Marque: KIEPE Elektrik, Allemagne
Nom du produit: Bidirectional Pull-Rope Emergency Stop Switch / Conveyor Line Rope Pull Emergency Stop Switch
Numéro de commande: 91.063293001
Série de produits: PRS Pull-rope Emergency Stop Switch (Latching Pull-Rope E-Stop)
- Définition du modèle
PRS = Pull Rope Switch
001: Version de base, without built-in indicator lamp
Same series comparison:
PRS001: 2Caroline du Nord + 1SPDT (No Indicator)
PRS101: Avec 230 VAC indicator lamp
PRS102: Avec 24 VDC indicator lamp
- Core Electrical Configuration
Contact Arrangement: 2 sets of positively opened normally closed contacts (2Caroline du Nord) + 1 set of changeover contact (1SPDT)
Conception de sécurité: Positive Opening Contacts, Mechanical Latching Structure
Mode d'actionnement: Bidirectional rope actuation (triggered by pulling rope on either side)
Méthode de réinitialisation: Mechanically latched after tripping; manual reset via the blue reset lever
Tripping Force: 30 N ±10 N
Maximum permissible rope length per side: 50 m; total maximum rope length on both sides: 100 m
Cable Entries: 3 × M25×1.5 metric threaded cable glands
Acceptable conductor cross-section: Max.. 2.5 mm²
- Electrical Load Ratings
AC-15: 230 V / 1.5 UN
DC-13: 24 V / 2 UN
Tension assignée d'isolement Ui: 250 V
Durée de vie mécanique: ≥ 200,000 cycles de fonctionnement
Safety Performance Level: Up to PL d / SIL2 (subject to safety circuit architecture)
- Mécanique & Spécifications environnementales
Enclosure: Glass fibre reinforced PBT thermoplastic, yellow housing (RAL1004)
Red lever: Trip release lever
Blue lever: Manual reset lever
Protection contre la pénétration: IP65 / IP67
Température de fonctionnement: -25 ℃ ~ +70 ℃
Montage: Two-point fixing with M6 bolts; maximum allowable mounting inclination ≤15°
Poids: Environ. 480 g
- Normes conformes
DIN EN 60947-5-5, EN ISO 13850, DANS 620, BGI710, EN60204-1
Fully satisfies safety specifications for belt conveyors used in power plants, ports, industries métallurgiques et cimentières.
- Scénarios d'application typiques
Convoyeurs à bande longue distance, bucket elevators and bulk material handling production lines. Units are mounted along the conveyor frame, enabling operators to trigger emergency shutdown by pulling the wire rope at any position along the line.
- Directives de câblage (Critical Safety Notes)
- Route the two NC normally closed contacts in series for the emergency stop safety circuit (dual-channel safety circuit);
- The SPDT changeover contact is generally used for fault alarm signalling;
- The switch latches mechanically after actuation. Automatic reset is not possible. Manual reset is only permitted after hazard inspection and confirmation.
- Wire rope installation must include tension springs, rope clamps and support hangers to prevent false tripping caused by slack wire rope.
Applicable Industries for KIEPE PRS001 Bidirectional Pull-Rope Emergency Stop Switch
PRS001 is a heavy-duty latching line-mounted emergency stop device complying with EN 620 & OIN 13850. Featuring IP67 protection and corrosion-resistant glass fibre reinforced housing, it is specially designed for safety protection on long-distance bulk material belt conveying systems, suitable for high-dust, outdoor humid and mildly corrosive environments.
- Heavy Industry Bulk Material Conveying (Demande principale)
- Thermal Power Plants
Coal handling belt conveyors, coal crushers, stacker-reclaimers, élévateurs à godets; standard safety equipment for coal conveyor galleries.
- Ciment & Industrie des matériaux de construction
Raw material conveyors, clinker production lines, limestone transport and aggregate yard belt conveyors.
- Ports & Bulk Cargo Terminals
Belt conveyors for coal, ore and grain handling, ship loaders and yard stacker-reclaimer conveying lines; well adapted to outdoor high-humidity and salt spray environments.
- Industrie minière (Open-pit Mines Only)
Long-distance belt conveyors for open-pit coal mines, sandstone mines and metal mines.
⚠️ Explosion-proof certified KIEPE TEX series is required for underground mining; PRS001 carries no Ex certification and cannot be deployed underground.
- Iron & Acier / Metallurgical Plants
Sintering, pelletizing and blast furnace raw material conveyors, coke plant material handling systems; resistant to high temperature and dust conditions.
- Chimique & Salt Resource Industries
- Chimique & Fertilizer Plants
Belt conveyors for solid raw materials including urea and phosphate chemicals;
- Potash Mines, Rock Salt Mines & Salt Lake Operations
A prioritized application field per manufacturer documentation. The housing provides good salt spray resistance for salt mine conveying lines.
III. Grain, Agriculture & Environmental Solid Waste Sectors
- Grain Silos & Grain Processing Facilities
Grain transfer conveyors and bulk grain handling lines at terminals;
- Waste-to-energy Plants, Recycling & Composting Facilities
Solid waste conveyors and refuse feeding belts, capable of operating under humid, conditions poussiéreuses.
- Other General Conveying Applications
Large automated logistics parks and ore screening lines;
Aggregate quarries and fly ash conveying systems;
Bulk cargo handling equipment at inland river terminals.
✅ Suitable Equipment Types
Convoyeurs à bande, élévateurs à godets, scraper conveyors, stacker-reclaimers, shuttle belts, tripper cars and other long-distance continuous conveying machinery.
⚠️ Application Restrictions (Key Selection Guidance)
- PRS001 has no Ex explosion-proof certification. Deployment is prohibited in underground coal mines and workshops with flammable gas atmospheres. Select KIEPE TEX explosion-proof variants for hazardous areas.
- Additional assessment of housing chemical resistance is required for environments with persistent strong acid corrosion.
- Primarily intended for ground/outdoor conveying equipment; compact high-speed enclosed production lines should adopt conventional emergency stop pushbuttons instead.
Official Service Life of KIEPE PRS001 (91.063293001) — Parameters from Original Datasheet
- Durée de vie mécanique (Full Operating Cycle)
≥ 200,000 cycles de fonctionnement
Définition: One full cycle consists of rope pull actuation followed by manual reset; covers the durability of internal latching cams, springs and operating levers.
- Electrical Contact Life (B10d per Safety Standard EN ISO 13849: Cycle count where maximum 10% of units develop dangerous failure)
DC-13 duty (24 À DC / 2 UN, most common for conveyor control circuits): B10d = 200,000 cycles
AC-15 duty (230 V et / 1.5 UN): B10d = 840,000 cycles
⚠️ B10d is a critical parameter for safety components, used for safety circuit calculation to achieve PL d / SIL2.
- Reference Service Life in Practical Field Operation
Pull-rope emergency stop switches are safety backup devices and rarely triggered under normal operating conditions. Most conveyor installations record fewer than 10 actuations per year:
Standard environments (centrales électriques, cement plants, ports): Reliable service life 8 ~ 12 years is common;
Severe duty conditions (forte poussière, continuous vibration, outdoor salt spray, extreme temperature cycling): Functional assessment recommended every 6 ~ 8 années;
Frequent manual pull testing is prohibited, as repeated operation accelerates mechanical and contact wear.
- Facteurs clés affectant la durée de vie
- Rope tension: Excessively taut wire rope imposes continuous lateral load on the operating mechanism and accelerates pivot wear;
- Dust and moisture ingress: Although rated IP67, long-term dust accumulation in pivot gaps increases friction;
- Mechanical vibration: Severe vibration from belt conveyors causes fatigue of internal moving components;
- Contact switching duty: Do not use the switch to interrupt high-power main circuits; only connect to control signal circuits.
- Entretien & Recommandations de remplacement
Annual inspection: Contrôle visuel, seal integrity, rope tension and functional actuation test;
Plan spare replacement when total actuations approach 150,000 cycles OR service life reaches 8 années;
Immediately decommission and replace the switch if reset jamming or intermittent contact signals occur. Do not continue operation within safety circuits.
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires