Code de commande: 3AUA0000058188
Statut du cycle de vie: Obsolète (Classic Maintenance Phase). Spare parts available, long lead-time for new stock; upgrade to ACS380 series is recommended.
- Type Code Decoding
ACS355-03E-07A3-4
| Champ | Description |
| ACS355 | ABB Machinery Conduire Série |
| 3 | Three‑phase AC power supply input |
| E | Built‑in 50Hz EMC RFI filter |
| 07A3 | Continuous rated output current 7.3 UN |
| 4 | Classe de tension: 380‑480 VAC three‑phase |
- Électricité de base & Spécifications mécaniques
| Article | Paramètre |
| Typical motor power rating | 3.0 kW (400 V three‑phase) |
| Rated output current I₂N | 7.3 A |
| Input power supply | Three‑phase 380‑480 V ±10%, 48‑63 Hz |
| Protection contre la pénétration | IP20 (cabinet‑mount installation) |
| Taille du cadre | R1 |
| Fréquence de sortie | 0‑600 Hz, vecteur / Contrôle V/F |
| Capacité de surcharge | 150% I₂N for 1 min per every 10 min; 180% I₂N peak for 2 s at start‑up |
| Fréquence de commutation | 4 kHz (défaut); adjustable from 4 kHz to 16 kHz |
| Built‑in functions | STO Safe Torque‑Off, integrated brake chopper, 8‑step sequence programming, FlashDrop fast parameter download |
| Dimensions hors tout (L×H×P) | 70 mm × 239 mm ×161 mm |
| Poids net | 1.8 kilos |
| Standard delivery scope | Control panel NOT included; panel must be ordered separately |
- Hardware Interface & Native I/O
- Entrées numériques: 6 DEPUIS; Sortie numérique: 1 FAIRE; Sortie relais:1 Relais
- Entrées analogiques:2 IA; Sortie analogique:1 AU
- Native RS-485 (Modbus RTU); supports plug-in fieldbus option modules
- Dual-channel hardware STO safety terminals (compliant with machinery safety standards)
- Power terminals: L1/L2/L3 power input; U/V/W motor output; BR+ BR-brake resistor terminals; PE protective earth
⚠️ Brake resistor NOT supplied as standard; brake resistor is an external optional accessory.
- Liste de colisage
✅ Items included in standard package:
- 1 × ACS355-03E-07A3-4 main unit
- I/O control terminal blocks, bornes de puissance, mounting screw kit
- Paper-format installation manual & quick-start guide
- Paper mounting cutout template
❌ NOT included in standard delivery; doit être commandé séparément:
Control panels: ACS-CP-A (Advanced panel J400), ACS-CP-C (Basic panel J404)
Fieldbus modules: FPBA-01 (Profibus-DP), FENA-01 (EtherNet/IP / PROFINET), FMBA-01 (Modbus RTU), etc..
I/O expansion module MREL-01; encoder interface module MTAC-01
External brake resistor, panel extension cable, FlashDrop tool
- Compatible Replacement & Solutions de mise à niveau
Original model is obsolete; two selection scenarios below:
Option 1: Upgrade to ABB ACS380-04-09A5-4 (3 kW,9.5 A)
Avantages: New-generation machinery drive, fonctions améliorées, hardware STO supported, parameter migration tool available
⚠️ Notice: Terminal layout and cabinet mounting cutouts are NOT fully compatible. Cabinet modification is required. I/O definitions differ. Direct plug-and-play replacement is impossible. Rewiring, parameter conversion and commissioning are mandatory.
Option 2: Spare-part stock of original ACS355-03E-07A3-4
Avantages: Montage identique, câblage et paramètres; direct drop-in replacement
Inconvénients: Limited stock, high unit price, long lead-time; classified as obsolete legacy spare-part stock.
- Scénarios d'application typiques
OEM machinery supporting: convoyeurs, machines d'emballage, équipement textile, woodworking machines, food-beverage processing equipment, small-size pumps & les fans, simple lifting mechanisms and general-purpose variable-speed applications.
- Notes de sélection & Application Boundary Conditions
- Température ambiante: Full-rating operation from 0 °C to +40 °C; derating required above 40 °C. Condensation, corrosive gas and heavy dust are prohibited. IP20 rating permits cabinet-only installation; direct field exposure is forbidden.
- This unit is factory-fitted with EMC filter. If input line reactor is added, ensure proper filter earthing.
- For heavy-duty cycles with frequent shock loading, select according to actual motor operating current instead of nominal power rating. If actual motor current exceeds 7.3 A, select the next higher drive frame size.
- Brake chopper is built-in; brake resistor must be externally fitted. Select brake resistor strictly per manual specifications. Never short-circuit BR terminals.
- For valid STO safety function in production operation, both STO channels shall be wired; single-channel short-circuit is prohibited.
- Important Maintenance Guidelines
Service life of R1-frame cooling fan: environ. 3 years; fan replacement is recommended upon expiry.
Retorque power terminals every 6 years.
Annual functional verification test for STO safety function is recommended.
Application Fields of ABB ACS355-03E-07A3-4 (3 kW) Fréquence Converter
This is a compact OEM-oriented vector drive with IP20 cabinet-mount rating. It comes with built-in STO Safe Torque-Off, integrated EMC filter and built-in brake chopper. It targets general-purpose variable-speed control for small-to-medium-power stand-alone OEM machinery, and is not intended for heavy-duty continuous high-power drive cycles.
- Conditionnement & Material-Handling Industry
Convoyeurs à bande, convoyeurs à rouleaux, chain conveyors, matériel de tri
Wrapping machines, case sealers, strapping machines, auxiliary palletizing mechanisms
Caractéristiques: Frequent start-stop cycles, smooth speed regulation; STO safety function supports machine safety protection.
- Woodworking Machinery
Wood cutting machines, sanders, multi-axis milling machines, saws
Material feed mechanisms for wood processing
Strengths: 0-600 Hz high-frequency output for high-speed spindles; on-board 8-step sequence programming reduces external PLC hardware requirement.
- Machines textiles
Small-scale spinning & weaving auxiliary feeders, machines à enrouler, sizing-machine auxiliary drives
Requirements: Couple stable à basse vitesse, tension-control capability; suitable for light-to-medium-duty winding tasks.
- Nourriture & Beverage Processing Equipment
Small mixing-tank drives, conveyor chains, filling-lines, labellers, sorting machines
Note: The drive must be installed inside electrical cabinets. Direct exposure to wash-down / humid environments is not allowed; proper cabinet environmental protection is required.
- Pompes & Ventilateurs (CVC & Traitement de l'eau)
Process circulation pumps, water-supply pumps, small centrifugal fans, ventilateurs d'extraction
Remarque: Pumps and fans belong to quadratic-torque loads. This drive is applicable; cependant, dedicated fan-pump drives are preferred for large-capacity energy-saving projects.
- Plastiques & Rubber Machinery Auxiliary Equipment
Feeder units, bandes transporteuses, small extruder auxiliaries, take-up & pay-off mechanisms
⚠️ NOT recommended for main injection-molding pump drives: Severe shock-loading exceeds the drive’s overload margin.
- Manutention des matériaux & Light Lifting Equipment
Light-duty elevators, auxiliary travelling mechanisms for small hoists, small lifting platforms
❗Critical boundary condition: For lifting applications, external brake resistor must be fitted and brake chopper enabled. Operation without brake resistor for lowering loads is strictly forbidden.
- General-Purpose Machine-Tools & Petit équipement de traitement
Small grinders, feed drives, small spindle drives.
❌ Non-applicable Conditions (Selection Pitfalls)
- Outdoor direct installation (IP20; montage en armoire uniquement).
- Direct exposure to corrosive atmosphere, heavy conductive dust, condensation or moisture.
- Heavy-shock high-duty-cycle main drives (par exemple. main injection-molding pumps, large winches).
- Field wall-mount installation requiring IP54 / IP65 high-protection rating.
Unit Application Matching Key Points
ACS355-03E-07A3-4 (3 kW /7.3 A) is intended for continuous rated load ≤3 kW motors. 150% overload for 1 min is specified for standard OEM machinery. For applications with frequent shock overload, select one power frame higher.
Full Detailed Parameters of ABB ACS355-03E-07A3-4
Code de commande: 3AUA0000058188; Frame size R1; Obsolète, spare-part maintenance supply only.
- Type-code Explanation
| Segment de code | Signification |
| ACS355 | ABB OEM Machinery Drive Series |
| 3 | Three‑phase AC power input |
| E | Built‑in C3‑class EMC RFI filter |
| 07A3 | Continuous output rated current 7.3 A |
| 4 | Voltage rating: 380‑480 V three‑phase |
- Main Electrical Ratings
| Article | Valeur |
| Typical asynchronous motor power | 3.0 kW @400 V three‑phase |
| Rated output current I₂N | 7.3 A |
| Tension d'entrée | Three‑phase 380‑480 VAC ±10% |
| Fréquence d'entrée | 48‑63 Hz |
| Tension de sortie | 0 ~ supply voltage (three‑phase) |
| Plage de fréquence de sortie | 0‑600 Hz (contrôle vectoriel sans capteur) |
| Capacité de surcharge | 150% I₂N for 1 min per every 10 min; 180% I₂N peak for 2 s on start‑up |
| Fréquence de commutation | Default 4 kHz; optional 4/8/12/16 kHz; derating required at high switching frequencies |
| Control modes | Scalar V/F, vecteur sans capteur; supports asynchronous & permanent‑magnet motors |
| Built‑in brake chopper ✅ | Standard; brake resistor is external |
| STO Safe Torque‑Off ✅ | Dual‑channel hardware; SIL3 / PL e (ISO 13849‑1) agréé |
| Drive efficiency | Approx.97% under rated load |
| DC bus voltage | 540 Vdc ±15% |
- I/O Terminal Specifications
Native I/O fitted; no mandatory expansion card required. Control panel is optional, not factory-supplied.
| Type de signal | Quantité & Spécification |
| Digital Input DI | 6 chaînes; PNP/NPN compatible; 12‑24 VDC; impedance 2.4 kΩ; pulse‑input capable:0‑16 kHz |
| Digital Output DO | 1 channel transistor output; max 30 VDC,100 mA, short‑circuit protected; max pulse‑output frequency 16 kHz |
| Relay Output REL | 1 canal; contact rating max 250 VAC 5 A;30 VDC 0.5 A; AC/DC compatible relay contact |
| Analog Input AI | 2 chaînes; configurable ‑10~+10 V voltage /‑20~20 mA current; AI1 impedance >312 kΩ (voltage mode),100 Ω (current mode) |
| Analog Output AO | 1 canal;0‑20 mA, max driving load 500 Ω |
| Auxiliary 24 V output | 24 VDC ±10%, max 200 mA; for DI & external sensor power supply |
| On‑board communication | Embedded EFB Modbus‑RTU (RS485); compatible with FPBA‑01, FENA‑01 and other fieldbus option modules |
| Safety terminals | X1C dual‑channel STO hardware safety terminals |
- Mécanique & Outline Data
| Article | R1 Frame ACS355‑03E‑07A3‑4 |
| Protection contre la pénétration | IP20 (cabinet‑internal installation); NEMA Open |
| Montage | DIN‑rail mounting / screw‑fixed panel mounting |
| Overall W×H×D | 70 mm ×239 mm ×161 mm (including mounting clips) |
| Poids net | 1.8 kilos |
| Package dimensions | 220 mm ×130 mm ×350 mm; single‑unit carton |
| Refroidissement | Integrated axial cooling fan; typical fan service life ~3 years |
- Conditions environnementales
| Article | Spécification |
| Température ambiante de fonctionnement | 0 … +40 °C full rating; derating above 40 °C; maximum permissible 50 °C (déclassé); icing and condensation prohibited |
| Température de stockage | ‑40 … +70 °C |
| Altitude | Full rating up to 1000 m above sea level; derate 1 % per additional 100 m above 1000 m; maximum operating altitude 2000 m |
| Degré de pollution | Operation class 2C2; direct exposure to conductive dust or corrosive gas is forbidden |
| Vibration | IEC 60068‑2‑6: 10‑57 Hz amplitude 0.25 mm; 57‑150 Hz 2 g |
| Choc | Transport:15 g 11 ms; fonctionnement:2 g |
- Certifications & Conformité
CE, UL/cUL, MRC(C-Tick), CAE(GOST-R), RoHS; compliant with Low-Voltage, EMC and Machinery Directives
Fonction de sécurité STO: SIL3 IEC 61508, PL e ISO 13849-1
Built-in E-filter meets C3 industrial-grade EMC requirements
- Built-in Function List
- 8-step on-board sequence programming for reduced external PLC hardware
- FlashDrop fast parameter copy tool support
- Motor thermal-protection, surintensité, surtension, sous-tension, earth-fault and output-short-circuit protection
- Stall protection, mechanical-brake control, Régulateur PID
- Speed-compensated stop, DC-braking, flux-braking
- Multiple parameter-set switching
- Complete fault-history logging, maintenance counters (fan runtime, power-on hours)
- Power Terminal Definition
| Terminal | Fonction |
| L1 L2 L3 | Three‑phase AC power input |
| U V W | Three‑phase motor output |
| BR+ BR‑ | Brake‑resistor connection (chopper built‑in; resistor external) |
| PE | Protective earth terminal |
⚠️ Do NOT short-circuit BR+ and BRterminals. Brake resistor must be selected strictly according to manual specifications.
- Option List (Not factory-supplied; commander séparément)
- Control panels: ACS-CP-A advanced panel, ACS-CP-C basic panel
- Fieldbus modules: FPBA-01 Profibus-DP; FENA-01 PROFINET/EtherNet-IP; FMBA-01 Modbus-RTU
- I/O expansion MREL-01; encoder interface MTAC-01
- External brake resistor, panel extension cable, FlashDrop tool
- Application Boundary Notes
- IP20 rating permits cabinet-mount installation only; not suitable for wash-down or humid field environments.
- Lifting-load applications require external brake resistor and activation of built-in brake chopper.
- Current derating is mandatory for ambient temperature 40 °C and altitude 1000 m.
- Legacy obsolete model; spare-part stock availability is limited. Upgrade to ACS380-04-09A5-4 requires cabinet modification and full rewiring.