Numéro de commande: 2708863, PROFIBUS DP Modular Isolated Bus Repeater Model Definition PSI: Process Signal Interface series REP: Repeater PROFIBUS: Bus type PROFIBUS DP 12MB: Max communication rate 12 Mbps Key Specifications Item Parameter Order No. 2708863 Product Name PSI-REP-PROFIBUS/12MB Bus Protocol PROFIBUS DP (RS485, IEC61158) Communication Speed 9.6k ~ 12Mbps, DIP switch for manual or ...

  • Détails du produit

Numéro de commande: 2708863, PROFIBUS DP Modular Isolated Bus Repeater

  1. Définition du modèle

PSI: Process Signal Interface series

REP: Repeater

PROFIBUS: Bus type PROFIBUS DP

12Mo: Max communication rate 12 Mbit/s

  1. Spécifications clés
ArticleParamètre
Numéro de commande.2708863
Nom du produitPSI-REP-PROFIBUS/12MB
Protocole de busPROFIBUS-DP (RS485, IEC61158)
Communication Speed9.6k ~ 12Mbps, DIP switch for manual or auto baud rate detection
AlimentationDC 18~30V (nominal 24 V CC)
Isolement4-way galvanic isolation (Alimentation, Segment A bus, Segment B bus, fond de panier)
MontageMontage sur rail DIN 35 mm
Température de fonctionnement-20℃ ~ +60℃
TopologieDoubler, étoile, tree; supports cascading for bus extension
FonctionsBit retiming, faulty message filtering, switchable bus termination resistor
CertificationsCE, UL, cULus, ATEX, CAE, KC
Matériau du boîtierPA6.6-FR, grey RAL7042
  1. Product Functions
  2. Bus Extension: Extend PROFIBUS cable length; repeater recovers signal waveform, multi-stage cascading supported.
  3. Galvanic Isolation: 4-segment isolation eliminates ground loop interference, segregates networks at different potential levels for enhanced EMC performance.
  4. Signal Shaping: Bit sampling + bit retiming to suppress jitter and filter corrupted interference packets.
  5. Modular Backplane Bus: Integrated DIN rail backplane allows direct combination with PSI-MOS fiber converters to build hybrid PROFIBUS copper/fiber networks.
  6. Active termination resistor, redundant power supply supported.
  7. Scénarios d'application typiques

Segmental isolation for large-scale factory PROFIBUS DP networks

Networking of devices with differing ground potentials (convertisseurs de fréquence, moteurs, field instruments)

Long-distance PROFIBUS wiring and compensation for bus signal attenuation

PROFIBUS bus isolation in hazardous areas (Certification ATEX)

Retrofit and expansion of PROFIBUS legacy systems in steel, papier, water treatment and automotive production lines

  1. Sélection du modèle & Alternatives

✅ Identical replacement: 2708863 (PSI-REP-PROFIBUS/12MB), original unique part number

No fully pin-to-pin domestic alternative from Phénix Contact.

Alternative similar PROFIBUS repeaters: Siemens PROFIBUS repeater, Weidmüller PROFIBUS isolated repeater (fonctions similaires, but limited modular backplane capability and incompatible with PSI-MOS optical modules).

  1. Installation & Directives d'entretien
  2. Do not reverse PROFIBUS A/B wiring on the two bus ports.
  3. Bus termination resistors: enable only at the physical endpoints of each segment; disable for intermediate nodes.
  4. Commutateur DIP: auto baud rate mode suitable for most field applications; fixed baud rate for high-speed stable operation.
  5. 24VDC isolated power supply recommended to reduce common-mode interference.
  6. Dépannage: read module LEDs to identify power failure, Segment A bus fault or Segment B bus fault.
  7. Bus de fond de panier: Phoenix dedicated backplane connectors required when combining with PSI-MOS fiber converters.
  8. HS Code Reference (Foreign Trade)

85176290 (Other digital repeaters, équipement de communication). Final customs classification subject to local customs authority.

  1. Second-Hand Inspection Checklist
  2. Power on and verify power indicator.
  3. Connect Segment A and B separately to master/slave devices and test 12Mbps communication.
  4. Measure isolation resistance to confirm intact 4-way isolation without breakdown.
  5. Validate DIP switch functions.
  6. Inspect housing for burn marks and terminal blocks for oxidation.

PHOENIX 2708863|PSI-REP-PROFIBUS/12MB Application Scenarios

Positionnement de base: PROFIBUS DP Modular Isolated Repeater. Core benefits: bus segment isolation, signal reshaping & regeneration, breaking the 32-node limit per electrical segment, hybrid networking with PSI-MOS fiber modules, max 12Mbps high-speed communication, Zone ATEX 2 hazardous area certification.

  1. General Network Use Cases
  2. Bus Distance Extension

PROFIBUS twisted pair has limited transmission distance at 12Mbps. A repeater regenerates signal waveform and extends the bus by segmentation; multi-stage cascading is available.

Principe: Each independent segment achieves maximum cable length corresponding to its baud rate, solving signal attenuation and inter-symbol jitter over long cables.

  1. Node Quantity Expansion

PROFIBUS standard limits max 32 devices per electrical segment. The repeater creates isolated new segments, total nodes = n×32 (n = number of segmens). Preferred solution for legacy projects adding inverters, remote I/O and DP instruments when node capacity is exhausted.

  1. Ground Potential Difference Isolation (Application la plus courante)

Different workshops, high/low voltage cabinets and motor fields may have ground loop voltage ranging from tens to hundreds of volts, which causes intermittent DP communication dropout or burns DP transceiver chips.

The module features 4-way isolation (Pouvoir / Segment A / Segment B / Fond de panier) to cut ground loops and protect PLC and field instruments.

  1. Segmented Fault Isolation to Improve System Availability

Split one long bus into multiple isolated segments. Court-circuit, cable break or heavy interference on one segment will not propagate to the whole network. Only the faulty segment stops operation; the rest of the network remains online for easy fault localization.

  1. Topology Modification: Convert Linear Bus to Star/Tree Branches

Native PROFIBUS only supports linear topology. This repeater creates independent DP branch segments to implement star topology for distributed device clusters. Each branch operates independently without interference from the main trunk.

  1. Hybrid Copper-Fiber Bus Networking (Unique Advantage of This Model)

Combined with Phoenix PSI-MOS PROFIBUS fiber converters via DIN rail backplane connectors, a modular station can be built to form hybrid PROFIBUS copper + fiber networks for long-distance cross-area deployment and high-EMI environments using optical transmission.

  1. Applications spécifiques à l'industrie

✅ Automotive Welding & Assembly Lines

Large quantities of DP servos, convertisseurs de fréquence, robots and distributed I/O; high ground potential differences and strong EMI from welding machines.

Avantages: segment isolation, DP bus protection, node expansion, supporting 12Mbps high-speed motion control communication.

✅ Steel, Métallurgie & Rolling Lines

Haute température, large motors and high-power drives with severe EMI and differing rack ground potentials.

Avantages: isolate segments at different potentials, prevent ground loop damage to DP interfaces, extend bus across rolling mill areas.

✅ Water Treatment, Usines de traitement des eaux usées & Pump Stations

Widely distributed DP pressure/level transmitters and valves over large plant footprints with long cable runs.

Avantages: bus extension and segmentation; suppress interference from high-power pumps; legacy system retrofit and expansion.

✅ Chemical & Pharmaceutical Plants (Zone ATEX 2)

Module carries ATEX certification for PROFIBUS networks in Zone 2 zones dangereuses.

Used for bus isolation between hazardous field areas and non-hazardous control cabinets, and segmented protection for field instrument segments.

✅ Paper & Textile Production Lines

Multiple DP frequency converter clusters for continuous production lines where full-line shutdown is unacceptable.

Segmentation ensures local faults do not stop the whole production line and accelerates fault location.

✅ Power Plants, Ciment & Mining DCS/PLC Systems

Wide plant layout with high-power equipment and ground potential drift; DP bus connects remote I/O and fieldbus instruments.

  1. Frequent Retrofit Scenarios
  2. Legacy PROFIBUS System Expansion: Original DP segment reaches 32-node limit. Add repeaters to create new segments without PLC master replacement.
  3. Troubleshooting Unstable Communication: Frequent intermittent dropout caused by ground loop interference; install isolated repeaters.
  4. Speed Upgrade: Original long cable limited operation to 1.5Mbps. Segmentation allows upgrade to 12Mbps high-speed DP.
  5. Inter-cabinet Networking: Communication between separate control cabinets with potential differences, isolated via repeaters.
  6. Scénarios non applicables

No protocol conversion. Physical-layer PROFIBUS DP repeater only, cannot convert to Profinet or Modbus.

Zone 2 certified only, not suitable for Zone 0 / Zone 1 intrinsically safe hazardous areas.

Protection IP20, pour montage en armoire uniquement; not for direct outdoor field installation.

  1. Supporting Selection Tips

Backplane combination: use PSI-MOS-PROFIB/FO series optical modules for long-distance fiber transmission.

Redondance: module supports dual 24VDC redundant power supply; recommended for critical production lines.

Topology notes: each segment must be terminated independently. The repeater’s two ports belong to two separate bus segments.

Working Principle of PROFIBUS DP Modular Isolated Repeater (PSI-REP-PROFIBUS/12MB, 2708863)

Core nature: RS485 physical-layer signal regeneration + galvanic isolation + bit retiming. No parsing of DP application-layer protocols, only electrical signal processing. It is a physical-layer device, NOT a gateway or protocol converter.

  1. Fundamental Principle Breakdown

PROFIBUS DP is based on RS485 differential bus. Long cables, high node count and ground potential differences introduce three major issues: atténuation du signal, signal jitter (phase drift) and common-mode ground loop interference.

The repeater divides the bus into two electrically independent segments (Side A, Side B) and executes three core operations:

  1. Reception: Read differential A/B signals from Segment A.
  2. Signal Shaping & Bit Retiming: Recover clean square-wave clock and eliminate transmission-induced jitter and distortion.
  3. Driven Forwarding: Send newly regenerated differential signals to Segment B with fresh driver levels.

⚠️ Only valid DP bit streams are forwarded; corrupted spike/interference packets are filtered out.

1.1 Signal Regeneration (Bit Retiming, Key Feature of This Model)

Low-cost generic RS485 repeaters merely amplify signals without clock recovery, so jitter accumulates and communication remains unstable after multi-stage cascading.

This Phoenix model is an active repeater with retiming:

Internal PLL locks onto and synchronizes with incoming data stream.

Extracts bit clock and reconstructs standard square waveform.

Outputs new differential signals with clean edges.

Avantage: Supports multi-stage cascading without cumulative jitter, enabling 12Mbps high-speed DP operation.

1.2 4-Way Galvanic Isolation (Core Anti-Interference Feature)

Modèle 2708863: Isolation between power supply, Segment A bus, Segment B bus and backplane bus.

Isolation components: high-speed digital isolators (not low-speed conventional optocouplers), rated for 12Mbps bandwidth.

Fonction: cut off ground loop current between Segment A and Segment B.

In field sites, potential differences of tens to hundreds of volts may exist between devices/cabinets. Ground loop current creates common-mode interference on DP shield and signal lines, leading to intermittent communication or permanent damage to RS485 transceivers. After isolation, Segment A and Segment B have independent reference grounds; potential differences cannot cross segments.

1.3 Segment & Fault Isolation

Court-circuit, cable break or severe interference on Segment A → repeater detects anomaly and prevents faulty/short-circuit signals from propagating to Segment B.

Fault is confined to one segment; rest of DP network remains operational for segmented troubleshooting.

1.4 Baud Rate Recognition via DIP Switches

Auto mode: automatically detects DP baud rate on power-up (9.6k ~12Mbps) and synchronizes.

Fixed mode: baud rate locked via DIP switch for high-speed stable production lines to avoid misdetection.

1.5 Modular Backplane Bus (Unique to PSI Series)

Modules communicate via built-in backplane connectors on DIN rail.

This repeater can be directly assembled with PSI-MOS PROFIBUS fiber transceivers on the same rail without extra wiring to realize PROFIBUS electrical ↔ optical conversion, building hybrid copper/fiber bus networks.

  1. Signal Flow Diagram

DP Segment A (Maître / E/S / Convertisseur de fréquence)

↓ (Differential A/B signals)

【Isolated Side A Receiver Circuit】

PLL bit clock reconstruction + corrupted packet filtering

【Isolated Side B Driver Circuit】

DP Segment B (Independent segment, maximum 32 nœuds)

  1. Critical Boundary Notes (Pièges courants)
  2. Physical-layer device only, no PROFIBUS protocol parsing

Does not interpret DP telegrams, perform address forwarding or protocol conversion. Cannot convert to Profinet / Modbus. Only forwards raw binary bit streams.

  1. Port A and Port B belong to two fully independent bus segments

Termination resistors must be configured separately for each segment!

✅ Enable termination only at the physical endpoints of each segment

✅ Repeater ports act as segment start points. Termination on repeater ports is disabled by default (unless that port is the physical end of its segment).

  1. Node count limit: maximum 32 DP nodes per segment (the repeater itself is not a DP slave and does NOT count towards the 32-node limit).
  2. Cascading: multi-stage cascading supported, but total latency must stay within PROFIBUS DP timing budget.
  3. Comparison with Generic RS485 Repeaters
ArticleGeneric RS485 RepeaterPSI-REP-PROFIBUS/12MB (2708863)
Clock HandlingSimple signal amplification, no bit retimingPLL bit retiming, waveform reconstruction
Vitesse maximaleMany limited to 1.5MbpsUp to 12Mbps
IsolementSome have only single isolation4-way independent isolation (Pouvoir / UN / B / Fond de panier)
Fault ContainmentFaults easily pass through to opposite sideSegment isolation, blocks fault propagation
ExpansionNo backplane, incompatible with optical modulesDIN rail backplane, directly compatible with PSI-MOS optical modules
  1. Typical Operational Example

PLC master transmits DP telegram on Segment A → repeater Side A receives differential signals, galvanic isolation applied, PLL reconstructs clean bit stream and filters glitches → isolated Side B driver outputs regenerated differential signals → inverters and remote I/O on Segment B receive the telegram. Bidirectional half-duplex communication works in reverse direction identically.

Précédent: