Numéro de commande: 104775
It belongs to the CES-AZ series, a Transponder Non-Contact Safety Evaluation Unit (intégré relais de sécurité). It adopts Unicode (single coding), which only recognizes the uniquely taught actuator. It supports up to 2 read heads.
Spécifications clés
Max.. number of read heads: 2 (CES-A-L… series read heads)
Niveau de sécurité: Catégorie 4 / PL e (EN ISO 13849-1)
Sorties de sécurité: 2 sorties de sécurité relais, chacun avec 2 internally series-connected NO contacts for redundancy
Coding type: Unicode (single coding); only the last taught actuator will be identified.
Multi-code alternative: CES-AZ-UES-02B (Numéro de commande. 105140, Multicode)
Additional interfaces: Start button monitoring (falling edge detection), external contactor feedback loop, TST test input, DIA diagnostic output, O1/O2 semiconductor status outputs
Montage: 35 mm rail DIN
Classe de protection: IP20 (only for cabinet installation)
Alimentation: C.C 24 V (21~27V DC regulated power supply, ondulation <5%)
Consommation d'énergie: Environ. 150 mA with relay energized
Terminaux: Plug-in coded terminals, wire cross-section 0.25–2.5 mm²
Température de fonctionnement: -20℃ ~ +55℃, pas de condensation, relative humidity ≤80%
Gross weight: 0.299 kilos
Code des douanes SH: 85364110
ECLASS: 27-27-24-03 Safety-related transponder switch
Définition du terminal
UB / 0V: Alimentation DC24V
J1, J2: Teach-in jumpers (to write actuator coding)
H11/H12, H21/H22: Signal for read head 1 & read head 2
SH1, SH2: Shield grounding for read heads
TST: Self-test input
S: Start button input (falling edge detection)
Y1/Y2: External feedback loop
13/14, 23/24: Two groups of safety relay outputs
DIA: Diagnostic output; O1/O2: Semiconductor status outputs for read heads
RESET pushbutton; Indicateurs LED: Pouvoir, H1, H2, OUT safety status, DIA fault diagnosis
Series Comparison Table
| Modèle | Numéro de commande. | Read Head Quantity | Coding Type |
| CES-AZ-AES-01B | 104770 | 1 | Unicode |
| CES-AZ-AES-02B | 104775 | 2 | Unicode (ce modèle) |
| CES-AZ-AES-04B | 104780 | 4 | Unicode |
| CES-AZ-UES-02B | 105140 | 2 | Multicode |
Scénarios d'application
Fonctionnalité de base
One evaluation unit monitors 2 safety gates/protection points simultaneously. The Unicode exclusive coding prevents bypass and replacement, ideal for high tamper-proof requirements. It works with non-locking CES read heads and locking CEM/CET safety interlocks (DANS 1088).
- Industrie des machines-outils (Le plus courant)
- Centres d'usinage, CNC milling machines & tours: Dual front + side safety doors. Immediate safe stop once any door opens. Paired with CET locking read heads to keep doors locked until spindle coasts to rest.
- Rectifieuses, high-speed saws & presses à poinçonner: Two protective covers for high-speed rotating and reciprocating motions, meeting PL e safety requirements.
- Laser cutting & machines de découpe plasma: Upper and lower material loading doors; laser emission is only enabled when both doors are fully closed.
- Lignes de production automatisées & Assembly Equipment
- Robot workcells (fencing): Two access gates for the robot enclosure; robot stops immediately if a gate opens during operation.
- Custom assembly machines, presses hydrauliques & riveting machines: Front maintenance door + side material feed door with interlock logic.
- Convoyeurs, machines de transfert & rotary lifting stations: Service access gate + bypass protection gate.
- Moulage par injection & machines de moulage sous pression: Mold safety door + barrel protective door with lock function to prevent opening during mold clamping and melt processing.
- Conditionnement, Impression, Batterie au lithium & 3C Equipment
- High-speed packaging, laminating & machines à refendre: Two rotary roller guard doors.
- Li-ion winding machines, machines de remplissage d'électrolytes & formation cabinets: Dual chamber doors to prevent high-voltage hazards and mechanical pinch injuries.
- Machines de placement CMS, AOI testers & FPC equipment: Front and rear maintenance hatches.
Avantage: Non-contact design with no mechanical wear, long service life and resistance to dust and oil contamination.
- Manutention des matériaux & Warehouse Equipment
- Vertical elevators & ascenseurs: Upper and lower level protective doors.
- Systèmes de tri & tris à bandes croisées: Two fence service doors.
- Small AGV and tooling trolley cabin hatches.
- Nourriture & Machines pharmaceutiques (Cleanroom Use)
- Machines de remplissage, bottle washers & machines à sceller: Dual clean chamber doors.
- Matériel de stérilisation: Chamber door + service door. Non-contact design avoids jamming and is easy to clean with no mechanical friction.
Note: Select stainless steel food-grade read heads for this application.
- Bancs d'essais & Laboratory Tooling
- High-voltage test stands & aging cabinets: Two safety hatches; Unicode coding prevents personnel from shorting safety circuits to access hazardous areas.
- Impact and durability test rigs: Dual protective enclosure doors.
Guide de sélection des modèles (Critique)
CES-AZ-AES-02B (Unicode)
Only recognizes the last taught actuator. Anti-tampering priority. For machines with safety audits and strict anti-bypass requirements.
CES-AZ-UES-02B (Multicode)
Accepts any actuator of the same series. Only used for position monitoring; easier maintenance without re-teaching after actuator replacement.
02B = Max. 2 read heads; choose 04B for 4 barrières de sécurité.
Recommended Matching Read Heads
CES-A-LNN: Non-locking type, only for door position monitoring
CEM: Process lock for production process protection
CET: Personnel safety lock (door locked until machine stops coasting; DANS 1088)
Applications inappropriées
Plus que 2 independent safety doors (select 04B or safety PLC instead)
Multiple gates requiring separate logic and different stop sequences (use a safety controller)
Simple door monitoring without anti-bypass requirements (UES version offers better cost performance)
EUCHNER CES-AZ-AES-02B (Numéro de commande. 104775) Full Technical Data
Taper: Unicode (single coding) non-contact transponder safety evaluation unit, maximum. 2 read heads
- Commande & Coding Information
Numéro de commande: 104775
Coding type: Unicode (unique coding); only the last taught actuator will be recognized to prevent bypass replacement
Supported read heads: 2 unités (CES-A-L… / CEM / CET series)
ECLASS: 27-27-24-03
Code des douanes SH: 85364110
- Performances de sécurité (EN ISO 13849-1 / ET CEI 62061)
Safety category: Catégorie 4
Performance level: PL e
SIL rating: SIL 3
PFHd: 1.3×10⁻⁸
Mission time: 20 années
Safety architecture: Dual redundant relay safety outputs; each channel has 2 internally series-connected monitored NO contacts
- Paramètres électriques
- Supply voltage UB: DC 21~27V, rated DC24V (regulated power supply, ondulation <5%), UL Class 2 power supply required
- Consommation d'énergie: Environ. 150 mA with relay energized (excluding load of monitoring outputs)
- Relay safety outputs (13/14, 23/24)
Tension d'isolement nominale: 250 V et
Max.. switching voltage: 250 V et / 30 À DC
Continuous thermal current Ith: 8 UN
AC-15: 6 UN / 230 V et; DC-13: 4 UN / 24 À DC
- External feedback loop Y1/Y2
Loop current: 5~8~10 mA
Max.. allowed loop resistance: 600 Oh
- Entrées numériques (S Start, TST Test)
Niveau bas: 0~2 V DC; Haut niveau: 15~27 V DC
- Semiconductor monitoring outputs O1/O2, DIA
Taper: Sortie transistorisée NPN, NOT safety outputs
Max.. courant de charge: 100 mA
- Terminaux: Plug-in coded spring terminals, wire cross-section 0.25–2.5 mm²
- Recommended external fuse: Max.. 8A gG
- Mécanique & Données environnementales
Dimensions hors tout: 114 × 99 × 45 mm
Matériau du boîtier: PA6.6 engineering plastic
Poids: Environ. 0.25 kilos
Montage: 35 mm rail DIN (EN60715 TH35)
Classe de protection: IP20 (cabinet-only installation)
Degré de pollution: 2
Température ambiante de fonctionnement: -20 ℃ ~ +55 ℃
Humidité relative: ≤80%, pas de condensation
Position de montage: Toute orientation
- Interfaces & Indicateurs
Terminaux: UB/0V power, H11/H12 (read head 1), H21/H22 (read head 2), SH1/SH2 shield, S Start, TST Test, Y1/Y2 feedback, 13/14 & 23/24 safety outputs, O1/O2 read head status, DIA diagnosis
Operating elements: RESET pushbutton, J1/J2 teach-in jumpers
Indicateurs LED: Pouvoir, H1, H2, OUT safety status, DIA fault diagnosis
- Read Head Compatibility
Reliable operating distance Sar: Max.. 26 mm (depends on read head model)
Compatible types: Non-locking door monitors CES-A-LNN / CES-A-LCA; process interlocks CEM; personnel safety interlocks CET (DANS 1088)
- CEM & Normes de conformité
EMC standard: ET CEI 60947-5-3
Normes applicables: EN ISO 13849-1, ET CEI 62061, DANS 1088 (for guard lock applications)
- Différenciation des modèles
CES-AZ-AES-02B: Unicode, anti-replacement, Cat.4 / PL e
CES-AZ-UES-02B (105140): Multicode, accepts any same-series actuator, entretien plus facile
EUCHNER Safety Relay / Evaluation Unit Model & Order Number List
Two main product lines: ESM standalone safety relays (usage général) and CES-AZ transponder evaluation units (votre modèle cible), plus CES-AR series for serial connection.
Note: CES-AZ is a transponder decoding safety evaluation unit, generally referred to as a safety relay in the industry. All models meet Cat.4 / PL e (EN ISO 13849-1).
- ESM Series General Safety Relays (Arrêt d'urgence, barrière de sécurité, commande à deux mains, extension des contacts)
1) ESM-BA Non-Time-Delay Basic Modules (Cat.4)
| Modèle | Numéro de commande. | Description |
| ESM-BA201 | 85610 | 2 sécurité contact NO, bornes à vis |
| ESM-BA201P | 97226 | 2 sécurité contact NO, plug-in terminals |
| ESM-BA301 | 85613 | 3 NON + 1 contact auxiliaire, bornes à vis |
| ESM-BA301P | 97230 | 3 NON + 1 contact auxiliaire, plug-in terminals |
| ESM-BA701 | 97224 | 7 sécurité contact NO, bornes à vis |
| ESM-BA701P | 97225 | 7 sécurité contact NO, plug-in terminals |
2) ESM-BT Time-Delay Modules (Cat.4, adjustable 1~30s; fixed-delay versions available)
| Modèle | Numéro de commande. | Description |
| ESM-BT401 | 90818 | 1 instantané + 3 delayed outputs |
| ESM-BT411 | 90819 | 2 instantané + 2 delayed outputs |
| ESM-BT411-20S | 90077 | 2 instantané + 2 delayed outputs, fixed 2s delay |
| ESM-BT421 | 90820 | 3 instantané + 1 delayed output |
| ESM-BT421-50S | 90094 | 3 instantané + 1 delayed output, fixed 5s delay |
3) ESM-2H Two-Hand Control Modules (EN574 / Type IIIC)
| Modèle | Numéro de commande. | Description |
| ESM-2H201 | 85620 | Commande à deux mains, 2 contacts de sécurité |
| ESM-2H202 | 98345 | Commande à deux mains, 2 contacts de sécurité |
4) ESM-ES Contact Expansion Modules (Non-delay, used with BA/BT main units)
| Modèle | Numéro de commande. | Description |
| ESM-ES301 | 85614 | 3NON + 1 auxiliaire, bornes à vis |
| ESM-ES302 | 85615 | 3NON + 1 auxiliaire, 230V et |
| ESM-ES303 | 85616 | 3NON + 1 auxiliaire, 115V et |
| ESM-ES301P | 90057 | 3NON + 1 auxiliaire, plug-in terminals |
5) ESM-TE Time-Delay Expansion Modules
| Modèle | Numéro de commande. | Description |
| ESM-TE301 | 85617 | Delay expansion, adjustable 1–30s |
| ESM-TE303 | 85619 | Delay expansion, 230V et |
| ESM-TE301-05S | 97223 | Fixed 0.5s delay expansion |
6) ESM Accessories
| Modèle | Numéro de commande. | Description |
| ESM-F-AK4 | 97194 | Screw terminal kit for ESM-P |
| ESM-F-KK4 | 97195 | Spring terminal kit for ESM-P |
- CES-AZ Series Transponder Evaluation Units (Unicode AES anti-tamper / Multicode UES general type)
AES = Unicode (only recognizes taught actuators, anti-bypass); UES = Multicode (accepts any same-series actuator, entretien facile)
| Modèle | Numéro de commande. | Read Head Count | Coding Type |
| CES-AZ-AES-01B | 104770 | 1 | Unicode |
| CES-AZ-AES-02B | 104775 | 2 | Unicode (votre modèle) |
| CES-AZ-AES-04B | 104780 | 4 | Unicode |
| CES-AZ-UES-01B | 105139 | 1 | Multicode |
| CES-AZ-UES-02B | 105140 | 2 | Multicode |
| CES-AZ-UES-04B | 105149 | 4 | Multicode |
| CES-AZ-ABS-01B | 100064 | 1 | Old Unicode version, Cat.3 |
III. CES-AR Serial Link Evaluation Unit (Max.. 12 AR read heads wired in series)
| Modèle | Numéro de commande. | Description |
| CES-AR-AES-12 | 98225 | Jusqu'à 12 AR read heads in series, Cat.4 PL e |
Guide de sélection rapide
- ESM-BA/BT: General safety relays for E-stop, regular safety gates and light curtains; no transponder decoding function.
- CES-AZ-AES: Transponder-only type, anti-replacement & anti-cheating; for machine tools and automation with strict anti-bypass requirements.
- CES-AZ-UES: Transponder-only type; no re-teaching needed after actuator replacement, preferred for mass-produced equipment.
- CES-AR-AES-12: Long-distance serial connection for multiple safety gates, reduces wiring work.
I can export this whole text into pure plain text (without tables) for direct copy to Excel, or provide the wiring diagram + fault LED troubleshooting list in English. Do you need that?
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur























NH42-63-318x560.png)