Contact Phénix 2986575 Safety Coupling Relay - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Contact Phénix 2986575 Safety Coupling Relay - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

Contact Phénix 2986575 Safety Coupling Relay

Contact Phénix 2986575 (PSR-SCP-24DC/FSP2/2X1/1X2) Safety Coupling Relay SIL 2 certified safety coupling relay, 24V DC power supply, 2 normalement ouvert + 1 contacts normalement fermés, integrated FSP2 test pulse filter, 17.5mm narrow-width DIN rail mounting. Suitable for safety shutdown applications. Numéro de commande. 2986575. Model Segment Definition Model Segment Description PSR Product series: Phoenix Contact classic ...

  • Détails du produit

Contact Phénix 2986575 (PSR-SCP-24DC/FSP2/2X1/1X2) Safety Coupling Relay

SIL 2 certified safety coupling relay, 24V DC power supply, 2 normalement ouvert + 1 contacts normalement fermés, integrated FSP2 test pulse filter, 17.5mm narrow-width DIN rail mounting. Suitable for safety shutdown applications. Numéro de commande. 2986575.

  1. Définition du segment du modèle
Segment de modèleDescription
PSRSérie de produits: Phoenix Contact classic safety relay series (PSRclassic)
SCPType de produit: Safety Coupling Relay
24CCOperating voltage: 24À DC
FSP2Code de fonction: Filter for Test Pulses Version 2, compatible with SIL 2 candidatures
2X1Safety contact configuration: 2 normalement ouvert (NON) enable current paths
1X2Configuration des contacts auxiliaires: 1 normalement fermé (Caroline du Nord) signal/alarm contact
2986575Phoenix Contact official order number, globally unique identifier
  1. Full Version Core Specification Table
Catégorie de paramètreSpecific ParameterRemarques
Basic InfoSafety coupling relay, SIL 2 certified, Cat. 1, Indice de protection IP20Compliant with EN 61508
Numéro de commande.2986575Order strictly by this part number
DimensionsW17.5mm × H99mm × D114.5mmMontage sur rail DIN, saves cabinet space
Tension de fonctionnement24À DC, plage autorisée: 19.2V~28.8V DCRipple ≤10%
Paramètres de la bobineResistance 436.36Ω, current approx. 55mAPower consumption approx. 1.32W
Configuration des contacts2 NO enable paths + 1 NC alarm contactForced guided contacts, conforme à la norme EN 50205
Contacter l'évaluation5A @ 250V AC / 30À DCAgCuNi contact material, longue durée de vie
Caractéristiques de sécuritéIntegrated test pulse filter, prevents false triggering by controller self-test pulsesApplied to safety shutdown scenarios
Type de connexionPlug-in screw terminal, wire size 0.2mm²~2.5mm²Easy quick replacement & entretien, reliable wiring
Conditions ambiantesTempérature de fonctionnement: -25°C ~ +55°C; Storage temp: -40°C ~ +85°C; Relative humidity ≤95% (sans condensation)Industrial standard environmental adaptability
Certifications de sécuritéCE, UL, ASC, SIL 2 (CEI 61508), Cat. 1 (EN ISO 13849)Meets safety requirements of major global markets
Durée de vie mécanique10⁷ operationsDurée de vie électrique: 10⁵ operations at rated load
PoidsEnviron. 100gConception légère
  1. Full Series Model List (PSR-SCP Safety Coupling Relay)
Numéro de commande.ModèleTensionCode de fonctionConfiguration des contactsSafety LevelFonctionnalités spéciales
2986575PSR-SCP-24DC/FSP2/2X1/1X224CCFSP22NON+1NCSIL 2Test pulse filtering, safety shutdown
2986960PSR-SCP-24DC/FSP/2X1/1X224CCFSP2NON+1NCSIL 3Test pulse filtering, safety shutdown
2981978PSR-SCP-24DC/FSP/1X1/1X224CCFSP1NON+1NCSIL 3Test pulse filtering, single-channel enable
2981839PSR-SCP-24UC/URM/3X1/3X224UCURM3NON+3NCSIL 3Wide-range voltage, forced guided contacts
2963747PSR-SCP-24UC/URM/5X1/2X224UCURM5NON+2NCSIL 3Wide-range voltage, forced guided contacts
2963750PSR-SCP-24UC/ESA4/2X1/1X224UCESA42NON+1NCSIL 3Emergency stop / safety gate monitoring dedicated
2963763PSR-SCP-24UC/ESA4/3X1/1X2/B24UCESA43NON+1NCSIL 3Avec socle, arrêt d'urgence / safety gate monitoring
2981428PSR-SCP-24DC/ESD/5X1/1X2/30024CCESD5NON+1NCSIL 3300ms time delay, safety gate monitoring
2981020PSR-SCP-24DC/ESA4/1X1/1X224CCESA41NON+1NCSIL 3Single-channel, arrêt d'urgence / safety gate monitoring
  1. Concurrent / Obsolete Model Replacement List

4.1 Same Brand Alternative Models (Directly Compatible)

Modèle originalModèle de remplacementReplacement DescriptionScénario d'application
2986575 (FSP2 Version)2986960 (FSP Version)Upgraded to SIL 3 attestation, functionally compatible with improved performanceApplications requiring higher safety integrity level
2986575PSR-PC32-2NO-1NC-24DC-SP (2700581)General coupling relay without test pulse filter, moindre coûtNon-safety-critical applications, budget limited
2986575PSR-SCP-24UC/URM/2X1/1X2 (2981838)Wide-range voltage (24V CA/CC), forced guided contactsUnstable voltage environment, higher reliability required

4.2 Cross-Brand Competitor Comparison (Functionally Equivalent)

Phoenix ModelModèle SchneiderModèle SiemensPilz ModelPrincipales différences
2986575Zelio SR2B121BD3TK2825-1BB40PNOZ X2.7PPhoenix more compact (17.5mm) with integrated FSP2 filter
Schneider/Siemens lower price; Pilz higher SIL 3 niveau
Phoenix plug-in terminals allow easier replacement
  1. Environnement d'application & Cas industriels

Recommended Application Scenarios

Process Industrial Automation: Safety coupling between SIS digital output signals and field devices

Machine Safety Control: Safety shutdown loops for robotics, machines d'emballage, printing machinery

Process Industry: Safety interlock systems for petrochemical, pharmaceutique, food & industries des boissons

Fabrication automobile: Signal isolation and amplification for production line safety gates and emergency stop buttons

Logistique & Entreposage: Safety control loops for stackers in automated warehouses

Energy Industry: Safety shutdown control systems for wind power and PV inverters

Cas d'application typiques

  1. Chemical Reactor Safety Control System

Application Target: Connect PLC digital output to emergency shutdown valve actuator to realize safety state shutdown

Core Advantage: Integrated FSP2 test pulse filter avoids false valve actuation caused by PLC self-test pulses

Safety Configuration: Redundant design with 2 NO contacts; 1 NC contact for fault alarm

Effect: Meets SIL 2 safety level, ensures stable reactor operation and reduces false shutdown rate by 30%

  1. Automotive Welding Robot Workstation

Application Target: Couple robot controller safety output with safety gate locking device

Core Advantage: 17.5mm narrow body saves cabinet space; plug-in terminals simplify maintenance

Safety Configuration: 2 NO contacts parallel control safety gate lock electromagnet; 1 NC contact connected to alarm lamp

Effect: Compliant with EN ISO 13849 Cat. 1, improves production line safety and efficiency

Not Recommended Scenarios

Applications requiring SIL 3 or higher: Adopt SIL 3 certified models such as 2986960

High vibration environments: Additional shockproof bracket (par exemple. Phoenix ES-Mount series) requis

De plein air / humid environments: IP20 only for indoor dry use; outdoor installation needs protective enclosure

Haute tension & high current control: Exceeding 5A/250V AC requires external contactor

  1. Wiring Diagram & Définition du terminal (Engineering Design Essential)

Disposition des bornes (Front View)

13 14 23 24 31 32 A1 A2

┌─────────────────────────────┐

│ │

│ PSR-SCP-24DC/FSP2/2X1/1X2 │

2986575

│ │

└─────────────────────────────┘

Terminal Function Definition

Numéro de borne.FonctionTaperRemarques
A1/A2Power supply input24À DCA1=Positive, A2=Negative, reverse polarity protection
13/14Normally Open Contact 1Safety OutputEnable path 1, 5A@250V AC/30V DC
23/24Normally Open Contact 2Safety OutputEnable path 2, 5A@250V AC/30V DC
31/32Normally Closed ContactSignal / AlarmFault status indication, 5A@250V AC/30V DC

Typical Application Circuit (PLC Safety Output Coupling)

PLC Safety Output → [2986575] → Field Actuator

(FAIRE) A1/A2 13/14/23/24 (Safety Gate / E-Stop)

↑ ↑

24VCC 31/32 → Alarm System

Points clés du câblage:

  1. Power connection: A1 to 24V DC positive, A2 to negative; stable power supply required
  2. Câblage des contacts: 13/14 et 23/24 NO contacts can be series or parallel for higher reliability
  3. Alarm wiring: 31/32 NC contacts closed normally, open under fault; connect to indicator lamp or PLC input
  4. Wiring standard: Separate safety loops from power loops; use shielded cable with single-end grounding of shield layer
  5. Selection Formula & Quick Reference Rules

Selection Mnemonic

Safety coupling PSR‑SCP,

24DC for DC power adapt,

FSP2 filter stops false act,

2NO+1NC contact set exact,

17.5mm slim saves cabinet space fact,

SIL 2 grade keeps safety intact,

Order by 2986575 exact,

Plug-in wiring easy to correct,

Test pulse blocked, shutdown perfect.

Quick Reference Rules

  1. Correspondance de tension: Select 24DC for DC system or 24UC for wide-range voltage
  2. Configuration des contacts: XNO+YNC — X = enable paths (1-5), Y = alarm contacts (1-3)
  3. Function Selection: FSP = test pulse filter; ESA = emergency stop/safety gate; URM = forced guided contacts
  4. Safety Level: FSP2 = SIL 2; FSP/ESA/URM = SIL 3
  5. Référence des dimensions: 17.5mm narrow width ideal for compact control cabinets, économie 70% espace d'installation
  6. Maintenance Tip: Plug-in terminals allow module replacement without rewiring, réduire les temps d'arrêt
  7. Air Freight Compliance & Certification Info (International Trade Essential)

Air Freight Compliance: Built-in electromagnetic coil, no lithium battery / super capacitor. Compliant with IATA DGR Class 9 non-restricted goods, shippable as general cargo.

Certifications:

CE: Compliant with EN 61508, EN ISO 13849

UL: Compliant with UL 508 Industrial Control Equipment Standard

ASC: Compliant with Canadian electrical safety standards

SIL 2 Functional Safety: TÜV Rheinland certified, meets IEC 61508

ATEX: Suitable for potentially explosive atmospheres (partial models)

Environmental Certification: Conforme à la directive RoHS, free of lead, mercury, cadmium and other hazardous substances; meets REACH regulation requirements.

  1. Achat & Inventory Information
Purchasing ItemDétails
Minimum Order Quantity1 morceau
Lead TimeStandard 7-10 jours ouvrables; Express 3-5 jours ouvrables
ConditionnementIndividual box packaging, 10 pcs per carton
Période de garantie2 years from date of purchase
Recommended Spare PartSame model or 2986960 (SIL 3 version améliorée)

Précédent:

Suivant:

Laisser une réponse

Laisser un message