Siemens 6ED1052-1FB08-0BA2 Controller Base Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Siemens 6ED1052-1FB08-0BA2 Controller Base Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Siemens 6ED1052-1FB08-0BA2 Controller Base Module

Siemens 6ED1052-1FB08-0BA2 (LOGO!230RCE V8.4) Application Scenarios Key characteristics: Direct 230 V AC supply, salidas de relé, on-board display, Ethernet (MQTT / Modbus-TCP / embedded web pages), multiplexable 0-10 V analog inputs. Suitable for small-I/O-count logic control with 220 V supply and remote monitoring requirements. Programmed via graphical function-block editor without complex PLC programming. Native I/O: 8 DE / 4 ...

  • Detalles del producto

siemens 6ED1052-1FB08-0BA2 (LOGO!230RCE V8.4) Escenarios de aplicación

Key characteristics: Direct 230 V AC supply, salidas de relé, on-board display, Ethernet (MQTT / Modbus-TCP / embedded web pages), multiplexable 0-10 V analog inputs. Suitable for small-I/O-count logic control with 220 V supply and remote monitoring requirements. Programmed via graphical function-block editor without complex PLC programming. Native I/O: 8 DE / 4 HACER; expandable with LOGO!8-series expansion modules.

Full Designation: LOGO! 230RCE Logic Controller Base Module, with Display, Ethernet, Salida de relé, 115-230 V AC/DC Supply

  1. Decodificación de código modelo
Segmento de códigoDescripción
6ED1052LOGO! base main unit series
1With display; 0 = without display
FBTipo de fuente de alimentación: FB = 115‑230 V AC/DC, Salida de relé(R)
8Versión de hardware 08 (LOGO! 8 hardware platform)
0BA2Firmware version: V8.4 (supports MQTT, Web‑Server, Micro‑SD Card)
  1. Especificaciones eléctricas básicas
ArtículoParámetro
Voltaje de suministro100‑253 V AC/DC (nominal 115/230 V), 47‑63 Hz
Digital Inputs DI8‑channel (I1‑I8); I1/I2/I7/I8 are multiplexable for 0‑10 V analog inputs
Digital Outputs DO4‑channel relay outputs Q1‑Q4
Carga resistiva: 10 A per channel; Inductive load: 3 A per channel
⚠️ Outputs have no built‑in short‑circuit protection; external fuses are mandatory
Capacidad del programamáx.. 400 function blocks; Real‑time clock backup 480 h for retaining timer parameters upon power loss
Interfaz de comunicación1×RJ45 Ethernet; Soportes: LOGO! internal protocol, Modbus‑TCP, MQTT, built‑in Web‑Server, registro de datos, custom web pages
AlmacenamientoMicro‑SD card slot (copia de seguridad del programa, actualización de firmware)
Software de programaciónLOGO! Soft Comfort V8.4 or higher
Montaje35 mm DIN‑rail mounting
Dimensiones generalesW71.5 × H90 × D60 mm, IP20
Temperatura ambiente de funcionamiento‑20 ℃ ~ +55 ℃; Almacenamiento: ‑40 ℃ ~ +70 ℃
CertificacionesCE, UL, FM, RoHS
  1. Hardware & Notas de cableado
  2. Input terminals I1-I8 are universal AC/DC inputs matched to the 115-230 V supply rating. When I1/I2/I7/I8 are software-enabled as 0-10 V AI, these terminals shall receive voltage signals and must NOT be connected to high-voltage mains.
  3. Relay outputs are potential-free contacts; common terminals can be wired to circuits of different voltage levels. Para cargas inductivas (contactores, válvulas solenoides), RC snubber circuits must be connected in parallel.
  4. LAN port: For programming, remote web-based monitoring, MQTT cloud uplink; built-in web pages are accessible directly via web browser.
  5. SD-Card: Importar / export programs & logs, perform firmware upgrade.

⚠️ Critical Prohibitions

Do not exceed ratings: 10 A resistive / 3 A inductive for relay outputs. Do not drive high-power motors directly. External fuses are required.

When channels are multiplexed for analog input (0-10 V), applying AC230 V will destroy input circuitry.

Clasificación IP20: For cabinet-mount use only. Not for outdoor installation, condensing or corrosive environments.

  1. Compatible Replacement Options

Direct drop-in replacement: `6ED1052-1FB08-0BA2` (LOGO! V8.4, current order reference)

Legacy compatible variant: `6ED1052-1FB08-0BA1` (V8.3, identical pin-out, backward-compatible program; older firmware lacks MQTT features)

Nota: LOGO!8.incógnita (0BA8) base units are NOT compatible with legacy 0BA7 / 0BA6 expansion modules. Use LOGO!8-series expansions only (p.ej. 6ED1055-1FB00-0BA2).

  1. Escenarios de aplicación típicos

Building automation: control de iluminación, admirador & pump management, climatización, auxiliary access-control logic; stand-alone simple machine control; agricultural irrigation; interlock logic for packaging machinery; IoT edge data acquisition, MQTT uplink to SCADA / cloud platforms.

  1. Package Contents

Main unit ×1

Printed quick-start manual ×1

❗ Excluded: Ethernet cable, SD-card, external fuses, módulos de expansión (order separately).

5.1 Building HVAC (Primary Use-Case)

  1. control del ventilador: Extractores de aire, fresh-air supply-fan interlocks; scheduled start-stop, differential-pressure trigger, alarma de falla; web-based remote status visualization.
  2. Control de bomba: Domestic-water / circulation pumps with duty-standby automatic change-over, overload alarm, water-level interlocking.
  3. Lighting-control system

Scheduled lighting for workshops, underground car-parks and public corridors; PIR trigger, holiday calendar scheduling.

Fire-alarm interlock for lighting cut-off; upload lighting status via Ethernet to central control room.

  1. Air-handling unit & damper control: Damper actuators, heater simple logic; 0-10 V channels acquire temperature / humidity transmitters for basic closed-loop regulation.
  2. Cooling-tower & roof ventilation: Local logic plus remote web monitoring; MQTT data upload to building BA-system.

Ventajas: No separate 24 V power supply required for 230 V operation; built-in web-server removes need for dedicated SCADA for browser-based supervision.

5.2 Stand-alone Simple Machine Control

For low-I/O machinery where full-scale PLC is not justified

  1. Packaging auxiliary equipment: Conveyor start-stop interlocks, silo level detection, alarm indicators, timed discharging cycles.
  2. Injection-molding auxiliary & cooling units: Cooling-fan / circulation-pump logic; 0-10 V temperature acquisition, fault-alarm output.
  3. Air-compressor auxiliary control: Exhaust-fan, timed solenoid drain valve, aggregated fault-signal output.
  4. Puerta / roller-shutter / lifting-door logic: Limit-switch monitoring, interlocks, time-delay, manual-auto mode switching.

⚠️ Limitation: máx.. 3 A inductive rating for relay contacts; use intermediate relays for large contactor coils. Not applicable for high-speed pulse-based motion control.

5.3 Agricultura & Tratamiento de agua

  1. Greenhouse simplified automation: Admirador & shade-blind actuation; 0-10 V temperature-humidity acquisition; timed irrigation solenoids; MQTT upload to IoT platform.
  2. Small-scale wastewater / reclaimed-water equipment: Pump rotation scheduling, high-low level interlocks, timed chemical-dosing, alarm outputs.
  3. Fountains & water-feature installations: Cyclic multi-pump sequencing, fault-alarm logic.

5.4 Electrical Cabinet & LV Panel Auxiliary Logic

  1. Low-voltage switchgear auxiliary logic: Bus-coupler interlocking, cabinet cooling-fan control, cabinet-door status acquisition, collective fault-alarm output.
  2. fotovoltaica / energy-storage auxiliary cabinets: Cabinet-heater / dehumidifier & cooling-fan temperature-driven / timed control; alarm telemetry over Ethernet.
  3. UPS emergency-power auxiliary logic: Mains-failure detection, switching logic, audible-visual alarm outputs.

5.5 IoT Edge Acquisition (V8.4-Exclusive MQTT Feature)

Core enhancement versus older V8.3 (-0BA1 firmware):

  1. Acquire digital status and 0-10 V analog measurements; transmit via MQTT to private / public cloud servers (p.ej. Alibaba Cloud).
  2. Operate as Modbus-TCP slave for connection to HMI / host supervisory systems. Built-in web-server for PC / mobile-browser status access without dedicated software.
  3. Micro-SD-card data logging: record temperature, runtime timestamps; export CSV files for maintenance review.

❌ Non-Applicable Scenarios (Selection Pitfalls)

  1. High-speed counting, pulse-output, servo motion control: Not supported by LOGO!.
  2. Large I/O quantity: Native 8DI /4DO; maximum expandable to 24DI /16DO. For larger systems select S7-1200 PLC.
  3. Frequent switching of heavy inductive loads: Limited mechanical relay contact life; use transistor-output variants for high-cycle applications.
  4. Hazardous / explosive-risk zones: IP20 unit must be installed inside certified explosion-proof enclosures; cannot be mounted directly in Zone1/Zone2.
  5. High-precision PID closed-loop control: Only basic PID function-block available; use standard PLC for demanding closed-loop performance.

Typical System Configuration Examples

Temperature acquisition: Multiplex I1 as 0-10 V AI for connection to temperature transmitter.

Contactor driving: LOGO! relay output → intermediate relay → contactor coil.

Monitoreo remoto: RJ45 LAN to local network; access embedded web-server via browser.

expansión de E/S: 6ED1055-1FB00-0BA2 (230 V relay expansion module).

Siemens 6ED1052-1FB08-0BA2 (LOGO!230RCE V8.4) Full Technical Datasheet

Full Designation: LOGO! 230RCE Logic Controller Base Module, with Display, Ethernet, Salida de relé, 115-230 V AC/DC, Firmware V8.4 with MQTT support

Power Supply Ratings

ArtículoEspecificación
Voltaje de suministro100‑253 V AC / corriente continua (nominal 115‑230 V AC/DC)
AC Frequency Range47‑63 Hz
Consumo de energíaAprox.. 3.5 W.
RTC Backup Duration480 h (20 days); retains real‑time clock and timer parameters after power loss

I/O Terminal Specifications

ArtículoEspecificación
Digital Inputs DI8‑channel (I1‑I8); rated for 115‑230 V AC/DC signals.
I1, I2, I7, I8 software‑configurable as 0‑10 V analog inputs (AI), 10‑bit resolution
Digital Outputs DO4‑channel potential‑free relay outputs Q1‑Q4
Carga resistiva: 10 A per channel; Inductive load: 3 A per channel
⚠️ No built‑in short‑circuit protection; external fuses are mandatory
Tipo de salidaMechanical relay contacts; common terminals can be assigned to different voltage domains
máx.. Expanded I/OBase unit + LOGO!8 módulos de expansión: máx.. 24DI /16DO

Program & Memoria

ArtículoEspecificación
máx.. Function Blocks400 blocks (depends on block type)
Software de programaciónLOGO! Soft Comfort V8.4 or higher
Storage MediaMicro‑SD card slot: copia de seguridad del programa, actualización de firmware, CSV‑format data log export
Mostrar6‑line backlit LCD; local push‑buttons for parameter modification & status review

Interfaz de comunicación (RJ45 Ethernet 10/100 Mbit/s)

LOGO! native protocol (programación, multi-LOGO! LAN networking)

Modbus-TCP (Master / Slave)

MQTT Client (V8.4 new feature, for private / public cloud connection)

Embedded Web-Server: browser-based supervision, custom web pages, registro de datos, email alarm notification

❗ Does NOT support Profinet, CANabierto, KNX.

Mecánico & Montaje

ArtículoEspecificación
Montaje35 mm standard DIN‑rail (4‑module width)
Dimensiones generalesW71.5 mm × H90 mm × D60 mm
Protección de ingresoIP20 (cabinet‑installation only)
PesoAprox.. 200 g

Condiciones ambientales

ArtículoRango
Temperatura ambiente de funcionamiento‑20 ℃ ~ +55 ℃ (inside control cabinet)
Almacenamiento & Temperatura de transporte‑40 ℃ ~ +70 ℃
Humedad relativa5 %‑95 % RH, condensation not permitted
Vibración & ChoqueCompliant with IEC60068‑2‑6 / IEC60068‑2‑27 industrial standards

Aprobaciones & CEM

Certificaciones: CE, UL, FM, RoHS

CEM: EN55011 Class B (residential environment), EN61000-6-2 industrial immunity

Critical Limitations (Selection Constraints)

  1. Relay outputs are not suitable for high-cycle switching; intermediate relays must be used for heavy loads.
  2. When channels are configured for 0-10 V analog input, AC230 V mains must never be connected, as input hardware will be destroyed.
  3. No native high-speed counter, pulse-output or motion-control functions.
  4. Only LOGO!8-series expansion modules (order suffix-0BA2) are compatible; legacy 0BA7 / 0BA6 expansions will not work.
  5. No internal short-circuit protection; external fuses are required for all relay-output circuits.

Firmware Variant Comparison

6ED1052-1FB08-0BA1: V8.3, identical hardware pin-out; no MQTT, limited web-server capability.

6ED1052-1FB08-0BA2: V8.4, adds MQTT, enhanced web-server and improved email-alarm functions; current active ordering reference.