Capteur laser SICK WTB8L-P2131 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Capteur laser SICK WTB8L-P2131 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

contacteur/

Capteur laser SICK WTB8L-P2131

Modèle: WTB8L-P2131 Series: W8 Laser Miniature Laser Background Suppression Photoelectric Sensor Order No.: 6033219 Principe de détection: Diffuse reflection + Optical Background Suppression (BGS) Source de lumière: 650 nm red laser, Cours de laser 1 (Sûr, no eye injury risk) Sortir: PNP, Light-on / Dark-on selectable via adjustment knob Connector: M8 3-pin male connector Standard Accessories: 304 stainless ...

  • Détails du produit

Modèle: WTB8L-P2131

Série: W8 Laser Miniature Laser Background Suppression Photoelectric Sensor

Numéro de commande: 6033219

Principe de détection: Diffuse reflection + Optical Background Suppression (BGS)

Source de lumière: 650 nm red laser, Cours de laser 1 (Sûr, no eye injury risk)

Sortir: PNP, Light-on / Dark-on selectable via adjustment knob

Connecteur: M8 3-pin male connector

Accessoires standards: 304 stainless steel mounting bracket BEF-W100-A

  1. Core Optical Specifications
Élément de paramètreValeur de spécification
Standard Sensing Range (90% high-reflective white paper)30~300 mm
Stable Operating Range40~300 mm
Spot Size (à 300 mm)Ø1.5 mm (ultra-fine laser spot for tiny object detection only)
Méthode d'ajustement4-turn precision potentiometer
Temps de réponse≤0.25 ms
Max.. Fréquence de commutation2,000 Hz (for high-speed production lines)
  1. Spécifications électriques
  2. Tension d'alimentation: C.C 10 ~ 30 V, ripple ±10%
  3. No-load Current: 30 mA
  4. Charge de sortie: PNP, maximum. 100 mA
  5. Signal Level: High ≈ Vs-1.8 V, Low ≈ 0 V
  6. Built-in Protection: Protection contre l'inversion de polarité, protection contre les courts-circuits, protection contre les surcharges
  7. Durée de vie: Average LED service life of 100,000 hours at 25℃
  8. Mécanique & Spécifications environnementales

Dimensions hors tout: 11 mm (W) × 31 mm (H) × 20 mm (D)

Poids: 10 g

Logement: ABS plastic; Lentille: PMMA

Protection contre la pénétration: IP67 (dust-tight, protected against temporary immersion)

Température de fonctionnement: -10 ℃ ~ +50 ℃

Stockage & Transportation Temperature: -40 ℃ ~ +70 ℃

Montage: M3 threaded holes on housing, supplied with stainless steel bracket

MTTFd: 453 années (high-reliability industrial grade)

  1. Pin Assignment (M8 3-pin)
  2. Broche1: DC 24V+ (Positive power supply)
  3. Broche2: Sortie de signal PNP
  4. Broche3: 0V GND (Negative power supply)
  5. Avantages principaux
  6. Ultra-fine laser spot Ø1.5 mm: Detects tiny components, thin labels, fine wires and miniature electronic parts. The standard LED version WTB8-P2131 has a 20 mm spot and cannot detect micro-parts.
  7. Powerful background suppression: Not disturbed by metal surfaces, conveyor belts or dark backgrounds; detection immune to object color.
  8. 2 kHz high-speed response: High-speed counting and presence detection for packaging, printing and electronics production lines.
  9. Miniature compact housing, easy installation in confined equipment spaces.
  10. IP67 dustproof and waterproof design, stable operation in workshop oily and dusty environments.
  11. Classe 1 laser, no extra protective measures required, safe for internal machine installation.
  12. Scénarios d'application typiques

Industrie électronique: Presence detection of PCBs, tiny pins and SMD components

Industrie de l'emballage: Detection of thin labels, medicine pellets, bottle caps and straws

3C Automation: Counting of miniature mobile phone parts and small plastic pieces

Logistics Conveying: Identification of narrow-edge materials, fine wires and thin films

Machine-outil / Moulage par injection: In-position detection of tiny ejector pins and small workpieces

  1. Series Distinction (WTB8L vs WTB8)

WTB8L-P2131: Source de lumière laser, 1.5 mm spot, 2 fréquence de commutation kHz, for micro-object detection

WTB8-P2131: Standard red LED, 20 mm spot, 1 fréquence de commutation kHz, for regular large workpiece detection

  1. Selection Pitfall Avoidance
  2. When detecting black / low-reflective materials, reduce sensing distance and fine-tune potentiometer threshold;
  3. Do not stare directly into the laser beam for extended periods (Classe 1 laser still requires standardized operation);
  4. Avoid long-term lens contact with cutting fluid and highly corrosive chemicals;
  5. Select shielded M8 3-core straight / elbow cables for sites with strong EMI from inverters.

Official Standard Installation Manual for SICK WTB8L-P2131

Modèle: WTB8L-P2131 | Numéro de commande: 6033219

Série: W8 Laser Miniature Laser Background Suppression Photoelectric Sensor

Application: High-precision detection of tiny objects within 30~300 mm

Table of Contents

  1. Consignes de sécurité (Classe 1 Laser, Sécurité électrique)
  2. Unpacking Parts Verification
  3. Mechanical Mounting Specifications (Bracket Fixing, Couple, Espacement de montage)
  4. Electrical Wiring Standards (M8 3-pin Assignment, Wiring Diagram)
  5. Optical Alignment & Potentiometer Calibration Procedures
  6. Indicator LED Status Description
  7. Environmental Mounting Limits & Common Pitfalls
  8. On-site Commissioning & Acceptance Procedure
  9. Matrice de dépannage
  10. Spécifications d'entretien
  11. Consignes de sécurité (Mandatory Compliance)

1.1 Sécurité des lasers

Light source: 650 nm red laser, Cours de laser 1, no eye hazard under normal operation;

Do not stare at the laser spot at close range for a long time; do not refract the beam with magnifiers or mirrors;

Cut off power supply before cleaning the lens during equipment maintenance.

1.2 Sécurité électrique

Power must be disconnected before wiring, installing or removing cables;

Only DC 10~30 V power supply is allowed; L'entrée AC220V est strictement interdite;

Max.. output load 100 mA; cannot directly drive solenoid valves or contactors;

Built-in reverse polarity, short-circuit and overload protection, but standardized wiring is still required.

1.3 Sécurité mécanique

ABS plastic housing; do not strike or squeeze the lens with excessive force;

Lens material PMMA; avoid soaking or wiping with alcohol and strong solvents.

  1. Standard Factory Supplied Parts List
ArticleSpécificationQuantité.
Sensor Main UnitWTB8L-P21311 ordinateur
Stainless Steel Mounting BracketBEF-W100-A (Numéro de commande. 5311520)1 ordinateur
M3 Fixing ScrewsMatching locking screws2 pièces
Product DatasheetBilingual Chinese & English specification sheet1 copie

Optional Separately Ordered Parts: M8 3-core straight / elbow cables, extended mounting brackets, vibration-damping gaskets

  1. Mechanical Mounting Specifications

3.1 Dimensions de montage

Overall size: 11 mm (W) × 31 mm (H) × 20 mm (D)

M3 internal threaded mounting holes on both sides of the housing

3.2 Bracket Mounting Steps

  1. Attach BEF-W100-A bracket to the sensor side, align M3 hole positions;
  2. Insert M3 screws and tighten in stages, single tightening torque ≤0.6 N·m;
  3. Fix the long slotted holes of the bracket to the machine frame for front/back and up/down fine adjustment;
  4. Pre-adjust all screws before final tightening to prevent laser spot offset caused by operational vibration.

3.3 Mandatory Mounting Distance Requirements

Minimum sensing distance: 30 mm; stable reliable range: 40~300 mm;

Recommended operating range: 50%~80% of rated distance (100~240 mm) for strongest anti-interference performance;

Clearance between target workpiece and background ≥10 mm to avoid false triggering;

Side-by-side multi-sensor installation: Center-to-center distance ≥40 mm to prevent mutual laser interference.

3.4 Mounting Angle Specifications

Laser optical axis must be perpendicular to the target material surface, tilt angle ≤±5°;

Excessive tilt causes spot deformation, sensing threshold drift and missed detection;

For fine wires and miniature parts, ensure the laser spot fully covers the workpiece center.

3.5 Environmental Mounting Prohibitions

No splashing cutting fluid or long-term dust accumulation in front of the lens;

Keep away from strong electromagnetic radiation zones of inverters and servo motors, distance ≥150 mm;

Do not install adjacent to high-temperature heat-generating components (max ambient temperature +50℃);

Install dust shielding plates for working conditions with continuous water mist or oil contamination.

  1. Electrical Wiring Standards

4.1 M8 3-pin Male Connector Pin Assignment (International Standard)

Numéro de broche.Couleur du filFonctionInstructions de câblage
Broche1BrunDC24V+Positive power supply 10~30V DC
Broche2NoirSortie de signal PNPConnect to PLC input / load positive terminal
Broche3Bleu0V GNDNegative power supply & load negative terminal

4.2 PNP Output Wiring Logic

  1. Connect one end of the load to Pin2 (black wire), the other end to 24V+;
  2. A pull-down resistor must be connected in series for PLC NPN-type inputs; PNP-compatible input modules are preferred;
  3. Use shielded M8 cables for high EMI sites, ground shield layer at single end to cabinet earth.

4.3 Electrical Limit Parameters

No-load current: 30 mA; Max.. courant de sortie: 100 mA;

Ripple voltage ≤±10%; direct power supply from switching power supplies without filtering is forbidden;

Recommended cable length ≤10 m; use shielded cables for long wiring runs.

  1. Optical Alignment & Potentiometer Calibration (Core Mounting & Étapes de mise en service)

4-turn precision adjustable potentiometer on sensor top: Clockwise = increase sensing distance; Counterclockwise = reduce sensing distance.

Standard Calibration Procedure (BGS Background Suppression Mode)

  1. Power on and confirm the green stable indicator LED illuminates steadily;
  2. Étape 1: Place the target workpiece at actual detection position, align laser spot to workpiece center;
  3. Slowly rotate potentiometer clockwise until the orange output LED stays constantly lit;
  4. Étape 2: Remove workpiece, only keep background in position;
  5. Fine-tune potentiometer counterclockwise until the orange LED fully turns off;
  6. Repeat workpiece placement / removal test 3~5 times: LED ON with workpiece, LED OFF without workpiece, no flickering = calibration completed;
  7. Lock the potentiometer dust cap after calibration to prevent offset from vibration.

Calibration Tips for Special Materials

Black low-reflective workpieces: Shorten sensing distance to ≤200 mm and slightly raise threshold;

Transparent films / thin sheets: Reduce sensing distance and avoid spot hitting reflective edges;

High-speed production lines: Ensure green LED stays steady (signal stable) without flickering after calibration.

  1. Dual Indicator LED Status Description

LED verte (Stability Indicator)

Steady ON: Sufficient signal, détection stable;

Flashing: Marginal signal, excessive distance / insufficient object reflectivity, prone to false detection;

DÉSACTIVÉ: No valid reflection, out of sensing range.

Orange LED (Switch Output Indicator)

Steady ON: Object detected, PNP output conductive;

DÉSACTIVÉ: No object detected, output disconnected;

Rapid flashing: Court-circuit / overload protection activated; cut off power immediately to inspect wiring.

  1. Environmental Mounting Parameter Limits
ArticleAllowable RangeConsequence of Exceeding Limits
Température de fonctionnement-10℃ ~ + 50 ℃Thermal drift at high temp, no response at low temp
Stockage & Transportation Temperature-40℃~+70℃Aging of electronic components
Ingress Protection GradeIP67Prohibit long-term immersion or direct high-pressure water jet spraying on lens
Humidité5%~95% non-condensingCondensation causes lens reflection and false triggering
Résistance aux vibrations10~2000 Hz, 100 m/s²Spot offset and loose screws beyond rated range
  1. Complete Machine On-site Acceptance & Verification Procedure
  2. Mechanical Verification: No loose brackets, laser spot stably positioned on material detection surface;
  3. Electrical Verification: Supply voltage 22~26V DC without voltage drop; load current <100 mA;
  4. Functional Verification:

Reliable triggering of workpieces within rated range;

Complete background suppression with zero false triggering;

500 consecutive reciprocating operations without missed or false detection;

  1. Stability Verification: Run equipment at full load for 30 minutes with no abnormal LED flickering.
  2. Matrice de dépannage (Common Post-installation Issues)
Symptôme de panneCause premièreMounting Correction Measures
Orange LED fails to light when workpiece is present1. Distance out of range; 2. Potentiometer threshold too low; 3. Laser spot misaligned with workpieceShorten mounting distance, turn potentiometer clockwise, realign laser spot
Orange LED stays ON without workpiece (background false triggering)Excessively reflective background, workpiece-to-background gap too small, over-high thresholdReduce sensing distance counterclockwise, reserve ≥10 mm gap between workpiece and background
Green LED flashes continuously, unstable detectionExcessive distance, lens covered by dust, severe voltage fluctuation, loose mounting from vibrationShorten sensing distance, clean lens, add power supply filtering, retighten bracket screws
Orange LED flashes rapidlyOutput short-circuit, load current exceeds 100 mA, reversed power wiringCut off power to inspect cables, replace smaller load, correct brown/blue power wiring
All LEDs off, sensor completely non-functionalPower circuit break, M8 connector not fully tightened, supply voltage below 10VRe-seat M8 connector, measure supply voltage, replace cables
  1. Long-term Maintenance Specifications
  2. Inspection quotidienne: Lens free of oil and dust accumulation, brackets tight without looseness;
  3. Weekly Cleaning: Wipe lens with dust-free soft cloth dampened with clean water; acetone and banana oil are prohibited;
  4. Monthly Recheck: Recalibrate potentiometer threshold and verify stable LED status;
  5. Annual Inspection: Check cable aging and integrity of M8 connector waterproof sealing rings.

 

  1. Forbidden Mounting Operations (Hard Restrictions)
  2. Do not tighten screws with torque exceeding 0.6 N·m to avoid cracking housing threads;
  3. Do not aim lens at highly reflective metal surfaces for prolonged direct irradiation;
  4. Do not sharply bend cables with bending radius <5 mm;
  5. Do not install directly without protective measures in condensing or continuous water mist environments;
  6. Do not connect high-power solenoid valves or cylinder coils in parallel to output terminals;
  7. Do not install multiple WTB8L laser sensors facing each other at close range.

Précédent:

Suivant:

Laisser une réponse

Laisser un message