Carlo Gavazzi WM12-96.AV5.3.3.X Multi-functional Power Meter

Carlo Gavazzi WM12-96.AV5.3.3.X is a 96×96mm panel-mounted three-phase multi-functional power meter. It adopts TRMS True RMS measurement technology, designed for 400V three-phase four-wire systems, with 230V AC power supply and no RS485 communication function. Its core advantages include high-precision measurement (Voltage/Current ±0.5% FS), multi-parameter display (12 measuring pages), wide measuring range (0.03-6A current) et haut ...

  • Détails du produit

Carlo Gavazzi WM12-96.AV5.3.3.X is a 96×96mm panel-mounted three-phase multi-functional power meter. It adopts TRMS True RMS measurement technology, designed for 400V three-phase four-wire systems, with 230V AC power supply and no RS485 communication function. Its core advantages include high-precision measurement (Voltage/Current ±0.5% FS), multi-parameter display (12 measuring pages), wide measuring range (0.03-6A current) and high protection degree (IP65 front panel). It is ideally applied in industrial automation, bâtiments commerciaux, data centers and OEM equipment. It can monitor power parameters in real time, help users optimize energy consumption and reduce operating costs.

  1. Définition du code modèle
SectionCodeDescription
Code de sérieWM12-96Carlo Gavazzi WM12 series 96×96mm panel-mounted multi-functional power meter
Range CodeAV5380/660V line-line, 5(6)A AC current input, suitable for 400V power system
Type de système3Système triphasé à quatre fils (configurable as three-phase three-wire, ARON, two-phase or single-phase)
Power Supply Type3230V AC ±15% +10%, 50-60Hz (Code A=24VAC, B=48VAC, C=115VAC, D=18-60VDC)
Function OptionXWithout RS485 output (S=With RS485 MODBUS/JBUS output)

Numéro de commande: WM12-96AV533X (Standard single package)

  1. Main Technical Specifications
CatégorieArticleValeurRemark
Basic InfoType de produitThree-phase multi-functional power meterBuilt-in programming keypad, TRMS true RMS measurement
Afficher14mm LED, 3×3 digitsRefresh rate: 700MS, 12 measuring pages
Type de montagePanel mountingDimension:96×96×63mm, Cut-out size:61.4×61.4mm
Classe de protectionFront IP65, Terminal IP20Comply with NEMA4x/12 standard
Electrical SpecsPlage de tension380/660V L-L, 185-460V L-NAV5 range, Précision: ±0.5% FS +1 digit
Plage actuelle5(6)Et clim, Phase current:0.03-6UN, Neutral current:0.09-6UNPrécision: ±(0.5% FS +1 digit) within 0.25-6A
Tension d'alimentation230V AC ±15% +10%, 50-60HzConsommation d'énergie:4.5Virginie
Paramètres mesurésTension, Actuel, Pouvoir, Facteur de puissance, Fréquence, Demande, Maximum valueSystem-wide & phase-separated measurement supported
PrécisionActive/Apparent Power±(1% FS +1 digit) (0.25-6UN)±(1% FS +5 digits) at 0.03-0.25A
Puissance réactive±(2% FS +1 digit) (0.25-6UN)±(2% FS +5 digits) at 0.03-0.25A
Fréquence±0.1% Hz (48-62Hz)Sampling:1400 samples/s@50Hz, 1700 samples/s@60Hz
Neutral Current±(1.5% FS +1 digit) (0.25-6UN)±7 digits at 0.09-0.25A
CommunicationInterfaceAucun (X version)S version: RS485, MODBUS/JBUS, 9600 débit en bauds
Communication DistanceMax 1200m for S version, 2/4-wire connection
Ambient SpecsTempérature de fonctionnement-5℃ ~ +50℃RH<90% non-condensing @40℃
Température de stockage-30℃ ~ +60℃RH<90% non-condensing @40℃
Classe d'isolationOvervoltage Category III (CEI 60664)Withstand 4000VAC between input and power supply for 1 minute
Physical SpecsMatériau du boîtierSelf-extinguishing ABS (UL 94 V-0)Poids: approx.400g (with package)
TerminauxType de visMax cable cross-section:2.5mm², 5(6)A current input
AttestationCEOuiComply with EN50084-1 Class A, EN61000-6-2 Class A
ULOuicULus certified, meet North American safety standards
EMC StandardComply with EN61000-4-51.2/50μs surge immunity
  1. Full Model List of WM12-96 Series
Range CodeType de systèmeAlimentationFonctionModèleNuméro de commande.
AV53(3-phase 4 fils)UN(24ACC)X(No RS485)WM12-96.AV5.3.A.XWM12-96AV53AX
S(RS485)WM12-96.AV5.3.A.SWM12-96AV53AS
B(48ACC)XWM12-96.AV5.3.B.XWM12-96AV53BX
SWM12-96.AV5.3.B.SWM12-96AV53BS
C(115ACC)XWM12-96.AV5.3.C.XWM12-96AV53CX
SWM12-96.AV5.3.C.SWM12-96AV53CS
3(230ACC)XWM12-96.AV5.3.3.XWM12-96AV533X
SWM12-96.AV5.3.3.SWM12-96AV533S
D(18-60VCC)XWM12-96.AV5.3.D.XWM12-96AV53DX
SWM12-96.AV5.3.D.SWM12-96AV53DS
AV63(3-phase 4 fils)3(230ACC)XWM12-96.AV6.3.3.XWM12-96AV633X
SWM12-96.AV6.3.3.SWM12-96AV633S

Modèles spéciaux: WM12-DIN (DIN rail type), WM14-96 (with 15th harmonic analysis)

  1. Remplacement & Modèles équivalents

4.1 Internal Carlo Gavazzi Replacement

Old ModelNew ModelReplacement Description
WM1-96WM12-96Upgraded true RMS measurement, higher accuracy, added demand & max value display
WM12-96.AV5.3.D.SWM12-96.AV5.3.D.SEntièrement compatible, optimized firmware, support latest MODBUS protocol

4.2 Cross-brand Equivalent

MarqueModèle équivalentAvantages
SchneiderPM2000More cost-effective, higher front IP65 protection
Siemens7KM2112Support more system types including ARON & two-phase, flexible programming
ABBE20012 display pages for clearer reading, standard 96×96mm mounting size
  1. Champs d'application & Cases

5.1 Applications recommandées

ApplicationTypical Working ConditionAvantages
Automatisation industrielleMotor control center, distribution cabinet, PLC systemTRMS measurement, perfect for non-linear loads with high precision
Bâtiments commerciauxClimatisation centrale, lighting system, elevator control3-phase 4-wire measurement, monitor unbalanced load, IP65 suit for machine room
Renewable EnergyPV inverter, wind power systemDemande & peak value monitoring, support single/three-phase systems
Centre de donnéesSystème UPS, server cabinet power distributionHaute précision, low power consumption 4.5VA, stable 24h operation
OEM EquipmentIndustrial machinery, équipement médical, testing instrumentStandard 96×96mm easy integration, optional RS485 communication

5.2 Not Recommended Applications

High voltage system (over 660V L-L, voltage transformer required)

High current system (over 6A, current transformer required)

Explosion hazardous area (non-explosion-proof design)

Underwater or long-term humid environment (only IP20 for terminals)

5.3 Application Cases

Cas 1: Motor Control Center Renovation for Automobile Factory

Original equipment: Analog pointer meters with inaccurate reading and no data recording

Solution: WM12-96.AV5.3.3.S with RS485 + SCADA system

Effect: Real-time monitor three-phase current, voltage and power, detect unbalanced load, save 15% énergie, annual electricity saving about 80,000 RMB

Cas 2: Energy Management System for Commercial Complex

Demande: Monitor power parameters of distribution cabinets on 12 floors, remote meter reading

Solution: 12 sets WM12-96.AV5.3.3.S connected to central controller via MODBUS bus

Effect: Auto generate energy consumption report, identify high-energy areas, optimize power distribution, save 20% energy yearly

  1. Air Shipment Compliance & Attestation

6.1 Shipping Confirmation

ArticleStatutExplication
Built-in Lithium BatteryNonExternal power supply only
Dangerous Goods ClassificationNon-dangerous goodsComply with IATA DGR rules, no special shipping limit
Transport RestrictionAucunShipped as general electronic goods
ConditionnementStandard anti-static packagePrevent static damage during transit

6.2 Certification Documents

CE Certificate: Available on official Carlo Gavazzi website (Doc ID:WM12 96 DS ENG 100317)

UL Certificate: Apply via global Carlo Gavazzi support center

Manufacturer Declaration: Include EMC, safety and RoHS compliance statement

  1. Lignes directrices de sélection
  2. Range Selection: AV5 for 400V system (380/660V L-L), AV6 for 100V system (120/208V L-L)
  3. Correspondance de puissance: Select A/B/C/3/D code according to on-site power supply to avoid damage
  4. Communication: Choose S version for remote monitoring, X version for local display only
  5. Montage: Panel cut-out size 61.4×61.4mm; current signal must connect via CT, direct connection forbidden
  6. System Setting: Reset via keypad to three-phase three-wire, ARON, two-phase or single-phase as required
  7. Accessoires assortis
AccessoireModèleFonction
Transformateur de courantCT-500/5500A/5A for large current measurement
Transformateur de tensionVT-400/100400V/100V for high voltage measurement
Module de communicationRS485-USBConnect meter to PC for parameter setting & data reading
Mounting KitWM12-MOUNTFixing screws and gaskets for panel installation
Configuration SoftwareGavazzi Config ToolRemote parameter setting and file generation

Full Model List of Carlo Gavazzi Multi-functional Power Meters

  1. General Coding Rule
SectionCodeSignification
SérieWM12-9696×96mm panel type
WM12-DINDIN rail type (4 modules)
GammeAV5380/660V L-L, 400V system
AV6120/208V L-L, 100V system
System1Monophasé
2Three-phase three-wire
3Three-phase four-wire
PouvoirA=24VAC, B=48VAC, C=115VAC, 3=230VAC, D=18-60VDC
FonctionX=No RS485, S=With RS485 MODBUS
  1. Complete WM12-96 & WM12-DIN Model List

WM12-96 Panel Mount

AV5 Series (400V System)

All single-phase / triphasé à trois fils / three-phase four-wire models with all power supply & communication options are fully listed as above.

AV6 Series (100V System)

Full range models are available in single-phase, three-phase three-wire and three-phase four-wire types.

WM12-DIN Rail Mount

Mainly three-phase four-wire AV5 & AV6 versions with all power supply and communication options.

  1. Extended High-end Models
ModèleFonctionnalitéNuméro de commande.
WM14-96.AV5.3.3.S15th harmonic analysisWM14-96AV533S
WM30-96.AV5.3.3.S0.2 haute précision, 32nd harmonic FFT analysisWM30-96AV533S