Beckhoff ES2008 Output Terminal Module - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Beckhoff ES2008 Output Terminal Module - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

Beckhoff ES2008 Output Terminal Module

ES2008: EtherCAT 8-channel digital output terminal module, 24 VCC / 0.5 A per channel, version with pluggable split wiring base. Its electrical performance is identical to EL2008 of beckhoff, differing only in wiring structure. Differences Between ES / IL / ED Versions Model Wiring Type Application Scenarios EL2008 Integrated screw terminals, non-pluggable Standard fixed control ...

  • Détails du produit

ES2008: EtherCAT 8-channel digital output terminal module, 24 VCC / 0.5 A per channel, version with pluggable split wiring base. Its electrical performance is identical to EL2008 of beckhoff, differing only in wiring structure.

Differences Between ES / IL / ED Versions

ModèleType de câblageScénarios d'application
EL2008Integrated screw terminals, non-pluggableStandard fixed control cabinets with infrequent IO replacement
ES2008Split pluggable wiring baseFast module replacement for equipment after-sales service; no cable re-crimping required
ED2008Integrated spring push-in terminalsCâblage rapide, connexion sans outil
  1. Core Electrical Specifications
  2. Channel Specifications

Output channels: 8-channel single-ended NPN digital outputs

Tension nominale: 24 VCC (allowable fluctuation range: -15% ~ +20%)

Maximum current per channel: 0.5 UN, equipped with short-circuit protection and reverse polarity protection

Maximum total carrying capacity of power contacts: 10 UN

Permitted loads: Charges résistives, inductive solenoid valve loads, indicator light loads

Breaking energy: < 150 mJ per channel (compatible with small solenoid valves)

  1. Timing & Isolement

Turn-on time Ton ≈ 60 µs, Turn-off time Toff ≈ 300 µs

Electrical isolation between E-bus and field loads: 500 ACC

Process image occupation: 8 output bits

  1. Consommation d'énergie

E-bus supply consumption: Typique 90 mA

Field supply: 15 mA quiescent current + load current of each channel

  1. Mécanique & Spécifications environnementales

Dimensions: 12 MM (W) × 100 MM (H) × 68 MM (D)

Poids: Environ. 55 g

Montage: Standard 35 mm rail DIN

Classe de protection: IP20 (cabinet installation only)

Température de fonctionnement: -25 ℃ ~ +60 ℃ (montage horizontal); maximum. +45 ℃ for vertical mounting

Température de stockage: -40 ℃ ~ +85 ℃

Humidité: 95% RH, sans condensation

Certifications: CE, UKCA, cULus, CAE

Vibration / Résistance aux chocs: Conforme à la norme EN 60068-2-6 / DANS 60068-2-27

  1. Unique Advantages of ES2008 Pluggable Structure
  2. The wiring base remains permanently on the cable side inside the control cabinet; the module body can be plugged and replaced separately.
  3. No terminal cable disassembly required for equipment fault maintenance, greatly reducing downtime.
  4. The base supports standard wire gauges: 0.08~2.5 mm² solid / stranded wires; 0.14~1.5 mm² for wires with cable lugs.
  5. Standard wire stripping length: 8~10 mm, screw-tightened terminals.
  6. Wiring Definition (Fully Compatible with EL2008)

Common power terminals: 24V+, 0V (unified power supply on module side)

Channel outputs: Ch1~Ch8 (Sortie NPN, sorties 0 V when switched on)

Independent status LED for each channel; green light = output activated

  1. Scénarios d'application typiques
  2. Control of machine tool solenoid valves and cylinder directional valves
  3. Assembly line indicator lights and alarm buzzers
  4. Drive of small relay coils
  5. Output for conveying and material stop cylinders on packaging equipment
  6. Production lines requiring frequent on-site IO module replacement (ES version is preferred)
  7. Remplacement & Description de la compatibilité
  8. Direct interchangeable: ES2008 ↔ EL2008 (fully compatible in programming and EtherCAT configuration, only base structure differs)
  9. High-density alternative: EL4008 (16 FAIRE, saves DIN rail space)
  10. High-current alternative: EL2024 (4 FAIRE, 2 A per channel for large solenoid valve driving)
  11. Diagnostic-equipped version: EL2014 (4 FAIRE, with short-circuit channel fault diagnosis)
  12. Résumé de la sélection

Choose ES2008: Frequent equipment after-sales maintenance and fast IO module replacement needed

Choose EL2008: Fixed control cabinets with rare cable disassembly, moindre coût

Choose ED2008: Fast on-site wiring without screwdrivers

Protection Class of Beckhoff ES2008

IP20 (Standard parameter from Beckhoff official manual)

Supplementary Explanation

  1. EL2008, ED2008 and ES2008 in the same series feature identical housing protection structure, all rated IP20.
  2. Definition of IP20 rating:

Premier chiffre 2: Prevents ingress of solid foreign objects ≥12.5 mm such as fingers

Second digit 0: No water or dust protection; must not be directly exposed to mist, dust or liquid

  1. Application requirement: Must be installed inside a sealed electrical control cabinet, not for bare installation outdoors, in humid or dusty environments.
  2. If high-protection field IO is required, select EP series EtherCAT junction boxes (IP65 / IP67).

Full List of Beckhoff ES2xxx Digital Output Modules with Pluggable Base (Matching EL2xxx specifications; ES = split pluggable wiring base)

  1. Standard 0.5 A NPN Output (General Solenoid / Voyant lumineux, IP20)
ES ModelCorresponding EL ModelCanauxSpecification Description
ES2004EL20044 FAIRE24 VCC, 0.5 A per channel, no per-channel diagnosis
ES2008EL20088 FAIRE24 VCC, 0.5 A per channel, general-purpose standard model (the model you enquired about)
ES2014EL20144 FAIRE24 VCC / 0.5 UN, per-channel short-circuit / overcurrent diagnosis
ES2024EL20244 FAIRE24 VCC, courant élevé 2 A per channel for large solenoid valve driving
ES2032EL20322 FAIRE24 VCC / 2 A with channel diagnosis
ES2034EL20344 FAIRE24 VCC / 2 A with channel diagnosis
ES2084EL20844 FAIREHigh-density 16 mm largeur, 8-channel capacity condensed into 4 bornes
ES2088EL20888 FAIREUltra-slim 16 boîtier mm, saves DIN rail space
ES2807EL280716 FAIREHigh-density 16-channel 0.5 A outputs
ES2809EL280932 FAIREHigh-density 32-channel 0.5 A outputs
  1. ES Series with Special Voltage Outputs
ES ModelCorresponding EL ModelCanauxSpecification Description
ES2124EL21244 FAIRE5 VDC CMOS level output, matching industrial control board signals
  1. Naming Rule Distinction for ES Series (3 wiring versions with identical electrical parameters)
  2. ELxxxx: Integrated screw terminals, non-pluggable, standard low-cost version
  3. ESxxxx: Split pluggable screw base (series that ES2008 belongs to), no cable disassembly during maintenance
  4. EDxxxx: Integrated spring push-in terminals, câblage rapide sans outil
  5. EFxxxx: Split pluggable spring push-in base
  6. General Common Parameters of ES2xxx Series
  7. Classe de protection: All rated IP20, cabinet-use only
  8. Bus isolation: 500 VAC isolation between E-bus and field loads
  9. Alimentation: 24 VDC field power, NPN low-side output (sorties 0 V when activated)
  10. Fonctions de protection: Protection contre les courts-circuits, reverse polarity protection, with channel status LEDs
  11. Mechanical width: Standard 24 MM; ultra-slim 16 mm for ES2084 / ES2088
  12. Special DO Modules Without ES Versions in the Same Series (No Split Base Variants, IL / ED Only)

EL2042: Sortie relais (no ES version available)

EL2062: 230 VAC triac output (no ES version available)

ELX2008: Explosion-proof intrinsically safe output (no ES version available)

TwinSAFE safety outputs EL29xx: No split-base ES variants available

Notes de traduction

  1. Industry standard terms unified:

DO = Digital Output, Rail DIN, NPN low-side output, protection contre les courts-circuits, intrinsèquement sûr, triac, quiescent current

  1. Beckhoff official terminology retained: E-bus, EtherCAT, TwinSAFE
  2. Unit symbols follow international industrial standards (VCC, UN, µs, mJ, MM, ℃, mm²)
  3. Tables maintain original structure for engineering document direct use

Précédent:

Suivant:

Laisser une réponse

Laisser un message