching Voltage300VCA/CCCumple con IEC 60947-1
Voltaje de aislamiento300V (Overvoltage Category III, Grado de contaminación 3)Excellent insulation performance
Impulse Withstand Voltage4kVFuerte resistencia a sobretensiones
Parámetros mecánicos
Dimensiones (Ancho × Alto × Fondo)22.5×90×65mmEstructura compacta
PesoAprox.. 100gramoFácil instalación
Vida mecánica1,000,000 operacionesHigh durability
Vida eléctrica100,000 operaciones (at rated load)Stable and reliable performance
Parámetros ambientales
Temperatura de funcionamiento-40°C ~ +60°CAdaptable to harsh industrial environments
Temperatura de almacenamiento-40°C ~ +85°CWide temperature range for storage
Rango de humedad5%~95% (sin condensación)Suitable for humid conditions
Grado de contaminación3Applicable to dusty industrial sites
  1. Marca cruzada & Obsolete Model Replacement List
Modelo OriginalModelo de reemplazoDescripción de reemplazo
Siemens 3TX7002-1CB003RQ2000-1BW00Reemplazo oficial recomendado; 22.5mm width unchanged, fully function compatible
Siemens 3RS1800-1BW003RQ2000-1BW00Official replacement; discontinued since Oct 1, 2022
Siemens 3RQ2000-1AW003RQ2000-1BW00In-series upgrade from 1CO to 2 contactos de cambio
Schneider RXM4AB2BD3RQ2000-1BW00Funcionalmente equivalente; 2CO, 24-240VCA/CC, DIN rail mount
ABB CR-M230AC23RQ2000-1BW00Funcionalmente equivalente; 2CO, amplio voltaje, industrial application

Consejos de selección: Verify full consistency of contact quantity, tipo de terminal, mounting dimensions and electrical parameters before replacement.

  1. Full Model List of 3RQ2000 Series
ModeloConfiguración de contactoTipo de terminalMaterial de contactoRango de voltajeObservaciones
3RQ2000-1AW001COTornilloEstándar24-240VCA/CCModelo básico
3RQ2000-1BW002COTornilloEstándar24-240VCA/CCSubject model
3RQ2000-1CW003COTornilloEstándar24-240VCA/CCMulti-contact model
3RQ2000-1CW013COTornilloHard gold plated24-240VCA/CCAlta confiabilidad, for light load
3RQ2000-2AW001COPrimaveraEstándar24-240VCA/CCFast wiring model
3RQ2000-2BW002COPrimaveraEstándar24-240VCA/CCSpring terminal, 2 contactos de cambio
3RQ2000-2CW003COPrimaveraEstándar24-240VCA/CCSpring terminal, 3 contactos de cambio
3RQ2000-2CW013COPrimaveraHard gold plated24-240VCA/CCSpring terminal, alta confiabilidad
  1. Fallos comunes & Solución de problemas
Fenómeno de fallaPosibles causasSoluciones
Relay fails to operate1. Control voltage out of range1. Measure voltage and ensure it is within 24-240V
2. Terminales sueltos2. Check and tighten screw terminals
3. bobina quemada3. Reemplazar el relé
Mal contacto de contactos.1. Oxidation / contamination of contacts1. Clean contacts or replace the relay
2. Contact welding caused by overload2. Reduce load or select higher-capacity model
3. Excessive vibration during operation3. Fasten installation and add vibration dampers
Indicator light off while relay operates normally1. Damaged LED indicator1. Replace LED module
2. Fault of indicator circuit2. Inspect wiring of indicator circuit
Random operation of relay1. Interference on control circuit1. Use shielded cables and keep away from interference sources such as inverters
2. Severe voltage fluctuation2. Install voltage stabilizer
3. Ambient temperature out of limit3. Improve heat dissipation or select high-temperature resistant model
Overheated terminals1. Cableado suelto1. Reapretar terminales
2. Undersized wire cross-section2. Replace with wires of proper cross-section
3. Excessive load current3. Reduce load or replace the relay
  1. Ámbito de aplicación & Casos de la industria

6.1 Escenarios aplicables

PLC Signal Isolation: Couple signals between PLC outputs and field actuators to protect PLC modules.

Expansión del circuito de control: Increase available control signals to drive multiple loads via one signal.

Conversión de voltaje: Connect control circuits with different voltage levels, p.ej. 24V DC PLC output for 220V AC contactors.

Interference Suppression: Isolate signals in high-interference environments such as inverters and welding equipment to avoid false triggering.

Sistemas de automatización industrial: control de línea de producción, maquinaria de embalaje, maquinas herramientas, conveyor systems, etc..

6.2 Non-recommended Scenarios

High-frequency switching: Not suitable for frequent switching over 10 cycles per second.

Inductive load without protection: Surge suppressors are mandatory when driving inductive loads such as motors and solenoid valves.

Corrosive environments: No special anti-corrosion treatment; not for strong acid, alkali or high salt mist conditions.

Áreas peligrosas explosivas: Diseño no a prueba de explosiones; prohibited for flammable and explosive locations.

6.3 Casos de aplicación típicos

Caso 1: Automotive Component Production Line

Solicitud: PLC controls clamps and welding torches of robotic welding stations.

Configuración: 3RQ2000-1BW00 isolates PLC output signals from 220V AC solenoid coils.

Resultado: Resists welding current interference; failure rate reduced by 90%, costos de mantenimiento reducidos 50%.

Caso 2: Alimento & Beverage Filling Line

Solicitud: Connect HMI touch panel and filling valve control circuits.

Configuración: Two units of 3RQ2000-1BW00 control 4 filling valves (2 NO + 2 CAROLINA DEL NORTE) via one HMI signal.

Resultado: Simplified wiring, improved system reliability and fewer spare part types.

Caso 3: Intelligent Warehousing System

Solicitud: Isolate position sensor signals of stacker cranes and PLC inputs.

Configuración: 3RQ2000-1BW00 converts 24V DC sensor signals to PLC-compatible signals.

Resultado: Eliminates interference from long-distance signal transmission; positioning accuracy improved to ±1mm.

  1. Directrices de selección & Reglas de referencia rápida
  2. Contact quantity by letter: A = 1CO, B = 2CO, C = 3CO
  3. Terminal type by digit: 1 = Screw terminal, 2 = Spring terminal
  4. Contact material by suffix: W = Standard contact, CW01 = Gold-plated contact
  5. Universal voltage: Full series supports 24-240V AC/DC
  6. Priority for replacement: Directly replace 3TX7 / 3RS18 series with corresponding 3RQ2000 models

Ordering Notice: Paquete estándar: 1 unidad por caja; Minimum order quantity: 1 unidad. It is recommended to prepare 2~3 units as spare parts for general industrial automation control.

Common Faults and Troubleshooting of Siemens 3RQ2000-1BW00 Coupling Relay

  1. Relay Fails to Operate Completely
  2. No power supply to coil

Measure input voltage to confirm it is within 24~240V AC/DC. Check circuit breakers, fuses and continuity of upstream control circuits, and tighten loose terminals.

  1. Perder / poor terminal connection

Retighten screw terminals. Check wire crimping, broken wires and wires trapped under terminal screws.

  1. bobina quemada

Long-term overvoltage or frequent voltage surges will burn the coil. Replace the relay if burnt marks or abnormal odour are observed.

  1. Atasco mecánico

Accumulated dust and continuous vibration cause internal armature sticking. Tap the housing gently for test; replace the relay if the issue persists.

  1. Coil Pulls In but Contacts Open / Mal contacto
  2. Oxidation and dust accumulation on contacts

Commonly seen in humid and dusty environments, especially for low-power signal circuits. Clean contacts after power cut and test with repeated switching operations.

  1. Contact welding

Excessive load current or frequent inrush load leads to stuck contacts. Disconnect the load for verification. Replace the relay as welded contacts cannot be repaired.

  1. Fault on load side circuit

Troubleshoot downstream contactors, solenoid valves and broken wires. Confirm relay fault only after excluding external failures.

  1. Random Operation / Unexpected On & Apagado
  2. Interferencia electromagnética

Easily affected when installed close to inverters, motores, high-power contactors or long control cables. Route control cables away from power cables and apply shielded wires and surge absorbers.

  1. Fluctuación de voltaje & electrical noise

Sudden voltage drop and voltage spikes cause false operation. Install voltage stabilizers and filters on the upstream side.

  1. Abnormal ambient temperature

Operation above +60°C or condensation under low temperature leads to internal circuit malfunction. Mejorar la ventilación, dehumidification and heat dissipation.

  1. Abnormal Indicator Light
  2. Light off, relay works normally

Only the LED bulb is damaged. The relay can remain in service or be replaced.

  1. Light always on / flickering, relay does not operate

Malfunction of internal voltage divider and indicator circuit, usually accompanied by coil failure. Replace the relay directly.

  1. Overheated Wiring Terminals
  2. Cableado suelto: Retighten terminals to specified torque.
  3. Undersized wire gauge: Replace with cables with cross-section matching the load current.
  4. Continuous overload: Actual load exceeds rated 5A contact current. Apply load sharing or use higher-capacity relay.
  5. Frequent Failures under Inductive Load (Solenoid / contactor)

Symptoms: Shortened contact service life, frequent contact welding and unexpected tripping

Solución de problemas: The absence of surge suppressors causes reverse high voltage from inductive loads to damage contacts during power-off. Connect freewheeling diodes (for DC) or RC snubbers (for AC) in parallel across inductive loads.

  1. On-site Quick Troubleshooting Procedure
  2. Cut off power → Inspect appearance, wiring and terminal tightness
  3. Switch on power → Measure input control voltage
  4. Observe indicator light and listen to pull-in sound to judge coil status
  5. Cut off power → Test NO/NC contacts with multimeter continuity mode
  6. Distinguish faults among upstream control circuit, relay itself and downstream load circuit

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje