LXM32: Lexium32 series servo M: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function) D72: Peak output current 72A, continuous 24A N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply Core Electrical Specifications Item Specification Power Supply 3-phase AC 208~480V, 50/60Hz Rated Power 400V class: 7kW; 230Classe V: 5kW Continuous Output Current 24A (8kHz carrier ...

  • Détails du produit

LXM32: Lexium32 series servo

M.: Multi-fieldbus version (CANopen supported, built-in encoder acquisition and positioning function)

D72: Peak output current 72A, continuous 24A

N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply

Spécifications électriques de base

ArticleSpécification
Alimentation3-phase AC 208~480V, 50/60Hz
Puissance nominale400Classe V: 7kW; 230Classe V: 5kW
Courant de sortie continu24UN (8kHz carrier frequency)
Courant de sortie de crête72UN, sustainable for 5s
Filtre CEM intégréStandard integrated
Speed Loop BandwidthUp to 1600Hz, réponse dynamique élevée
Fréquence porteuse8kHz
DC Bus Undervoltage Threshold350V (400Classe V)

Communication & E/S

  1. Bus de terrain: CANopen (LXM32M model, different from pulse-type LXM32A)
  2. Numérique: Multiple 24VDC discrete inputs including 2 high-speed capture CAP ports; sorties numériques
  3. Interface d'encodeur: Supports SinCos and EnDat, compatible with BSH/BMH servo motors
  4. Interfaces: RJ45 debug port, detachable color-coded terminals for convenient cabinet wiring and maintenance

Moteurs correspondants

Compatible with BSH / BMH 400V class servomoteurs of Lexium32 series. Typical match: 140-flange BSH high-torque motor, continuous torque up to 27.8N·m, peak 90.2N·m, common speed 3000rpm.

Scénarios d'application

Machines d'emballage, machine tool feed axes, CNC cutting, machines textiles, material handling conveying, multi-axis synchronization equipment; suitable for automated production lines requiring CANopen bus multi-axis linkage and high dynamic positioning.

Installation & Environnement

Book-style cabinet mounting, vertical installation on control cabinet DIN rail

Catégorie de surtension: Class III

Max leakage current: 30mA

Recommended wire gauge for power terminals: 3mm², tightening torque 0.5N·m

Faute & Notes de mise en service

  1. Common Alarms: Overcurrent OC, Overvoltage OV, Undervoltage UV, Défaut d'encodeur, Overheat OH
  2. Logiciel de mise en service: Alors bouge, supports online parameter configuration, oscilloscope sampling and automatic inertia tuning
  3. For high-power working conditions, it is recommended to install an external 1mH line reactor to reduce harmonics and incoming current surges

Remplacement & Selection Remarks

Pulse version of the same series: LXM32AD72N4 (pas de CANopen, pulse-direction control)

Alternative de mise à niveau: Schneider Lexium28 series; comparable competitors: Siemens V90, Mitsubishi MR-J4

Note: LXM32 is a discontinued legacy series. Lexium28 is preferred for new projects; stock or second-hand units are available only for spare part projects.

Référence du code SH

85011099 (servomoteur, re-verify customs classification before customs declaration)

LXM32MD72N4 SoMove Power-on Commissioning Parameter Template

En vigueur: Lexium32M 7kW CANopen bus servo, matched with BSH/BMH 400V motors; SoMove software, expert mode password 696969

Pre-operation: Complete hardware wiring including power cable, encodeur, arrêt d'urgence, frein, CAN bus and 24V control power supply; perform no-load jog test first, then auto-tune under load; save parameters to EEPROM after modification.

  1. Configuration de base (Simply Start Wizard Page)
Nom du paramètreParameter IDParamètre recommandéDescription
Control SourceDEVcmdInterfBus de terrainLXM32M CANopen positioning mode; temporarily change to Terminal for local jog
Motor SelectionMotor SelectionSelect corresponding BSH/BMH modelDrive loads motor nameplate parameters automatically; must not select incorrectly
Type d'encodeurENC1_typeSinCos / FinDatSelect according to motor encoder; EnDat absolute encoder requires battery module
Fréquence porteusePWM_Freq8kHzDefault for LXM32MD72N4, not recommended to increase
Sens de rotationInvertDirOfMoveDÉSACTIVÉ (Défaut)Set to ON if rotation direction reversed; power cycle required after change
Auto Enable on Power-upIO_AutoEnable0 (Disabled)Disabled during commissioning; can be set to 2 for mass production after safety assessment
  1. Axis Limit Parameters (Axis Configuration → Limitations)
Nom du paramètreParameter IDParamètre recommandéDescription
Max Output CurrentCTRL_I_maxCourant nominal du moteurLimit maximum torque to protect machinery; cannot exceed 72A peak of drive
Max Motor SpeedM_n_maxVitesse nominale du moteurTypical 3000rpm for BSH/BMH, do not exceed nameplate
Positive Software LimitPOS_LIM_PUser unitInside mechanical hard limit to prevent overtravel
Negative Software LimitPOS_LIM_NUser unitSame as positive limit
E-Stop DecelerationQS_DecCoutumeDeceleration triggered by emergency stop, safety related
  1. E/S & Paramètres de sécurité (Axis Configuration → IO)
Nom du paramètreParameter IDParamètre recommandéDescription
Positive Limit ContactIOsigLIMPNC normalement ferméDefault for safety standards; set to NO if using normally open sensors
Negative Limit ContactIOsigLIMNNC normalement ferméIdem que ci-dessus
Brake Release DelayBRK_AddT_Release100MSBrake motor: wait for brake release before movement after servo enable
Brake Apply DelayBRK_AddT_Apply50MSDelay brake output after servo disable to prevent axis falling
Réinitialisation des défautsIO_FaultResetAssign DI terminalExternal reset button
  1. Position Scaling (Mise à l'échelle, Core for Positioning Projects)

User units per revolution, example: 10mm per revolution for lead screw, modify as required

| Nom du paramètre | Parameter ID | Example Value | Description |

| —| —| —| —|

| Position Numerator | ScalePOSnum | 10 | Numerator of travel per revolution |

| Position Denominator | ScalePOSdenom | 1 | Dénominateur; example: 10mm/rev → 10/1 |

| Velocity Scaling | ScaleVELnum / ScaleVELdenom | Follow position | Velocity unit: mm/s |

| Acceleration Scaling | ScaleACCnum / ScaleACCdenom | Follow position | Acceleration unit: mm/s² |

Raw encoder resolution: 16384count/rev for SinCos motors

  1. Servo Loop Gains (Tuning Page, No-load → On-load Auto-tune)

Prioritize SoMove automatic inertia identification + auto-tune, then fine tune

| Nom du paramètre | Parameter ID | Initial Recommendation | Tuning Logic |

| —| —| —| —|

| Position Loop Gain | CTRL_Kp_pos | 3~8 | Higher for stiff mechanics; reduce if oscillation occurs |

| Speed Loop Gain | CTRL_Kp_vel | 80~150 | Base response, reduce for mechanical resonance |

| Speed Loop Integral Time | CTRL_Ti_vel | 8~20ms | Smaller value improves steady-state error, prone to oscillation |

| Velocity Feedforward | CTRL_Kff_vel | 0.6~0.9 | Reduce position following error |

| Acceleration Feedforward | CTRL_Kff_acc | 0~0.3 | For high-speed start-stop; large value causes impact |

| Low-pass Filter | CTRL_FiltVel | 500~1000Hz | Suppress resonance; lower filter frequency at resonance point |

  1. CANopen Fieldbus Parameters (Key for LXM32M)
Nom du paramètreParameter IDParamètre recommandéDescription
CAN Node IDCAN_NodeID1~127No duplicate for multi-axis, consistent with PLC
CAN Baud RateCAN_Baud500kbpsCommon setting; use 250kbps for long distance, terminal resistor ON at both bus ends
PDO MappingPDO ConfigurationStandard positioning PDOTarget position, mot d'état, actual position, fault code
Fieldbus Control ModeProfile ModeProfile PositionPositioning control; select Profile Velocity for speed axis
Profile Acc/DecPRO_ACC / PRO_DECMechanical dependentUnité: user unit/s
Quick Stop RampPRO_QSDecIndependent E-stop decelerationDeceleration upon bus failure
  1. Homing Parameters
Nom du paramètreParameter IDDescription
Homing ModeHOM_mode0~35 optional; commun: limit homing, index homing, direct origin setting for absolute encoder
Homing VelocityHOM_VelFaible vitesse, 50~200 user unit/s
Homing Search VelocityHOM_Vel_SearchSlightly higher than homing speed
Homing OffsetHOM_OffsetMechanical origin offset
  1. Surveillance & Fault Log

Fault Buffer: Stores latest 16 alarms for troubleshooting of OV/OC/OH/ENC faults

Oscilloscope: Sample target position, actual position, following error, bus voltage, motor current for resonance and tuning analysis

Save: Device → User Functions → Save parameters to EEPROM; back up local project as .cxm file

Complete Power-on Commissioning Procedure (Matching Parameter Template)

  1. Connect PC to drive RJ45 debug port via SoMove, establish communication and read factory parameters
  2. Run Simply Start wizard, select motor model and confirm encoder type
  3. Configure limit, brake and I/O terminal definition
  4. Set position scaling and mechanical transmission ratio
  5. Set CANopen Node ID, baud rate and configure PDO
  6. Test à vide: Enable, jog, verify rotation direction, limit and brake logic
  7. On-load test: Run Auto-tune inertia identification to generate base gains
  8. Observe following error and oscillation via oscilloscope, fine-tune 3-loop gains and filter
  9. Test de retour, point positioning test, acceleration/deceleration test
  10. Save parameters to EEPROM and export .cxm backup file

Commissioning Precautions

  1. Expert mode password 696969, enter expert mode to modify advanced parameters
  2. Auto-tune must be performed with actual load; parameters tuned under no-load easily oscillate under load
  3. Incorrect brake timing will directly cause axis falling; test brake function without load during first commissioning
  4. Bus CANopen: Enable terminal resistor only at the first and last device on bus, disable for intermediate nodes
  5. For high-power LXM32MD72N4, check wiring of line reactor and braking resistor before first power-up

Optional Extended Parameters

Résistance de freinage: BRK_R, BRK_P for external braking resistor resistance/power rating, bus overvoltage protection

Entrée analogique: AI scaling for analog speed mode (not commonly used for CANopen projects)

Schneider Lexium32 (LXM32) Full Series Drive Model List

3 main branches: LXM32C (Basic Analog) / LXM32A (Impulsion + Modbus) / LXM32M (CANopen bus type, LXM32MD72N4 belongs to this branch)

Suffix explanation:

M2: Single-phase 200~240VAC; N4: 3-phase 208~480VAC

Dxx: Number after D = peak current (UN), continuous current = 1/3 of peak current

Statut: Full series discontinued, only available on spare parts market

  1. LXM32M (CANopen Bus Type, High Priority, includes LXM32MD72N4)

Single-phase 200~240V (Suffix M2)

ModèleCourant de pointeCourant continu230V Rated Power
LXM32MD12M212UN4UN0.75kW
LXM32MD18M218UN6UN1.0kW
LXM32MD30M230UN10UN1.6kW
LXM32MD42M242UN14UN2.5kW
LXM32MD57M257UN19UN3.5kW

3-phase 208~480V (Suffix N4, your series)

ModèleCourant de pointeCourant continu400V Rated Power
LXM32MD12N412UN4UN0.9kW
LXM32MD18N418UN6UN1.8kW
LXM32MD30N430UN10UN3kW
LXM32MD42N442UN14UN4.5kW
LXM32MD57N457UN19UN5.5kW
LXM32MD72N472UN24UN7kW
LXM32MD85N485UN32UN9kW
  1. LXM32A (Pulse/Direction + Modbus, pas de CANopen, same power rating)

Single-phase M2

LXM32AD12M2, LXM32AD18M2, LXM32AD30M2, LXM32AD42M2, LXM32AD57M2

3-phase N4

LXM32AD12N4, LXM32AD18N4, LXM32AD30N4, LXM32AD42N4, LXM32AD57N4, LXM32AD72N4, LXM32AD85N4

  1. LXM32C (±10V analog basic model, speed/current control only, no positioning)

Single-phase M2

LXM32CD12M2, LXM32CD18M2, LXM32CD30M2, LXM32CD42M2, LXM32CD57M2

3-phase N4

LXM32CD12N4, LXM32CD18N4, LXM32CD30N4, LXM32CD42N4, LXM32CD57N4, LXM32CD72N4, LXM32CD85N4

  1. Matching Motor Series (BSH / BMH for Lexium32)
  2. BSH Motors: SinCos encoder, single-turn/multi-turn, IP50; flange sizes 55/70/100/140mm
  3. BMH Motors: EnDat absolute encoder, multitour, IP65; flange sizes 55/70/100/140/190mm
  4. Liste des accessoires (General for LXM32)

VW3M8101: Résistance de freinage

VW3M8D10: Encoder battery box (for EnDat multi-turn BMH motors)

VW3M8102: Line reactor

VW3M8200: Pre-made I/O terminal cable

VW3M8300: CANopen bus cable

VW3M8400: Motor power cable

VW3M8500: Encoder cable

Branch Comparison Overview

Série de modèlesInterface de contrôlePositioning FunctionBus de terrainApplication typique
LXM32C±10V Analog❌ No positioningModbusPure speed control
LXM32APulse+Direction✅ Point positioningModbusPulse PLC control
LXM32MCANopen✅ Electronic gear / Indiquer / HomingCANopenMulti-axis bus synchronization (LXM32MD72N4)

Conseils de sélection:

  1. Same Dxx model: LXM32A and LXM32M have identical hardware power rating, differ only in firmware communication functions
  2. LXM32MD85N4 is the largest model in this series, 9kW
  3. New project replacement: Lexium28 series; only stock/second-hand units available for spare part projects.