Manufactured by APtronic AG, modular embedded fuente de alimentación for Siemens SIMATIC IPC. A5E31006890-K9 denotes Revision:K9. It is a 150W AC-input industrial PC power supply, fin de vida. Available supplies on market include new old stock, used pull-out units and refurbished units.
- Definición del modelo
APtronic: German power supply manufacturer (OEM supplier for siemens IPC internal power modules)
cV5_AC: Power series model. AC = mains AC input; cV5_DC variant for DC input is also available.
A5E31006890: Siemens spare part order number; -K9 = Hardware Revision K9
Código HS: 85366990
- Especificaciones eléctricas
Aporte: CA 100–240 V, 50/60Hz, máximo. 2.3A, wide-range adaptive
Rated total output power: 150W.
Multiple DC outputs:
3V3: 8.5A
5V1: 16.5A
12V: 6.5A
N12 (-12V): 0.3A
Combined maximum 90W for 3.3V+5V
Montaje: Drawer-style embedded modular power supply with dedicated backplane connector. Not directly compatible with standard ATX power supplies
- Modelos compatibles (SIMATIC IPC / HMI IPC)
IPC627B, IPC627C
IPC827B, IPC827C
HMI IPC677B, HMI IPC677C
HMI IPC577C
Nota: cV5 series has multiple revisions (K6/K7/K9). Different revisions are hardware-compatible, though order numbers differ. Priority should be given to matching the spare part number during replacement.
- Especificaciones físicas
Dimensiones: aprox. 130 × 110 × 60 milímetros
Peso: aprox. 1kilos
Construcción: Metal shielded housing with integrated heat sink, sin ventilador incorporado. Cooling relies on the IPC chassis airflow.
- Fallos comunes & Solución de problemas
- IPC no power, no LED indicator
Check AC input socket and internal fuse first. Blown fuse usually accompanies damage to internal capacitors or switching transistors.
- Power cycles / instant power-off upon switch-on
Short circuit on output load (motherboard / hard disk short); or aged electrolytic capacitors inside the power unit (most frequent aging failure).
- Can boot, but random blue screens or unexpected power loss
Excessive ripple on 12V/5V outputs caused by capacitor degradation. Faults tend to occur more easily under low-temperature conditions.
Service reminder: All output channels must be tested under load. Voltage readings at no load cannot confirm the power supply is functional.
- Opciones de reemplazo
- Original identical replacement: A5E31006890-K9 (Optimal, enchufar y usar, no rewiring required). Interrumpido; only NOS / renovar / used stock available.
- Compatible within series: A5E02625806-K6 (cV5_AC Rev K6, compatible con hardware, different order number)
- Non-standard replacement (utilizar con precaución): Standard ATX cannot be fitted directly. Custom backplane adapter is required. Multi-channel output timing and PG signal must be matched. Not recommended for long-term use in industrial sites.
- Mantenimiento & Inspection Guidelines
Key inspection points during disassembly: Bulged electrolytic capacitors, PCB corrosion, burnt power components, oxidized connector pins.
Acceptance criteria for second-hand units: Load test of all output voltages, ripple measurement, power-up sequence check, minimum 2-hour burn-in test.
ESD protection: ESD precautions are mandatory during disassembly and assembly. The backplane connector has fine pins which are vulnerable to damage.
- Procurement Remarks
Market status: Siemens has ceased production of this model, no brand-new original factory stock. Available sources: new old stock, tested used pull-outs, repaired refurbished units.
Garantía: Refurbished units normally come with 12-month warranty; used pull-outs have shorter warranty. A load test report should be requested when purchasing.
- APtronic cV5_AC (A5E31006890-K9) Backplane Pinout & Power-up Sequence
This power supply uses proprietary Siemens backplane connector, not standard ATX. It includes multi-channel power pins, PG (Power Good) and power enable signal. Timing differs completely from ATX; standard ATX cannot be adapted directly.
Definición de PIN (Main Connector)
| Señal | Definición | Observaciones |
| AC-L / AC-N | AC Live / Neutral | 100~240VAC input |
| Tierra | Tierra eléctrica | Common ground for all output channels |
| +3.3V | 3.3V main output, max 8.5A | First voltage to ramp up |
| +5V | 5salida V, max 16.5A | Rises synchronously with +3.3V |
| +12V | 12salida V, max 6.5A | Establishes after +3.3V / +5V stabilizes |
| -12V | Negative 12V, 0.3A auxiliary output | Follows +12V |
| PS_ON | Power enable (activo bajo) | Controlled by motherboard via backplane; power off when floating / high level |
| PG / PWR_GOOD | Power Good signal (activo alto) | High level output after all outputs stabilize, to reset and boot the IPC motherboard |
Power-up Sequence (Critical for Repair & Substitution)
- AC mains applied, internal standby circuit activates
- +3.3V and +5V ramp up, reach regulation tolerance within 10~20ms
- +12V and -12V build up subsequently
- After all outputs stabilize, PG signal turns high with 100~500ms delay. Motherboard receives PG to complete reset and start CPU.
- Power-down sequence: On AC loss, +12V drops first; +3.3V / +5V maintain hold-up time. PG pulls low in advance to notify motherboard for data saving.
⚠️Risk warning: Even if multimeter shows normal DC voltages, mismatched PG timing may lead to failure to boot, repeated rebooting or blue screen.
- Tabla comparativa: cV4 / cV5_AC / cV5_DC
| Artículo | cV4 | cV5_AC (A5E31006890-K9) | cV5_DC |
| Siemens Order No. | A5E00102410 | A5E31006890-K9 | A5E31006891 |
| Tipo de entrada | AC 100-240V | AC 100-240V | CC 24 V |
| Potencia nominal | 110W. | 150W. | 150W. |
| Compatible IPC | IPC627A, IPC827A | IPC627B/C, IPC827B/C, HMI IPC677B/C | Same IPC models as cV5_AC, for DC-powered systems |
| Output Ratings | 3.3V/5V/12V/-12V | 3.3V 8.5A; 5V 16.5A; 12V 6.5A; -12V 0.3A | Identical current ratings as cV5_AC |
| Mechanical Form Factor | Same drawer module size | Same drawer module size | Vivienda idéntica; different backplane pin definition, no directamente intercambiables |
| Market Status | fin de vida, used spare parts | fin de vida, NOS / renovar / used | fin de vida |
| Intercambiabilidad | Not a direct replacement for cV5; different backplane pins & clasificación de potencia | K6/K7/K9 revisions of cV5_AC are hardware compatible; cannot swap with cV5_DC | Not interchangeable with AC version; different input circuit on backplane |
- cV5_AC Power Supply Repair & Second-hand Acceptance Test Checklist
Paso 1: Power-off Visual Pre-inspection (Safety Precondition)
- Discharge: Fully discharge high-voltage bulk capacitor to prevent electric shock or multimeter damage.
- Inspección visual: Check PCB for burn marks or component explosion; inspect electrolytic capacitors for bulging, cracked safety vent or electrolyte leakage.
- Conector: Check backplane pins for oxidation, doblando, breakage or corrosion; verify chassis ground integrity.
- Offline continuity test:
Check continuity of AC input fuse; open fuse → DO NOT power on before troubleshooting short circuit downstream.
Measur secondary outputs to ground to rule out short circuit (short to ground on 3.3V,5V,12V indicates breakdown of rectifier or capacitor).
Paso 2: No-load Power-on Test (No Load Connected)
- Apply AC 220V, short PS_ON pin to enable power supply.
- Measure each DC output with multimeter, reference tolerance:
+3.3V: 3.24~3.42V
+5V: 4.75~5.25V
+12V: 11.4~12.6V
-12V: -11.4~-12.6V
Nota: No-load voltage only for preliminary screening. Normal no-load reading ≠ functional under load.
Step3: Load Burn-in Test (Core Acceptance for Second-hand Units)
- Set electronic load to rated current: 3.3V(8.5A), 5V(16.5A), 12V(6.5A), load from 70% a 100% rating.
- Monitoring items:
- Voltage drop within tolerance on all channels
- Oscilloscope ripple measurement: 12V ripple<120mVpp, 5V<80mVpp, 3.3V<50mVpp. Excessive ripple is typical root cause for random blue screen and power drop-out.
- PG signal: Validate power-up delay under load; PG must not drop unexpectedly during load transient.
- Continuous burn-in: Minimum 2 hours full-load aging, monitor case temperature, no latch-off, no power loss, sin ruido anormal.
- Cold test (optional high-standard acceptance): Load test at 0~5℃ to reproduce intermittent faults.
Step4: Protection Function Verification
Protección contra cortocircuitos de salida: Temporary single-channel short triggers latch protection; power recovers after removing short and reboot.
Over-current / Over-voltage protection: PG de-asserts and power shuts down when output exceeds threshold.
Input under-voltage protection: Power fails to start if AC input below 90V.
Step5: Full Machine Integration Test
- Install power supply into target IPC (IPC627C / IPC827C etc.)
- Run system continuously for 4 hours under CPU stress test
- Check system event log for unexpected power loss, blue screen or hardware errors
- Perform multiple cold boot and warm reboot cycles to verify consistent power-up and motherboard recognition.
Common Component Replacement List for Repair
Secondary electrolytic capacitors (highest failure rate; replace all with 105℃ high-temperature industrial capacitors)
Primary high-voltage electrolytic capacitor
Input fuse, NTC thermistor
Secondary Schottky rectifier diodes
APtronic cV Series Drawer Modular IPC Power Supply Full Model List
For Siemens SIMATIC box IPC IPC627 / IPC827 / HMI IPC Panel PC. All manufactured by APtronic with Siemens A5E spare part numbers. All series are end-of-life, only used / NOS spare parts available.
Series branches: cV4, cV5_AC, cV5_DC. Same drawer housing, but input circuit and backplane pins are NOT universal.
- cV4 Series (110W., AC input, legacy model for IPC627A/IPC827A)
| Internal Model | Siemens Order No. | Revisión | Aporte | Fuerza | Observaciones |
| cV4 | A5E00102410 | – | CA100-240V | 110W. | First generation cV, cannot replace cV5 directly, different backplane connector |
- cV5_AC Series (150W AC input, your referenced A5E31006890-K9 belongs here)
| Internal Model | Siemens Order No. | Hardware Revision | Aporte | Fuerza | Modelos compatibles & Observaciones |
| cV5_AC | A5E02625806 | K6 | 100–240 V CA | 150W. | IPC627B/C, IPC827B/C, HMI IPC677B/C; early K6 revision |
| cV5_AC | A5E02625806 | K7 | 100–240 V CA | 150W. | K7, hardware compatible with K6/K9, plug-and-play intercambiables |
| cV5_AC | A5E31006890 | K9 | 100–240 V CA | 150W. | Latest revision, widely circulated on market, tu modelo objetivo |
✅Interchange rule: K6/K7/K9 revisions within cV5_AC series are fully hardware compatible and plug-and-play. Different order numbers only indicate production batch revisions
- cV5_DC Series (150W DC24V input, same housing as cV5_AC, not directly interchangeable with AC version)
| Internal Model | Siemens Order No. | Hardware Revision | Aporte | Fuerza | Modelos compatibles & Observaciones |
| cV5_DC | A5E30947477 | H3 | CC 24 V | 150W. | IPC627B/C, IPC827B/C, HMI IPC677B/C; H3 revision |
| cV5_DC | A5E30947477 | H4 | CC 24 V | 150W. | H4 revised version; H3/H4 interchangeable within DC series |
| cV5_DC | A5E02625805 | H2 | CC 24 V | 150W. | Old order number, upgraded substitute: A5E30947477-H4 |
| cV5_DC | A5E01231722 | F2 | CC 24 V | 150W. | Early F2 revision, fin de vida, H4 is replacement |
Upgrade Cross-reference Table (Critical for Spare Part Selection)
- A5E00827436-H3 → Upgrade substitute: A5E31006890-K9 (cV5_AC)
- A5E02625805-H2 → Upgrade substitute: A5E30947477-H4 (cV5_DC)
- A5E01231722-F2 → Upgrade substitute: A5E30947477-H4 (cV5_DC)
Key Interchangeability Summary
- cV4 ≠ cV5: No intercambiables, different power rating and backplane pin assignment.
- cV5_AC ↔ cV5_DC: Identical mechanical housing, but different input circuit and backplane pin definition. Never swap directly.
- Same model different revisions (K6/K7/K9, H3/H4): Plug-and-play replacement without rewiring.
- Output specifications: All cV5 (AC/DC) have identical multi-channel DC output parameters; only input power type differs.
Extended Note on Next-generation cV6 Series (For Distinction, not part of cV5)
cV6 is successor drawer power supply with same form factor, but brand new order numbers. Designed for IPC627D/IPC827D, not compatible with cV5, generally separated from cV5 family.
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor



















NH42-63-318x560.png)