Patte 378 FC Non-Contact True-RMS Clamp Meter with PQ Power Quality Screening - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Patte 378 FC Non-Contact True-RMS Clamp Meter with PQ Power Quality Screening - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

électrique/

Patte 378 FC Non-Contact True-RMS Clamp Meter with PQ Power Quality Screening

Troubleshooting of industrial control, motors and inverter power distribution, plus harmonic screening and three-phase testing. It shares identical hardware with the 377 FC, while the 378 FC exclusively features PQ power quality indication. Core Technology: FieldSense™ Electric Field Sensing Technology. No physical contact between the clamp jaw and live conductors. Simply connect a ground lead ...

  • Détails du produit

Troubleshooting of industrial control, motors and inverter power distribution, plus harmonic screening and three-phase testing. It shares identical hardware with the 377 FC, while the 378 FC exclusively features PQ power quality indication.

Core Technology: FieldSense™ Electric Field Sensing Technology. No physical contact between the clamp jaw and live conductors. Simply connect a ground lead to measure voltage and current simultaneously, greatly reducing electric shock risks.

Spécifications clés

Cote de sécurité: CAT III 1000 V / CAT IV 600 V

Clamp Jaw AC Current: 0~999.9 A, résolution 0.1 UN; précision 2% ±5 digits (45–66 Hz)

Sonde flexible iFlex (Standard i2500-18, 1.8 m): AC 0~2500 A, ideal for busbars, compact switchgear and large cables

Tension CC: 0~1000 V; Tension CA: 0~1000 V (direct probe measurement); FieldSense non-contact voltage up to 1000 V

Gamme de fréquences: 5 Hz~500 Hz, compatible with inverters, variable-speed motors and UPS systems

Résistance: 60 kΩ; Capacitance: 1000 µF; Continuity beep; Inrush startup current capture, MIN/MAX/Average value recording

Vrai-RMS (TRMS) mesures, designed for non-linear loads such as inverters, servo drives and switching power supplies

Ouverture de la mâchoire: 34 mm; Poids net: 463 g; Alimentation: 2×AA batteries, battery life 200 heures

Wireless Connectivity: Patte Connect Bluetooth. Save data, perform automatic three-phase calculations, phase sequence verification and cloud storage via mobile APP

Exclusive Functions (Difference from 377 FC)

✅ PQ Power Quality Indicator: Automatically detects voltage, current and power factor anomalies under FieldSense mode. Quickly identify whether the fault originates from upstream grid supply or downstream motor/inverter loads (early warning for harmonics, three-phase imbalance and poor power factor)

✅ Automatic Three-Phase Test: Complete three-phase measurement in 3 mesures. The APP automatically calculates line-to-ground, line-to-line voltages, phase sequence and unbalance without manual recording and calculation

✅ Inrush Startup Current: Capture the closing surge current of motors and compressors to diagnose mechanical jamming and faulty starting circuits

Accessoires standards

Patte 378 FC Clamp Meter Main Unit

i2500-18 iFlex Flexible Current Probe (1.8 m)

TL224 Test Leads, TP175 TwistGuard Test Probes, AC285 Grounding Clip (required for FieldSense function)

TPAK Magnetic Hanging Kit, Hard Carrying Case, Manuel d'utilisation

Comparaison des modèles & Guide de sélection

377 FC: Equipped with FieldSense, without PQ power quality screening, focused on safe and fast voltage & current measurement

378 FC: With PQ harmonic & energy efficiency screening, the top choice for maintenance of inverters, air compressors and fans

376 FC: Traditional clamp meter, no FieldSense non-contact voltage function, voltage measurement only via test probes

Numéro de commande: 5111812 (FLUKE-378 FC)

Applications typiques (Automation / CVC / Low-Voltage Assemblies)

Harmonic and three-phase current imbalance screening for inverter and servo drive outputs

Measurement of startup current and locked-rotor diagnosis for three-phase motors, compresseurs d'air, water pumps and fans

High-current testing on low-voltage switchgear, busbars and large cables (2500 A via iFlex probe)

Maintenance prédictive, power quality pre-screening and fault location (grid side vs equipment side)

Commissioning and phase sequence verification for star-delta and soft-start circuits

Limites & Remarques

  1. FieldSense mode requires reliable grounding. Poor grounding will cause inaccurate voltage readings; only works on single-phase conductors
  2. The PQ function is only a screening indicator, providing pass/alarm alerts only. It cannot replace professional power quality analyzers (Fluke 43B / 437-Ii) for detailed THD harmonic reports
  3. The iFlex flexible probe has a higher minimum measuring current and is not suitable for measuring tens of milliamps small currents
  4. FieldSense cannot be used for DC voltage measurement

Mise à niveau & Options alternatives

Brand Upgrade: Fluke 43B / 437-II Power Quality Analyzer (for detailed harmonic analysis and waveform recording)

Equivalent domestique: High-end clamp meters with flexible probes, Bluetooth and harmonic screening (note: no FieldSense non-contact voltage function)

Des pièces de rechange: Separate i2500-18 probe, TP175 test probes, AC285 grounding clip

Fluke 378FC / 377FC / 376FC Note

For detailed harmonic reports, fine harmonic waveform recording and transient disturbance testing, you need professional instruments such as the Fluke 43B / 437-Ii.

If you frequently maintain inverters, three-phase motors and water chillers, and require safe non-contact measurement plus fast power quality troubleshooting, choose the 378 FC. If you only need non-contact measurement without PQ screening, select the 377 FC.

FC = Fluke Connect Bluetooth wireless for mobile APP data logging; non-FC models are wired-only versions.

Liste complète des modèles (Fluke Clamp Meters)

  1. Industrial High-End Series (370 Série, TRMS AC/DC + iFlex high-current)

Non-Contact Voltage Models (FieldSense for safer cabinet testing)

377 FC: Tension sans contact & current measurement, no PQ harmonic screening

378 FC (votre modèle): 377 FC plus PQ power quality harmonic screening, preferred for inverters & moteurs

Standard Wireless Models (No Non-Contact Voltage)

374 FC: 600 Un AC/DC, supports iFlex (flexible probe not included)

375 FC: Built-in VFD low-pass filter for more accurate inverter measurement (no iFlex included)

376 FC: 1000 Un AC/DC, standard with i2500 iFlex probe, maximum 2500 Et clim

Remote Detachable Display

381: Separable display for one-person operation in high-altitude and tight spaces, standard with iFlex

  1. Industry-Specific Models
  2. HVAC Special: 902 FC

For refrigeration, fans and heat pumps, with temperature measurement, CAT IV 300 V rating

  1. PV New Energy Special: 393 FC

CAT III 1500 V DC rating, designed for PV string DC testing

  1. Leakage Current Meters (Ground Leakage & Neutral Harmonic Current)

368 / 369 FC: Large jaw micro-amp leakage clamp meters, used for equipment earth leakage and neutral line current testing

  1. Detachable Jaw for Tight Wiring Harnesses: 365

Separate jaw via flexible cable to access dense wiring; 200 A AC/DC true-RMS

  1. General Economy Models (Daily Electrician Inspection)
  2. Ultra-Thin Blade Jaw (narrow wiring): 301A/301C (AC only), 301D/301E (AC+DC)
  3. High Current for Automotive & Systèmes électriques: 317, 319 (1000 A AC/DC TRMS)
  4. Heavy-Duty High-Current Industrial Models: 353, 355 (2000 UN, for transformers and busbars)
  5. Complete Full Model List

370 Industrial Series

373, 374, 374FC, 375, 375FC, 376, 376FC, 377FC, 378FC, 381

Small Jaw / Split Jaw Models

362, 365

Leakage Current Clamps

368, 369FC

Ultra-Thin Blade Series

301UN, 301B, 301C, 301D, 301E, 302+, 303, 305

General AC/DC Models

312, 317, 319

Heavy-Duty High-Current Models

353, 355

Industry-Dedicated Models

902 FC (CVC), 393 FC (PV)

Process Signal Clamp Meters (4–20 mA Loop)

771, 772, 773 (for transmitter loop current measurement)

Résumé de la sélection rapide

Variable-speed motors + harmonic screening + non-contact safety → 378 FC

Non-contact measurement only, no harmonic analysis → 377 FC

General high-current measurement + flexible probe + Bluetooth → 376 FC

Remote separate reading → 381

HVAC air conditioning maintenance → 902 FC

1500 V DC PV measurement → 393 FC

Précédent:

Laisser une réponse

Laisser un message