Modèle complet: NBB20-L2-A2-V1
Catégorie de produit: Square Inductive Capteur de proximité (VariKont L Series)
Spécifications de base
| Article | Paramètre |
| Numéro de commande. | 187548 |
| Distance de détection nominale Sn | 20 mm, Flush Mountable |
| Type de sortie | 4-fil CC, PNP Complementary Output (NON+NC) |
| Tension d'alimentation | 10 … 30 À DC |
| Connexion | M12 4-pin Male Connector |
| Fréquence de commutation | 440 Hz |
| Protection contre la pénétration | IP68 / IP69K |
| Matériau du boîtier | Pennsylvanie (Polyamide / Nylon) |
| Dimension globale | 40 × 40 × 67 mm |
| Température de fonctionnement | -25 ℃ ~ +85 ℃ |
| Caractéristiques | Rotatable sensing head; 4 LEDs for 360° status visibility; Quick-mount bracket included |
Affectation des broches (M12 4 broches)
- BN Brun: +VCC
- WH White: NC normalement fermé
- Bleu BU: 0V/GND
- BK Noir: NON Normalement Ouvert
Caractéristiques & Applications
Square housing with long sensing distance, flush mount design for metal target detection
Built-in reverse polarity protection and short-circuit protection; adapté aux machines-outils, lignes de convoyeurs, workpiece counting and position detection
Sensing distance derating for non-ferrous metals: Aluminium 0.33, Cuivre 0.31
Référence de remplacement
Compare with same series: NBB20-L2-E2-V1 (NPN version); Version câble: NBB20-L2-A2
Type de produit: Square Inductive Proximity Sensor, Numéro de commande. 187548
- Présentation du produit
Modèle: NBB20-L2-A2-V1, Numéro de commande: 187548
Distance de détection: Sn=20 mm, Flush Mountable
Sortir: 4-fil CC, PNP complementary (NON + Caroline du Nord)
Sensing Head: Rotatable, 4 LEDs for 360° visual status indication
Included Accessories: Quick-mount bracket
Indice de protection: IP68 / IP69K, PA nylon housing
- Installation Requirements【Important】
- Flush Mount Definition: The sensing face must be level with the metal mounting surface; surrounding metal must not protrude above the sensing face. This model is designed for flush mounting only, do not install as non-flush.
- Minimum Spacing Between Sensors
Side-by-side installation of identical sensors: Centre distance ≥ 40 mm
Face-to-face installation: Distance ≥ 60 mm to prevent mutual interference
- Metal Clearance Requirements
Rear metal backplate: Thickness ≥1 mm, extending at least 10 mm beyond the sensor outline
Side metal adjacent to sensing face: Minimum clearance ≥10 mm; nearby metal will reduce sensing range and cause false triggering
- Target Specs: Standard test target: 40×40×1 mm mild steel. Effective sensing distance for aluminium, copper and 304 stainless steel needs to be multiplied by derating factor
Aluminium Al: 0.33
Copper Cu: 0.31
304 Acier inoxydable: 0.74
- Support de montage: Use original quick-mount bracket. Recommended tightening torque for mounting screws: 0.8 ~ 1.2 N·m. Do not over-tighten to avoid cracking PA housing.
- Sensing Head Adjustment: Loosen the head fixing screw to rotate the sensing face, retighten after alignment; do not force rotation.
- Dimension (40×40 Square Housing)
Taille globale: 40 mm (W) × 40 mm (H) × 67 mm (L)
Visage de détection: 40×40 mm square
Connecteur: M12×1 4-pin male
Poids: Environ. 155 g
- Définition du câblage (EN60947-5-2)
| Numéro de broche. | Colour | Définition |
| 1 | BN Brun | CC + 10~30V |
| 2 | WH White | NC normalement fermé (PNP) |
| 3 | Bleu BU | 0V / GND |
| 4 | BK Noir | NON Normalement Ouvert (PNP) |
Note: Sortie PNP; load is connected between signal wire and 0V. Built-in reverse polarity protection and pulsed short-circuit protection. Max output current per channel: 200 mA.
- Indications LED
Power LED: Steady ON = Power supply OK; Éteint = Pas d'alimentation / Polarité inversée
Switch LED: Metal target enters reliable sensing range (0~16.2 mm) → output state toggles, corresponding LED illuminates
4-side LED design, status visible from any angle
Usable operating range Sa: 0 ~ 16.2 mm (guaranteed stable switching range); Sr typical switching range 18~22 mm
- Electrical Installation Guidelines
- Alimentation: CC 10 ~ 30 V, regulated DC supply recommended, ondulation <10%
- Câbles: Shielded or unshielded cables for M12 connection; use shielded cable for cable length >10 m, single-end grounding for shield
- Acheminement des câbles: Separate from power cables (onduleur, motor cables) to avoid strong electromagnetic interference
- Fréquence de commutation: 440 Hz, do not exceed this limit for high-speed counting applications
- Hystérèse: Typically ~5% of rated sensing distance, prevents chattering caused by minor target vibration
- Mécanique & Spécifications environnementales
Température de fonctionnement: -25 ℃ ~ +85 ℃
Température de stockage: -40 ℃ ~ +85 ℃
IP68/IP69K: High-pressure washdown compatible; ensure connector fully locked and seal intact
Interdit: Impact on sensing face, welding near sensor, long-term use in strong acid/alkali environments
- Procédure de mise en service
- Secure sensor with mounting bracket and adjust sensing face orientation
- Mate M12 connector, verify wiring sequence and power on
- Slowly move standard metal target towards the sensing face
- Confirm reliable output switching and LED activation within 0~16.2 mm
- Lock target trigger position and repeat multiple tests; no chattering = acceptable
- Dépannage
| Symptôme | Vérifier les éléments |
| No LED after power on | Tension d'alimentation, polarité, loose pins in M12 connector |
| Aucun signal de détection | Metal target derating factor, adjacent metal interference, out of Sa reliable range |
| Signal flickering | EMI from power cables, montage lâche, thin target, ondulation de l'offre élevée |
| Output cannot reset | Court-circuit, leakage load, signal wire shorted to 24V |
- Notes de sécurité
This sensor is NOT a safety-rated sensor, must not be used in safety circuits (Arrêt d'urgence, barrière de sécurité)
Isolate power before maintenance; avoid frequent hot-plugging of M12 connector (hot swapping may damage contacts)
UL approval: Classe 2 circuit supply, max 60VDC, 200charge en mA
Pepperl+Fuchs Square Inductive Proximity Sensor List (VariKont L2 / U / Série F)
Note: Series includes VariKont L2 (40×40, the series of 187548), VariKont U and compact F series. Sn = Rated sensing distance. F=Flush, NF=Non-flush. E2=PNP NO, E0=NPN NO, A2=PNP complementary NO+NC, A0=NPN complementary NO+NC. V1=M12 connector; no V suffix = fixed cable.
- VariKont L2 40×40 (Grand public, Rotatable Sensing Head, IP68/IP69K)
| Modèle | Numéro de commande. | Sn | Monter | Sortir | Connexion |
| NBB20-L2-A2-V1 | 187548 | 20 mm | Flush F | PNP 4-wire Complementary NO+NC | M12 4-pin Male |
| NBB20-L2-E2-V1 | 187549 | 20 mm | Flush F | PNP 3-wire NO | M12 3-pin Male |
| NBB20-L2-A0-V1 | 187550 | 20 mm | Flush F | NPN 4-wire Complementary NO+NC | M12 4-pin Male |
| NBB20-L2-E0-V1 | 187551 | 20 mm | Flush F | NPN 3-wire NO | M12 3-pin Male |
| NBN40-L2-A2-V1 | 187552 | 40 mm | Non-flush NF | PNP 4-wire Complementary NO+NC | M12 4-pin Male |
| NBN40-L2-E2-V1 | 187553 | 40 mm | Non-flush NF | PNP 3-wire NO | M12 3-pin Male |
| NBN40-L2-A0-V1 | 187554 | 40 mm | Non-flush NF | NPN 4-wire Complementary NO+NC | M12 4-pin Male |
| NBN40-L2-E0-V1 | 187555 | 40 mm | Non-flush NF | NPN 3-wire NO | M12 3-pin Male |
| NBN40-L2M-E2-V1 | 132360 | 40 mm | Non-flush NF | PNP 3-wire NO | M12 3-pin Male |
- VariKont U 40×40 (Older Version, Terminal / Type de câble)
| Modèle | Numéro de commande. | Sn | Monter | Sortir | Connexion |
| NBB20-U1-A2 | 87231 | 20 mm | Flush F | PNP 4-wire Complementary | 2m Fixed Cable |
| NBB20-U1-E2 | 87232 | 20 mm | Flush F | PNP 3-wire NO | 2m Fixed Cable |
| NBB20-U2-A2 | 87233 | 20 mm | Flush F | PNP 4-wire Complementary | Bornier |
| NBB20-U4-UU | 248043 | 20 mm | Flush F | AC/DC 2-wire | 陆NPT |
| NBN40-U1-E2 | 87234 | 40 mm | Non-flush NF | PNP 3-wire NO | 2m Fixed Cable |
| NBN40-U4K-N0-V1 | 103753 | 40 mm | Non-flush NF | Namur | Connecteur M12 |
| NBB15-U1-A2 | 124008 | 15 mm | Flush F | PNP 4-wire Complementary | Câble |
- Compact F Series (F1/F10/F11/F33/F41/F79)
| Modèle | Numéro de commande. | Sn | Monter | Sortir | Connexion |
| NBN8-F1-E2 | 84012 | 8 mm | Non-flush NF | PNP NON | 2m Câble |
| NBN8-F1-A2-V31 | 84014 | 8 mm | Non-flush NF | PNP Complementary | Connecteur M8 |
| NBB1,5-F41-E2 | 84001 | 1.5 mm | Flush F | PNP NON | 2m Câble |
| NBB1,5-F41-E2-V3 | 84002 | 1.5 mm | Flush F | PNP NON | Connecteur M8 |
| NBB4-F10-E2 | 84005 | 4 mm | Flush F | PNP NON | 2m Câble |
| NBB5-F11-E2 | 84008 | 5 mm | Flush F | PNP NON | 2m Câble |
| NBB3-F33-E2 | 84018 | 3 mm | Flush F | PNP NON | 2m Câble |
| NBB0,8-F79-E2 | 84022 | 0.8 mm | Flush F | PNP NON | Câble |
- FP Large Square Series (55×55, Long Sensing Range)
| Modèle | Numéro de commande. | Sn | Monter | Sortir | Connexion |
| NBB50-FP-E2 | 87240 | 50 mm | Flush F | PNP NON | Câble / Terminal |
| NBN80-FP-E2 | 87241 | 80 mm | Non-flush NF | PNP NON | Câble / Terminal |
Règle de dénomination du modèle
- BNB: Blindé (Flush mountable); NBN: Non blindé (Non-flush only)
- Nombre: Distance de détection nominale Sn (mm)
- L2 = New 40×40 L2 series with rotatable head; U = Older VariKont U; F = Compact F housing; FP = Large square FP housing
- A2: PNP 4-wire complementary (NON+NC); A0: NPN 4-wire complementary; E2: PNP 3-wire NO; E0: NPN 3-wire NO; E1: Caroline du Nord
- V1: Connecteur M12; V3: Connecteur M8; No suffix = Fixed PVC cable; UU = AC/DC 2-wire; K = NAMUR Intrinsically Safe
Notes complémentaires
This list covers mainstream standard stock models, excluding high-temperature, antidéflagrant, custom IO-Link variants
Different suffixes correspond to unique order numbers and cannot be interchanged
Standard derating reference: Aluminium ≈0.33, Copper ≈0.31, 304 Stainless Steel ≈0.74
Working Principle of Inductive Proximity Sensor
Pepperl+Fuchs inductive proximity sensors operate on the eddy current effect. They detect metal targets only and cannot sense plastic, bois, water or glass.
Principaux composants internes
- LC Oscillator Circuit (Bobine + Condensateur): Generates high-frequency alternating magnetic field (typically hundreds of kHz)
- Sensing Coil: Emits alternating magnetic field from the sensing face
- Signal Processing Circuit: Amplitude detection, comparison and signal conditioning
- Output Driver Stage: PNP / NPN / NAMUR etc.
Séquence de travail
- Après la mise sous tension, the LC oscillator starts oscillating, and the coil emits high-frequency alternating magnetic field
- Pas de métal à proximité: Low magnetic energy loss, oscillation is maintained, output stays in original state
- Metal target enters magnetic field: Alternating field penetrates the metal surface and induces eddy currents inside the metal
- Eddy currents generate opposing magnetic field, counteracting the original field and consuming oscillation energy, resulting in reduced oscillation amplitude or oscillation halt
- Post-processing circuit detects amplitude change, triggers hysteresis comparison and toggles output state (NO/NC on or off)
- Metal moves away → eddy current disappears → oscillation recovers → output resets
Résumé: Inductive sensors detect metal presence by measuring energy loss caused by eddy currents induced in metal within an alternating magnetic field.
Key Feature Explanation (Matching Pepperl+Fuchs Square Sensors)
BNB (Blindé / Flush Mountable): Shield ring around the coil concentrates magnetic field forward with minimal side emission. Can be embedded into metal mounting plate without false triggering
NBN (Non blindé / Non affleurant): No shielding ring, magnetic field radiates outward in all directions. Cannot be embedded into metal, otherwise it will continuously detect the mounting metal and false trigger
Sensing Distance Derating: Eddy current strength varies with metal conductivity. Detection capability: Steel Stainless Steel Aluminium Copper, so effective range decreases for aluminium and copper
Hystérèse: Difference between switch-on distance and switch-off distance. Eliminates output chattering caused by minor target vibration
Détection de métaux uniquement: Non-metallic materials do not generate eddy current and will not trigger the sensor
Comparaison rapide
Inductif: Metal-only, eddy current principle
Capacitif: Detect metal, plastique, liquide, based on electric field change
Photo-électrique: Operate via light emission/reception, mostly unaffected by material (except opaque/transparent objects)