Numéro de modèle complet: PN-100-SER14-QFRKG/US/ /V PN7032 belongs to PN70xx series, a relative pressure sensor with digital display, two switching outputs and IO-Link on one channel. It adopts ceramic-capacitive measuring cell, widely used for pressure switches and transmitters in industrial hydraulic and pneumatic systems. ✅ Key Specifications Item Parameter Measuring range 0…10 MPa (0~100 bars), relatif ...

  • Détails du produit

Numéro de modèle complet: PN-100-SER14-QFRKG/US/ /V

PN7032 belongs to PN70xx series, a relative capteur de pression with digital display, two switching outputs and IO-Link on one channel. It adopts ceramic-capacitive measuring cell, widely used for pressure switches and transmitters in industrial hydraulic and pneumatic systems.

✅ Spécifications clés

ArticleParamètre
Plage de mesure0…10 MPa (0~100 bars), relative pressure
Connexion au processusFiletage interne G1/4; rotatable display head
Measuring elementCeramic-capacitive
Overpressure30 MPa; Pression d'éclatement 65 MPa
Sortir2 x PNP switching outputs; OUT2 multiplexed for IO-Link
Alimentation18…30 V DC; protection contre l'inversion de polarité & protection contre les courts-circuits
Température moyenne-25 ~ +80 ℃
Protection contre la pénétrationIP67; M12 A-coded 5-pin gold-plated connector
Afficher4-digit red/green digital display, tri-color status indicator, 3-key menu
Switch settingPS: 0.1~10 MPa; rP reset point; minimum hysteresis 0.05 MPa
Response frequencyMax.. 170 Hz
MoyenPrimarily for liquids; gas applications above 25 bar require separate evaluation

✅ Explication du code modèle

PN-100-SER14-QFRKG/US/ /V

PN: Series with display

100: Measuring range 0~10 MPa

S: 2 switching outputs

E: IO-Link function

R.: Filetage interne G1/4

14: M12 5-pin electrical connector

QFRKG: Code for housing, sealing and electrical configuration

✅ Product Features

  1. Communication IO-Link: Read real-time pressure, temperature and diagnostic data; remote parameter read/write via PLC, device identification and fault diagnosis supported.
  2. Rotatable display head for convenient viewing after installation.
  3. Red/green color-changing display: green within valid pressure range, red when threshold exceeded.
  4. Ceramic cell, good resistance to pressure spikes and excellent long-term stability.
  5. Two independent switch points for high/low pressure dual alarm.
  6. Built-in short-circuit and reverse polarity protection, adapté aux environnements industriels difficiles.

✅ Applications typiques

Hydraulic station pressure monitoring, lube oil circuits, cooling water systems, high-pressure pneumatic loops, machines de moulage par injection, machines-outils, stations de pompage, compresseurs d'air.

✅ Reference Replacement Models

PN7032 (0~10MPa, Filetage interne G1/4, IO-Link)

PN7033: 0~2.5MPa

PN7034: 0~1MPa

PN7036: 0~0.25MPa

Note: PN7032 is partially phased out. Pour les nouveaux projets, consult IFM PN72 series alternatives. Fil, measuring range, IO-Link and output logic need to be verified.

✅ Pin Assignment (M12 5-pin A-coded)

1: Power +18~30V DC

2: SORTIE1 (PNP switch)

3: Power GND

4: SORTIE2 / IO-Link

5: Non utilisé

✅ Dépannage courant

  1. Pas d'affichage: Check supply voltage and confirm no reverse connection.
  2. Pressure reading drift: Verify medium temperature and pressure spikes upstream; ceramic cell is vulnerable to continuous overpressure.
  3. IO-Link communication failure: Check pin 4, IO-Link master baud rate and matched IODD file.
  4. Switch output not actuating: Enter menu to verify SP/rP setting and output mode (window / hystérèse).

Tableau de comparaison: IFM PN7032 vs PN72 Series (PN7292, Remplacement direct)

PN7032: PN-100-SER14-QFRKG/US/ /V (abandonné)

PN7292: PN-100-REN14-QFRKG/US/ /V (official recommended replacement, 0~10MPa, Filetage interne G1/4, 2×PNP + IO-Link)

Article de comparaisonPN7032PN7292 (PN72 Series Replacement)Remarques
Modèle completPN-100-SER14-QFRKG/US/ /VPN-100-REN14-QFRKG/US/ /VPlage de mesure identique: 0…10 MPa (0~100 bars) relative pressure
Measuring CellCeramic-capacitiveCeramic-capacitiveMême, resistant to pressure spikes, suitable for hydraulic/lube oil
Connexion au processusFiletage interne G1/4Filetage interne G1/4Mechanically fully compatible, direct swap-in
Electrical ConnectorM12 A-coded 5-pinM12 A-coded 5-pinPinout identical, no cable rework required
Configuration de sortie2×PNP switching outputs, OUT2 multiplexed IO-Link2×PNP switching outputs, OUT2 multiplexed IO-Link; output software-selectable PNP/NPNPN72 adds PNP/NPN software switching
Alimentation18…30 V DC18…30 V DCSame range, reverse polarity & protection contre les courts-circuits
Overpressure30 MPa30 MPaIdentique
Burst Pressure65 MPa65 MPaIdentique
Température moyenne−25 ~ +80 ℃−25 ~ +80 ℃Même plage de température
Protection contre la pénétrationIP67IP67Same housing protection
Afficher4-digit red/green digital display, tri-color status, 3 clés4-digit red/green LED, side status indicators, 3 clésSame display logic; display head 360° rotatable
IO-Link VersionIO-Link 1.1IO-Link 1.1IODD files differ; PLC project needs IODD update
Switch Point SetupPS, rP hysteresis; min hysteresis 0.05 MPaPS, rP hysteresis; min hysteresis 0.05 MPaMenu logic mostly consistent; PN72 supports more pressure units
Fréquence de réponseMax.. 170 HzMax.. 170 HzSame dynamic response
Dimension globaleIdentical body outlineIdentical body outlineNo modification to mounting space or bracket
Différences clésFixed PNP outputSoftware PNP/NPN toggle; more menu parameters; extended diagnostic information; improved service life (>100 million pressure cycles)✅ Direct replacement for most applications; ⚠️ IO-Link projects require IODD update

PN72 Series Selection List for PN70xx Equivalents

Plage de mesureOriginal PN70xx ModelPN72 Series ReplacementFil
0~10 MPa /100 barPN7032PN7292Filetage interne G1/4
0~2.5 MPa /25 barPN7033PN7293Filetage interne G1/4
0~1 MPa /10 barPN7034PN7294Filetage interne G1/4
0~0.25 MPa /2.5 barPN7036PN7296Filetage interne G1/4

⚠️ Replacement Engineering Notes

  1. Installation mécanique: Thread and physical dimensions are identical; can be directly screwed into existing piping.
  2. Câblage électrique: M12 5-pin pinout fully identical, no cable modification needed.
  3. Switch-only Application (No IO-Link): Remplacement direct, re-set SP/rP parameters only; PLC program unchanged.
  4. IO-Link Application: IODD file update mandatory. PN7032 and PN7292 IODD are not interchangeable; different device ID, PLC will recognize it as new equipment.
  5. Type de sortie: PN7032 fixed PNP; PN7292 factory default PNP, can be switched to NPN via menu.
  6. Pressure Units: PN72 supports more units (bar/MPa/psi etc.), older PN7032 has fewer unit options.
  7. Media Note: Ceramic cell, avoid strongly corrosive media; high-pressure gas applications require separate evaluation.

Limitation Statement

PN72 series (PN7292) is functionally compatible replacement instead of 100% firmware identical. Diagnostic parameters and device ID read via IO-Link differ. For pure switch signals, zero-modification replacement; IO-Link projects require PLC IODD update and parameter download.

Complete Installation Instructions for IFM PN7032 Pressure Sensor

PN7032: Filetage interne G1/4, M12 A-coded 5-pin, ceramic cell, gauge pressure 0~10MPa; Depressurize system and cut off power before installation

  1. Préparation avant l'installation
  2. Safety Check

Shut down and depressurize piping; confirm medium, temperature and maximum pressure do not exceed PN7032 specification (medium -25~80℃, overpressure 30MPa).

  1. Pressure Tap Selection

Liquid medium: Tap taken from side of pipe to prevent air bubbles accumulating on measuring cell.

Gas medium: Tap taken from top of pipe to avoid liquid pooling on cell.

Avoid locations after pumps, valves and elbows with pressure spikes and high turbulence. Add snubber/damper under heavy vibration to protect ceramic cell.

  1. Piping Pre-treatment

Purge piping to remove metal chips and weld slag; debris can scratch ceramic diaphragm and cause zero drift.

  1. Sealing Parts Preparation

G1/4 is parallel pipe thread. Do NOT wrap large amount of PTFE tape. Copper gasket or O-ring is preferred. A small amount of thread sealant is allowed, but sealant must not squeeze into pressure chamber, which will permanently damage the cell.

  1. Outils: Clé dynamométrique, M12 pre-assembled cable, spanner.
  2. Montage mécanique (Pressure Piping Connection)
  3. Align sensor G1/4 thread with pipe fitting, hand-tighten first. Do NOT use spanner on plastic display housing directly.
  4. Couple de serrage recommandé: 25~35 N·m. Must use torque wrench. Excessive torque causes housing deformation and ceramic cell cracking; insufficient torque causes leakage.
  5. Display Head Rotation: After tightening thread, the electronic display head can be rotated 345° for optimal viewing angle. Do not rotate beyond mechanical end stop, forced rotation damages internal wiring.

⚠️ Remarque: Rotate the upper display head, NOT the pressure thread base.

  1. Après l'installation, pressurize slowly and check thread for leakage.
  2. Câblage électrique (M12 A-coded 5-pin)

Perform wiring with power OFF. IFM original M12 prefabricated cable recommended. M12 connector tightening torque: 0.6~1.2 Nm to maintain IP67.

Numéro de broche.Couleur du filDéfinitionRemarques
1BN BrunDC+ 18~30VPuissance positive
2WH WhiteSORTIE1 (Sortie de commutation PNP)Switch channel 1
3Bleu BUCC- GNDPuissance négative
4BK NoirSORTIE2 / IO-LinkCanal 2, IO-Link multiplex port
5—Non utiliséSpare pin

Sortir: 2×PNP, max load current 250mA per channel.

IO-Link usage: Épingle 4 for IO-Link communication.

Recommandation de câble: 0.34~0.5mm². Route IO-Link wiring away from frequency converters and high-power power cables to reduce interference.

  1. Mise sous tension & Mise en service
  2. Double-check wiring for correctness and short circuit; fasten M12 connector.
  3. Apply DC24V power slowly, display lights up.
  4. Menu configuration: Set switch point SP, reset point rP, select window / hysteresis mode and pressure unit.
  5. Zero point verification: Confirm reading near 0 bar when piping is depressurized.
  6. Pressurize gradually, verify pressure reading and switch output actuation.
  7. IO-Link application: Import IODD file in PLC, identify device, read pressure, temperature and diagnostic parameters.
  8. Interdictions d'installation critiques (Engineering Key Points)
  9. ❌ Do NOT mount or demount sensor under pressure; high-pressure ejection may injure personnel and damage equipment.
  10. ❌ Do NOT use spanner on plastic display housing to tighten thread; only clamp lower metal thread base.
  11. ❌ Heavy PTFE tape on G1/4 thread; debris entering pressure chamber scratches ceramic cell.
  12. ❌ Over-tightening torque, may fracture ceramic measuring element.
  13. ❌ Direct medium impact above 80℃; add cooling buffer for high-temperature media.
  14. ❌ Operation under heavy shock and continuous vibration without snubber, leading to zero drift and shortened service life.
  15. ❌ Hot plug/unplug M12 connector, risk of burning output circuit.
  16. Post-installation Check List

No leakage at thread connection

M12 connector tightened, IP67 intact

Tension d'alimentation: 18~30 V CC

No short circuit or reverse polarity

Zero reading normal with no applied pressure

Switch point action normal / IO-Link communication stable

  1. Replacement Hint for PN7292

Montage mécanique, fil, torque and M12 pinout are fully identical; piping and cables remain unchanged. Only IO-Link projects require IODD file update.