FFB1424VHG Delta Industrial Axial Fan

Delta FFB series high airflow axial fan, dimensions 140×140×50.8mm, 24En DC, equipped with double ball bearings. It is widely used for heavy-duty heat dissipation of inverters, UPS systems and industrial power supplies. Airflow: 252.11 CFM, Presión de aire: 16.36 mmH₂O, Rotation Speed: 3200 RPM, Corriente nominal: 1.37 A, Nivel de ruido: 58.5 dB. Model Code Explanation Code ...

  • Detalles del producto

Delta FFB series high airflow axial fan, dimensions 140×140×50.8mm, 24En DC, equipped with double ball bearings. It is widely used for heavy-duty heat dissipation of inverters, UPS systems and industrial power supplies.

Airflow: 252.11 CFM, Presión de aire: 16.36 mmH₂O, Rotation Speed: 3200 RPM, Corriente nominal: 1.37 A, Nivel de ruido: 58.5 dB.

  1. Explicación del código del modelo
Segmento de códigoSignificadoDescripción
FFBSerie de productosDelta FFB series industrial axial fan, high-performance cooling type, size 140×140×50.8mm
14DimensiónTamaño del marco: 140mm×140mm
24Tensión nominal24En DC (Operating range: 14.0~26.4VDC)
VGrado de desempeñoMid-to-high performance. Airflow, air pressure and current are between S (Estándar) and H (Rendimiento alto) versiones
hFunctional FeatureBuilt-in Hall sensor for speed feedback and speed monitoring
GRAMOWiring TypeGeneral wire output, optional 3-wire or 4-wire (with PWM speed control) versión
-R00/-F00/-EPSuffix Code-R00: Versión estándar; -F00: Long-life version; -EP: Eco-friendly certified version
  1. Main Specifications
ArtículoValorObservaciones
MarcaDeltaRenowned manufacturer of industrial fans based in Taiwan, Porcelana
TipoBrushless DC Axial FanLarga vida útil, low power consumption and high reliability
Dimensiones140×140×50.8mm (14050 format)Standard industrial mounting size
Tensión nominalCC 24 VOperating range: 14.0~26.4VDC
Corriente nominal1.37 Amáx.. fuerza: aprox. 32.88 W.
Rotation Speed3200 RPMTypical value, measured in free air
Airflow252.11 CFM (7.139 m³/min)Maximum airflow in free air
Presión de aire16.36 mmH₂O (0.644 IN H₂O)Maximum static pressure at zero airflow
Ruido58.5 dB-AMeasured at 1m on the air intake side in an anechoic chamber
Tipo de rodamientoDouble Ball BearingLonger lifespan than sleeve bearings, suitable for continuous heavy-load operation
Vida útilAprox.. 50,000 hours @ 25℃Typical lifespan for double ball bearings; encima 70,000 hours for long-life version
Protección de ingresoIP20Basic dustproof, for indoor dry environments
MaterialImpeller & Marco: UL94V-0 Flame Retardant PlasticHigh safety rating for industrial use
Lead WireUL 1430 AWG #22Standard industrial wire, rojo (+) / negro (-) color coding
Peso670 gramo (23.63 oz)Robust structural design
CertificacionesUL, CSA, VDE, RoHS, ALCANZARCompliant with international safety and environmental standards
  1. Compatibilidad entre marcas & Replacement List
MarcaModelo equivalentePresupuestoRecomendación de reemplazo
DeltaFFB1424SHG24V, 0.91A, 2800RPM, 219.73CFMSlightly lower airflow & actual, lower noise (54.5dB). Ideal for noise-sensitive applications
DeltaFFB1424HHG24V, 1.53A, 3600RPM, 273.09CFMHigher airflow & actual, higher noise (61.7dB). Suitable for extreme heat dissipation scenarios
NidecD08A-24TS324V, 1.2A, 3000RPM, 240CFMRendimiento similar, identical dimensions, reemplazo directo
Sanyo9GV1424P1G00124V, 1.4A, 3200RPM, 250CFMNearly identical parameters, compatible mounting holes
EBM-papst4414F/2HH24V, 1.3A, 3100RPM, 245CFMEuropean brand with higher price, for high-end equipment
SunonKDE1205PFV324V, 1.35A, 3200RPM, 250CFMReliable quality with moderate price
  1. Full FFB14xx Series Model List
ModeloVoltajeActualVelocidadAirflowPresión de aireRuidoCaracterísticas
FFB1424SHG24V0.91A2800RPM219.73CFM12.84mmH₂O54.5dBStandard performance, bajo ruido
FFB1424VHG24V1.37A3200RPM252.11CFM16.36mmH₂O58.5dBMid-to-high performance, balanced type
FFB1424HHG24V1.53A3600RPM273.09CFM19.84mmH₂O61.7dBRendimiento alto, large airflow
FFB1448SHG48V0.50A2800RPM219.73CFM12.84mmH₂O54.5dBStandard performance, 48V fuente de alimentación
FFB1448VHG48V0.77A3200RPM252.11CFM16.36mmH₂O58.5dBMid-to-high performance, 48V fuente de alimentación
FFB1448HHG48V0.77A3600RPM273.09CFM19.84mmH₂O61.7dBRendimiento alto, 48V fuente de alimentación
FFB1424VHG-EP24V1.37A3200RPM252.11CFM16.36mmH₂O58.5dBEco-friendly version, RoHS & REACH compliant
FFB1424VHG-R0024V1.37A3200RPM252.11CFM16.36mmH₂O58.5dBStandard mass production version
  1. Entorno de aplicación & Guía de selección

Aplicaciones recomendadas

Industrial Inverters: Heat dissipation for medium & high-power inverters of ABB, siemens, Schneider and other brands

UPS Systems: Cooling for core components of uninterruptible power supplies

Servo Drives: Cooling for servo systems of industrial robots and CNC machine tools

Suministros de energía industriales: Heat dissipation for high-power switching power supplies and rectifiers

Servers & Centros de datos: Cooling for high-density server enclosures, especially edge computing devices

Equipo médico: Heat dissipation for precision devices such as MRI and CT scanners

Rail Transit: Cooling for train control systems and traction converters

Not Recommended Applications

Unprotected Outdoor Areas: Low IP20 rating, vulnerable to dust and moisture

Inflamable & Explosive Zones: No explosion-proof certification, not for chemical, mining and other hazardous locations

Alimento & Pharmaceutical Clean Rooms: No sanitary certification

Extremely Low Temperature Environments: Operation below -10℃ may affect startup performance and service life

Consejos de selección

14050 fixed size, choose 24V or 48V power supply;

S/V/H stands for different performance, airflow and pressure increase in sequence;

Double ball bearings ensure long life, Hall sensor enables clear speed monitoring;

Ideal choice for inverters and UPS, stable under high temperature and heavy load.

  1. Fallos comunes & Solución de problemas
Fenómeno de fallaPosibles causasPasos para solucionar problemasSoluciones
Fan not running1. Power disconnected1. Check input voltage1. Reconnect power supply
2. Motor burnout2. Verify wiring connection2. Replace with identical fan
3. Seized bearing3. Rotate fan manually to check flexibility3. Clean bearing or replace fan
4. Control circuit failure4. Inspect control signals4. Repair control circuit
Abnormal speed1. Fluctuación de voltaje1. Confirm voltage within 14~26.4V range1. Stabilize power voltage
2. Excessive load2. Check for blocked air duct2. Clear air duct or use higher airflow fan
3. Hall sensor failure3. Test Hall signal output3. Replace fan
4. Abnormal PWM signal4. Inspect PWM signal4. Repair PWM circuit
Ruido excesivo1. Worn bearing1. Identify noise source for bearing issues1. Replace fan
2. Instalación suelta2. Tighten mounting screws2. Fasten screws
3. Dust accumulated on blades3. Check blades for dust or foreign objects3. Clean fan blades
4. Resonance4. Inspect mounting bracket4. Add shock-absorbing pads or adjust installation position
Reduced airflow1. Dirty blades1. Check blade cleanliness1. Clean blades
2. Blocked air duct2. Inspect air inlet & outlet2. Clear air duct
3. Speed drop3. Measure fan speed3. Troubleshoot speed issues
4. Rotación inversa4. Check positive/negative wiring4. Correct wiring polarity
Shortened service life1. Temperatura ambiente excesivamente alta1. Measure ambient temperature1. Add auxiliary cooling or use high-temperature resistant fan
2. Heavy dust2. Check dust prevention measures2. Install dust filter
3. Unstable voltage3. Test voltage fluctuation3. Stabilize power supply
4. Arranques y paradas frecuentes4. Review control logic4. Optimize control logic to reduce start-stop cycles
  1. Industrial Application Cases

Caso 1: Heat Dissipation Upgrade for Schneider Inverters

A factory frequently encountered overheating alarms on Schneider ATV61 series inverters. The original sleeve-bearing fans had short lifespan and insufficient airflow.

Solución: Replaced with Delta FFB1424VHG double ball bearing fans. Airflow increased by 30% and service life extended to 50,000 horas.

Resultado: Inverter failure rate reduced by 80%; maintenance interval extended from 3 meses para 2 años, saving approximately RMB 12,000 in annual maintenance costs.

Caso 2: Server Cooling Optimization for Data Center

High-density servers in an edge computing data center suffered from overheated CPU and performance degradation due to inadequate original cooling fans.

Solución: Installed 2 sets of 4-wire PWM controlled FFB1424VHG fans at the rear of server enclosures, linked with the server temperature control system.

Resultado: CPU temperature dropped by 12℃, system performance improved steadily by 15%. Energy consumption and noise were also reduced via PWM speed regulation.

Caso 3: Cooling for Medical MRI Scanner

Poor heat dissipation on the power modules of an in-hospital MRI scanner caused frequent downtime and disrupted medical services.

Solución: Adopted customized long-life version (-F00) FFB1424VHG fans and optimized air duct layout for uniform heat dissipation.

Resultado: Equipment operational stability improved by 95%, downtime reduced by 90%. The service life of power modules was prolonged and maintenance costs decreased.

FFB1424VHG is a balanced high-performance industrial fan from Delta FFB series. Featuring large airflow, high air pressure and long service life, Se aplica ampliamente en la automatización industrial., power electronics, data centers and other fields.

Select the proper model according to actual requirements on voltage, airflow, noise and service life, together with corresponding suffix versions (-R00/-F00/-EP). Follow installation specifications and perform regular maintenance to achieve optimal cooling performance and maximum service life.