Adaptateur Allen-Bradley 1747-AENTR - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Adaptateur Allen-Bradley 1747-AENTR - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

API/

Adaptateur Allen-Bradley 1747-AENTR

Positionnement: SLC500 rack EtherNet/IP remote I/O adapter (NOT an SLC processor). It converts the existing 1746 SLC I/O rack into an EtherNet/IP slave, which is scanned and controlled by Logix controllers (CompactLogix, ContrôleLogix). It is the most commonly used gateway module for phased upgrades of legacy SLC systems. ✅ Basic Specifications Series: A/B series; Dernier ...

  • Détails du produit

Positionnement: SLC500 rack EtherNet/IP remote I/O adapter (NOT an SLC processor). It converts the existing 1746 SLC I/O rack into an EtherNet/IP slave, which is scanned and controlled by Logix contrôleurs (CompactLogix, ContrôleLogix). It is the most commonly used gateway module for phased upgrades of legacy SLC systems.

✅ Spécifications de base

Série: A/B series; Latest firmware V2.003

Port: 1 × RJ45, 10/100 Négociation automatique Mbps, EtherNet/IP (CIP)

Mandatory mounting requirement: Must be installed in Slot 0 of the SLC chassis, replacing the original SLC processor position

Fond de panier: 1746 SLC backplane with SLC backplane master function

Connection resources: Max.. 96 Classe 1 (real-time I/O) connections, maximum. 8 Classe 3 (explicit message) connections

Network topology: Supports star, linéaire, DLR (Device Level Ring)

Configuration IP: Commutateur DIP / BOOTP / DHCP; DIP switch set to `888` = factory reset

Alimentation: Powered by the SLC chassis power supply, consommation d'énergie environ. 5 W

Exigence logicielle: Studio 5000 / RSLogix5000 V20 or newer; matching EDS/AOP files required

Manuals: User manual 1747-UM076; Installation manual 1747-IN521

✅ Applications typiques

  1. Retrofit of legacy SLC systems: Retain all 1746 I/O modules and field wiring. Only replace the Slot 0 processor with 1747-AENTR and upgrade the main controller to CompactLogix/ControlLogix for phased migration without full shutdown.
  2. Replacement of legacy remote I/O adapters: Substitute 1747-ASB (RIO), 1747-ACN15/ACNR15 (ControlNet).
  3. Operate as an EtherNet/IP slave for CIP explicit read/write access by HMI or SCADA hosts.

✅ Lifecycle & Migration Alternatives

Statut: EOL, end-of-production date 2027-02-15. It is an engineering replacement part with no direct pin-compatible drop-in replacement.

Long-term migration options:

Option A: Migrate the complete chassis to Compact 5000 E/S (5069 série)

Option B: Keep existing field wiring and adopt 1746-to-5069 adapter base

Spare parts are only available as new-old-stock or used units. For second-hand units, verify firmware, Port Ethernet, backplane connector and indicator lamps.

✅ Indicator Definitions

D'ACCORD: Module status

LINK: Ethernet link status

E/S: SLC backplane I/O status

COMM: CIP connection status

FORCE: Force signal active

✅ Key Common Faults

  1. CIP 0x0010 fault: The controller holds an active connection lock on the module. Inhibit the module in Studio5000 before modifying IP settings, then remove inhibit after configuration.
  2. Flashing COMM red & RPI timeout: Do not configure a short RPI for SLC analog modules (1746-NI4, OAP12 etc.). Recommended RPI: 50~100 ms, maximum 320 MS; short RPI causes frequent packet loss.
  3. Invalid DIP IP setting (000 or value >254 and not 888): Module automatically uses BOOTP/DHCP for IP assignment.
  4. Not all legacy 1746 modules are supported by AENTR; verify the support list in manual before configuration.

✅ Confusing Model Distinction

1794-AENTR: Flex I/O (1794) EtherNet/IP adapter for Flex chassis, NOT compatible with SLC 1746 chassis

1747-L5xx: Native SLC processors with backplane master capability, functionally different from AENTR

1747-AENTR Common Faults, Symptômes, Causes profondes & Remèdes

Condition préalable: Module must be installed in SLC chassis Slot 0, occupying the processor slot; powered by SLC backplane; mainstream firmware V2.003; Studio5000 minimum V20; not all legacy 1746 modules are supported.

  1. CIP 0x0010 (Hex 0010) Faute (Le plus fréquent)

Symptôme: Error when modifying IP or disabling BOOTP/DHCP via BOOTP/RSLinx; prompt “Set Attribute Single failed”; configuration cannot be written from controller side; IP reverts to DHCP after power cycle.

Cause première: Une classe 1 I/O connection has been established by the controller. The module is connection-locked and rejects configuration writes from external tools.

Remedy Steps

  1. Go online in Studio5000, right-click 1747-AENTR → Properties → Connection → ✅ Check Inhibit Module, apply, and terminate the I/O connection.
  2. Modify IP and disable BOOTP/DHCP via BOOTP/RSLinx/web page to save static IP.
  3. Remove inhibit after configuration is completed to restore communication.

Alternative: Put controller in Program mode or disconnect Ethernet cable; cable pull during production is not recommended.

  1. COMM Red Flashing, I/O Timeout, RPI Timeout, Intermittent Slave I/O Faults

Symptôme: OK steady green, LINK steady green, COMM red flashing; slave modules (especially 1746-NI4, OAP12 analog modules) drop out periodically; RPI timeout logged.

Cause première

RPI configured too low for analog modules (défaut 20 MS; SLC backplane bandwidth is limited)

Mauvais contact du fond de panier, insufficient chassis power rating

Incompatible legacy 1746 module present

High backplane bus load or aged module hardware

Remède

  1. Set analog module RPI to 50~100 ms, maximum 320 MS; adjust the AENTR adapter RPI accordingly.
  2. Éteindre, reseat all 1746 modules and clean gold fingers; verify SLC power supply capacity.
  3. Cross-check against supported module list and remove incompatible modules.
  4. Check backplane slot timeout counters via embedded web diagnostics to locate faulty slot.
  5. OK Steady Red, Power-On Self-Test Failure, No Communication

Symptôme: OK red solid after power-up, LINK off, module cannot be browsed in RSLinx.

Cause première

Hardware failure or corrupted firmware

Factory reset via DIP 888 failed

Poor backplane power supply, damaged Slot 0 backplane contacts

Module installed in wrong slot (not Slot 0)

Remède

  1. Confirm installation in Slot 0 and test with a known-good SLC chassis power supply.
  2. Set DIP switch to 888, power cycle for factory reset; reassign IP via BOOTP.
  3. If OK remains red after reset: module hardware failure, remplacer l'unité.
  4. LINK Off / Clignotant, No Network Connectivity, RSLinx Cannot Find Module

Symptôme: OK normal, LINK off or amber flashing, ping fails.

Cause première: Câble Ethernet endommagé, defective switch port, speed mismatch, IP subnet mismatch, Conflit d'adresse IP.

Remède

  1. Replace with qualified industrial Ethernet cable and change switch port; ensure switch port is 10/100M auto-negotiation (do not force gigabit).
  2. Set DIP to 000, power up to obtain IP via BOOTP; ensure PC and module are on the same subnet.
  3. Check network for IP conflict.
  4. IP Reverts After Power Cycle, Static IP Will Not Save

Symptôme: Static IP assigned and BOOTP disabled in BOOTP tool, but IP reverts to DHCP after power cycle.

Cause première: Only IP address changed, BOOTP/DHCP client toggle not disabled; 0x0010 connection lock prevents the disable command from being written to Flash memory.

Remède: Inhibit module first, then set BOOTP/DHCP to Manually Configure on module configuration page, confirm successful write, then remove inhibit.

  1. AENTR Disconnect After Program Download (Known Bug for CompactLogix 5370 L3)

Symptôme: Plus que 5 I/O modules in chassis; AENTR loses communication after second program download, controller USB/Ethernet port also unresponsive.

Cause première: Rockwell known firmware defect.

Temporary workaround: Disconnect AENTR Ethernet cable before download; reconnect after controller enters Run mode. Long-term fix: Upgrade controller firmware or replace controller model.

  1. Electronic Key Fault (Hex 0103)

Symptôme: Module fault, type mismatch / keying failure alarm.

Cause première: AOP revision or firmware revision in project does not match physical hardware; or configured slot I/O model differs from actual installed module.

Remède

  1. Read actual firmware revision from module and match firmware version in Studio5000 module definition.
  2. Verify the part number of every 1746 module in chassis; avoid mixed use with compatible/disabled keying mode.
  3. Reimport the matching AOP file.
  4. FORCE Lamp Solid On

Symptôme: FORCE indicator illuminated.

Cause première: One or more I/O tags are forced.

Remède: Clear all force tags in the force window of Studio5000.

  1. Single Slave I/O Module Fault, Adapter Communication Normal

Symptôme: AENTR communicates normally, only one slot module faults while other I/O runs fine.

Cause première: Failed 1746 module, poor base contact, unsupported module model, local module power fault.

Remède: Swap the suspect module to another slot for cross-testing; verify module health; check support list.

Indicator Quick Reference

D'ACCORD: Module status|Green = Normal; Red = Fault / POST fail; Amber = Initializing

LINK: Ethernet link|Solid = Link up; Blinking = Traffic present; Off = No link

COMM: CIP I/O connection|Green = I/O connection healthy; Red blink = Connection fault / temps mort

E/S: SLC backplane I/O status|Red = Backplane / slave module fault

FORCE: Force active

Standard On-Site Troubleshooting Sequence

  1. Confirm mounting position: Fente 0 seulement
  2. Read indicator status to isolate fault domain: network, adapter hardware or backplane I/O
  3. Browse via RSLinx to confirm module accessibility and read firmware
  4. If browsable: Inhibit module prior to IP/configuration edit; inspect RPI settings
  5. If not browsable: Vérifier le câble, changer, alimentation, factory reset via DIP
  6. Single backplane slot fault: Isolate by module swapping
  7. Firmware corruption: Re-flash firmware with ControlFLASH Plus

Liste de contrôle d’inspection des unités d’occasion

  1. Verify factory reset via DIP 888 works reliably
  2. BOOTP assignment and embedded web page accessible
  3. Stable steady green OK lamp after power-up, no fault
  4. Chassis bench test: Monter 1746 DI module, build I/O tree in Studio5000, run 30 minutes without RPI timeout
  5. Inspect Ethernet port and backplane gold fingers for corrosion or bad solder

Allen-Bradley SLC500 Full Model List (1747 Controller Family + 1746 Chassis & I/O Family, All EOL Discontinued)

Note: SLC500 consists of two main families: 1747 (Processors, Communication Adapters, Scanners) et 1746 (Chassis, Power Supplies, E/S numériques, E/S analogiques, Specialty I/O). The whole platform is discontinued; spare parts are traded as new-old-stock or used hardware.

  1. 1747 Processors (Processeur)|SLC5/01 ~ SLC5/05
Numéro de pièceFamilleDescription
1747-L511SLC5/011K program memory, DH485, unité de base
1747-L514SLC5/014K program memory, DH485
1747-L524SLC5/024K program memory, DH485, remote I/O capable
1747-L531SLC5/038K, DH485+DH+
1747-L532SLC5/0316K, DH485+DH+
1747-L533SLC5/0332K, DH485+DH+
1747-L541SLC5/0416K, DH485+DH++RS232
1747-L542SLC5/0432K, DH485+DH++RS232
1747-L543SLC5/0464K, DH485+DH++RS232
1747-L551SLC5/0516K, integrated EtherNet/IP+DH485
1747-L552SLC5/0532K, integrated EtherNet/IP+DH485
1747-L553SLC5/0564K, integrated EtherNet/IP+DH485 (Top-tier SLC processor)
  1. 1747 Communication Adapters / Scanners (1747-AENTR Listed Here)
Numéro de pièceDescription
1747-AENTREtherNet/IP adapter for SLC Slot0, converts 1746 I/O to EtherNet/IP slave (Key model)
1747-ASBRIO remote I/O adapter (RIO slave)
1747-SNRIO remote I/O scanner (RIO master)
1747-ACN15ControlNet scanner
1747-ACNR15ControlNet redundant adapter
1747-DSNDeviceNet scanner
1747-KEDH485/RS232 protocol converter
1747-CP3Programming cable adapter
1747-C11DH485 cable
1747-DU501Data storage module
  1. 1746 Chassis
Numéro de pièceSlot Count
1746-A44-slot chassis
1746-A77-slot chassis
1746-A1010-slot chassis
1746-A1313-slot chassis
  1. 1746 Chassis Power Supplies
Numéro de pièceNotation
1746-P1120/240Entrée V CA
1746-P2120/240V et
1746-P324Entrée V CC
1746-P4120/240V et, haute puissance
1746-P524V DC high power
1746-P624À DC
1746-P7120/240V et
  1. 1746 Entrée numérique DI
Numéro de pièceNotation
1746-IA4120V AC 4-point input
1746-IA8120V AC 8-point input
1746-IA16120V AC 16-point input
1746-IM4240V AC 4-point input
1746-IM8240V AC 8-point input
1746-IM16240V AC 16-point input
1746-IB824V DC sink 8-point
1746-IB1624V DC sink 16-point
1746-IB3224V DC sink 32-point
1746-IV824V DC source 8-point
1746-IV1624V DC source 16-point
1746-IV3224V DC source 32-point
1746-ITB1624V DC high-speed sink 16-point
1746-ITV1624V DC high-speed source 16-point
1746-IC1648V DC 16-point
1746-IH16125V DC 16-point
1746-IG165V TTL 16-point
1746-IN16Universal AC/DC 16-point
  1. 1746 Sortie numérique DO
Numéro de pièceNotation
1746-OA8120/240V AC 8-point output
1746-OA16120/240V AC 16-point output
1746-OAP12120/240V AC high-current 12-point
1746-OB824V DC source 8-point
1746-OB1624V DC source 16-point
1746-OB3224V DC source 32-point
1746-OB6EIIsolated DC output 6-point
1746-OW4Relay 4-point
1746-OW8Relay 8-point
1746-OW16Relay 16-point
1746-OX8Isolated relay 8-point
  1. 1746 Combination I/O (DI+FAIRE)
Numéro de pièceNotation
1746-IO42DI+2DO 120V AC + relais
1746-IO84DI+4DO
1746-IO126DI+6DO AC/relay
1746-IO12DCDC combination I/O
  1. 1746 Analog I/O AI/AO
Numéro de pièceDescription
1746-NI44-channel analog input 4-20mA/0-10V
1746-NI88-entrée analogique de canal
1746-NR4RTD 4-channel
1746-NT4Thermocouple 4-channel
1746-NT8Thermocouple 8-channel
1746-NO4I4-channel isolated analog output
1746-NO8V8-channel voltage output
1746-NO4V4-channel voltage output
1746-NIO4I2AI+2AO isolated analog combo
1746-NIO4V2AI+2AO voltage analog combo
  1. 1746 Specialty Modules (Compteur à grande vitesse, Positionnement, BASIC etc.)
Numéro de pièceDescription
1746-HSCEHigh-speed counter / encodeur
1746-HSCE2Upgraded high-speed counter
1746-HSTP1Stepper positioning module
1746-BASBASIC co-processor module
1746-SDNDeviceNet scanner (chassis mount)
1746-HCAHigh-speed counter accessory
  1. Accessoires

1746-C7, 1746-RT25, 1747-BA (Batterie au lithium), borniers, covers, expansion cables etc.

Supplementary Notes for Retrofit Projects

  1. 1747-AENTR Compatibility Limit: Not all 1746 modules are supported. Early specialty modules (legacy HSCE, BAS) may not be recognized; analog module RPI must not be too short.
  2. Easy Confusion: 1794-AENTR is Flex I/O adapter, not part of SLC500 (1746) family.
  3. Migration Path: Preferred upgrade route for full SLC replacement: CompactLogix + 5069 Compact5000 I/O.

Précédent:

Suivant:

Laisser une réponse

Laisser un message