Emerson Rosemount 6R8HCI-58-C - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Emerson Rosemount 6R8HCI-58-C

6R8HCI-58-C is a combined model of Emerson Rosemount 68 Series Single-Element Platinum RTD Temperature Sensor and 58C Series Cut-to-Fit Sheath. It is specially designed for industrial process temperature measurement, adopting a Pt100 thin-film element with multiple mounting options. Suitable for the temperature range of -58°F to 392°F (-50°C to 200°C).

Emerson Rosemount 6R8HCI-58-C Platinum Resistance Temperature Sensor (RDT) PDF

6R8HCI-58-C is a combined model of Emerson Rosemount 68 Series Single-Element Platinum RTD Temperature Sensor and 58C Series Cut-to-Fit Sheath. It is specially designed for industrial process temperature measurement, adopting a Pt100 thin-film element with multiple mounting options. Suitable for the temperature range of -58°F to 392°F (-50°C to 200°C).

  1. Model Segment Definition
SegmentSignificationDescription détaillée
6Sensor Series68 Series single-element RTD (6 = single-element; 8 = thin-film type)
R8Resistance & Classe de précisionR = 100Ω (Pt100); 8 = Class B accuracy (±0.3°C @ 0°C)
HSheath MaterialH = 316 Acier inoxydable (Standard SST), corrosion-resistant for most industrial environments
CConnection Head TypeC = Polypropylene connection head, excellent insulation and chemical corrosion resistance
jeLead ConfigurationI = 3-wire system, effectively compensates lead wire resistance and improves measurement accuracy
-58Plage de température-58°F to 392°F (-50°C to 200°C), matched with 58C series sheath
-CSheath Series58C Series Cut-to-Fit sheath; length can be trimmed with standard pipe cutters on site
  1. Core Specification Parameters
Catégorie de paramètreTechnical IndexRemarques
Basic Characteristics
Type de produitSingle-element Platinum Resistance Temperature Sensor (RDT)68 Series thin-film type, 58C Series cut-to-fit sheath
MarqueEmerson RosemountBenchmark brand in industrial process measurement
Resistance ElementPt100 (100Ω @ 0°C) thin-film typeFast response and high long-term stability
Classe de précisionClasse B (CEI 60751)±0.3°C @ 0°C, ±0.004°C/°C above 0°C
Plage de température-58°F to 392°F (-50°C to 200°C)Temperature limit of 58C series sheath
Spécifications électriques
Lead Configuration3-filEliminates lead resistance influence and improves measuring accuracy
Lead MaterialPTFE insulated, silver-plated copper, 24AWG stranded wireTemperature resistant, chemical resistant and high conductivity
Résistance d'isolation≥1000MΩ @ 500Vdc (room temperature)Ensures integrity of measurement signal
Temps de réponse12 secondes (63.2% response in 3ft/s water flow)Fast response for thin-film element
Spécifications physiques
Sheath Material316 Acier inoxydableHigh corrosion resistance and mechanical strength
Sheath Diameter0.25 inch (6.35mm)Standard size, compatible with most thermowells
Sheath LengthStandard lengths: 12″, 24″, 36″, 48″Trimmable to any length, no need to stock multiple sizes
Connection Head MaterialPolypropyleneSuperior insulation and chemical resistance
Terminal Design6-terminal configurationEasy wiring and compatible with various transmitters
Conditions environnementales
Température de fonctionnement-58°F to 392°F (-50°C to 200°C)Limited by 58C sheath temperature rating
Humidity Resistance100% humidité relativeLead sealing withstands high-humidity environments
Résistance aux vibrations±0.05% maximum ice-point resistance driftCompliant with industrial vibration requirements
Protection contre la pénétrationIP65Connection head protected against dust and water intrusion
Certifications & Normes
Main StandardsCEI 60751, ANSI MC96.1Globally recognized temperature sensor standards
Marques de certificationCE, UL, ASCCompliant with international safety regulations
  1. Liste des accessoires & Mounting Parts
Part NameSpécificationFonctionScénario d'application
58C SheathCut-to-fit stainless steel sheathProtects sensor element and provides mechanical supportGeneral industrial process temperature measurement
Polypropylene Connection HeadInsulated typeProvides electrical connection and environmental protectionCorrosive environments & high insulation requirements
3-Wire Lead AssemblyPTFE insulated silver-plated copper wireTransmits temperature signal with 3-wire resistance compensationHigh-precision temperature measurement
Heat Shrink TubingInsulation protective sleeveSeals and protects lead-to-sensor jointOn-site installation for enhanced tightness
Installation ManualOperation guidelineDetailed installation procedures and precautionsField installation guidance
Temperature Calibration CertificateCalibration reportProvides sensor accuracy and calibration dataQuality traceability and ISO compliance
Mounting FittingsCompression fitting / Spring-loaded fittingFixes sensor inside thermowellAdapt to different mounting methods
  1. Concurrent & Cross-Brand Equivalent Models
MarqueModèle de remplacementSimilar FeaturesDifférences
ABBTSP400-100-B-3-0.25Pt100, Classe B, 3-fil, 0.25″ sheathDifferent head material, slightly lower price
Siemens7NG3211-0NN00Pt100, Classe B, 3-fil, stainless steel sheathSlightly slower response time (~15s)
YokogawaTR10-100B-3-025Pt100, Classe B, 3-fil, 0.25″ sheathSame temperature range, slightly higher calibration accuracy
Rosemount Internal Alternative7R8HCI-58-CPt100, Classe A, 3-fil, 316SST sheathClass A accuracy (±0.15°C @ 0°C), coût plus élevé
Rosemount Internal Alternative6R8HPI-58-CPt100, Classe B, 3-fil, Hastelloy sheathStronger corrosion resistance for harsh chemical environments
  1. Lignes directrices de sélection & Solutions de remplacement

5.1 Paramètres de sélection clés

ParamètrePoints clés de la sélectionRecommended Specification
Classe de précisionSelect according to measurement requirements; Class B for most industrial applicationsClasse B (±0.3°C); High-precision use Class A (±0.15°C)
Lead Configuration3-wire compensates lead resistance; 4-wire for highest accuracy3-fil (standard); 4-wire for laboratory & precision measurement
Sheath Material316SST for general environments; Hastelloy for heavy corrosion316SST (standard); Hastelloy for chemical industry
Connection Head MaterialPolypropylene for insulation; Aluminum for heat dissipation; Stainless steel for corrosion resistancePolypropylene for corrosive sites; Aluminum for high-temperature sites
Plage de température58C Series: -50°C~200°C; 68 Standard Series: -50°C~400°C58C for general industry; 68 standard sheath for high temperature
Sheath Length58C cut-to-fit design, no need for multiple inventory lengthsChoose standard length by insertion depth (12″/24″/36″/48″)

5.2 Recommandations de remplacement

Insufficient temperature range: Adopt 68 standard sheath model 6R8HCI-68, range extended to -50°C~400°C

Higher accuracy required: Select 7R8HCI-58-C (Class A accuracy, ±0.15°C @ 0°C)

Severe corrosion environment: Use 6R8HPI-58-C (Hastelloy) or 6R8HCI-58-T (Titanium) sheath

Faster response required: Choose 68Q fast-response series, response time reduced to 5 secondes

4-wire measurement needed: Select 6R8HCW-58-C to eliminate all lead resistance error

5.3 Application Precautions

  1. Trim the 58C sheath to required length with a standard pipe cutter before installation; reserve sufficient length for connection head assembly.
  2. Keep three lead wires equal in length for optimal resistance compensation in 3-wire connection.
  3. Avoid long-term operation above 392°F (200°C), exceeding the 58C sheath temperature limit.
  4. Ensure full contact between sensor tip and thermowell bottom during installation to minimize measurement error.
  5. Regularly inspect connection head sealing to prevent moisture ingress and accuracy drift.
  6. When matched with temperature transmitters (par exemple. Rosemount 3144S), correctly configure sensor type and parameters in the transmitter.
  7. Scénarios d'application typiques

Chemical process temperature measurement (corrosive environments; polypropylene head provides reliable insulation)

Nourriture & beverage industry (316 stainless steel complies with sanitary standards; cut-to-fit length adapts to various equipment)

Water treatment systems (chlorine corrosion resistance; 3-wire design ensures stable accuracy)

Systèmes CVC (matched temperature range and flexible installation)

Pharmaceutical industry (high-precision measurement compliant with GMP requirements)

Power industry (transformateur & generator winding temperature monitoring; 3-wire compensates cable resistance)

Huile & gas industry (pipeline and storage tank temperature measurement with corrosion-resistant sheath)

Précédent: