PLC SIEMENS 6ES7414-5HM06-0AB0

Marca: SIEMENS Series: SIMATIC S7-400H Redundant PLC Full Model Number: 6ES7414-5HM06-0AB0 Product Name: CPU 414-5H PN/DP High-Availability Redundant Central Processing Unit Production Status (June 2026): Marked as PLM PM300 Active (Mass Production & Available for Sale) on SIEMENS official industrial mall. No discontinuation notice issued. Brand-new original units can be ordered normally. Factory lead time ...

  • Detalles del producto

Marca: SIEMENS

Serie: SIMATIC S7-400H Redundant SOCIEDAD ANÓNIMA

Full Model Number: 6ES7414-5HM06-0AB0

Nombre del producto: CPU 414-5H PN/DP High-Availability Redundant Central Processing Unit

Production Status (June 2026): Marked as PLM PM300 Active (Mass Production & Available for Sale) on SIEMENS official industrial mall. No discontinuation notice issued. Brand-new original units can be ordered normally. Factory lead time ranges from 4 a 12 semanas, and domestic agents maintain spot inventory.

Firmware Baseline: V6.0 (online upgradable to minor versions V6.0.1 ~ V6.0.10; CPUs of the same model with different minor firmware revisions support redundant compatibility)

Origen: Alemania

  1. Breakdown of Order Number 6ES7414-5HM06-0AB0
Segmento de códigoExplicación
6ES7Standard prefix for SIMATIC S7 PLC modules
414CPU model: High-performance redundant CPU within the 414 serie
55th-generation H redundant CPU (supports PN + dual DP + synchronous fiber interfaces)
hHigh Availability redundant CPU, designed for S7-400H/F/FH fault-tolerant systems
METROVersion with integrated PROFINET interface (PN/DP model)
6V6 hardware base unit version
0AB0Standard delivery packaging with no special customization

 

  1. Core Hardware Memory & Computing Specifications
  2. Work Memory (Program + Data)

Memoria de programa: 2 MEGABYTE

Memoria de datos: 2 MEGABYTE

Total Work Memory: 4 MEGABYTE

  1. Load Memory: Incorporado 512 KB Flash; program and data storage requires expansion via S7 memory card
  2. Instruction Execution Speed

Boolean instructions: 18.75 ns per instruction

Integer operation: 0.1 μs; Floating-point operation: 1 μs

  1. Communication Resources

Maximum S7 communication connections: 64

Process image area: 2048 bytes for inputs, 2048 bytes for outputs

Local data stack: 16 KB

  1. Redundancy Switchover Performance: Standard switchover time <100 ms; supports CiR online hardware modification and capacity expansion without shutdown
  2. 5 Integrated Interfaces (Core Distinguishing Features)
  3. Interfaz 1: Combined MPI/PROFIBUS-DP Port

Supports MPI networking, DP master/slave mode

  1. Interfaz 2: Independent Dedicated PROFIBUS-DP Port

Separate DP bus for independent drive of field devices and isolation of bus load

  1. Interfaz 3: PROFINET IO Industrial Ethernet Port

PN controller supporting IRT real-time communication, PN IO, S7 communication, OPC UA, TCP/IP

  1. 2 Synchronization Interfaces (Fiber Slots)

Matched with synchronization fiber modules (6ES7960-1AA06-0XA0) for redundant data synchronization between dual CPUs; two synchronization media options: short-distance copper cable and long-distance fiber optic cable

  1. Fuente de alimentación & Especificaciones eléctricas

Backplane power supply: 5 En DC, típico 1.6 A, máximo 1.9 A

External 5 V for DP interfaces: máx.. 90 mA per channel

Power consumption of 24 V auxiliary circuit: ≤150 mA

Overall power consumption: Aprox.. 4 W.

Tensión soportada dieléctrica: 2 kV AC isolation between backplane and external interfaces

Peso: Aprox.. 995 gramo; Dimensiones: Standard S7-400 4U module (130 × 25 × 230 milímetros)

  1. Supported System Types
  2. S7-400H Standard Redundant System (Dual CPU hot standby without safety functions)
  3. S7-400F/FH Fail-Safe Redundant System (Paired with F safety packages to realize SIL2/SIL3 safety loops, compliant with chemical and power plant industry standards)
  4. Compatible with PCS7 V9.x, STEP7 V5.5 SP2 and above; supports full programming languages including CFC, GRAPH, SCL, STL, LAD/FBD
  5. Front Panel LEDs (Rapid Fault Diagnosis)

PWR: Green light – Backplane power supply normal

CORRER: Green light – Operating mode

DETENER: Yellow light – Stop mode

SF: Red light – System fault (program/hardware/communication error)

IF1/IF2: DP bus fault indicators

PN: PROFINET link status indicator

SYNC1/SYNC2: Redundancy synchronization link status indicators

  1. List of Typical Matching Accessories
  2. Synchronization fiber module: 6ES7960-1AA06-0XA0 (used in pairs)
  3. S7 Memory Card: Series 6ES7952 (2M/4M/8M)
  4. Synchronization fiber cables: 1 metro / 10 metro / 50 m fiber
  5. S7-400 UR2-H redundant rack, PS407/PS408 power supply modules
  6. DP bus connectors, PROFINET switches
  7. Escenarios de aplicación típicos

Redundant DCS PCS7 control systems for petrochemical and coal chemical industries

Redundant PLCs for auxiliary control, boilers and steam turbines in thermal/hydropower plants

Explosion-proof safety systems for large pharmaceutical and fine chemical plants (S7-400FH)

Tránsito ferroviario, large water plants, continuous metallurgical production lines (processes with zero downtime tolerance)

Large production lines and central air-conditioning integrated control systems

  1. Horizontal Comparison of Redundant CPUs in the Same Series
ModeloMemoriaInterfacesPosicionamiento
6ES7412-5HK06-0AB00.5M Program + 0.5M DataMPI/DP + PD, no PNSmall-scale low-cost redundancy
6ES7414-5HM06-0AB02METRO + 2M = 4MMPI/DP + Independent DP + PNMainstream medium-scale redundancy, most widely adopted in projects
6ES7416-5HM06-0AB06M Program + 10M DataTriple DP + PNLarge-scale multi-bus & big-data projects
6ES7410-5HJ08-0AB0mín.. 8M MemoryMultiple PN ports, new-generation V8 firmwareUpgrade replacement model, dedicated for TIA Portal
  1. Alternative Solution Description
  2. Direct Replacement with Same Specifications (Fully hardware-compatible, no rack/wiring modification)

Old and new firmware versions of the same order number 6ES7414-5HM06-0AB0 (V6.0.6 ↔ V6.0.10) support online hot replacement without redundancy synchronization conflicts.

  1. Generation Upgrade Solution (Recommended for New Projects)

6ES7410-5HJ08-0AB0 (CPU410-5H V8)

Ventajas: Larger memory, enhanced PROFINET real-time performance, native TIA Portal compatibility and longer supply cycle.

Desventajas: Existing STEP7 projects require migration; hardware cannot directly hot-swap to replace CPU414-5H.

  1. Distinction of Discontinued Old Models (Not Interchangeable)

Legacy 414H models (p.ej. 6ES7414-3HJ14-0AB0 V4.5) have been discontinued. Their synchronization modules, firmware and software are incompatible and cannot form redundant pairs with V06-version CPUs.

  1. Common Troubleshooting Matrix
Fenómeno de fallaCausa principalResolución
SYNC LED flashes, redundancy synchronization failsDamaged synchronization fiber / loose module, inconsistent firmware versions between two CPUsReplace fiber cable; unify firmware versions of both CPUs
SF LED stays on, DP bus error occursShort-circuited DP connector, missing bus terminating resistor, faulty slave stationTroubleshoot DP bus section by section; access DP diagnostics to check slave addresses
Disconnected PROFINET communicationDamaged network cable, faulty switch port, IP address conflictInspect link connection, verify CPU PN IP address, restart switch
CPU stays in STOP mode after power-on and cannot switch to RUNDamaged memory card, program error, failed F safety verificationRe-download program, replace memory card, inspect F safety program
Abnormal program operation after redundancy switchoverInconsistent programs on two CPUs, mismatched process image configurationSynchronize full program to both CPUs; compare hardware configuration online
  1. Suministrar & Procurement Key Points
  2. Factory Status: Active mass production, no discontinuation plan; spare parts support guaranteed for the next 5 años
  3. Ciclo de entrega: 4–12 weeks for brand-new original imported units; 3–7 days for spot goods from distributors
  4. Mandatory Redundancy Requirement: One H system must be equipped with two CPUs of identical order number and identical hardware version. Mixing CPU414-5H with CPU412/416H is prohibited.
  5. Software Requirements: STEP7 V5.5 with redundancy package / PCS7 V9.0 and above; TIA Portal requires supporting H-compatible libraries

 

Application Scenarios of SIEMENS 6ES7414-5HM06-0AB0 (CPU414-5H PN/DP)

This CPU is a medium-sized redundant PLC of the S7-400H series, equipped with MPI/DP, independent DP and PROFINET interfaces and a total work memory of 4 MEGABYTE. It supports millisecond-level bumpless redundancy switchover and targets medium-to-large industrial processes requiring zero downtime, alta confiabilidad, hybrid multi-bus communication and process safety. Classified scenarios by industry are listed below:

  1. Petroquímico & Coal Chemical Industry (Most Mainstream Application)
  2. Refining Units: Main process control for atmospheric-vacuum distillation, catalytic cracking, hydrogenation and reforming units; redundant interlock control of furnace temperature, pressure and flow to eliminate risks of oil leakage and explosion caused by system shutdown.
  3. Coal Chemical Industry: Gasification, synthesis, rectification and air separation units. Matched with S7-400FH to realize SIL2/SIL3 safety interlocks and meet explosion-proof safety regulations.
  4. Aceite & Gas Gathering & Transporte: Long-distance pipeline pump stations, crude oil storage depots and LNG receiving terminals. Remote PN+DP buses collect data from valves, compressors and liquid level transmitters; redundancy ensures continuous fluid transportation.
  5. Chemical Additive & Resin Production Lines: Continuous reactors and rectification towers. Process interruption will lead to scrapped materials and equipment caking, thus hot standby redundancy is mandatory.
  6. Industria energética (Thermal Power, Hydropower & New Energy Power Stations)

2.1 Thermal Power Plants

Boiler Auxiliary Control System: Induced draft fans, forced draft fans, coal mills and slag removal systems

Turbine Side: Circulating water, condensed water and lube oil station control

Water Treatment Workshop: Tratamiento de agua, demineralized water and chemical dosing systems

Flue Gas Desulfurization & Denitrification (SCR/SNCR): Continuous environmental emission monitoring; shutdown directly triggers environmental penalties.

2.2 Hydropower Plants

Water turbine speed regulation, gate opening/closing, plant seepage drainage and station power monitoring. System shutdown due to faults is forbidden during flood seasons.

2.3 New Energy Supporting Facilities

Auxiliary control of centralized booster stations for large-scale photovoltaic and wind power plants; temperature control and fire interlock of energy storage battery PACKs.

  1. Water Treatment Industry (Municipal & Industrial Wastewater)
  2. Large Municipal Water Plants: Water intake, sedimentation tanks, filtration, disinfection and water supply pump houses. Interruption of urban water supply is unacceptable.
  3. Large Sewage Treatment Plants: Aeration tanks, sludge dewatering, biochemical reactions and online water quality monitoring.
  4. Industrial Circulating Water Systems: Circulating cooling water and pure water preparation stations for steel mills and chemical parks.
  5. Continuous Metallurgical Production Lines (Acero & Non-Ferrous Metals)
  6. Hot & Cold Rolling Lines: Rolling mills, roller tables, heating furnaces and cooling sections. Full-line continuous rolling; shutdown causes steel billet scrapping and roller damage.
  7. Auxiliary Control for Smelting Blast Furnaces & Convertidores: Feeding, dust removal and gas recovery systems.
  8. Cluster control of aluminum/copper electrolytic cells; centralized monitoring via multiple DP slaves and PROFINET upper computers.
  9. Farmacéutico & Fine Chemical Industry (High Compliance Requirements)
  10. API and sterile preparation production lines: Fermentation tanks, purification and batching systems.
  11. Matched with S7-400FH fail-safe redundancy to comply with GMP production records and safety interlock regulations.
  12. Redundant control of air conditioning, temperature and constant pressure in clean workshops; shutdown will result in scrapping of entire batches of pharmaceuticals.
  13. Rail Transit & Large Tunnel Electromechanical Systems
  14. Integrated monitoring of urban metro/tunnels: Ventilation fans, suministro de agua & drenaje, fire protection, lighting and environmental control systems.
  15. Electromechanical equipment of large high-speed railway stations and tunnel drainage pump stations to guarantee traffic safety.
  16. Materiales de construcción & Paper Continuous Production Lines
  17. Paper machines and pulp production lines: Continuous paper conveying process; shutdown and paper breakage lead to massive economic losses.
  18. New dry-process cement production lines: Redundant control of kilns, coolers and raw material grinding equipment.
  19. Float glass production lines: Closed-loop control of tin bath and annealing furnace temperature & presión.
  20. Ports & Large Warehousing Logistics
  21. Bulk cargo handling systems at terminals: Cluster control of belt conveyors, stacker-reclaimers and tipplers.
  22. Centralized monitoring of large automated stereoscopic warehouses and cold storage facilities with 24/7 non-stop operation.
  23. General High-End Industrial Supporting Scenarios
  24. Central energy management of large air compressor stations and central air conditioning systems.
  25. Multi-equipment cluster automated production lines (automotive body welding and coating workshops).
  26. Pilot test devices in laboratories; redundant control systems integrated into complete export machinery equipment.

Selection Matching Logic (Why Choose CPU414-5H Over Other CPUs)

  1. Compared with CPU412-5H: Larger memory capacity, supports more DP/PN slaves and complex PID & interlock programs, suitable for medium and above complete process systems.
  2. Compared with CPU416-5H: Higher cost performance; fully meets the load requirements of most chemical, power auxiliary control and water plant projects at lower cost.
  3. Built-in PROFINET + dual DP buses: Simultaneously connects traditional DP instruments/drives and modern PROFINET inverters/switches, enabling compatibility between new and old equipment.
  4. Redundant hot standby switchover time less than 100 EM, satisfying mandatory requirements of bumpless continuous production in process industries.
  5. Supports PCS7 and F safety programs, applicable to projects requiring safety level certification such as chemical and power plants.