Relé de seguridad Wieland SNA-4053-K-A - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Relé de seguridad Wieland SNA-4053-K-A - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Relé de seguridad Wieland SNA-4053-K-A

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, safety light curtains) 4053: Specification code K: Pluggable screw terminals A: Supply voltage AC/DC 24 V Suffix differentiation for the series: A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version Core Specifications & Safety Ratings ...

  • Detalles del producto

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, safety light curtains)

4053: Código de especificación

k: Pluggable screw terminals

A: Supply voltage AC/DC 24 V

Suffix differentiation for the series:

A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version

  1. Especificaciones principales & Safety Ratings
  2. Certificaciones de seguridad

pl y / Categoría 4 (EN ISO 13849-1)

SIL CL3 (EN 62061)

  1. Configuración de contacto

3 safety normally open contacts (13-14 / 23-24 / 33-34)

1 normally closed signal contact (41-42)

  1. Datos eléctricos

Suministrar: 24 VCA/CC

Continuous rated current Ith: 8 A

AC-15: 230 V / 5 A; DC-13: 24 V / 5 A

Montaje: DE 35 carril mm; Ancho 22.5 milímetros

  1. Input Functions

Dual-channel safety circuit (S11/S12, S21/S22)

Supports cross-channel short-circuit monitoring

Reinicio manual (with reset monitoring)

Adecuado para: Emergency stop buttons, safety gate switches, magnetic safety switches, safety light curtains

  1. Typical Wiring Logic
  2. A1(+), A2(-): 24 V fuente de alimentación
  3. S11-S12, S21-S22: Dual-channel safety devices (normally closed signal)
  4. S33-S34: Reset terminals (connect external normally open reset button; shorted = automatic reset)
  5. 13-14 / 23-24 / 33-34: Salidas de seguridad (for controlling main contactors)
  6. 41-42: Normally closed fault feedback signal
  7. Model Correction & Alternative Reference

⚠️ The most frequently confused model on the market: SNA4043K-A (4043, easily mistaken for 4053)

⚠️ Important Verification Conclusion

SNA4053K-A is NOT an official standard model in Wieland catalogues, it is highly likely a transcription error:

  1. Most common miswriting: SNA4043K-A (Número de pieza. R1.188.1810.0)

Reinicio automático, no reset monitoring; dual-channel with short-circuit monitoring

  1. Alternative similar model: SNA4063K-A

Reinicio manual (with reset monitoring) — this is the core difference from SNA4043

Model rules:

SNA4043K-A: Reinicio automático

SNA4063K-A: Reinicio manual (reset button monitoring)

Both models share identical contact configuration, safety rating and dimensions; only reset logic differs.

Quick Selection Comparison Table

ModeloManufacturer Part No.Voltaje de suministroModo de reinicioTipo de terminal
SNA4043K‑AR1.188.1810.0AC/DC 24 VReinicio automáticoPluggable screw K
SNA4063K‑AR1.188.1870.0AC/DC 24 VReinicio manual (with reset monitoring)Pluggable screw K

Recommended Actions

  1. Verify the printed model on the physical nameplate of the unit;
  2. Confirm site requirements: Reset monitoring required or not

Emergency stop circuits generally require manual reset (SNA4063K-A)

Safety light curtain applications may adopt automatic reset (SNA4043K-A)

Application Scenarios of Wieland SNA Series Relés de seguridad (SNA4043 / SNA4063)

This series achieves PL e / Cat.4 / SIL3 with dual-channel monitoring, primarily deployed for safety circuits on machine tools and automated production lines. Content is divided into supported safety signal types, industry applications, and key selection differentiation.

  1. Supported Safety Input Signals (Hardware Utilization)
  2. Emergency stop buttons (dual normally closed contacts)

Most common application: Machine main emergency stop and zone emergency stop circuits.

Standard requirement: Emergency stop circuits prefer SNA4063K-A (manual reset with monitoring).

  1. Safety gate switches / Magnetic safety sensors

Interlock for protective doors, maintenance doors and perimeter fencing; power circuit cutout upon door opening.

  1. Safety light curtains

Hazard zone intrusion protection for presses, conveyor lines and robot stations.

Light curtain solutions commonly use SNA4043K-A (reinicio automático).

  1. Two-hand control devices

For stamping and riveting equipment, preventing single-hand access to hazardous zones.

  1. Safety mats, safety bumpers

Perimeter intrusion detection around robot cells, automatic doors and lifting platforms.

  1. Major Industry & Equipment Applications

(1) Industria de máquinas herramienta

CNC lathes, machining centres, muelas, punching machines, maquinas dobladoras

Solicitud: Protective door interlock, emergency stop circuits, safety light curtain protection

(2) Automated Production & Equipo de embalaje

Máquinas de embalaje, palletizers, líneas transportadoras, sorting equipment, labellers

Robot workstations, gantry robot safety fence interlock

(3) Goma & Plastics Industry

Injection moulding machines, extrusoras, blow moulding equipment: Safety gates, parada de emergencia, safety light curtains

(4) Logística & Warehousing Equipment

Automated warehouses, lifts, lanzaderas, líneas de clasificación

Plataformas elevadoras, dock leveller safety interlocks

(5) Nueva energía & Equipo de batería de litio

Cell assembly machines, electrolyte filling machines, sealing equipment, test tooling

Wieland products are widely adopted on export machinery to meet EU CE Machinery Directive requirements

(6) carpintería & Maquinaria de impresión

Panel saws, maquinas de corte, printing presses, die-cutting machine safety protection

(7) Automatización personalizada general

Custom test fixtures and assembly machines; deployed as core safety logic unit to cut off main contactors and servo power circuits.

  1. Critical Application Selection Comparison
ModeloModo de reinicioAplicación típica
SNA4043K‑AReinicio automáticoSafety light curtains, safety bumpers; system enables restart automatically after obstacle removal
SNA4063K‑AReinicio manual (with reset monitoring)Emergency stop buttons, safety gate switches. Manual reset operation is mandatory before machine restart (required by machinery safety standards)

⚠️ SNA-4053-K-A is not an official Wieland standard model. It is almost certainly a nameplate transcription error; physical unit will be one of the two above variants.

  1. Limitaciones & Aplicaciones inadecuadas
  2. Cannot directly drive high-power loads; safety contacts are intended to control contactor coils, not motors directly
  3. Not suitable for solenoid valves or high-frequency switching loads
  4. Cannot satisfy safety requirements higher than PL e / Cat.4 (this series already reaches Cat.4 maximum rating)

Selection Guidelines for Wieland SNA / SNO Safety Relays

Based on the SNA4043 / SNA4063 platform covered above; structured criteria ready for engineering proposals and procurement checks.

Paso 1: Confirm Required Safety Rating (Mandatory Priority)

Cumple con ISO 13849-1 / EN 62061

  1. PL & Categoría

pl y / Cat.4: Highest rating. For high-risk stations including robots, stamping, injection moulding, machine tools and lithium battery equipment (supported by all mainstream SNA variants)

pl d / Cat.3: Low-risk general automation and conveyor lines

  1. Nivel SIL

SIL 3 corresponds to PL e; preferred for machinery exported to EU

✅ Selection Rule: Do NOT downgrade safety rating for high-risk equipment.

Paso 2: Determine Safety Input Channel Configuration (Dual Channel Is Standard)

Channel Modes

Dual-channel monitoring with cross short-circuit detection: Industry standard, fitted across all SNA variants. Compatible with dual normally closed safety devices (Molestar, safety gates, light curtains)

Single channel: Only permitted for low-risk scenarios; available on selected SNO variants. NOT allowed for high-risk machinery.

Compatible Sensor Types

Emergency stop switches, mechanical safety gates: Dual normally closed (CAROLINA DEL NORTE)

Magnetic safety switches, safety light curtains: Dual NC / OSSD signals

⚠️ Two types of safety light curtains:

① OSSD solid-state output → Requires relay model supporting OSSD input

② Light curtain with relay converted contact output → Compatible with standard SNA4043 / SNA4063

Paso 3: Modo de reinicio (Most Common Source of Wrong Selection!)

Reset TypeEjemplo de modeloSolicitudCompliance Note
Reinicio automáticoSNA4043K‑ASafety light curtains, safety bumpers, safety mats; system ready after obstacle clearedFORBIDDEN for emergency stop and safety gate circuits
Reinicio manual (with reset line monitoring)SNA4063K‑AEmergency stop buttons, machine protective safety gates; manual reset push required before restartMandatory recommendation per machinery safety standards; preferred for most complete machinery

Distinción clave:

Monitored reset detects open or short circuits on reset wiring and triggers safety lockout for superior safety. Simple unmonitored manual reset should be avoided on new projects.

Paso 4: Voltaje de suministro

Main Wieland options:

Suffix A = AC/DC 24 V (Automation standard, selected in 90% of projects)

Less common: 110 VACACIONES, 230 VAC — only for legacy retrofits

Ejemplo: SNA4063K-A → A = AC/DC 24 suministro V

Paso 5: Tipo de terminal (Identified by Suffix K / do)

K = Pluggable screw terminals

Ventajas: Resistente a vibraciones, ideal for permanent cabinet installation and on-site maintenance (the unit in your photo uses K terminals)

C = Push-in spring terminals

Ventajas: Fast wiring without screwdrivers; use cautiously under heavy vibration

Ejemplo: SNA4063K-A

Paso 6: Output Contact Configuration

Main Safety Outputs (For Power Circuit Cutoff)

SNA4043 / SNA4063: 3 contactos de seguridad normalmente abiertos

Objetivo: Wired in series with main contactor coils for redundant shutdown

Auxiliary Signal Contacts (PLC Feedback)

1 built-in normally closed fault contact

Opens upon safety activation or relay fault; used for alarm indicators and PLC signalling

Nota de selección: If multiple feedback signals are required, add auxiliary relays. Safety contacts should not be expanded externally.

Contact Load Ratings

AC-15: 230 V / 5 A

DC-13: 24 V / 5 A

👉 Never drive motors directly; only control contactor coils!

Paso 7: Montaje & Especificaciones físicas

  1. Montaje: Standard DIN 35 carril mm
  2. Ancho: SNA40xx series 22.5 milímetros, compact design saving cabinet space
  3. Environmental rating: IP20 (solo para instalación en gabinete; not for outdoor direct deployment)

Paso 8: Differentiate SNA vs SNO Series (Frequent Confusion)

SNA Series: Dual-channel safety monitoring, up to PL e Cat.4; for emergency stop, safety gates, light curtains (your target series)

SNO Series: Predominantly single channel, lower safety rating generally PL d and below; low-cost basic solutions

Common Selection Pitfalls Checklist

  1. ❌ Misapplication: Using automatic reset SNA4043 for emergency stop circuits — violates machinery safety standards, fails third-party audit & Certificación CE
  2. ❌ Transcription error SNA-4053-K-A: No official model; physical unit is either SNA4043 or SNA4063
  3. ❌ Direct drive of solenoid valves or high-power loads with safety contacts → contact burnout and loss of safety function
  4. ❌ Mixing K screw terminals and C spring terminals, leading to mismatch on delivery
  5. ❌ Ignoring reset monitoring requirements → machine fails acceptance testing

Rapid Selection Workflow (For Field Engineers)

  1. Identify safety device: parada de emergencia / safety gate → select SNA4063xx-A (monitored manual reset); Light curtain / safety bumper → SNA4043xx-A (reinicio automático)
  2. Confirm supply voltage: Default AC/DC24V suffix A
  3. Select terminal type: Permanent cabinet installation → K screw terminal; high volume assembly for fast wiring → C spring terminal
  4. Verify safety rating: High-risk equipment requires PL e / Cat.4 / SIL3
  5. Confirm number of safety contacts sufficient for contactor control

Complete Official Model List of Wieland SNA40xx Safety Relays

Series Profile: safeRELAY SNA40xx dual-channel safety monitoring, pl y / Cat.4 / SIL3, Montaje en carril DIN;

⚠️ Aviso importante: SNA-4053-K-A is NOT an official Wieland model, it is a transcription error. Official core variants are limited to 4043 / 4044 / 4063 / 4064;

Industry standard: Suffix A = AC/DC24 V (automation default). Specify A suffix for new orders.

  1. Reglas de nomenclatura de modelos

`SNA 40XX [Terminal][Reiniciar]-[Voltage Suffix]`

  1. SNA: Dual-channel safety monitoring base unit
  2. 40XX:

4043: 3 contactos NA de seguridad, reinicio automático (no reset monitoring)

4044: 4 contactos NA de seguridad, reinicio automático (no reset monitoring)

4063: 3 contactos NA de seguridad, reinicio manual (with reset circuit monitoring)

4064: 4 contactos NA de seguridad, reinicio manual (with reset circuit monitoring)

Last digit 3 = 3 contactos NA de seguridad; Last digit 4 = 4 contactos NA de seguridad

  1. Terminal Code

k: Pluggable screw terminals (most widely used in projects)

do: Pluggable Push-in spring terminals

  1. Extended Reset Suffix (KM/KE)

km: Simple manual reset without monitoring; rarely specified for new projects

  1. Voltage Suffix

A: AC/DC 24 V (automation standard)

Sin sufijo: Fixed screw terminals (legacy models, eliminado gradualmente)

  1. Mainstream Models for Domestic Projects (24 VCA/CC)

SNA4043 Series | Reinicio automático, 3 Safety NO Contacts

Modelo completoWieland Part No.Tipo de terminalConfiguración de contactoModo de reinicioAplicación típica
SNA4043K‑AR1.188.1810.0Pluggable screw K3 Safety NO + 1 NC Fault ContactReinicio automático (no reset monitoring)Safety light curtains, safety bumpers, safety mats
SNA4043C‑AR1.188.1940.0Push‑in spring C3 Safety NO + 1 NC Fault ContactReinicio automático (no reset monitoring)High volume cabinet fast wiring

SNA4044 Series | Reinicio automático, 4 Safety NO Contacts

Modelo completoWieland Part No.Tipo de terminalConfiguración de contactoModo de reinicioAplicación típica
SNA4044K‑AR1.188.1860.0Pluggable screw K4 Safety NO + 1 NC Fault ContactReinicio automático (no reset monitoring)Applications requiring multiple safety cutout circuits, light curtain systems
SNA4044C‑AR1.188.1960.0Push‑in spring C4 Safety NO + 1 NC Fault ContactReinicio automático (no reset monitoring)Synchronous cutout of multiple contactors

SNA4063 Series | Reinicio manual (Monitored), 3 Safety NO Contacts【Preferred for Complete Machinery】

Modelo completoWieland Part No.Tipo de terminalConfiguración de contactoModo de reinicioAplicación típica
SNA4063K‑AR1.188.1440.0Pluggable screw K3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringEmergency stop buttons, machine safety gates, CE certified machinery (Most Popular)
SNA4063C‑AR1.188.1950.0Push‑in spring C3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringExport custom automation, fast cabinet wiring

SNA4064 Series | Reinicio manual (Monitored), 4 Safety NO Contacts

Modelo completoWieland Part No.Tipo de terminalConfiguración de contactoModo de reinicioAplicación típica
SNA4064K‑AR1.188.1880.0Pluggable screw K4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringMulti‑group power circuit cutout, large machine tools
SNA4064C‑AR1.188.1970.0Push‑in spring C4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringSystems requiring synchronous shutdown of multiple contactors
  1. Legacy Non-Standard Voltage Models (Only For Equipment Replacement, Not Recommended For New Projects)

Fixed non-pluggable screw terminals (no suffix A)

SNA4043K: AC42~48 V / AC115 V / AC230 V

SNA4063K: AC230 V

Nota: All new domestic machinery shall adopt AC/DC24 V models with suffix -A

  1. General Specifications Applicable to All Variants
  2. Clasificación de seguridad: pl y / Cat.4, SIL 3 (EN ISO13849-1, EN62061)
  3. Calificaciones de contacto: AC-15 230 V/5 A; DC-13 24 V/5 A
  4. Montaje: DE 35 carril mm; Ancho 22.5 milímetros; IP20 (Cabinet installation only)
  5. Características: Dual-channel cross short-circuit monitoring, EDM external device monitoring support, 3 status LED indicators
  6. Alambrado: Supports single-channel / dual-channel connection modes
  7. Quick Selection Summary Table
Model GroupModo de reinicioCompatible Safety DevicesCompliance Restriction
SNA4043 / SNA4044Reinicio automáticoSafety light curtains, safety bumpers❌ NOT permitted for emergency stop and machine safety gate circuits
SNA4063 / SNA4064Reinicio manual (Monitored)Emergency stop switches, safety gate switches✅ Compliant with EN60204 machinery safety standards, accepted for CE audits
  1. Procurement Reminders
  2. If customer submits model `SNA-4053-K-A` → Confirm transcription error immediately. Check physical nameplate; the actual unit is almost certainly SNA4063K-A.
  3. Always include complete model + manufacturer part number in BOM to avoid delivery mismatch between K screw terminals and C spring terminals.
  4. Do not interchange automatic reset SNA4043 and monitored manual reset SNA4063; incorrect selection will lead to failed safety acceptance.
  5. Contact count selection: 3 contactors or less → SNA4063; ≥4 contactors requiring synchronous shutdown → select SNA4064.

Anterior:

Deja una respuesta