Core Difference Analysis between P3U30-5AAA2BBAA and P3U30-5AAA2BBAC Both models belong to the Schneider PowerLogic/Easergy P3U30 Series Universal Protection Relay. The core difference lies only in the last two characters (AA vs AC).

Both models belong to the Schneider PowerLogic/Easergy P3U30 Series Universal Protection Relay. The core difference lies only in the last two characters (AA vs AC). The complete structure analysis is as follows:

Segment de modèleSignificationP3U30-5AAA2BBAAP3U30-5AAA2BBAC
P3U30Série de produitsUniversal Protection Relay (P3U30)Universal Protection Relay (P3U30)
5Power Supply Type48-230V CA/CC48-230V CA/CC
AAAMeasurement Input3CT (1/5UN), 1Io (1/5UN), 4Vermont (100V/110V)3CT (1/5UN), 1Io (1/5UN), 4Vermont (100V/110V)
2Configuration des E/S16D/8C (with watchdog)16D/8C (with watchdog)
BBModule de communicationBasic communication configurationBasic communication configuration
AA/ACTension d'entrée numérique + Interface de communicationAA: DI=220V AC/DC, RS485 serial port onlyCA: DI=110-230V AC/DC, Deux ports Ethernet RJ45 + RS485
  1. Key Specification Comparison Table
Catégorie de paramètreP3U30-5AAA2BBAAP3U30-5AAA2BBACImpact of Difference
Standard REL CodeREL52002REL52008Official material code distinction
Entrée numérique (DEPUIS)16 chaînes, 220V CA/CC16 chaînes, 110-230V CA/CCAC version has wider voltage range for more application scenarios
Interface de communication1×RS485 Serial Port (Modbus RTU / CEI 60870-5-101/103)2×RJ45 Ethernet Ports (CEI 61850 / Modbus-TCP) + 1×RS485 Serial PortAC version supports Ethernet communication for system network integration
Protocole de communicationSerial protocols only (no Ethernet)All serial protocols + Ethernet protocols (CEI 61850 Ed.1/Ed.2, DNP3, Ethernet/IP)AC version complies with modern industrial Ethernet standards
Type de connexionBornes à visBornes à vis + Dual RJ45 portsAC version facilitates network wiring and remote monitoring
Other Core ParametersIdentique: 3CT phase current input (1/5UN), 1Io residual current input (1/5UN), 4VT voltage input (100V/110V), 8FAIRE (with watchdog), 48-230V AC/DC power supplyIdentiqueBasic protection functions are fully consistent
  1. Detailed Description of Differences

3.1 Digital Input Voltage Difference

P3U30-5AAA2BBAA (REL52002): Fixed digital input of 220V AC/DC, suitable for standard industrial control voltage environments.

P3U30-5AAA2BBAC (REL52008): Wide-range digital input of 110-230V AC/DC, compatible with more international standard voltages with higher flexibility.

3.2 Communication Capability Difference (Core Distinction)

P3U30-5AAA2BBAA: Equipped with only RS485 serial communication, suitable for simple point-to-point communication; does not support network integration or remote monitoring.

P3U30-5AAA2BBAC: Equipped with dual RJ45 Ethernet ports + RS485 serial port, justificatif:

Redundant Ethernet communication (RSTP/PRP protocol)

CEI 61850 substation communication standard (Ed.1/Ed.2)

Modern industrial protocols such as Modbus TCP, DNP3, Ethernet/IP

Remote configuration, monitoring and firmware upgrade

3.3 Application Scenario Adaptation

Scénario d'applicationModèle recommandéRaison
Traditional Substation (No network requirement)P3U30-5AAA2BBAACoût inférieur, meets basic communication needs
Smart Substation / Industrial IoTP3U30-5AAA2BBACSupports IEC 61850 for easy system integration
International Projects / Multi-voltage EnvironmentP3U30-5AAA2BBACWide-range DI voltage adapts to different national standards
Surveillance à distance & Diagnostics RequirementP3U30-5AAA2BBACEthernet enables remote access
Cost-Sensitive ProjectsP3U30-5AAA2BBAAEnviron 10-15% lower price than AC version
  1. Recommandations de sélection
  2. Communication Requirement Judgment

Local communication or simple SCADA connection only: Choose AA version (REL52002)

CEI 61850, remote monitoring or network redundancy required: Must choose AC version (REL52008)

  1. Digital Input Voltage Adaptation

System unified with 220V control voltage: AA version fully compatible

Mixed 110V/220V control voltage or uncertain future demands: Choose AC version with wide-range input

  1. Extensibilité future

The dual Ethernet port design of AC version reserves space for future system upgrades and supports advanced smart grid applications.

  1. Supplementary Information

Compatibilité matérielle: Both models have identical physical dimensions and mounting methods, enabling direct interchangeable installation.

Fonctions de protection: Both provide more than 40 protection functions including overcurrent, défaut à la terre, sous-tension, phase sequence reversal, etc., meeting feeder and motor protection requirements.

Certifications: Both comply with international standards such as IEC 60255 and EN 61850 for global market application.

Communication Interface Difference: P3U30-5AAA2BBAA vs P3U30-5AAA2BBAC

P3U30-5AAA2BBAA has only an RS485 serial port without Ethernet; P3U30-5AAA2BBAC retains RS485 and adds dual RJ45 Ethernet ports to support network communication.

  1. Detailed Communication Interface Comparison
ArticleP3U30-5AAA2BBAAP3U30-5AAA2BBAC
Physical Network PortNo RJ45 Ethernet port2-channel RJ45 Ethernet ports
Serial Interface1-channel RS485 terminal1-channel RS485 terminal (retained same as AA version)
Communication HardwareSerial communication hardware onlyDual hardware: En série + Ethernet
Supported ProtocolsSerial protocols only:All serial protocols + Ethernet protocols:
Modbus RTU, CEI 60870-5-101/103Modbus-TCP, CEI 61850, DNP3, etc..
Networking CapabilityOnly RS485 bus networkingSupports Ethernet star/ring/redundant networking and dual-port cascading
Télécommande / Smart SubstationNo Ethernet remote access, no IEC61850 supportSupports remote network access and IEC61850 smart substation standard
  1. Key Difference Summary
  2. AA Version: Pure serial port type

Only RS485 interface, limited to traditional RS485 bus networking; cannot connect to switches, access Ethernet, or support IEC61850.

  1. AC Version: Hybrid type with serial port + dual Ethernet ports

Retains the original RS485 interface and adds 2 RJ45 ports, which can be directly connected to industrial switches, form ring networks, and support IEC61850 & Modbus TCP network communication.

  1. Simple Selection Rule

Only RS485 communication for traditional cabinet internal connection → Choose P3U30-5AAA2BBAA

Require Ethernet, remote networking, smart substation or IEC61850 → Must choose P3U30-5AAA2BBAC

Schneider PowerLogic P3U30 Series Universal Protection Relay Model List

  1. Règle de codage du modèle (Full Interpretation)

The P3U30 series adopts the format P3U30-XXXXXXXX with 14 characters. The definition of each segment is as follows:

Segment de modèlePositionSignificationCode facultatif & Description
P3U301-5Série de produitsP3U30 = Universal Protection Relay for feeder and motor protection
5月6日6Power Supply Type5 = 48-230V AC/DC
6 = 24-48V AC/DC
AAA/ABA7-9Measurement Input ConfigurationAAA = 3CT(1/5UN), 1Io(1/5UN), 4Vermont(100V/110V)
ABA = 4L (3CT+1Io) ring-type terminal, 4Vermont(100V/110V)
1月2日10Configuration des E/S1 = 16DI/4DO (without watchdog)
2 = 16DI/8DO (with watchdog)
BB/BD/BC11-12Basic Communication ConfigurationBB = Basic communication
BD = Extended communication
BC = Advanced communication
AA/AC/BA/CA13-14Tension d'entrée numérique + Interface de communicationAA = DI=220V AC/DC, RS485 only
AC = DI=110-230V AC/DC, Double RJ45 + RS485
BA = DI=24-48V AC/DC, RS485 only
CA = DI=24-230V AC/DC, Double RJ45 + RS485
  1. Liste complète des modèles (Classified by Communication Interface)

2.1 RS485 Serial Communication Only (Without Ethernet)

ModèleREL CodeAlimentationMeasurement InputConfiguration des E/SDI VoltageInterface de communicationScénario d'application
P3U30-5AAA2BBAAREL5200248-230V CA/CC3CT+1Io+4VT16D/8C (with watchdog)220V CA/CC1×RS485Traditional substation, local communication
P3U30-5AAA2BBBAREL5200348-230V CA/CC3CT+1Io+4VT16D/8C (with watchdog)24-48V CA/CC1×RS485Low-voltage control system, PLC interlocking
P3U30-6AAA2BBAAREL5200424-48V CA/CC3CT+1Io+4VT16D/8C (with watchdog)220V CA/CC1×RS485DC system, battery-powered
P3U30-6AAA2BBBAREL5200524-48V CA/CC3CT+1Io+4VT16D/8C (with watchdog)24-48V CA/CC1×RS485Petit matériel, low-power application
P3U30-5ABA1BBAAREL5200648-230V CA/CC4L ring type + 4Vermont16DI/4DO (without watchdog)220V CA/CC1×RS485Feeder protection, configuration simplifiée
P3U30-6ABA1BBAAREL5200724-48V CA/CC4L ring type + 4Vermont16DI/4DO (without watchdog)220V CA/CC1×RS485Distributed system, remote terminal unit

2.2 Dual RJ45 Ethernet + RS485 Communication (Smart Type)

ModèleREL CodeAlimentationMeasurement InputConfiguration des E/SDI VoltageInterface de communicationScénario d'application
P3U30-5AAA2BBACREL5200848-230V CA/CC3CT+1Io+4VT16D/8C (with watchdog)110-230V CA/CC2×RJ45+1×RS485Smart substation, CEI 61850
P3U30-5AAA2BBCCREL5200948-230V CA/CC3CT+1Io+4VT16D/8C (with watchdog)24-230V CA/CC2×RJ45+1×RS485International projects, multi-voltage compatibility
P3U30-6AAA2BBACREL5201024-48V CA/CC3CT+1Io+4VT16D/8C (with watchdog)110-230V CA/CC2×RJ45+1×RS485DC smart system, surveillance à distance
P3U30-6AAA2BBCCREL5201124-48V CA/CC3CT+1Io+4VT16D/8C (with watchdog)24-230V CA/CC2×RJ45+1×RS485IoT integration, prise en charge multiprotocole
P3U30-5ABA1BDACREL5201248-230V CA/CC4L ring type + 4Vermont16DI/4DO (without watchdog)110-230V CA/CC2×RJ45+1×RS485Feeder automation, network redundancy
P3U30-6ABA1BDACREL5201324-48V CA/CC4L ring type + 4Vermont16DI/4DO (without watchdog)110-230V CA/CC2×RJ45+1×RS485Distributed feeder protection, CEI 61850

2.3 Special Configuration Models (Wide Temperature / Fonctions étendues)

ModèleREL CodeFonctionnalités spécialesInterface de communicationRemarques
P3U30-5AAA2BBAA-WREL52045Wide temperature (-25°C~+70°C)1×RS485Outdoor application, harsh environment
P3U30-5AAA2BBAC-WREL52046Wide temperature (-25°C~+70°C)2×RJ45+1×RS485Smart outdoor equipment, diagnostic à distance
P3U30-5ABA2BDAAREL520474L ring terminal, extended I/O1×RS485High-current measurement, industrial monitoring
P3U30-5ABA2BDACREL520484L ring terminal, extended I/O2×RJ45+1×RS485Smart grid, feeder automation
  1. Key Parameter Overview Comparison
Catégorie de paramètreRS485 Only ModelsEthernet + RS485 ModelsCommon Features
Protocoles de communicationModbus RTU, CEI 60870-5-101/103Serial protocols + CEI 61850, Modbus-TCP, DNP3, Ethernet/IPAll support basic serial protocols
Networking CapabilityRS485 bus only, point-to-point / bus topologyEthernet star/ring/redundancy (RSTP/PRP), dual-port cascadingSupport standard industrial networking modes
Entrée numériqueTwo fixed voltages: 220V / 24-48VWide-range voltage: 110-230V / 24-230V16 channels with optical isolation
Sortie numérique4FAIRE / 8FAIRE (watchdog optional)4FAIRE / 8FAIRE (watchdog optional)Relay output, contact rating 5A/250V AC
Précision des mesuresClasse 0.2 (Courant/Tension), Classe 0.5 (Pouvoir)Classe 0.2 (Courant/Tension), Classe 0.5 (Pouvoir)Conforme à la CEI 60255
Fonctions de protection40+ protections (surintensité, défaut à la terre, sous-tension, etc.)40+ protections (surintensité, défaut à la terre, sous-tension, etc.)Suitable for feeder and motor protection
Power Supply Range24-48V or 48-230V AC/DC24-48V or 48-230V AC/DCWide voltage design for global power grid adaptation
  1. Quick Selection Chart (By Core Requirement)
Core RequirementModèle recommandéKey Advantages
Traditional substation without network demandP3U30-5AAA2BBAALow cost, meets basic communication
Smart substation with IEC 61850P3U30-5AAA2BBACDual Ethernet ports, supports IEC 61850 Ed.1/Ed.2
International project with multi-voltage environmentP3U30-5AAA2BBCC24-230V wide-range DI, global compatibility
DC system with battery power supplyP3U30-6AAA2BBAA24-48V power supply, faible consommation d'énergie
Outdoor application & harsh environmentP3U30-5AAA2BBAC-WConception à large température, forte anti-interférence
High-current measurement with ring terminalsP3U30-5ABA2BDAC4L ring terminals compatible with high-current CT
  1. Supplementary Information
  2. Compatibilité matérielle: All P3U30 models share identical physical dimensions (96×96×75mm) and mounting methods (Rail DIN / montage sur panneau) for direct interchangeable installation.
  3. Fonctions de protection: All models offer 40+ protection functions including overcurrent (je>>), défaut à la terre (Ig), sous-tension (U<), phase sequence reversal, surcharge, etc., complying with IEC 60255 standard.
  4. Certifications: Compliant with CE, UL, ASC, CEI 61850 and other international certifications for global market use.
  5. Mise à niveau du micrologiciel: Ethernet models support remote firmware upgrade; RS485 models require local upgrade.
  6. Liste des accessoires:

Front Connector: Standard 9-pin spring terminal

Communication Cable: RS485 shielded twisted pair (facultatif)

Ethernet Cable: CAT5e/CAT6 industrial Ethernet cable (Ethernet models only)

Précédent:

Suivant:

Laisser une réponse

Laisser un message