Application Scenarios of OMRON F3SG-4RE1630P30 (1630mm Height, 30mm Hand Protection, Type4 PL e)
This light curtain features 1.63m protective height and 30mm detection resolution dedicated to hand protection, with highest safety Category 4 / SIL 3. It has no muting function and only basic OSSD outputs, suitable for equipment requiring physical barrier to stop hands entering hazardous areas, covering machining, automation, logistique, rubber & plastique, robot industries:
- Estampillage & Forging Equipment (Core High-Risk Applications)
- Safety protection for operating openings of air/hydraulic presses
- Safety isolation at feed inlets of press brakes & plate shears
- Material pick-up stations for hot & cold forging machines
Caractéristiques: 1630mm height fully covers hand intrusion range of standing operators; configurable with manual reset + EDM monitoring to meet machine tool safety standards.
Répartition du code modèle
Modèle: F3SG-4RE1630P30
| Segment | Code | Définition |
| F3SG | Série | F3SG-R Basic Safety Light Curtain (Entry-level model; no muting, no cascade function) |
| 4 | Type de sécurité | Taper 4 highest safety rating, PL e / SIL 3 / Catégorie 4 |
| RE | Sous-série | RE = Basic simplified version; no muting, no cascade, no beam coding, only basic safety outputs |
| 1630 | Protected Height | Effective protective height: 1630 mm |
| P. | Type de sortie | Dual PNP OSSD safety outputs |
| 30 | Résolution | 30mm hand protection, beam pitch 20mm, minimum detectable opaque object: φ30mm |
- Core Electrical & Safety Specifications
2.1 Mandatory Safety Certifications
CEI 61496-1: Taper 4
OIN 13849-1: PL e / Catégorie 4
CEI 61508: SIL 3
Conforme à la norme EN 60204-1, Catégorie 0 machine safety stop
2.2 Optical Detection Parameters
Protected Height: 1630 mm
Beam Pitch: 20 mm
Total Beams: 80 beams
Minimum Detectable Opaque Object: φ30 mm (hand protection grade)
Detection Range: 0.3 m~ 20 m
Maximum Response Time: 9 MS
Synchronization: Optical synchronization, no dedicated sync wiring required
2.3 Paramètres électriques
Tension d'alimentation: 24 VDC ±20% (SELV Safety Extra Low Voltage)
Safety Outputs: 2-channel PNP OSSD, max load per channel: 300 mA
Residual Voltage: ≤2 V
Courant de fuite: ≤1 mA
Transmitter Current Draw: ≤120 mA; Receiver Current Draw: ≤150 mA
Connecteur: M12 straight plug; Émetteur: 5-épingle, Récepteur: 8-épingle, factory fitted with 0.3m short cable
2.4 Environnemental & Mechanical Properties
Dimension globale: 35(W) × 35(H) × 1630(L) mm
Protection contre la pénétration: IP67 (when connectors fully tightened)
Température de fonctionnement: -10 ℃ ~ +55 ℃
Température de stockage: -25 ℃ ~ +70 ℃
Humidité: 35%~85% RH, sans condensation
Résistance aux vibrations: 10~55Hz, amplitude 0.7mm, 20 cycles per 3 axes
Résistance aux chocs: 100 m/s², 1000 shocks per 3 axes
Matériau du boîtier: PBT engineering plastic; Optical window: PC polycarbonate
Poids net (Émetteur + Receiver Set): ~1.2 kg
- Description de la fonction (Limitations of RE Basic Series)
✅ Standard Built-in Functions
- Two independent OSSD safety outputs; outputs cut off immediately upon beam occlusion
- Commutateur DIP sélectionnable: Auto-reset / Manual-reset, EDM external device monitoring enable/disable
- Rouge & Green LED status indicators (Pouvoir, Sync, Occlusion, Faute)
- Long-distance mode optimized for detection range 10~20 m
❌ Unsupported Functions (Not available on RE basic model)
Muting function
Multi-unit cascade connection
Anti-interference beam coding
Auxiliary signal output (only dual safety outputs available)
- M12 Connector Pin Definition
Émetteur (5-pin M12)
1: 24V DC+
2: 0V GND
3: Optical Sync
4: Inutilisé
5: Bouclier
Récepteur (8-pin M12)
1: 24V DC+
2: 0V GND
3: OSSD1 PNP Output
4: OSSD2 PNP Output
5: EDM Monitoring Input
6: Reset Input
7: Optical Sync
8: Bouclier
- Scénarios d'application typiques
- Perimeter safety protection for industrial robot workcells
- Hand protection for stamping & injection molding machine operating zones
- Safety isolation at inlet/outlet of automated conveyor lines
- Human intrusion detection for large machine tools & assembly lines with 1.6m protective height
- Safety light curtain for AGV traffic aisles in warehouses
- Optional Matching Accessories (Ordered Separately)
- F39-JD□RA: M12 extension cables (5m/10m/20m)
- F39-BT Standard Mounting Bracket, F39-BTLP Long Bracket
- F39-SG Splash Guard (for environments with cutting fluid & forte poussière)
- F39-LZ Laser Alignment Tool (fast calibration for long-distance installation)
- Alternative Replacement Models
- Direct drop-in equivalent (mêmes spécifications): F3SG-4RE1630N30 (NPN output version)
- Upgraded SR series (long-term supply recommended): F3SG-4SR1630-25 (Taper 4, fonctions améliorées, supports muting & cascade)
- Lower safety Type 2: F3SG-2RE1630P30 (PLd, not applicable for high-risk pressing machinery)
- Installation & Directives de mise en service
- Minimum mounting distance between light curtain and hazard zone ≥0.3m; calculate safety distance matching machine braking time
- Optical alignment after installation: steady green LED = normal operation; flashing LEDs indicate misalignment or out-of-range distance
- EDM external monitoring must be enabled for high-risk equipment to detect safety relay contact welding faults
- Reset mode configuration: Manual reset mandatory for presses/stamping machines; auto-reset allowed for conveyor lines
- Avoid direct intense light irradiation on optical windows to prevent infrared interference and false triggering
- Matrice de dépannage rapide
| Phénomène de défaut | Cause première | Solution |
| Steady red LED, no safety output | Beam occlusion, misaligned transmitter/receiver, câble cassé | Clean optical window, realign light curtain, inspect M12 connectors |
| Alternating red & green flashing | Distance out of 0.3~20m range, strong light interference | Shorten installation distance, install light shield, activate long-distance DIP switch |
| Locked state after power-up, cannot reset | Open EDM circuit, incorrect DIP switch settings | Check feedback wiring of safety relay, reset DIP switches |
| Safety outputs fail to cut off load | Courant de charge excessif, inductive load without freewheeling diode | Reduce load current, install freewheeling diode parallel to inductive loads |
Moulage par injection & Die Casting Equipment
- Open pick-up ports replacing safety doors for vertical & horizontal injection molding machines
- Feeding & part extraction windows for aluminum & zinc alloy die-casting machines
- Operating station isolation for rubber vulcanizers & extrudeuses
Application: Manual loading/unloading of mold products, preventing hands entering clamping & extrusion hazard zones.
- Industrie de l'usinage
- Open loading/unloading channels for CNC milling machines & centres d'usinage
- Manual feed side protection for lathes, broyeurs & band saws
- Manual loading stations for sheet metal & fiber laser cutters
Avantages: IP67 dust & liquid resistance, tolerates cutting fluid and metal dust; 30mm resolution prevents finger intrusion into cutting tool hazard zones.
- Industrial Robot Workcells
- Access gates of 6-axis robot handling & assembly safety fences
- Manual intervention channels for palletizing & welding robots
- Safety passages for robot grinding & coating stations
Description: 1.63m height fits adult standing passage; power cut-off for robots upon personnel intrusion, complies with PL e machinery safety requirements.
- Automated Conveying & Packaging Lines
- Inlet & outlet protection for carton sealers & machines d'emballage
- Hazard zone isolation for stretch wrapping & pallet strapping machines
- Separation stations of production lines & manual sorting workstations
- Dual-side safety light curtains for AGV & forklift traffic aisles
Working Condition: Auto-reset configurable for assembly lines; machine stops upon accidental intrusion and resumes automatically after personnel leave.
- Lithium Battery & 3C Electronic Automation Equipment
- Manual operation windows for battery slitting & winding machines
- Feed inlets of phone housing CNC & équipement de pressage
- Open stations for battery testing & assembly machines
Avantages: 24V SELV low voltage eliminates electric leakage risk; low electromagnetic interference compatible with precision electronics production lines.
- Warehouse & Logistics Lifting Equipment
- Side safety protection for small freight elevators & lifts
- Manual access openings of automated racking systems
- Hazard gap isolation for roller conveyors & transfer machines
- Wood & Stone Processing Machinery
- Feed inlet protection for sliding table saws, sanders & stone cutting machines
- Operating zone isolation for wood door & panel polishing equipment
Scénarios d'application inappropriés (Limitations of RE Series)
- Processes requiring material passing through protective area (Muting function unavailable; machine stops when any workpiece passes, F3SG-SR series recommended instead)
- Multi-curtain splicing via cascade connection (RE series does not support cascade)
- Long-term vehicle & large workpiece access passages (Muting function mandatory to avoid frequent unexpected shutdowns)
Response Time Parameters of OMRON F3SG-4RE1630P30
- Maximum Response Time: 9 MS
- Supplementary Explanation:
This value refers to total full response duration for the complete set (transmitter + receiver) to cut off OSSD safety outputs
This model has 1630mm protective height with a large number of beams, representing the upper response time limit within the same RE series
The maximum value of 9ms must be adopted for safety distance calculation, typical values cannot be used
Total system stop reaction time after pairing with safety relay = 9ms (curtain) + safety relay actuation time
Model Selection Tips
If ultra-fast braking speed is required, select shorter protective height models from the same RE series; fewer beams deliver faster response speed.