Marque: Kraus & Naimer (Autriche, K&N, Blue Line Series)
Catégorie: CA10 Cam Switch
✅ Répartition du modèle
CA10: Base frame, Taille S0, Ith=20A, silver alloy rigid bridge contacts, bornes à vis, finger-safe terminals, compliant with IEC60947-3
WAA345: Function code → 9-pole 0-1 ON-OFF switch (9P ON-OFF), 5 contact layers, postes: 0 (DÉSACTIVÉ), 1 (SUR), switching angle 60°
FE: Montage & handle suffix
E: 2-hole panel mounting
F: Standard handle + nameplate, Protection IP40 (côté panneau)
✅ Core Electrical Ratings
Courant thermique conventionnel Ith: 20UN
Tension assignée d'isolement Ui: 690V CA/CC
AC-21A: 20UN; AC-15 (circuit de commande): 4A @ 440V
Tension de tenue aux chocs Uimp: 6kV
Température de fonctionnement: -25℃ ~ +60℃; Stockage: -40~+85℃
Contacts: Alliage d'argent, double-break contact structure, non-spring return (latching type)
Terminaux: Finger-protected screw terminals, compatible with PH1 cross screwdriver
✅ Mechanical & Construction Data
Contact layers: 5 modules de contacts (realizes 9 poteaux)
Postes: 2-position (0 / 1), no intermediate position
Montage: Standard K&N CA10 2-hole panel cutout
Durée de vie mécanique: ≥50,000 operations, maintenance-free cam mechanism
Certifications: CE, compliant with VDE0660-107
✅ Applications typiques
Synchronized start-stop of multiple circuits, master ON/OFF for multi-group control circuits in control cabinets, synchronous control of multiple solenoid valves / contacteurs, multi-channel power cut-off for test benches.
✅ Replacement & Spare Parts Info
- Remplacement de la même série: Same WAA345 function code, compatible base frames CA10, CA10B; CAD10 is spring return version, NOT direct replacement
- Alternative nationale: 9-pole 20A 2-position cam switch (contact sequence must match WAA345 timing diagram, timing is critical)
- Des pièces de rechange: Poignée, nameplate, shaft sleeve, terminal cover available separately
✅ Supporting Documentation
Standard drawing: K&N switch catalogue Schaltungsbuch, WAA345 sheet (Page 56), includes contact timing table
Numéro de commande: CA10.WAA345.EF; factory part number available via Catalogue 100
Note: WAA345 is a fixed timing standard function code, not custom cam profile. Fixed sequence: all 9 poles close simultaneously at position 1 and open at position 0. Suffix changes are required for spring return variants.
CA10.WAA345.EF = 9-pole, 2-position (0-DÉSACTIVÉ / 1-SUR, all contacts synchronized), latching non-auto-reset, panel-mounted, Ith 20A cam switch. Designed for one-key synchronous switching of multiple control circuits. NOT for motor reversing or voltage selection.
- Armoires de commande & Systèmes d'automatisation (Le plus courant)
- Master control for multi-solenoid valve banks: Synchronous power ON/OFF for solenoid valves in pneumatic & hydraulic cabinets; full isolation at 0-position for maintenance. Widely used in fixture stations, hydraulic workstations, valve island control cabinets.
- Master switch for multiple contactor / relay control circuits: Manual hardwired enable switch independent of PLC, to energize / de-energize auxiliary circuits locally.
- Multi-channel power supply for test benches & burn-in racks: Synchronously switch 9 low-voltage control channels for test fixtures, PCB aging racks, convenient batch start/stop and maintenance shutdown.
- Manuel / automatic circuit enable: Synchronous disconnection of multi-signal loops for safety compliance, cutting all auxiliary control signals during shutdown.
- Machines-outils, Special Machinery & Équipement d'emballage
- Machines d'emballage, auxiliary injection equipment, convoyeurs: Master ON/OFF for synchronized control circuits of air blow, clamping and positioning actuators.
- Welding jigs & special-purpose machines: Manual isolation switch for proximity sensors, clamping solenoid valve circuits.
- Central manual switching for auxiliary machine circuits (vannes de refroidissement, lubrication valves, air blow circuits).
- CVC, Traitement de l'eau & Équipement de protection de l'environnement
- Dust removal & waste gas treatment cabinets: Synchronous start-stop for pulse valves, solenoid valves and level switch circuits.
- Water treatment control cabinets: Manual master isolation for dosing valves and liquid level signal circuits.
Rappels: This is a control-circuit switch (Service AC-15), NOT suitable for direct switching of high-power main loads.
- Chemin de fer, Marin & Special Vehicle Electrical Control (K&N Traditional Strengths)
On-board electrical boxes, marine control panels: Synchronous isolation for indicator lights, feedback signals and small-power solenoid valves. Résistant aux vibrations, large plage de température (-25~+60℃).
Manual cut-off for locomotive auxiliary control circuits.
- Laboratoires, Power Supplies & Calibration Fixtures
- Multi-channel signal sources and load fixtures in labs: Synchronous switching of 9 signal channels.
- Manual master switch for auxiliary circuits, alarm loops and indicator lights inside power supply cabinets.
✅ Selection Notes & Éviter les pièges
- Fixed timing: All contacts open at 0 position and close together at 1 position. No staggered sequence; not applicable for sequential action, interlock or motor reversing.
- Positionnement du produit: Control circuit switch, NOT main circuit isolator. Main power circuits require dedicated isolating switches.
- Avantages clés: Résistance aux vibrations, excellent contact synchronization consistency, panel IP40 rating. Suitable for frequent manual operation where high multi-channel synchronism is required.
- Ne convient pas pour: Voltmeter selector, motor reversing, démarrage étoile-triangle (these require other W-series function codes).
Kraus & Naimer Common Model List
Règle de dénomination: Modèle de base + Code de fonction (WAA/A prefix) + Poignée / Mounting Suffix, Exemple: CA10.WAA345.EF
Series Definition: CA = Latching; CAD = Spring Return; C = High Current; L = Isolator / Commutateur de charge
- CA Latching Cam Switches (Série principale, CA10 Included)
| Modèle de base | Courant thermique conventionnel Ith | Taille | Description |
| CA4 | 10UN | S00, 30×30 panel | Mini low-current, circuits de commande, jusqu'à 9 contact layers |
| CA4-1 | 12UN | S00 | Upgraded CA4 |
| CB8 | 12UN | S0, 48×48 panel | Compact version, 48mm square panel mount |
| CA10 | 20UN | S0, 48×48 panel | Most universal model, the base of your part, standard for control cabinets |
| CA20 | 25UN | S0, 48×48 panel | Même empreinte, Courant nominal plus élevé |
| CA25 | 32UN | S1 | Service moyen, suitable for small motor main circuits |
| CA40 | 40UN | S1 | Load switching |
| CA50 | 50UN | S1 | Load switching |
| CA63 | 63UN | S1 | Heavy-duty cam switch |
| CA10B / CA20B / CA25B | 20/25/32UN | S1 | Extended housing for more contact layers |
- CAD Spring Return Cam Switches (Momentané / Impulsion, Not Direct Replacement for CA)
| Modèle de base | je | Description |
| CAD4-1 | 12UN | Mini momentary switch |
| CAD11 | 6UN | Contacts plaqués or, low-level signal & instrument circuits |
| CAD12 | 10UN | Silver contacts, momentary control signals |
| CAD20 | 25UN | High-current momentary version |
- C-Series High-Current Cam / Load Switches (Up to 315A)
C26, C32, C42, C43, C80, C125, C200, C315
- L-Series Load Isolators (Robuste, Main Circuit Isolation)
L350, L510, L630, L1000, L1200, L1600, L2000, L2400
- Frequently Used Standard Function Codes (WAA/A, for CA Bases)
Votre modèle: WAA345 = 9-pole, 0-1 MARCHE/ARRÊT, 60° synchronous switching
WAA100: 1-pôle 0-1
WAA101: 2-pôle 0-1
WAA102: 3-pôle 0-1
WAA103: 4-pôle 0-1
WAA341: 6-pôle 0-1
WAA345: 9-pôle 0-1 (This part)
WAA347: 10-pôle 0-1
A201: 3-phase motor forward-reverse
A202: Star-delta starter
A203: Dual power transfer (je-0-II)
WAA262: Multi-position selector with OFF position
WAA273: Multi-step selector switch
A476: Voltmeter selector switch
- Poignée & Mounting Suffixes (Last Letter)
E: 2-hole panel mounting (CA10.WAA345.EF)
F: Standard black handle + nameplate, IP40 panel side
G: Extended shaft handle
H: Key lock handle (padlockable)
K: Transparent protective cover
M.: Extended shaft
S: Rear wiring version
- Less Common Series
CG4 / CG8: Slim rear-wiring cam switches; CH, CHR: 25A compact control switches
✅ Complete Order Number Examples (For Inquiry & Quotation)
- CA10.WAA103.EF 4-pole 0-1
- CA10.WAA345.EF 9-pole 0-1 (Votre modèle cible)
- CA10.A201.EF 3-phase forward-reverse
- CA20.WAA102.EF 3-pole 25A ON/OFF
- CAD12.WAA101.EF 2-pole spring return
Kraus & Naimer Full Product Portfolio
Core competency: Modular cam rotary switches (Austrian manufacturer, established industrial manual switching brand). Classified below by category with current ranges and positioning.
- Cam Control Switches (Blue Line, CA10 belongs here, high inquiry volume for foreign trade)
- CA Series|Latching Cam Switches (Vaisseau amiral)
CA4 / CA4-1, CB8, CA10, CA10B, CA20, CA20B, CA25, CA40, CA50, CA63
je: 10A~63A; panel mounted, fixed detent positions. For ON-OFF, motor reversing, voltage selection, multi-circuit synchronous control, instrument selection.
- CAD Series|Spring Return Cam Switches (Momentané / Impulsion)
CAD4-1, CAD11 (gold contacts for weak signals), CAD12, CAD20
je: 6A~25A; auto-return after release, for momentary start/stop & pulse signals.
- CG / CH / CHR Compact Slim Cam Switches
CG4, CG8, CH, CHR; 10~25A, slim rear-wire housing, for cabinets with limited depth.
- D / DH / DK Precision Low-Signal Cam Switches
Ultra-low current: 20mA~25A; contacts plaqués or, for test equipment, semiconductors, calibration instruments and low-level signal switching.
- C Series|High-Current Cam Load Switches
C26, C32, C42, C43, C80, C125, C200, C315; direct load switching, small motor main circuits.
- X Series|Large-Capacity Tap / Group Transfer Cams
80A~630A; transformer tap switching, high-power multi-group synchronous transfer.
- Load Isolators / Main Switches, Maintenance Safety Switches (Main Circuit Isolation, Yellow-Red Handles)
- L Series Frame-Type Load Isolators
L350, L510, L630, L1000, L1200, L1600, L2000, L2400; up to 2400A, cabinet main isolation.
- KG / KH / KHR Motor Isolators (Machine-outil & VFD Special)
KG20, KG32, KG41, KG80, KG125, KG200, KG315; 20–315A; compatible with VFD EMC shielding solutions.
- Pre-assembled Enclosed Maintenance Switches (IP65/IP66)
KG switch pre-mounted in plastic / GRP fiberglass / stainless steel enclosure, verrouillage de porte, padlockable. For on-machine maintenance isolation; includes EV charger isolators and water heater dedicated isolators.
- G20 / G20S Blade DC Isolators
Heavy DC rating, for PV and energy storage.
- PV DC Isolators (New Energy Line)
KGD Series: PV dedicated DC isolators, IEC PV standard compliant, DC side disconnection, Résidentiel & commercial solar.
- Manual Transfer & Bypass Switches
Manual Transfer Switch (MTS): je-0-II dual source mains/generator switching
UPS bypass switches, manual generator paralleling switches
- KA Modular Custom Cam Platform
KA is a free-configurable building-block system, different from CA fixed function codes. Customizable contact timing, positions and switching angles for non-standard machinery, special vehicles and railway rolling stock.
- Boutons poussoirs & Indicating Lights (22.5mm Command Devices)
Flat pushbuttons, illuminated pushbuttons, mushroom emergency stops, double-layer pushbuttons, key-operated pushbuttons, selector knobs
Signal lamps, buzzers, potentiometer units; blocs de contacts auxiliaires, LED modules, nameplates & accessoires
Protection IP66, food-grade corrosion-resistant versions available
- Contacteurs & Motor Starter Units (Composants de support)
Contacteurs: 16A–115A; relais de surcharge thermique, direct-on-line starters. For panel assembly paired with K&N switches.
- Safety Locking & Accessoires de verrouillage
Key interlock systems, trapped-key safety interlocks (mechanical interlock for forced safety isolation)
Padlock kits, cabinet door interlock mechanisms, blocs de contacts auxiliaires, extended shafts, key handles, nameplates
- Enclosure Accessories
FIBOX partner enclosures, GRP fiberglass housings, armoires en acier inoxydable, sealing kits, cable glands
- Speciality Switches for Target Industries
Railway rolling stock control cams
Marine approved switches
Stainless steel corrosion-resistant variants (traitement de l'eau, nourriture & boisson)
Foot switches, palm-operated switches
✅ Quick Selection Cheat Sheet (For Product Page Sourcing)
Synchronous multi-control-circuit ON/OFF → CA (CA10.WAA345.EF)
Momentary pulse signals → CAD
Motor main circuit isolation & maintenance switches → KG, enclosed maintenance switches
High-current main cabinet isolation → L Series
Solar PV DC side → KGD
Non-standard custom timing → KA Custom Platform
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur






















NH42-63-318x560.png)